Delta upgrade of ST-SER_700 2008_1

Dear all,
I am trying to import component ST-SER_700 2008_1 in our Solution Manager. I had an error "OCS package SAPKITLOIB does not match the current software vendor". This was because I had already imported ST-PI 2008_1_700 in solution manager. I applied sap note 608277 and solved the issue.
However, I then proceeded with the AddOn delta upgrade queue and it failed in phase ADDON_CONFLICTS. In the action log of the queue I found the following error message:
" Import phase 'ADDON_CONFLICTS_?' (07.04.2009, 15:59:46)
Internal error: OCS_GET_OVERSHOT_TASKS: SAPKITLQI6 does not exist in PAT03
Abort the import due to an error situation (07.04.2009, 15:59:46)"
I looked in sapnet but I didn't find anything relevant. Do you have any ideas on how to overcome this problem?
Thanks,
Filippos

I have installed ST-PI 2008_1 that's why I had to apply note 608277. In that note it explains what to do, which I did, if you have imported  ST-PI 2008_1 prior to ST-SER_700 2008_1.
My active component now is ST-PI 2008_1_700 and not ST-PI 2005_1_700.
However, in phase ADDON_CONFLICTS of the import It looks for SAPKITLQI6 which is the sixth patch of component ST-PI 2005_1_700.
Any ideas on how to overcome this problem?
Thanks,
Filippos
Edited by: Filippos Sempepos on Apr 7, 2009 5:13 PM
Edited by: Filippos Sempepos on Apr 7, 2009 5:16 PM
Edited by: Filippos Sempepos on Apr 8, 2009 10:42 AM

Similar Messages

  • Issues after delta upgrade ccm 1.0 to ccm 2.0

    Hello,
    After a delta Upgrade of CCM 1.0 to CCM 2.0 SP12 i have issues that i show down below:
    1º issue
    I´m trying to do the upload of a schema into the master catalog for the first time but it´s not finish as show the exemple below:
    Uploading catalog /CCM/MASTER_CATALOG 
      Name of file that was uploaded: C:Documents and SettingsadminMy Documentsexport.csv 
      15.09.2008 17:43:51 (UTC+1): Starting CSV import for catalog /CCM/MASTER_CATALOG 
      15.09.2008 17:43:52 (UTC+1): 0001 package(s) were processed OK 
      15.09.2008 17:43:52 (UTC+1): Package 0001 received and saved 
      15.09.2008 17:43:52 (UTC+1): processing of package 0001 started 
      15.09.2008 17:43:53 (UTC+1): catalog header data updated 
      15.09.2008 17:44:30 (UTC+1): 311 data types updated/created 
      15.09.2008 17:45:15 (UTC+1): characteristics updated; 316 updated/created; 0 deleted 
    2ºissues
    On SAP authoring tools the options create procurement catalog, create supplier catalog and display log, they give me BSP Application Error Runtime.
    3º issues
    I am facing some sintax on class and they are class and methods missing.
    Please can somebody help me?

    For Batch jobs -- Try analyzing your database schema's referred by batch jobs. Also look if you have suff o/s resources as recommended by oracle for running Oracle 9i software.
    For backups -- Check the size of your dmp file before upgradation and after upgrading to 9i. If you do not find major diff in size then it could be a resource issue like cpu usage / io / memory.
    Thanks,
    http://askyogesh.com

  • What is the difference between Delta Upgrade and Supplementary Upgrade

    What is the difference between Delta Upgrade and Supplementary Upgrade?
    thanks
    druva

    Hi,
    Delta Upgrade - means installing the different add-on release on the same BASIS release.
    ex: If you have add-on ERECRUIT 600 on SAP_BASIS 700 and want to upgrade to ERECRUIT 603 on SAP_BASIS 700, then its called Delta- Upgrade
    Supplementary Upgrade - means installing the different add-on release on the different BASIS release.
    ex: If you have add-on ERECRUIT 300 on SAP_BASIS 640 and want to upgrade to ERECRUIT 603 on SAP_BASIS 700, then its called Supplementary Upgrade.
    Regards,
    Mahesh
    ps: close the thread so that it wil be helpful for others later

  • MOVED: K7N2 Delta Upgrade Power Off Problems

    This topic has been moved to AMD SocketA based board.
    K7N2 Delta Upgrade Power Off Problems

