We are doing delta extraction for the all Master Data Objects from R/3, wherever supported by SAP. But, for 0costcenter, 0costelmnt,0profit_ctr and 0G/LAccount from R3 Production System PR1 we are getting few records in Delta.
<b>Scenario is like this:</b> Master Data for these objects is not created in this system, it is created in other Prod System PR5 and Master Data is then ALE'D to all Production Systems.
<b>Problem in Delta :</b> In Delta Extraction for these Master  Data Objects, we are not getting any records which are ALE'd to this System. We are only getting some records which are changed in the PR1 system. That Means when Master Data is ALE'd from PR5 to PR1 it is not Populating in the Delta Queue Tables in R3.
Delta is working fine for all other Master Data Objects which are Created in PR1 and MAintained in this System.
Not sure where exactly is the problem, after ALE to PR1 is there any program need to be run in R3 which populates the Delta Queue Tables for these Master Data Objects.
Any IDeas or Suggestions on this.
Regards
Deepak

Hello Deepak,
ideally you should have a single source for your master data (PR5). So why don't you load the master data from this box into BW (and skip PR1)?
If you still do changes in PR1 (would this not make it out-of-sync with PR5?), then you can run the delta extrator as well.
Regards,
Marc
SAP NetWeaver RIG, US BI

Similar Messages

  • Delta extraction issue

    Dear all,
    We are doing an delta extraction from 2LIS_01_*.  Delta update is not successfull with the following error messages.
    :error while transfering the data
    :error occured in the source system
    could anyone  help to fix this issue?
    Thanks,
    Krishna

    error message in rsmo
    Error message from the source system
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.
    Procedure
    How you remove the error depends on the error message.
    Note
    If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the request.
    when i click on Error message in the status tab the message is
    *Errors occurred while transferring data ( ).
    Errors in source system*

  • ISU 0uc_sales_stats_01 Delta extraction Issue

    Hi All,
    we have a strange issue.
    We recently went through migration/conversion during which we did a reinit of 0uc_sales_stat_01.
    I have re inited it on 10th then on every day it adds up the delta records starting from 10th till that date.
    on 11th it brings 10 & 11th, on 12 it brings up 10th 11th and 12th etc,.,.
    When i did analysis from my end i can see table DBESTA_BWTRIG which is used for initial selection of posting date & recon keys in standard extract.
    Once mass billing, Mass invoicing happens i get entries in this table.
    But these entries do not go away even after the data is extracted into bw.
    I can see entries in this table against 0uc_sales_stats_02. i deleted the active version of 02 DS and checked but still the entries remain same.
    What is the exact behaviour of this table DBESTA_BWTRIG? how is it updated and deleted or modified?
    How do i identify what is the exact reason for this delta issue?
    Is there any setting where i am missing in ISU?
    Thanks & Regards,
    Jana

    Hey Steve,
    have a look on Des Gallaghers Post in 0UC_SALES_STATS_01 data missing
    He describes that one has to load at first in Full-Mode. You will also find a hint on table DBWESTA_BWPROT in IS-U. There will be the records with open reconciliation key which aren't be extracted because of that.

