Definning Notification Types

Hi All,
i would like to know how could i create a new combination of notification category with notification origin, to use 03 - Service Notification and Q1 Customer complaint and enable the "Defect Class" field.
Thanks in advance,
Gustavo Carvalheira

hi
Notification category are not configurable, those are defined in the system & u can select the appropriate
We can define only Notification types.
generally you get these data in Q1 notif type.
if you want new one with all detailes mentioned by you then you need to do the IMG settings.
Plant Maintenance and Customer Service->Maintenance and Service Processing->Overview of Notification Type.
here you need to create a new notif type and then add the
screen
1.Screen Areas in Notification Header
Screen type hdr H500 Header quality notification
ScrnType Object O500 Object for customer complaint / batch
2.Screen Structure for Extended View
3.Screen Structure for Simplified View
etc...
and when you go to create the notification type from Define Notification Types, there based notification origin the system selects the catagory
-ashok
Edited by: ASHOK on Oct 22, 2008 6:06 PM

Similar Messages

  • User defined notification & custom alert in business process(eInsight)?

    HI All,
    I have a User Defined Notification Type setup in AlertAgent.
    I want to create a Custom Alert in a Business Process that will be picked up by the User Defined Notification Type I have setup. I can't figure this out though?
    The documentation doesn't seem to cover this (briefly mentions collaborations only), and I can find no examples.
    Can you please explain how this is done, and/or send an example.
    Cheers,
    Ken

    from SUN...
    To send out a custom alert, you'll need to call the alerter.cutom() method. However, this method is available only in a JCD.
    Here is the syntax:
    alerter.custom(String arg0, String arg1, String arg2);
    where
    - arg0 be an existing alert type you created via your properties file, or you defined in the AlertAgent as a new Notification.
    - arg1 is the severity of the alert
    - arg2 is the detailed message for the alert
    example:
    alerter.custom("HD-00001", "INFO", "custom test alert")
    The severity must be one of the valid alert severity levels {"FATAL","CRITICAL","MAJOR","MINOR","WARNING","INFO"}. There is a mention of how this should work in eGate_Sys_Admin_Guide.pdf section 8.4 and 8.4.1.

  • Where to maintain notification type for txn IW21 in Plant maintanance

    Hi Guys,
                  I like to maintain notification type for txn IW21 in Plant maintanance module. Where can I set this.
    Cheers
    S Kumar

    Hi,
    Here is the path to maintain Notification Types.
    Use Tcode SPRO
    Plant Maintenance & Customer Service -> Maintenance & Service Processing -> Maintenance & Service Notifications -> Notification Creation -> Notification Types -> Define Notification Types
    Then,Click "New Entries" button. Enter the Notification which you need & Save.

  • Assignment of notification type while doing results recording

    We use a different quality notification while doing results recording.
    It is taking a notification type different from what we want to make it defaulted.
    Please advise the configuration steps for defaulting a QM notificaiton type , while doing resuolts recording for defects.
    Thanks,
    Manohar

    Hi,
    Quality notifications are created as part of defects recording and defect recording can be done during result recording of inspection lots. Defects are confirmed during inspections and recorded for specific inspection lots. Hence you need to assign a suitable quality notification type to each inspection type, for which defects are to be recorded.Menu path is :Quality Management>Quality notifications>Defects recording>Define notification type>Define notification type for Inspection type.
    Note: You should use this inspection type to make sure that only one quality notification is created, even if defect records have been created for several operations.
    regds,
    atul

  • Setting notification type for PCR

    Hi ALL,
    Here is what I am tryign to do. I opened a Change request form:
    Change Employee Group and Subgroup
    It loaded fine and I am able to review it. But when I try to submit the form. It gives me this error.
    Notification type 57 not defined
    and for other form it gives Notification type 56 not defined.
    Do we need to set these notification anywhere? In case can any one help me with that procedure?
    THanks for your help..

    Hi James,
       Goto tcode - SPRO -> Cross Application Components -> Internet/Intranet Servies -> Scenario Definition - > Prepare General Notification - > Notification Creation -> Define Notification Type...Here you can create a notification as you want.Do let me know still if you have any problem.

  • Quality notification type

    Dear Experts,
    I am a QM Consultant.
    How to create or include a new notification type? Can anybody brief it?
    Regs,
    RPV

    hi
    goto
    SPRO>Quality Management>Quality Notifications->Notification Creation-->Define Notification Types
    here select any existing QM notification tyrp and click on copy as button (F6)
    now change the name and descrioption and save
    ashok

  • Whole notification type copy

    HI,
    Is there a way to copy the whole customizing for a certain notification type? That is: copy not. type Q3 to a new not. type Z3 with all screen, number ranges, profiles...
    Any idea is welcome!
    Regards,
    mr.