    Thanks for the various suggestions.  I can confirm:
     - 4 pin cpu power plug connected
     - front bus frequency changed to 200MHz, processor now recognised correctly as Athlon xp3200+
     - I have been assured the cpu has not been overclocked
    However power off problem persists.  System shuts down after approx 1 minute whether i am in BIOS or start initiaiting xp repair from CD.  As the system shuts down after such a short time the xp repair will not complete. The system wil not power on again until at least 15mins has elapsed then promptly powers off again.
     I have fitted the D-bracker diagnostic tool and this shows 'operating system booting', ie four green lights.
    I note from the motherboard maunal that a cpu thermal protection system is installed for the Athlon cpu platform.  If the mechanism senses an abnormal temperature rise it automatically shuts down the system.  As noted in my original post the system is powering off with the cpu temp at <40 deg C.  The cpu warning temp in the BIOS PC health check stsus facility is set at 60 deg C so do not think this is the issue?
    System details:
    MSI K7 N2 delta (MS-6570)
    Athlon xp 3200+ (AXDA3200DKV-4E)
    Corsair twinX 1024-3200C2 DDR-DIM 1024 MB
    Seagate ST340016A 40MB HDD
    Pioneer DVD Rom
    Generic CRD - BP1500P CD
    1.4MB mitsumi FDD
    Thermal take TR2 470W psu
    Coolermaster xdreamII socket A cpu fan
    Gigabyte geforce 6600GT turbo video
    soundblaster live 5.1
    Anyone any further thoughts?

  • K7N2 Delta, upgrade to Win XP, no sound

    I have a K7N2 Delta with Nvidia Nforce2 and onboard 5.1 sound, Athlon XP 1.25Ghz
    I upgraded from Win98se to Win XP Pro yesterday.  I have the full install version ("for Win95 or earlier or PCs without windows") but it allowed me to install as an upgrade.  It warned me that there would be a problem with the sound... and now that I've upgraded, I don't seem to have any sound installed at all.
    One of the things that I've tried is to download the latest audio package from Nvidia's web site at http://www.nvidia.com/object/nforce_audio_4.57_win2kxp
    When I click to Open this program, Win XP wants to open it with Win Media Player (I have no idea why).  When I instruct the computer to unzip it using an actual zip utility, I end up with a folder with a bunch of files, including two uninstaller programs, but no installer program or any explanation of what I'm supposed to do next.  When I try to install a new program from the control menu and direct it to this folder, Win XP itself is confused because it can't find an installer program.
    I'm not entirely sure that this will solve my problem in any case, but their drivers were reccomended by someone on the City of Heroes boards who had a similar-sounding problem.     When I look at sound in the control panel it appears that nothing is installed, so I assume that installing the right drivers would solve my problem.  Only I can't seem to get there from here...

    Hi,
    Jacoband: You may like to start your own thread with this question!  
    You might also like to inform us of what hardware you are using - it would be interesting to know which motherboard you have as you haven't mentioned it!
    You need to make a list of all your hardware and then repost.
    Btw, I'm guessing here but to answer your question I'm pretty sure the answer is no! The jumper position only allows for use of front or back....not both!
    But as I say as I don't know what you're using so I can't be sure!
    Axel  

  • [nForce] K7N2 Delta Upgrade Possibilities

    I think I fried the AGP slot on my K7N2 Delta-L mobo and was looking to upgrade to a new board, perhaps the Delta 2 Platinum.  Would there be any conflicts with using my old peripherals/modules from the old mobo if I upgraded?  Here is what I currently have installed:
    Athlon XP 2700+ 333FSB
    Nvidia 6600
    2X 512 Corsair XMS2700 CL2
    Soundblaster Live Platinum w/LiveDrive
    Oh and if you can think of any way of troubleshooting my old board that would definitely be appreciated.  (Swapped out video cards and still no signal going to the monitor.  Swapped monitor and cables as well and still no picture.) 