  • Generic Delta extraction by Function module issue

    Hello Experts,
    Please help !!!
    I have problem for delta extraction by Function module.  For the full load, I wrote function module based on RSAX_BIW_GET_DATA_SIMPLE. It works fine.
    But I would like to have the delta load enabled. Therefore, I modified the datasource, add a delta specific field u2018ztimestampu2019, which type is calendar day.
    Then I create a function module based on template u2018RSAX_BIW_GET_DATAu2019, as this support the upload mode. But when I test this datasource in RSA3, no matter itu2019s full load or initial delta load, it always send me an error, u201CErrors occurred during the extractionu201D.
    I had some debug, and found that there is no value  for i_isource when my function module is called. Therefore it raised the exception.
    But I do not have the chance to debug my code for the delta logic, can somebody help to check?
    I also check the entries in ROOSOURCE,
    For my datasource ZTRNREC_FM_DELTA, The DELTA value is u2018AIEu2019, and extraction method is u2018F2u2019, should I change them to DELTA= u2018Du2019 and extraction method to u2018F1u2019? Where to change?
    FUNCTION ZRSAX_TRAININGREC_DELTA.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SBIWA_S_INTERFACE-REQUNR
    *"     VALUE(I_ISOURCE) TYPE  SBIWA_S_INTERFACE-ISOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SBIWA_S_INTERFACE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SBIWA_S_INTERFACE-INITFLAG OPTIONAL
    *"     VALUE(I_UPDMODE) TYPE  SBIWA_S_INTERFACE-UPDMODE OPTIONAL
    *"     VALUE(I_DATAPAKID) TYPE  SBIWA_S_INTERFACE-DATAPAKID OPTIONAL
    *"     VALUE(I_PRIVATE_MODE) OPTIONAL
    *"     VALUE(I_CALLMODE) LIKE  ROARCHD200-CALLMODE OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SBIWA_T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SBIWA_T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"      E_T_SOURCE_STRUCTURE_NAME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    The input parameter I_DATAPAKID is not supported yet !
    Example: InfoSource containing TADIR objects
    Auxiliary Selection criteria structure
      DATA: l_s_select TYPE sbiwa_s_select.
    Maximum number of lines for DB table
      STATICS: l_maxsize TYPE sbiwa_s_interface-maxsize,
              S_S_IF TYPE SRSC_S_IF_SIMPLE,
              S_COUNTER_DATAPAKID LIKE SY-TABIX.
    Parameter I_PRIVATE_MODE:
    Some applications might want to use this function module for other
    purposes as well (e.g. data supply for OLTP reporting tools). If the
    processing logic has to be different in this case, use the optional
    parameter I_PRIVATE_MODE (not supplied by BIW !) to distinguish
    between BIW calls (I_PRIVATE_MODE = SPACE) and other calls
    (I_PRIVATE_MODE = X).
    If the message handling has to be different as well, define Your own
    messaging macro which interprets parameter I_PRIVATE_MODE. When
    called by BIW, it should use the LOG_WRITE macro, otherwise do what
    You want.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF i_initflag = sbiwa_c_flag_on.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    The input parameter I_DATAPAKID is not supported yet !
    Invalid second initialization call -> error exit
        IF NOT g_flag_interface_initialized IS INITIAL.
          IF 1 = 2. MESSAGE e008(r3). ENDIF.
          log_write 'E'                    "message type
                    'R3'                   "message class
                    '008'                  "message number
                    ' '                    "message variable 1
                    ' '.                   "message variable 2
          RAISE error_passed_to_mess_handler.
        ENDIF.
    Check InfoSource validity
        CASE i_isource.
          WHEN 'ZTRNREC_FM_DELTA'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e009(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      i_isource            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for supported update mode
        CASE i_updmode.
          WHEN 'F'.
          WHEN 'D'.
          WHEN 'R'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e011(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '011'                "message number
                      i_updmode            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for obligatory selection criteria
        APPEND LINES OF i_t_select TO g_t_select.
    Fill parameter buffer for data extraction calls
        g_s_interface-requnr    = i_requnr.
        g_s_interface-isource   = i_isource.
        g_s_interface-maxsize   = i_maxsize.
        g_s_interface-initflag  = i_initflag.
        g_s_interface-updmode   = i_updmode.
        g_s_interface-datapakid = i_datapakid.
        g_flag_interface_initialized = sbiwa_c_flag_on.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF i_t_fields TO g_t_segfields.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
      LOOP AT G_T_SELECT INTO L_S_SELECT
            WHERE FIELDNM = 'ZTIMESTAMP'.
      ENDLOOP.
          IF G_COUNTER_DATAPAKID = 0.
            IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME.
            ELSE.
              OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME
                WHERE ZTIMESTAMP >= L_S_SELECT-LOW
                  AND ZTIMESTAMP  <= L_S_SELECT-HIGH.
            ENDIF.
          ENDIF.
      FETCH NEXT CURSOR G_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR G_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.
    ENDFUNCTION.
    I found some similar issue in this forum by link
    Generic Extractor Delta Function Module code, but still I could not get clear answer.
    Can you please help me:
    1)     why there is no value for i_source , how to fix it?
    2)     For the delta logic for ztimestemp, is it correct?
    3)     Need I modify the entries in ROOSOURCE ?
    Thanks a lot !!!