    Hi !
    Yes it is possible to create new notification type, or you can copy from an existing one like Q3,
    QCC0 --> Q-Notif --> notif creation --> notif type --> Define notif type
    Now click on new entry and create new type.
    Or just right to the new wntry buttoon, you have copy as button, click on that and it takes you to the new page, change the notification name and create new.
    After that you need to check number ranges and all. And you must set the screen template so that you can use this type.
    revert for further help

  • No quality notification type has been defined for inspection type 89

    Hi
    When I am creating a manual inspection lot and want to create a quality notification it gives me this error "No quality notification type has been defined for inspection type 89" where do I assign the notifications to the inspection lot.???
    I want to know where do I configure it??
    Regards
    Suresh

    Hi
    Path for assigning the Qualtiy notification type to Qualtiy  inspection type:
    SPRO--> Qualtiy Mangement --> Qualtiy inspection --> Inspection lot creation -->
    Maintain Inspection types.
    Select the inspection type and goto details screen
    You can find notification type field in the details.Give the value and Save.
    Regards
    Ramakrishna

  • QM01 - Add new fields under SUBJECTS tab for notification type Q2

    Hi Experts,
    My requirement is to add 2 new fields to the create Quality Notification (QM01) Tcode under SUBJECTS tab for Notification type Q2.
    I followed the following steps to achieve this :
    [ SPRO -> Quality Mnanagement -> Quality Notifications -> Overview Quality Notification Types -> Then I selected Q2 and then selected dcreen structure for extended view -> Double clicked on 10\TAB02 ].
    Now I arrived on the screen where we have to define the custom screen area and  screen number.
    But here in this case (Q2 notification type) all the 5 screen areas are already occupied , so where can I add my custom subscreen ??
    Please refer to below screen shot for better understanding :
    Please help ! Thanks in advance.
    Kind Regards,
    Ashish Goyal

    Dear narendra bora 
    You can enter the more than two persons in but not on header screen. In operation you can make each seperate person responsible for each operation & that can be entered against each operation seperately. Also if operation is carried out by two person then also you can enter that in the form of split. 
    But it is not possible to enter two users in reported by field.
    I hope this will resolve your issue.
    Regards

  • User Exits for IW21 - Notification Type

    Hi ,
    I need to access User Exit related to IW21 , IW22 Transactions.
    I require the user exit to customize process for a specific Notification type 'KS'.
    User exit when a notificatrion Type is created & when it is modified.

    User Exits and Badi's For IW21 & IW22
    BADI's
    IQS0_STATUS_MAINTAIN Control of Changeability of User Status
    IWO1_SUBSCREEN_0170  Display Additional Data on Object Screen 0170 PhysicalSample
    IWOC_LIST_TUNING     Performance Tuning for Lists in PM/CS
    IWOC_OBJECTINFO_CHNG Changes to Data of Object Info Screen
    NOTIF_AUTHORITY_01   Additional Authorization Checks for the Notification
    WOC_FL_DETERMINE     Determine Date for Determining Installation Loc. Equi.
    USER EXITS
    IWO10026  User check on setting status 'Do not perform'
    IWO10027  User exit: Generate user-defined settlement rule
    IWOC0001  Create PM/SM notification: Determine reference object
    IWOC0002  PM/SM notification: Check whether status change is allowed
    IWOC0003  PM/SM authorization check of ref. object and planner group
    IWOC0004  Change single-level list editing PM/QM/SM ALV settings

  • Default PM Notification type to PM Order type

    HI All,
    Please any one let me know where I need to make setting to obtain the default Notification type from PM Order creation or change mode.
    I have done some analysis i.e. I am able to obtain the default Order type for Notification i.e. when I click on create Order button in Notification creation or change mode (IW21 / 22). The pop-up window appears with default PM order type. To obtain the default value , we need make settings in SPRO i.e. Maintenance and Service Processing > Maintenance and Service Notifications > Notification Creation > Notification Types > Assign Notification Types to Order Types.
    I required vice verse i.e.  Default Notification type from PM Order creation or change mode. To obtain this I have checked any SPRO settings to make. Example: Maintenance and Service Processing > Maintenance and Service Orders > Functions and Settings for Order Types > Define Notification and Order Integration. But here the notification is immediately created, when we save the PM order. This is happening since the automatic creation check box (3 rd column) is checked in SPRO settings i.e. Define Notification and Order Integration.
    I need the system to display the pop-window with default notification type, when I clicked on create Notification button in PM order create or change mode (Iw31/32). Please let me know where I need to make settings for this?
    Regards
    Ramu

    Hi Ramu,
    Goto SPRO ->Maintenance and service processing ->Maintenance and service orders ->Functions and settings for order type ->Define notification and order integration.
    Goto specific order type remove the check box in the third column.
    Result:When ever you create the service order, notification is not created automatically.You have to goto IW32 goto create notification click on the icon then pop-up appears for the notification.Hope this solution resolve your problem.
    Regards
    Suman Kumar