    There were a couple things that were awry.  I was going to swap a fan in my case and it was daisey-chained off the supply that also went to my video card.  I am almost positive that my PC was unplugged when doing this.  I unplugged the fan and then booted back up.  Windows came up but all of the graphics were a shade of blue.  I quickly shut down and checked everything and it appeared that my VGA line was not secured properly(I had recently moved my PC).  Resecured it and replug the fan and received no signal to the monitor.  I swapped out my video card with my old one and still no signal.  Attached my PC to a different monitor and cable and again no signal.
    Any ideas?  I will check the d-bracket when I get home from work today and see if it is reporting anything unusual.

  • Kt6 delta upgrade - compatability ?

    I am in the process of upgrading my motherboard, processer & CPU.
    I would to like to make sure that everything is going to be compatible, as well as what problems i have to be weary of with this system as i have never done this before.  
    The components i propose to buy are:
    MSI KT6 Delta LSR,
    Athlon 2500+ (Barton),
    Crucial PC3200 512 MB ram(CT6464Z40B).
    This is to go with:
    MSI FX5200 VGA,
    SB Live Plat/Drive II,
    20 GB IDE (Samsung) & 40GB IDE (Maxtor),
    Pyro DV 1394 Firewire Card (For video editing)
    DVD/CD-RW (Memorex), 56 k Modem (Diamond)
    Win 98se
    ...and the dreaded '550W' Q-TEC PSU (equivalent to ~400W )  
    Any comments or advice would be most appreciated.

    Im in the process of upgrading too.
    Should beable to run the 2500+ at 2.2Ghz , i dont think ya have to unlock it either coz it has a
    Might be better off getting LL PC3500 like Hyper-X or OCZ platinum. 1 512MB stick of that stuff can do 2-2-2-5-1 with all turbo settings enabled. (I can only get the Hyper-X here, but i have read reviews on it until the sun rises, and it has Turbo ability's baby)
    You can only use a maximum of 2 x 512MB sticks (4 banks for DDR400 addressing, but that also means 2 x 1024MB stcks of ram etc.) Use DIMM 1 & 2.
    Watch your PCI card placement for IRQ conflicts. 2 devices per IRQ is optimal.
    Win98se..................get real.
    Expect major problems. I think with the upgrades, you should also get WinXP home edition at least.

  • ST-PI 2008_1_700 upgrade fails on Lower Level SP

    Hello all,
    We are trying to upgrade our ST-PI component for an ECC 6.0 EhP4 SPS 06
    system for end result of connecting/ being managed by our SolMan EhP1 SP25 SLM
    system
    Current: ST-PI 2005_1_700 SP06
    Target: ST-PI 2008_1_700 SP03
    The error we receive is: Request/task SAPKA70001 does not exist
    We are currently on:
    SAP_ABA 701 0006 SAPKA70106
    SAP_BASIS 701 0006 SAPKB70106
    We are on EhP4 SPStack 06 on most components in the managed system, our Solution Manager is EhP1 SP25
    I have tried using KITLRDA (install), KITLRDG (supplement upgrade) and
    the main one KITLRDB (upgrade) and all fail or KITLRDG is not
    recognized at all.
    All with KITLRD1, KITLRD2, KITLRD3       
    Steps taken:
    Tcode SAINT
    Load packages KITLRDB, KITLRD1, KITLRD2, KITLRD3 in SAINT OCS queue
    Select target KITLRD3 003 > KITLRDB 000
    Continue-->
    Error: Request/task SAPKA70001 does not exist
    During phase ADDON_CONFLICTS_?
    Have already entered a SAP message, and there is no information on this error anywhere I can find. Any help resolving this and moving forward with my add-on upgrade would be appreciated.
    Thank you

    Hi
    since you already have add on ST-PI 2005_1_700, please proceed with the delta upgrade cd for ST-PI 2008_1, and apply the latest patch for the same
    Please refer SAP Note 1228898 - Installation/delta upgrade of ST-PI 2008_1.
    as per that you could use SAPKITLRDB KITLRDB.CAR please check
    Jansi

