Delta Maintenance & Management...

Dear All,
I have about 10 to 12 Process Chains for different "Application Components" that run on daily basis early in the mornings. I have following questions regarding the "Delta Maintenance & Management":
1. How to fetch a request which has not been successfully fetched by "Process Chain" Delta InfoPackage and therefore, have not loaded into the Data Target?
2. How to manage and maintain different Process Chain that runs on daily basis?
3. What are the key points while repairing a failed request; which has not been fetched by Process Chain?
4. Are there certain steps/points which need to be taken care of during the "Delta Maintenance & Management"?
5. How the Process Chain checked or what should be done on daily basis for the checking and maintenance of process chain?
6. Can we add another process into existing Process Chain without any trouble?
I will appreciate your quick responses!
Many Thanks!!!
Tariq Ashraf

Hi Ashraf,
1. How to fetch a request which has not been successfully fetched by "Process Chain" Delta InfoPackage and therefore, have not loaded into the Data Target?
U can run a repair request to fetch the missing data.you should have a tab on safety intervals if the missing is daily scenario.
2. How to manage and maintain different Process Chain that runs on daily basis?
Maintain every thing under master chain based on transaction data and master data.
Run your attribute chain run at once for all your master data
3. What are the key points while repairing a failed request; which has not been fetched by Process Chain?
Check why the chain is failing reasons of lock or table space issues etc,Identify and fix the issues for
delaying the process if two chains are causing the lock
4. Are there certain steps/points which need to be taken care of during the "Delta Maintenance & Management"?
There are many docs on google for each scenario
http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/f0709b9f-acbc-2c10-7a95-ab0ee18b921c?quicklink=index&…
5. How the Process Chain checked or what should be done on daily basis for the checking and maintenance of process chain?
Every day checking is not required.If the process is running from many days identify the long going issues and fix it.
6. Can we add another process into existing Process Chain without any trouble?
Yes you can add.say the data is loading in to three cubes from same dso with different selections and you want to add a new cube and load the data with different selection from same dso u can do it with out any issues.
Thanks,
Sagar.

Similar Messages

  • Problem with Maintenance Manager

    Hello,
    I have a Lenovo T61 6457-E3G wth Windows XP. The Windows is updated on the last available version, and so the lenovo sofware too. 
    Weeks ago, the problem started:
    When I shut down the computer the Lenovo task: "AWAYSCH" can't be closed by windows. (So I have to do that on my one by every shut down)
    Also the Maintenance Manager can't be started (I pushed the Maintenance-Manager button, but the programm will not start, without a problem description). 
    Can some help me?
    Solved!
    Go to Solution.

    Refer to this URL: http://www-307.ibm.com/pc/support/site.wss/document.do?sitestyle=lenovo&lndocid=MIGR-70681
    Seems "AwaySch.exe" does not support most T61s with Intel GM965 video chipsets. This could explain why the application will not launch.
    Message Edited by normyy on 10-10-2008 04:12 AM

  • Question - PeopleSoft Enterprise Maintenance Management

    What PeopleSoft modules have to be installed prior to installing PeopleSoft Enterprise Maintenance Management?

    Thank you Nicolas. Do you know what PeopleSoft modules have to be running before a customer can implement this product? Someone had mentioned that General Ledger has to be installed before Maintenance Management and I wanted to verify if that was true.

  • On "AwaySch.exe is not responding" and Maintenance Manager will not start

    This problem is very likely to be caused by the incompatibility of the program Away Manager on T61 with Intel GM965 video chipsets. If this version is installed, the Maintenance Manager will not launch from the ThinkVantage menu.

    See also http://kb.mozillazine.org/Firefox_hangs and [[Firefox hangs]] (Hang at exit)

  • How to configure Tao Yang's self maintenance management pack

    Hi People,
    I have installed the s self maintenance management pack from Tao Yang.
    When i read the manuel i only see the rules that do something, i don't see the ones i have to enable or how to configure them.
    Has anybody installed the pack before and does it need configuration?
    Kind regards
    André

    Hi,
    I think we should according to our needs to enable those rules as we can see what those rules do.
    Please also go through the links within the below Kevin's blog for more details:
    Tao-Yang's Self-Maintenance management pack for OpsMgr 2012:
    http://blogs.technet.com/b/kevinholman/archive/2014/02/24/tao-yang-s-self-maintenance-management-pack-for-opsmgr-2012.aspx
    In addition, maybe we can leave a reply in Tao Yang's blog:
    http://blog.tyang.org/2014/02/23/opsmgr-2012-self-maintenance-management-pack-update-version-2-3-0-0/
    Regards,
    Yan Li
    Regards, Yan Li