    Hello Andre,
            Thanks a lot for your help. I did some change , but still does not work. Could you please help check.
    Now the source code are the following, It's based on the RSAX_BIW_GET_DATA_SIMPLE, as you confirm that this also supply the update mode (full, initial delta, delta).
    FUNCTION RSAX_BIW_GET_DATA_TRAININGREC1.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SRSC_S_IF_SIMPLE-REQUNR
    *"     VALUE(I_DSOURCE) TYPE  SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SRSC_S_IF_SIMPLE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
    *"     VALUE(I_READ_ONLY) TYPE  SRSC_S_IF_SIMPLE-READONLY OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    Auxiliary Selection criteria structure
      DATA: L_S_SELECT TYPE SRSC_S_SELECT.
    Maximum number of lines for DB table
      STATICS: S_S_IF TYPE SRSC_S_IF_SIMPLE,
    counter
              S_COUNTER_DATAPAKID LIKE SY-TABIX,
    cursor
              S_CURSOR TYPE CURSOR.
    Select ranges
    RANGES:
            L_R_ZTIMESTAMP FOR ZTRN_REC_TIME-ZTIMESTAMP.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF I_INITFLAG = SBIWA_C_FLAG_ON.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    Check DataSource validity
        CASE I_DSOURCE.
          WHEN 'ZTRNREC_FM'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE E009(R3). ENDIF.
    this is a typical log call. Please write every error message like this
            LOG_WRITE 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      I_DSOURCE   "message variable 1
                      ' '.                 "message variable 2
            RAISE ERROR_PASSED_TO_MESS_HANDLER.
        ENDCASE.
        APPEND LINES OF I_T_SELECT TO S_S_IF-T_SELECT.
    Fill parameter buffer for data extraction calls
        S_S_IF-REQUNR    = I_REQUNR.
        S_S_IF-DSOURCE = I_DSOURCE.
        S_S_IF-MAXSIZE   = I_MAXSIZE.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF I_T_FIELDS TO S_S_IF-T_FIELDS.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
    First data package -> OPEN CURSOR
        IF S_COUNTER_DATAPAKID = 0.
          LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT WHERE FIELDNM = 'ZTIMESTAMP'.
          MOVE-CORRESPONDING L_S_SELECT TO L_R_ZTIMESTAMP.
          APPEND L_R_ZTIMESTAMP.
          ENDLOOP.
    Determine number of database records to be read per FETCH statement
    from input parameter I_MAXSIZE. If there is a one to one relation
    between DataSource table lines and database entries, this is trivial.
    In other cases, it may be impossible and some estimated value has to
    be determined.
         IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD S_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME.
            ELSE.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME
            WHERE ZTIMESTAMP >= L_S_SELECT-LOW
            AND ZTIMESTAMP <= L_S_SELECT-HIGH.
         ENDIF.
        ENDIF.                             "First data package ?
    Fetch records into interface table.
      named E_T_'Name of extract structure'.
        FETCH NEXT CURSOR S_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR S_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.              "Initialization mode or data extraction ?
    ENDFUNCTION.
    I think it already includes the important statements you suggested.
    I test this FM in RSA3, for the Full load mode, it works fine. Also if I checked the debug mode in execution , it will stop in the code and let me debug.
    But when I choose other mode, like 'initializion of the delta transfer'  or simulation of initial delta, I always get error 'error occurs  during the extraction' .. even I choose debug mode, but it could not enter the code for debug..
    Till now I did not see any parameter or value for the upload mode..
    Another questions is that, in RSO2, I define Ztimestamp as my delta field.. But , can I add other field as selection condition in the datasource definition, and has its range table in this function module ?
    Should I change the entries in ROOSOURCE for this datasource ??
    Please let me know your feedback, do you have some concret example for generic delta extraction ?
    Thanks a lot !

