Delta Status in ODS is incorrect

Hi,
I am loading a delta load to an ODS. Today its activation got failed giving message "FAULTY STATUS FOUND FOR DSO, ACTIVATION TERMINATED".
I tried to activate it manually but it is failing giving the same error.
Also I tried t repeat delta by deleting this red request (by making it RED in monitor-->status tab and its QM statu(which is already REd) but this deletion job is also failing giving the same error.
It is also giving messgae"The request is already PARTIALLY activated.No further changes to QM action".
I am unable to find out how to correct it? please help.
Thanks,
Preet

I could delete the red request finally from 4 tables, namely:
1. RSICCONT
2. RSMONICDP
3. RSODSACTREQ
4. RSODSACTUPDTYPE
It got deleted successfully. Then I reconstructed it. But again the problem occured saying 10 duplicate requests found. Cannot activate. Its activation failed after sometime giving message"Partially activated , cannot change the QM status further".
I dont know how to tackle with this now.I have checked in PSA also, there is no bad records present.
Please help.

Similar Messages

  • Get back the Data mart status in ODS and activate the delta update.

    I got a problem when deleting the requests in ODS.
    actually there is Cube(1st level. it gets loaded from an ODS(2nd level). this gets loaded from 3 ODS'S( 3rd level). we were willing to delete recents requests from all the data tardets and reload from PSA. but while delting in the request in ODS(2nd level), it has displayed a window, showing as follows.
    - the request 132185 already retrived by the data target BP4CLT612.
    -Delta update in BP4CLT612 must be deactivated before deleting the request.
    - Do you want to deactivate the delta update in data target BP4CLT612.
       I have clicked on execute changes in the window. it has removed the data mart status for all the request which i have not deleted.
    in the same it happened inthe 3 ODS's(3rd level).
    I got clear that if we load further data from source system. it will load all the records from starting.
    so to avoid this can any body help me how to reset the Data mart status and activate the delta update.

    Hi Satish,
    U have to make the requests RED in cube and back them out from cube,before u can go for request deletions from the base targets(from which cube gets data).
    Then u have to reset data mart status for the requests in your 'L2 ODS' before u can delete requests from ODS.
    Here I think u tried to delete without resetting data mart status which has upset the delta sequence.
    To correct this..
    To L2 ODS,do an init without data transfer from below 3 ODS's after removing init request from scheduler menu in init infopackage.
    Do similar from L2 ODS to Cube.
    then reconstruct the deleted request in ODS.It will not show the tick mark in ODS.Do delta load from ODS to Cube.
    see below thread..
    Urgentt !!! Help on reloading the data from the ODS to the Cube.
    cheers,
    Vishvesh

  • Delta loading from ODS to InfoCube

    Hai
    Im extracting the data from the custom table into ODS and doing full load everytime for loading delta.
    how can load the only delta from the ODS to InfoCube. what are the setting for this one
    pls let me know
    kumar

    Hai <b>Ravi</b>...
    <u><b>Load the Data From ODS to InfoCube</b></u>:
    Clck as right Click in the Specified ODS.....
    Select the Option " Update ODS Data in Data Target "......
    Then You able to load the Data to any type of DataTarget's(either ODS, InfoCube)
    <i><b>removed</b></i>...
    <u><b>BalajeeKannan</b></u>

  • Help with DTP with Processing Mode No Data Transfer, Delta Status in Source

    Hi, I am trying to test a Cube to Cube Extraction where I do a full DTP Extraction for a specific account to get the data I need and then a DTP Delta Init by using Processing Mode "No Data Transfer, Delta Status in Source".  
    When I do the DTP Delta init using Processing Mode "No Data" this is done in Dialog mode, but is taking an extrodinarily long time to run as it looks like it is going back through all of the source infocube requests to somehow determine the delta marker.  The source infoCube does have a lot of requests, but I would think this would be a very quick process to set the marker.
    Any ideas why this dtp init delta with no data would take soooo long?