  • ERP5.0 to 6.0 upgrade-SAPup stuck after MAIN_SHDRUN/DDIC_UPG got canceled

    Hi Experts:
    We are currently upgrade SAP ERP 5.0 to ERP 6.0 EHP4 SR1 ABAP Based on SAP NW 7.0 eph1. During the upgrade, the SAPup process was canceled at MAIN_SHDRUN/DDIC_UPG phase of Preprocessing roadmap step by SIDadm. After that, it doesnu2019t allow user to continue or reset this step. The error message from SAPup.log is pasted below:
    CURRENTPHASE MAIN_SHDRUN/DDIC_UPG
    ...started at 20110316230706
    Reading Parameter File "C:\usr\sap\DEV\upg\abap\bin\APPEND.APP" at 20110316230706
    ...begin processing at 20110316233243
    -> received signal Ctrl C from keyboard and exited at 20110317021613
    ...CANCELED at 20110317021613.
    ...CANCELED at 20110317021613.
    Error message set: 'System error: Invalid access to memory location.
    ************************* SAPup started in UPGRADE mode *************************
    This is SAPup version 7.10/7 patch level 31.022 compile time 01:28:19 Sep  3 2010.
    This is UNICODE SAPup!
    Running in graphics mode batch.
    WARNING line 8029 in SYS file: Unknown id in line '4646     "20012" SFX;20110316233243;20110317021613;"";"C:
    usr
    sap
    DEV
    upg
    abap
    exe
    :MY'
    ERROR line 8030 in SYS file: Missing id in line '     "20012" SFX;20110316233243;20110317021613;"";"C:
    usr
    sap
    DEV
    upg
    abap
    exe
    :MY'
    Below is our system information:
    Database: Microsoft SQL Server 2005   9.00.4035
    Operating system:  Windows Server 2003 R2, Enterprise x64 Edition SP2
    Source System
    Release:  SAP ECC5.0
    Kernel:  640 patch 247
    R3trans version:  6400.364.18.43311
    Tp version:  6400, 352, 18, 23218
    Disp+work u2013V: 6400, 247, 15, 22555
    Support Pack Level:       
    SAP_ABA     640     19     SAPKA64019     Cross-Application Component
    SAP_BASIS     640     19     SAPKB64019     SAP Basis Component
    PI_BASIS     2005_1_640     9     SAPKIPYJ69     Basis Plug-In (PI_BASIS) 2005_1_640
    ST-PI     2008_1_640     0          -     SAP Solution Tools Plug-In
    SAP_BW     350     19     SAPKW35019     SAP_BW 350
    SAP_APPL     500     15     SAPKH50015     Logistics and Accounting
    SAP_HR     500     5     SAPKE50005     Human Resources
    EA-IPPE     300     4     SAPKGPIC04     EA-IPPE 300: Add-On Installation
    PI     2004_1_500     14     SAPKIPZI6E     PI 2003_1_470 : Add-On Delta Upgrade
    EA-APPL     500     5     SAPKGPAC05     SAP R/3 Enterprise PLM, SCM, Financials
    EA-DFPS     500     5     SAPKGPDC05     SAP R/3 ENTERPRISE DFPS
    EA-FINSERV     500     5     SAPKGPFC05     SAP R/3 Enterprise Financial Services
    EA-GLTRADE     500     5     SAPKGPGC05     SAP R/3 Enterprise Global Trade
    EA-HR     500     5     SAPKGPHC05     SAP R/3 Enterprise HR Extension
    EA-PS     500     5     SAPKGPPC05     SAP R/3 Enterprise Public Services
    EA-RETAIL     500     5     SAPKGPRC05     SAP R/3 Enterprise Retail
    P3A     V500     7     SAPKIAF507     P3A V500 : Add-On Installation
    ST-A/PI     01K_ECC500     0          -     Application Servicetools for ECC 500
    Target System 
    Release:  SAP ERP 6.0 Including Enhancement Package 4 Support Release 1 ABAP
                Based on SAP NetWeaver 7.0 Including Enhancement Package 1
    Kernel:  701 32
    R3trans version:  7010.129.18.43264
    Tp version:  7010.124.18.35265
    Upgrade type:  High resource use (archive off)
    Support Pack Level:       
    SAP_BASIS     701     0          -     SAP Basis Component
    SAP_ABA     701     0          -     Cross-Application Component
    PI_BASIS     701     0          -     Basis Plug-In
    ST-PI     2008_1_700     0          -     SAP Solution Tools Plug-In
    SAP_BW     701     0          -     SAP Business Warehouse
    SAP_BS_FND     701     0          -     SAP Business Suite Foundation
    WEBCUIF     700     0          -     SAP WEBCUIF 700
    SAP_AP     700     0          -     SAP Application Platform
    SAP_HR     600     0          -     Human Resources
    EA-IPPE     400     0          -     SAP iPPE
    EA-GLTRADE     600     0          -     SAP Enterprise Extension Global Trade
    FINBASIS     600     0          -     Fin. Basis
    EA-RETAIL     600     0          -     SAP Enterprise Extension Retail
    EA-PS     600     0          -     SAP Enterprise Extension Public Services
    EA-FINSERV     600     0          -     SAP Enterprise Extension Financial Services
    EA-DFPS     600     0          -     SAP Enterprise Extension Defense Forces & Public Security
    EA-APPL     600     0          -     SAP Enterprise Extension PLM, SCM, Financials
    EA-HR     600     0          -     SAP Enterprise Extension HR
    FI-CA     600     0          -     FI-CA
    SEM-BW     600     0          -     SEM-BW: Strategic Enterprise Management
    P3A     V604     4          -     P3A V604 : Add-On Installation
    ST-A/PI     01M_ECC600     1          -     Application Servicetools for ECC 600
    Would really appreciate it if anyone can help...