  • No purchasing date in delta extraction (2LIS_02_ITM, 2LIS_02_SCL)

    Hi.
    We have been experiencing some issues with delta extraction of purchasing data, using 2LIS_02_ITM and 2LIS_02_ITM.
    In particular, the posting date's field (BUDAT) is not always filled: for example, I noticed that when users set the final delivery flag even if the purchase delivered quantity does not correspond to the whole order's quantity or the flag has been set later than the change of the delivery date, the field (BUDAT) in the delta queue is not filled.
    By this way, the field may be overwritten: however, we need to keep the posting date value.
    I am wondering whether I am correct and, in this case, it is possible to keep that value: however, it seems that the only way is to use a full extraction of data.
    Thanks a lot

    Roberto Negro,
    While filling setup table by using T-code OLI3BW (Purchasing) it is taking very long time.
    Please let me is there any way to rerduce this time.
    We are at BW 7.3 version.
    Regards,

  • Delta extraction for FI (AR & AP) data sources

    I tried extracting the data from 2 standard SAP data sources under FI module for Accounts Receivable.
    0FI_AR_10(Customer payment history via delta extraction)
    0FI_AR_5 (customer payment history)
    The data to be extracted into 0FIAR_C05(payment history) info cube.I assigned the 2 data sources to an info source and pumped the data into the cube via an ODS.Now the problem is with delta extraction.No records are picked in the delta extraction.So I checked in extractor checker RSA3 with delta update mode.I got the following error.
    "Could not determine BW release of logical system"
    Could some one resolve the issue?Thanks in advance.
    Thanks & Regards
    Vinay

    Hi ,
    Please go through 493422 note  once . see if suits to your requirement  follow it  accordingly .
    Thanks ,
    Anil

  • Delta Extraction Hung

    Hello All ,
    Please help in coming to a conclusion .
    The Delta Extraction JOb ( SM37 ) for a load is hung for a long time ( pulls 0 by 0 )  . The job log in R/3 doesnt progress ahead of the step --
    "Asynchronous sending of InfoIDOCs 2 in task 0001 (0 parallel tasks) ".
    When I looked in SM66 for the Process ID - Its is just hung at " UPDATE roosprmsc " step .
    Has any one ever come across the scenario . The datasource used for extraction is a generic datasource which has been running fine for a long time now.
    Thnx

    Hi,
        There is some problem with the R/3 source system.
    Contact yr R/3 counterpart and check if they also  have the same issue with other jobs in R/3.
    Try to pull delta for some other ODS from the source system ad check if it works fine.
    If not contact your Basis guy.
    Also check if Full load is working..
    Regards,
    Balaji V

  • Delta Extraction - Generic Datasource

    Hello Guys,
      I have an issue related with the delta extraction for a generic DS. I have a DS setup with
    a generic delta for a calendar day and safety interval upper limit 1. So i think that for some reason no all values are loaded in the
    delta load. Please help me to find the best approuch for this.
    Regards,
    Iván.

    Hi,
    Hope below links are helpful for you  to find the best approuch
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/84bf4d68-0601-0010-13b5-b062adbb3e33?quicklink=index&overridelayout=true
    Generic delta safty intervals
    Regards,
    Vinay

  • ALE delta extract for HR master data

    We want to create some R/3 delta extracts based on the HR PA* tables using the ALE delta extract function of generic extractor. Has anyone done this before?  Are there any OSS notes or documents that I should look at?  Thanks!