    Hi,  Thanks for the information, but I see in the documentation that this type of proces is run in dialog mode.  Could you point out where this process type would run in background only?   Can anyone tell me why this would run so long?
    No data transfer; delta status in source: fetched
    With this processing mode you execute a delta without transferring data.
    This is analogous to simulating the delta initialization with the InfoPackage.
    *In this case you execute the DTP directly in the dialog. *

  • Error in loading delta request to ODS

    Dear All,
    i am not being able to load data from ODS to another ODS and Cube. It is saying "the last delta update was incorrect therefore, no new delta update possible".
    i guess i need to delete the old delta update request.
    can you all help me. its a bit urgent.

    i have done all the possible steps as guided by you all. i am still not being able to load it.
    i will tel you my process flow:
    i have a process chain which is loading data to source ODS and subsequently to another ODS and Cube.
    But there was an errror in loading the data to source ODS today. So i deleted the request from the source ODS and from the other ODS and CUBE.
    Now i loaded data to source ODS successfuly. and tried loading data from source ODS to other ODS and CUBE.
    But the request ended with errors. so i deleted the request again from target ODS and CUBE.
    Now when i m again loading data to target ODS and Cube then it is saying
    1) "Delta request REQU_CGSYNH9QR02W5WZOQBDPTHP99 is incorrect in the monitor"
    2)A repeat needs to be requested
    3)Data target 0CRM_C04 still includes delta request REQU_CGSYNH9QR02W5WZOQBDPTHP99
    4)Data target 0CRM_OPMO still includes delta request REQU_CGSYNH9QR02W5WZOQBDPTHP99
    5)If the repeat is now loaded, then after the load
    6)there could be duplicate data in the data targets
    7)Request the repeat?
    CONTINUE CANCEL
    what do i do now?

  • Delta loading daily ods to cube

    HI guys
    delta not laoding to ods to cube.last laoding in ods 3 /06 .
    when m try to loading m getting erorr
    subseq. processing(messages) : errors ocuured
    Activation of M records from DataStore object 0FIGL_O10 terminated ,
    REquest REQU-D3k2lr788qjc4g9w7h8fwbnhk(2.130) has not or not c0rrctely updated;p
    same msg showing in
    other (messages ): errors occurred
    Diagnosis
        Request REQU_D3K2IR788QJC4G9W7H8FWBNHK (2.130 ) for DataSource 0FI_GL_10
        from source system P02CLNT800 has the status green and a lesser SID (and
        is therefore older) than the request that you currently want to update
        into the DataStore object.
        This is not possible because the sequence of requests has to be
        followed.
        Delta- and init requests have to be updated to the DataStore object in
        the request sequence.
    please advise on this
    Regrds
    patel

    Patel,
    Go to RSRQ. Give this request no. REQU_D3K2IR788QJC4G9W7H8FWBNHK. There you will find the message that this request has not been properly updated. You will find a button to update the request. Update this to the data target and activate. You will be thru this time.
    Enjoy!!
    Shambhu

  • Delta load from ODS to cube failed - Data mismatch

    Hi all
    We have a scenario where the data flow is like
    R/3 table - >dataSrc -- > pSA - >InfoSrc -> ODS ->Cube.
    The cube has an additional field called "monthly version"
    and since it is a history cube , it is supposed to hold data
    snapshots of the all data in current cube for each month .
    We are facing the problem that the Data for the current month
    is there in the history ODS but not in the cube . In the ODS ->Manage->requests
    tab i can see only 1 red request that too with 0 recs.
    However ,In the cube -> manage-> reconstruction tab , i can see 2 Red request
    with the current month date. Could these red requests be the reason for
    data mismatch in ODS and cube .
    Please guide as to how can i solve this problem .
    thanks all
    annie

    Hi
    Thanks for the reply.
    Load to Cube is Delta and goes daily .
    Load to ODS is a full on daily basis .
    Can you help me how to sort this issue . I have to work directly in production env . so has to be safe and full proof .
    Thanks
    annie

  • Delta load to ODS taking too much time

    Hi,
    I have one delta load running everyday to ODS .its getting data from R3 & its taking too 3-4 hours daily.due to this data is not getting updated in cube on time and there arises issue with data in Reports
    Please let me know what are possible solution to check this ODS Delta load and improve its loading time
    thanks
    nilesh

    Please check if the extraction is taking more time in R/3 or data loading is taking more time in BW. If R/3 extraction is taking is more time, try creating indexes on R/3 tables.
    -Vikram