  • Delta datasource management in process chain

    Hi experts,
    I have the following problem with process chains.
    I have one <b>Delta</b> infosource used to load two different infoproviders (ODS1 and 2).ODS 2 must be loaded only once ODS 1 is loaded and activated. The Delta process implies that the <b>2</b> ODS are datatarget for the delta infopackage.
    In my process chain, I have :
    'execute infopackage IFPCK1'
    <i>(with 'only PSA' option and of course the two datatargets ODS1 and ODS 2 selected)</i>
    then a first
    'Read PSA and charge datatarget process'
    <i>(with options : datatarget = ODS 1, execute infopackage IFPCK1)</i>
    followed by
    'Activate ODS' ODS 1
    then a second
    'Read PSA and charge datatarget process'
    <i>(with options : datatarget = ODS 2, execute infopackage IFPCK1)</i>
    Each time, I run the Process chain, I have the following message for <b>ODS 2</b>
    "the request <b>(ODS1)</b> already exists in infocube/ODS; Not loaded."
    It is as if the first Read PSA process tries to load both ODS instead of only one.
    Any suggestion to help me slve this problem ??
    Thanks in advance

    Hi Daniel,
    unfortunately there is no easy way around this. I would suggest to create an ODS 3 as exact copy of the info source and load ODS 1 and 3 in parallel and then ODS 2 from ODS 3.
    Best regards
       Dirk

  • File maintenance/management

    I've recently converted from PC to Mac. I'm revelling in the new environment but I'm learning that Mac's are not without their frustrations also.
    I imported all my photos into the internal hardrive and imported them into IPhoto. It's seems that I must have two copies of the files as the photos must be imported from a location other than the iphoto library. I thought I was clever by deleting the original photos and keeping those in the iphoto library but now iphoto is unable to pick them up. This seems a little silly as at 4mb each it's totally impractical as well as illogical to need two of every photo. Is there a way around this?
    I'm having other problems with file maitenance. when I'm sorting through my latest photo rolls, I decide what to keep and what to delete. Is there a way to delete a file in iphoto which will also delete the photo off the hard drive?
    Would be very grateful for assistance to overcome these difficulties.

    Electric987
    Welcome to the Mac and to the DIscussions
    1. There are two major ways that you can file manage in iPhoto. The default method is that the photos are imported into the application and the actual files are copied to the iPhoto Library Folder. Once you are sure that they are safely in iPhoto you can then delete the files fom elsewhere on your hard drive.
    2. The second way is to leave the files in your own filing system (go to iPhoto Preferences -> Advanced -> Uncheck Copy Files to iPhoto Library Folder when Importing) There are pluses and minuses to either system and they are discussed all over these discussions.
    I don't understand the particular problem that you describe, can you give more detail?
    Everything you need to do, edit (either in iPhoto or another app), sort, arrange, tag, export (file -> export or just drag and drop onto the desktop) and so on can be done through the iPhoto window. iPhoto always works on a copy of the file so that the original is preserved and can be returned to (Photos -> Revert To Original).
    IF you opt for option one, then moving a photo to the iPhoto trash will remove the photo from the Finder when you empty the iPhoto trash. (This gives you the option to change your mind...)
    If you opt for option 2, then you'll have to delete by hand.
    hope this helps
    Regards
    TD

  • SCOM 2007 extest_ user mailbox maintenance/management.

    I use SCOM 2007 to monitor our Exchange 2010 environment.  I use the test-* commands in powershells on my desktop to catch anything that may occur between SCOM alert thresholds.  Several of these use the extest_ account.  
    Today, I looked at the extest_ user mailbox and found that the tests are accumulating in the mailbox.  What do I need to configure so the tests are purged from the mailbox, including the deleted items folder?  
    Information, links, and comments are all welcome.  
    TIA.  