    Hi Bill Faison,
    This is very old message. I think your problem must be solved. If it is not then: yes we can extract Data from R/3 with ALE Delta .
    You have to perform below steps.
    1.     In your Table you need to activate ALE change   pointer.
    2.     Create change documents for required table.
    3.     Created Generic Extractor with ALE Delta.
    Hope this will help.
    Let me know if you have any concern or issue in this regards
    Best Regards
    Sharad Verma

  • Delta extraction for dunning history is not active

    Hi all,
    I am loading data to the FI Cube (Financial A/c -> Contract a/c receivables ) Dunning header .
    This is a Standard infocube.  This cube contains two DSOu2019S  0FC_DS08 , 0FC_DS11.  When I starting the data loading from the DSO ( 0FC_DS08 ), I create the INIT package .  When creating itself it throwing the error  u201C Delta extraction for dunning history is not active u201D
       When I check on SDN SAP , ( Use Tcode sbiw. Select 'Settings for apllication-specific datasources (PI) ->Contract Aacounts Receivable -> Make Central Settings'. Then tick 'Delta Extraction for Dunning Items Active'.) I got this link.  But I could not proceed this link.  Can you explain detailed step by step how to proceed to solve this issue.
    Regards,
    Baskaran.

    Hello Baskaran,
    Did you ever solve this issue?
    We do not have the link in SBIW (ERP 6.0 EHP6).
    Thanks,
    Andreas

  • Safety intervels in genric delta extraction.?

    can anyone expliain me with an example how to set safety intervel limit?how to set upper limit and lower  limit?

    Hello Shilpa !
    Guess this doc will clear ur issues:-
    Safety Interval Upper Limit of Delta Selection
    This field is used by DataSources that determine their delta generically using a repetitively-increasing field in the extract structure.
    The field contains the discrepancy between the current maximum when the delta or delta init extraction took place and the data that has actually been read.
    Leaving the value blank increases the risk that the system could not extract records arising during extraction.
    Example: A time stamp is used to determine the delta. The time stamp that was last read is 12:00:00. The next delta extraction begins at 12:40:00. In this case, the selection interval is 12:00:00 to 12:40:00. At the end of extraction, the pointer is set to 12:40:00.
    A record - for example, a document- is created at 12:40 but not saved until 12:40. It is not contained in the extracted data but, because of its time stamp, is not extracted the next time either.
    For this reason, the safety margin between read and transferred data must always be larger than the maximum length of time that it takes to create a record for this DataSource (with a time stamp delta), or it must display an interval that is sufficiently large (for determining delta using a serial number).
    Safety Interval Lower Limit
    This field contains the value taken from the highest value of the previous delta extraction to determine the lowest value of the time stamp for the next delta extraction.
    For example: A time stamp is used to determine a delta. The extracted data is master data: The system only transfers after-images that overwrite the status in the BW. Therefore, a record can be extracted into the BW for such data without any problems.
    Taking this into account, the current time stamp can always be used as the upper limit when extracting: The lower limit of the next extraction is not seamlessly joined to the upper limit of the last extraction. Instead, its value is the same as this upper limit minus a safety margin. This safety margin needs to be big enough to contain all values in the extraction which already had a time stamp when the last extraction was carried out but which were not read. Not surprisingly, records can be transferred twice. However, for the reasons above, this is unavoidable.
    these are used to determining the delta in a datasource:
    1. Time stamp - The field is a DEC15 field which always contains the time stamp of the last change to a record in the local time format.
    2. Calendar day - The field is a DATS8 field which always contains the day of the last change.
    3. Numerical pointer - The field contains another numerical pointer that appears with each new record .
    also download Generic Delta doc
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/84bf4d68-0601-0010-13b5-b062adbb3e33
    Regards
    Tom.

  • A problem with 1CL_OLIS002 and 1CL_OMAT001 extractors - delta extraction

    Hi
    I have a problem with 1CL_OLIS002 and 1CL_OMAT001 extractors - delta extraction.
    Interrelated extractors: 2LIS_11_VAITM and ZMATBATCH_Attr work well.
    For 1CL's extractors I see current data in RSA3 but I don't see LUWs in RSA7.
    Extractors send 0 records to BW.
    There is no entry in "BIREQU* " job logs like this:
    "Call customer enhancement BW_BTE_CALL_BW204010_E (BTE) with xxx records".
    which I find in job logs when all worked well.
    We had some problems with R3. I had to restart job "LIS-BW-VB-APPLICATION_13*".
    May be it has influence on these extractors?
    Any suggestions about how to resolve the problem?
    Regards
    PWnuk