  • How to intialize delta for another ODS with same infosource

    Hi Experts,
                    We have one ODS having update routines , daily  DELTA loads are ruuning in production system.Now we got one requirement like need to develope another ODS with different update routines on the same infosource. is it possible ? if we do means is there any effect for 1st ODS ? please suugest me how to do that ..its in production system ...little bit urgent..
    Thanks & Regards
    pcrao.

    hi,
    just create another ods2 ,but take the infosource as template and then at the time of update rules ,take again infosource as template.ok.
    and then go for creating infopackage and schedule it.
    before scheduling check the time of scheduled time for the ods1 as one of our frnds said.
    if u want any update routines first do them before scheduling.
    thatsit..

  • Error when doing a delta to an ODS without Init

    Hello All.
    We have a flow for 0FI_GL_4 done an active with delta loads.
    Now we have created anew flow for that ODS and inlcude the old delta loads to the new Flow, but we are getting error RSM1 147.
    Does anyone had this problem before?
    Thanks and best regards
    Alfonso.

    Hello All.
    First thanks for the help.
    Our scenario is as follows. We have an ODS with it´s delta initialization and delta running. Then we have created a new ODS and we don´t want to stop the previos delta initialization, because that will mean to reload all the data.
    Any ideas?
    thanks,
    Alfonso.

  • Delta error in ods

    hi experts,
    if delta load fails b/n ods &infocube
    how to rectify that , for that what is the procedure
    when we are loading the data ods to infocube how to choose the
    keyfields?is it equal to dimensions
    thanks in advance
    venu

    Hi,
    It's the same procedure which we follow for the delta from R/3 to the Bw targets.
    The only thing is if you can correct it in the PSA then you can correct it there and then load it from there.
    Or you can delete the failed delta request from the cube and relaod the delta
    it will give you warning that you are repeating the delta.the new delta will bring the records from the failed delta as well as the records from the new delta if any.
    Th key fields of the ODS are not equivalent to dimension.
    Dimension are for the logical groupings of the objects and are decided in such a way that the size of dimension table should bve as small as possible.
    Where as the key fields of the ODS are like the keys of the table if you want to identify a particular value with respect to a char or combination of char.just imagine it as a table with keys.
    hope it clears
    Thanks

  • Delta Update for ODS

    Hi,
    We have created a view on R/3 side based on MARA and MARC. Using this view created a Datasource in R/3 side with Generic Delta on Matnr Field as a numeric pointer and safety interval Lower limit = 10.
    In BW Side we have replicated the datasource and in the transfer structure mapped all the datasource fields with ODS Fields. But 0RECORDMODE is not mapped. Not sure what needs to be mapped to this field.
    When i execute the Delta Infopackage the changes in not reflected in the ODS. Can any one help me in this.
    Regards,
    Subbu

    Hi,
    If you want the information from MARA and MARC then you dont have to create a view on these 2 tables. Its because, 0MATERIAL gets data from 0MATERIAL_ATTR and 0MATERIAL_TEXT which gets data from MARA and MAKT respectively. For MARC, you have 0MAT_PLANT in BW which gets the data from 0MAT_PLANT_ATTR and 0MAT_PLANT_TEXT in R/3. So try to use these 2 info objects delivered by SAP. If you want to report on both of them then you may go for an infoset in BW may be. Anyways, even if you create a view on these 2 tables, you will get only the common materials from them or you can say only the Materials from MARC as MARA has all of them and in addition you may have few more in MARA. But if you use an infoset in BW and join them by using Left Outer join, you will get all the material numbers from MARA.
    Hope it helps...