  • Sales order creation is not possible for this notification type

    Hello,
    I want to create Sales Order through following menu:
    Notification -- Functions - Sales order - CreateSelection of Order Type.
    But I get following message:
    'Sales order creation is not possible for this notification type'
    The message says: No sales order type is assigned to the notification type.
    But I did not find any such configuration where I can assign notification type to Sales Order document type.
    Please help.
    regards

    Transaction OIM9
    Menu Path
    Customizing > Plant Maintenance and Customer Service > Maintenance and Service Processing > Maintenance and Service Notifications > Notification Creation > Notification Types > Define Order Types and Special Notification Parameters
    Nomally CS (customer service) area use this function.
    Regards
    Luke

  • Sales Order link to Q3 Notification Type

    Hello,
    I am trying to configure the reference documents section of a Q3 notification type.  It won't let me display the Sales Order fields on the notification even though the config settings allow it.  We have a Q1 notification type with the same config settings and Sales Order is being displayed.  Has SAP hard coded which fields can be displayed by notification type?
    Thanks,
    Justin

    Hi Justin,
    This sales order filed is available in Q3 notification check in Processing tab.
    If this field is hidden then check below settings in u r system
    Run QCC0 ---> Quality Notifications ---> Notification Type ---> Define screens templates
    By selecting your Q3 notification check whether sales order field hidden
    Field Selection: General Screens
    Field Selection: Initial Screens
    Field Selection: Reference Object Screens
    Field Selection: Partner Screens
    Shiva

  • Down time for N2 and N4 PM Notification type

    Dear Experts,
    We are not getting downtime duration for notification type N2 & N4 (as
    it is available for N3 type) in report IW28/29.
    Can we have downtime duration for N2 & N4 above reports?
    Also effect field is required for N2 & N4 under system info tab as available for N3 type
    Thanks in advance.

    Hi Don,
                 If N2 and N4 are the notificatin types defined in your system .. then check whether you have configured all the screen structures in simple and extended view as per spro >PM->maintenance and service processing -
    >maintenance and service notificatins -
    >overview of notification type
    you should have screen area 035 & 040 .. for breakdown tick i guess ..
    and while creating  the notification in iw21 mark the breakdown tick ...
    regrds
    pushpa

  • Problem to define recipent type for Send mail option in WF

    Dear All,
    I am trying to create a send mail from WF.
    but i am struggling to define recipent   type as it shows following options
    1.  Organizational unit    -   we don not have org chart defined in our company
    2.  JOB                           -   I think it is again with Org Chart
    3.  Position                     -   it is again with org chart
    4.  work center              -   not applicable
    5.  user
        when i define it it gives me error message with binding
         Express
         typid
         addressstrings
         are not defined in container
    6.  expression              -  i do not know how to use
    7.  Workflow initiator expression     -   I do not know how to use
    Kindly help me to resolve this issue.
    Best of Regards,
    Gaurav Sood

    If you choose the Recipient type is "E-Mail address", you can enter the email of the person manually to whom the email should be sent or you can still choose an expression (Container) which will have the value determined dynamically.
    If you choose the Workflow Initiator, the notification goes automatically to the user who has started the workflow.
    If User, you can enter the sap user id manually or determine dynamically using expression.
    If expression, you can choose a container element which holds run time value.
    Regarding the binding errors, you can generate the binding automatically.
    Regards,
    PR.

Maybe you are looking for

  • Hp mini 110-3000

    I accidentally reformatted my mini including where the recovery drive is..so my option is clean install.when im trying to reformat my hd using win7 ultimate it is detected but i cannot install the os!!!! Primary check disk and memory test all passed.

  • HFM 3.5 to HFM 9.3.1 issues Urgent help needed

    Dear All: i am on an upgrade Scenario Upgrading HFM 3.5 and Hyperion Reports 7.0 to System 931 Environemt details : Windows 2003 sp2, SQL 2000 sp3a PROD HFM Server version : 3.5.1 sp2 PROD HR Version 7.0 Server 1: HFM Full Server Server 2: HFM App Se

  • Problem with upgrade Windows 2003 to Windows 2008

    Hi, I have problem with upgrade Windows 2003 to Windows 2008 R2 When I run installer it check compatibility drivers and programs after that appear message that I need to uninstall  "adaptec storage manager" but I already remove this driver from the s

  • Can I see java script img on my desktop?

    Hi guys I have been dabbling with a few free page makers and that was fun..Igot my trial dreamweaver down load. I love it,. I,m just anewby geek so if you throw me out plese screa out the answer as you close the door. Can I view images on my page w h

  • Mdworker quit unexpectedly. How to fix it?

    Hello to everyone, When ever I open some specific Microsoft office Word files (using Microsoft Word 2011) in my MBR and I try to save them the system gives me a report "mdworker quit unexpectedly". If I make a new file and I save it then no error is