    Hi,
    Do you mean that there are many test mailbox and you want to remove them? As far as I know,  those account is used for synthetic transaction tests for the Exchange. Those synthetic transactions will perform several tests on your Exchange infrastructure
    and warn you if there is a problem with your mail flow. In order to perform such tests the requirement is to have specific users with mailboxes created.  Those users is created by script named New-TestCasConnectivityUser.ps1.
    Each site will have a test account, please refer to the below link for more details:
    http://stefanroth.net/2013/02/09/scom-exchange-2010-mp-extest_-user/
    From my point of view, we can remove those account, but then the script can create them again.
    If you don't create a test mailbox on one or more Mailbox servers, the Management Pack will return the following warning: “The test mailbox was not initialized. Run new-TestCasConnectivityUser.ps1 to ensure that the test mailbox is created.”
    More details:
    http://technet.microsoft.com/en-us/library/ee758052(v=exchg.140).aspx
    Regards,
    Yan Li
    Please remember to mark the replies as answers if they help and unmark them if they provide no help.

  • Critical issue - delta queues for LIS empty after upgrade BW3.5

    The delta queue in R/3 for LIS sources (S260-261-262) remains empty,
    even after a successful init delta. Hence I cannot extract delta
    records.
    BW3.5
    PI2004.1
    Does the BW upgrade has an effet on the delta queue management in R/3 ?
    The previous configuration BW2.0B PI2004.1 did work fine in that
    respect.
    Laurent Querella
    BI Consultant ALTI

    Laurent,
    from OSS Note 534296 'LBW0: DataSource generation possible for SAP info str.' you can read:
    "(...)it is no longer possible to generate DataSources for info structures (transfer) Snn delivered by SAP (where nnn is between 001 and 500) in the BW interface for LIS info structures (TR: LBW0) in the OLTP. (...)The corresponding DataSources are delivered with the Business Content."
    I think this is the issue...
    However, are you saying that all infostructures are empty ?
    And from where your init is taking data ?
    After an init your delta tables have to be empty...did you empty all these tables before doing your upgrade ?
    Bye,
    Roberto

  • Header and Item consolidation delta

    Hi all,
    If I do a lookup on header DSO while loading into a consolidated DSO from a item level DSO, how do we make sure that deltas are managed if only changes occur in the header DSO?
    In this case since the driver is the item level DSO, I would imagine that the delta won't be picked up. Any thoughts?
    Thanks.

    Yes, you still have to do a lookup to the header DSO (in the flow DSO item -> DSO consolidated). You already have this one.
    In the flow DSO header -> DSO consolidated, you have to split the header into the different items existing for this header (kind of "look up" to the item DSO).
    Regards,
    Fred
    [edit] : this is why sometimes we put the header data in a master data (no more delta problem of this kind).
    Edited by: FCI on May 7, 2010 6:06 PM

  • Approved from/to Date Permit in a maintenance order IPM2

    Hy.
    In the list of permits for maintenance orders (transaction IPM2) appears two fields:
        - Approved from Date: Date from which the permit is valid as being issued
        - Approved to Date: Date untill which the permit is valid.
    But I am not able to change these values. Do anyone knows how is possible to add these information to a permit?
    Thanks for your help.

    Hi
    1.     Depending on the application component in which you are working, choose one of the following menu paths:
            Logistics ---> Plant maintenance -> Management of technical objects / Maintenance processing> Environment> Permits
            Logistics ---> Customer service -
    > Management of technical objects / Service processing ->Environment-> Permits
    The overview of all the permits appears.
    2.    Select the required permit and choose Details.
    3.    Make changes as required and save the permit.
    Technical name: SAP_PM_EQM_PERMITS_ISSUE_DISPL
    This role contains all the functions that you require to issue and display permits
    The following activities for permits are available with this role:
    Changing a permit
    Displaying a permit
    Regards from Pakistan
    Edited by: Saif Ali Sabri on Jan 15, 2010 12:35 PM

  • Data Source 2LIS_11_VAHDR deliver rows with mode "Delta init. without data"

    Hi.
    I have the problem, that my datasource 2LIS_11_VAHDR does deliver the full content like mode C even with mode S. Does somebody know about the problem and how to solve it (perhaps OSS).
    Thanks in advance,
    Nils

    To see the delta data, we use trandaction code RSA7. is that right? This is the place i used to view the delta data after every document changes.
    per say: If I have 2 line items in a sales order and I have increased the quantity of one line item and saved it. The delta maintenance transaction shows me 3 records. 2 for changed line item and 1 for unchanged line item.
    Please tell me why I have 3 records of data in delta table.  Please clarify.