    Hello Ling Lu,
    this error points out to a corrupted MEMSAPehpi.dat file, probably when you terminated the session via Ctrl+C.
    You must comment out the last line(s) of this file in order to proceed. Please open it and look for a repeated or incomplete last line(s) and comment it out. Make a backup of the file first, then repeat the phase, it should work.
    Best regards,
    Tomas Black

  • Error While system Componenet Upgradation

    Dear all,
    We are using SOLMAN 4.0 and Charm Functionality.We are trying to configure the maintenance optimizer,for which minimum system requirement was given in the note:990534 .
    So we are trying to upgrade the system componenet ST-SER 700_2005_2 to 700_2006_1.(which is one of the requirements.
    When we are doing this we encounter the following error.
    "Function DSWP_BPM_OTHER_CUST_GET (DSWP_BPMO|13) does not fit into the existing function group ((DSWP_BPM_SOLR|01))"
    Have anyone encountered the same error?
    Please support to close the issue.
    Thanks and regards,
    Avinash.

    Hello Avinash,
    This problem has been reported to SAP.
    Please delete the function module DSWP_BPM_OTHER_CUST_GET via TC SE37.
    It will be delievered by the delta-upgrade again. After, you can go on
    to apply the queue.
    Regards,
    Joe

  • No upgrade package found for component SAP_BASIS

    Hello,
    I'm just upgrading from NW 7.01 to NW 7.4. During the EHP_INCLUSION phase I'm getting this error:
    The program has not found a matching SAINT package for 'SAP_BASIS'.
    "Last error code set: Enhancement Package inclusion failed, no upgrade package found for component 'SAP_BASIS' "
    I've checked the name of patches on stack.xml and upgrade directory, and patches are in the upgrade directory.
    Any suggestion?
    Thanks.

    Hi Ruben,
    From the error message
    "Last error code set: Enhancement Package inclusion failed, no upgrade package found for component 'SAP_BASIS' "
    You need to include delta upgrade package for SAP_BASIS component in the /EPS/in queue.
    File name should be similar to "K-740BHINSAPBASIS.SAR". Please check whether such package has been downloaded ,extracted and include into the queue.
    Hope this helps.
    Regards,
    Deepak Kori

  • Networking issues following upgrade to 10.5.8 when iMac wakes from sleep

    Hello,
    I recently upgraded to 10.5.8 and I'm now experiencing issues with network connectivity following the iMac waking from sleep. I have to stop Airport and then start it again to resolve the issue.
    Can you provide any resolutions to this or advice?
    Many Thanks,
    Sam

    Reinstall the Mac OS X 10.5.8 Combo Update because the Combo seems to help a lot of people when a Delta upgrade doesn't take right.