    Hi
    Can you please share the solution of this problem with me,I am also facing same issue of Delta not working but full load is working in 1CL_OBI_001?
    Edited by: Aseem84 on Jan 12, 2011 10:23 AM

  • Business Partner Items (0FC_BP_ITEMS) delta extraction help

    Has anybody used 0FC_BP_ITEMS extractor? The documentation says that it supports delta, but it needs to be enabled.
    I did enable delta extraction in IMG as SAP help site suggested. However, the documentation also says that before running delta, I need to update/initialize it in tcode FPOP. I go to that tcode, but I can hardly understand what to do in that tcode and there is no help or documentation I can find on how to initialize that delta extraction for 0FC_BP_ITEMS in OLTP system.
    anybody came across any help document on FPOP tcode?
    Thanks

    Have you found a solution to the problems you were facing? is there any documentation you have regarding the BP Items extractor.

  • Error while doing DELTA Extraction

    Hi BW Experts,
    In my R/3, I have a generic data source ZBUT_VW.
    It receives data from a View which is created based on couple tables.
    When I do full load to the corresponding ODS, it is successful.
    But after that I delete the ODS and created CUBE with DELTA
    I have Initialized delta.
    When I do DELTA extraction, it fails.
    The error
    “The ALE inbox of the SAP BW is identical to the ALE outbox of the source system
    and/or
    the maximum wait time for this request has not yet run out
    and/or
    the batch job in the source system has not yet ended.”
    I delete the initialization load and trying to do DELTA extraction again and it Fails With the same error
    Please let me know how can I resolve this problem.
    URGENT
    gaurav

    I dont think it is possible to have to additive delta with creation date.
    Try a full load to cube to check if the extractor is working.

  • Error while doing DELTA Extraction (generic data source)

    Hi BW Experts,
    In my R/3, I have a generic data source ZBUT_VW.
    It receives data from a View which is created based on couple tables.
    When I do full load to the corresponding ODS, it is successful.
    But after that I delete the ODS and created CUBE with DELTA
    I have Initialized delta.
    When I do DELTA extraction, it fails.
    The error “The ALE inbox of the SAP BW is identical to the ALE outbox of the source system
    and/or
    the maximum wait time for this request has not yet run out
    and/or
    the batch job in the source system has not yet ended.”
    I delete the initialization load and trying to do DELTA extraction again and it Fails.
    With the same error
    Please let me know how can I resolve this problem.
    URGENT
    gaurav

    I dont think it is possible to have to additive delta with creation date.
    Try a full load to cube to check if the extractor is working.

Maybe you are looking for

  • How do I resolve "BOOTMGR is missing" on startup of HP TouchSmart IQ816 Desktop PC (VISTA)?

    Product:  HP Touchsmart PC IQ816 Desktop OS:  Windows Vista Home Premium with Windows Media Center (64-bit) with Vista Service Pack 1 Error Msg:  "BOOTMGR is missing" "Press Ctrl+Alt+Del to restart Changes:  No changes have been made to system since

  • XI calling WS via SOAP Adapter

    Hello, does anyone have a working scenario where XI 2.0 calls a WS via the SOAP Adapter? Could you please post the config file and please let me know what you use on the inbound XI side Thanks Stefan

  • Schemas and Parsers

    Hi, i've making a web application and im using xml for some operations.... i have the following problem when try to validate a xml SAXParser parser = new SAXParser(); parser.setFeature("http://xml.org/sax/features/validation",  true); parser.setFeatu

  • Interface pair configuration documentation?

    I want to change up the current config of my 4215 to use two ports for a IPS inline pair pass thru setup. If you have come across the documentation on this I would appreciate if could you link the relevant documentation to your reply. I currently hav

  • 2LIS_03_UM setup required field

    Hi, Guru, I am facing a very strange issue here. When I am in R3 trying to fill the setup table for 2LIS_03_UM, it requires that a value in company code to be provided. We have more than 100 company codes, I really don't want to run setup table by co