  • Delta update in Info package

    Hai all
    what is the us of delta update in info package
    I had intially loaded data from R/3 to psa using
    (INFO PACKAGE->UPDATE-->Initilize delta process)
    Then I had created to more records in  r/3 side .
    this time I scheduled using DELTA UPDATE I am getting 0 records
    then what is the use of delta update
    How can I get only delta records with out use of selection condition in DATA SELECTION of INFO PACKAGE
    thanks
    chaithanya

    Hi,
    You must specify "1" (day) in the lower limit of the delta maintenance.
    I could not post my previous reply so here a new try :
    Hi Chaithanya,
    Let me explain how the generic  delta mechanism with "date"-field works on the R/3 side:
    When doing a delta extraction, the current date is stored in table ROOSGENDLT or ROOSGENDLM (anyway not so important).
    This date will serve as a "from" date for the next delta extraction, though excluding the current value.
    This in order to prevent duplicate records to be extracted during a second delta run on the same day.
    Without extra settings, it will thus not be possible to extract two different delta's on date the same day.
    Solution :
    1. If you do not care about duplicate data (e.g. only field assignments with overwrite functionality in the transformation) goto RSO2 in change mode for your extractor and go into the generic delta maintenance screen. In the settings, enter "1" as safety interval lower limit. Like this, the delta processing mechanism will always subtract 1 day from the day stored as 'low-value'.
    In your example this means that the initialisation will transfer 4 records, the delta will transfer 6 (although only 2 were added).
    2. Use timestamps to determine delta (timestamp should be updated on savetime of record)
    I hope this helps.
    regards,
    Olav

  • What are the costs we collect in maintenance order  and work order

    what are the costs we collect in maintenance order  and work order
    is work order and maintenance order differeent or same

    Usually the main costs of maintenance are the spare parts and labour. And these are the costs we would like to track per maintenance job from a maintenance management perspective. There could also be cases where other costs such as travel to place where the equipment is might be required to be collected in the maintenance order.
    In SAP there is no term called work order. But loosely the term is sometimes used for maintenance or service order. Probably even production orders also.
    thanks
    Bala

  • InfoSpoke Delta - Full loads

    Hello All,
    I have an Infospoke that's in PROD with Delta update sourcing from an ODS.
    We have planned a full load.
    With selection option 06-31-2005 to 06-31-2007
    changed the update mode from delta to full and started the full load on
    06-01-2007 and completed the load successfully on 06-09-2007.
    restored the delta once the data is consumed from the /BIC/OHXXXX tables on
    06-22-2007 (full load was huge).
    During this process of full load, ODS was fed with deltas (load to ODS was not stopped).
    Users are complainig delta data is missing during that period (06/01 - 06/09)in which full load was performed.
    Can someone throw some light on why did the delta data is missing only for that period? Is not putting the ODS load on Hold the reason for this failure which messed up the delta pointer.
    Full points assured.

    Hi,
    enabling delta load:
    chk the below link for step by step instructions
    http://help.sap.com/saphelp_nw04s/helpdata/en/44/97433e99ee70dbe10000000a1553f6/frameset.htm
    which describes:1.Delta Load Management Framework Overview
    2.Enabling Delta Load
    3.Initializing Delta Load

Maybe you are looking for

  • Vision Builder Crashes Labview

    I have an application where I need to acquire and inspect many high resolution images 3Mp at high throughput.  I'm using: LabVIEW 8.5.1 NI-Imaq 4.1 Imaqdx 3.2 Vision Builder AI 3.6 ISG 3Mp Camera through Startech 1394a PCI card In order to meet the c

  • Exchange rate diffrences for procurement

    Hi Group I am trying to use SAP note 164505 to differentiate my actual PPV and Exchange rate diffrences. I changed my set up but still my entries are not changed at the time of Invoice. As per SAP system will change entries at the time of Invoice and

  • How do I make a clipping mask static?

    I have a group of objects that move around within a 700x500 px artboard. The size of one object within this group is a map that spills over outside the artboard. I want this group to only be 400 px high, but not change anything withing the group. Jus

  • After updating, I receive a not responding message, and then it freezes

    after upgrading to firefox 6, I now continuously receive a "not responding" message at the top of page, and it freezes. I have disabled all add ons, but connot run some things. I have a lot of trouble playing games on facebook, because it freezes up

  • Working time...

    Hi, In IMG orgnization managment i found working time which is used for defaulting working times for organization unit,positions or work centers. so plz tell me what is the exact use of this & where can we see the effect of it. is it possible to use