  • SPA112 / SPA122 Report Rule - Delta / Status outputs

    Hi,
    I've been playing with the Report Rule and the documentation is not very clear when it comes to the two report options: --delta and --status
    If I set the Report Rule to [--status]http://myserver/posthandler.php, I see the request coming in but the content of the POST is the actual config file (flat-profile) instead of the status (flat-status). Same goes when using the --delta
    I am using 1.3.1 to test but I am sure 1.3.2 is probably not working as well.
    Have anyone ever been able to generate a delta and/or get the content of the ATA status.xml file? I can get it from the URL (http://my_ata_ip/admin/status.xml) but would be neat to get it remotely too.
    Thanks,
    Benoit

    I assume you are following Cisco SPA112, SPA122, SPA232D Analog Telephone Adapters Provisioning Guide
    I see no --status nor --delta modifiers mentioned in Report_Rule option description. Just --key modifier is described here.
    It seems that neither --status nor --delta modifiers are supported on SPA1[12]2.
    As far as I know, status and delta reports are supported on SPA IP Phones (e.g. SPA[35]xx) only.  The --delta is supported from 7.4.9c firmware onward, the --status has been introduced with 7.5.3 version. See Cisco Small Business IP Telephony Provisioning Guide for more information related to provisioning of this product line devices..
    Rate useful responses. It will help others to found solutions.

  • Cube to cube data transferred ,and delta status

    Hi Gurus
    I need to do Portioning in cube
    I have a cube Zaa_c01 which is updated by two data source ZDS1 and ZDS2 (Delta Update) I copy the Zaa_c01 and I created new cube Zaa_c02, also I transferred the data to that. But it is shoeing in single request in cube, after partion I again reloaded to ZAA_C01 , know I am seeing only single request in a cube.
    Whether I lose delta in this case , or I am missing any step, this activity I done in Development, and need to do in production. 
    Regards
    Shashi

    Hai Shashidhar,
    Partitioning is split the large dimensional cube into smaller cubes.... regarding performance point of view we have to do this partitioning.
    there are two types of partitioning..
    1. Logical Partitioning.
    2.Physical Partitioning
    physical partitioning is done at Database level . and logical partitioning done at Data target level.(EX: Info cube level)
    Cube partitioning with time characteristics 0calmonth Fiscper is physical partitioning.(so, we need at leats one of the above time charecterstics for doing partioning...).
    Logical partitioning is u partition ur cube by year or month that is u divide the cube into different cubes and create a multiprovider on top of it.
    STEPS :
    SELECT YOUR CUBE.. AND DOUBLE CLICK IT..->
    in the menu's select EXTRAS menu--> in that select -->DB PERFORMANCE sub menu..-> in that again select Partitioning sub menu..
    and specify how many partions you want to do...
    but you cube should be contain atleast ocalmonth or phical varient should be there...
    Prerequisites
    You can only partition a dataset using one of the two partitioning criteria ‘calendar month’ (0CALMONTH) or ‘fiscal year/period (0FISCPER). At least one of the two InfoObjects must be contained in the InfoProvider.
    http://help.sap.com/saphelp_nw04s/helpdata/en/8c/131e3b9f10b904e10000000a114084/frameset.htm
    Thanks,
    kiran.

  • My Bestbuy reward status changed and is incorrect

    I just logged into my account for first time in over month and I see Best Buy moved me from premier silver to basic and I spent well over the $1500 requirement last year.  I know many and i mean many of my purchases never got credit for reward zone points after the changes best buy made to policy when using points or finanacing offers but to not get the credit for the items being purchased $$$$ wise makes it horrible customer service.   Also I see all my points I have been saving up with the points banking option for points has removed my points and gave me a coupon I dont plan on using in time you have set it up to expire and I am asking and expecting this situation to be fixed.  I just dont understand how best buy can keep messing up this program and expect its customers to stay loyal.

    Hi goku8169, and thank you for reaching out to us on the forum,
    The My Best Buy™ program recently went through its downgrade process, so if your account does not have Elite or Elite Plus status, then you may not have qualified. To have requalified for Elite Plus status during the 2013 calendar year, you would need to have spent $2500 on eligible BestBuy.com and Best Buy store purchases.  If you spent $1500 in 2013, then you should have qualified for Elite status, which would still allow you to bank points.
    I used the email address you registered with the forum to review your My Best Buy™ account, and I believe that I can clarify what status your account should have.  To go over your account in greater detail and ensure it is in-fact up-to-date, I will be sending you a private message.  You can check your private messages by logging into the forum and clicking on the envelope icon located at the top of the page.  I look forward to further speaking with you.
    How to Keep Your Account Active
    Best Wishes,
    Derek|Social Media Specialist | Best Buy® Corporate
     Private Message

Maybe you are looking for