  • DVD drive failed after upgrade to 10.4.9

    After upgrading to OS X 10.4.9 I noticed that my internal DVD drive (SuperDrive Pioneer DVR-104) failed.
    I did the delta upgrade and immediately checked the most common "error" of misbehaving eject key. The key did not function at all, even after pressing it for minutes.
    Later I found out that the complete drive failed.
    System Profiler tells me (sorry german output)
    Modell: PIONEER DVD-RW DVR-104
    Version: 0000
    Seriennummer:
    Absteckbares Laufwerk: Nein
    Protokoll: ATAPI
    Einheiten-Nummer: 0
    Socket-Typ: Intern
    Note: no version or serial number!
    DVD player gives the message (translated):
    "no valid DVD drive found [-70012]"
    Toast does not find the drive.
    I did:
    - repair permissions
    - repair drive/file system
    - the combo upgrade
    - reset parameter ram
    - reset all from open firmware
    - reset PMU
    no change
    Do you have any hints besides replacing the drive?
    Maybe it's just a coincidence. I did not use the drive for 2 weeks before
    the upgrade.
    Stefan
    PowerMac G4 Dual 1GHz MDD   Mac OS X (10.4.9)  

    Hi, Welcome to Apple Discussions.
    It sounds like LaunchServices.
    Launch /Utilities/Terminal and copy & paste this at the command line:
    Code:
    <pre class="alt2" style="margin:0px; padding:3px; border:1px inset; width:640px; height:34px; overflow:auto">/System/Library/Frameworks/ApplicationServices.framework/\Frameworks/LaunchServi ces.framework/Support/lsregister \-kill -r -domain local -domain system -domain user</pre>
    Then log out and back in or restart. Let us know.
    -mj
    [email protected]

  • Xcode 3.0 - 3.1 or 3.1.1 upgrade

    Hello
    I'm currently running OS X 10.5.5 I recently installed Xcode from the Leopard DVD, which is Xcode 3.0 as I understand. From the ADC downloads it appears that there is no patch/delta upgrade and one has to download the entire (~1GB) developer DVD and use the upgrade option. Is there no way to just upgrade what's needed?

    Brandon, thanks for your reply. I'm in the same position as spiderpig.
    It would be great if Apple could implement updates for Xcode. Instead I'm going to lose 3hrs waiting for Xcode to download.

  • OrgChart Upgrade from 3.0 to 4.1

    Hi Experts,
    We are planning to upgrade our old Nakisa OrgChart 3.0 application to latest OC app 4.1.
    I downloaded the package from service market place and found that 3 types of folder:
    1. Delta upgrade
    2. Fresh Installation
    3. Upgrade
    Current ECC version is 6.0 EHP5. Can I install "fresh installation" add-ons? or I have to apply upgrade add ons?
    Thanks,

    Basis admin...
    I think you should be able to do a fresh install, but that is quite a big jump and there were some issues around 4.0 SP1 upgrades.  In all honesty, your safest course of action would be to raise a message on OSS and have Nakisa to confirm the upgrade sequence (hopefully just a one step fresh install) between 3.0 and 4.0 SP1.  It would also be useful to share any recommendation/success/failure on this thread in case anyone else is considering the same upgrade now or in the future.
    Regards,
    Stephen.

Maybe you are looking for

  • How to create a container element?

    Hi, Could somebody please tell me how to create a container element and how to create a multi container element? How is this element used in the fork step? I am using a fork with 3 branches but the agent assignment is a problem.The workitem does not

  • After IOS 5 upgrading Iphone we set up wireless network each time (WPA2 Enterprise)

    Our company is connecting to wpa2 enterprise. when we used IOS 4.XX we could connect wpa2 enterprise but after upgrading IOS 5.0, it occured some problem. Our staff should change a password per 3 month, at that time we should delete a network but SSI

  • Upgrade Service pack

    Hi. We currently use NW 6.5 SP6 We have been advised to upgrade to SP8 We use the following products (IDM 3.0.1, Zenworks 7, Edirectory 8.7.3) Has anyone recently upgraded to Sp7 or Sp8 and encountered issues especially around the versions of IDM etc

  • Authorization profile S_RS_RREPU

    Hello Guys i need to add this profile in my user S_RS_RREPU  (this is for BW authorization to display query) but i can not see this profile does't exist on my BW system . Do you have any idea? maybe i need to activate or create?? where i can find it

  • Enable user to add an extra text field

    I am creating teacher unit curriculum building plans, where many lessons make up a unit.  Some teachers may have 5 lessons in unit, while other teachers may have 10 lessons in a unit.  How can I have a form for a unit with 5 lesson templates to fill