Despatch serial number Interval not found Number object J_1IINTPR2

Hi all,
I am facing one error when creating excise invoice.
system shows the following error.
Error in allocating Despatch serial number Interval not found Number object J_1IINTPR2
For this, i tried to maintain number range in j1i9 object J_1IINTPR2.
Here system is not showing excise group number.
But for one company code it shows and another company code excise group code is not displayed.
Can anyone tell me what will be the problem?
Thanks in advance,
Babs

Thanks for your reply..........
excise group 10 belongs to first plant
excise group 20 belongs to second plant.
settings are maintained same for the two excise group.
excise group 10 is displayed in  J1I9 (Number object J_1IINTPR2).
But excise group 20 is not displayed over there. I want to maintain number range for excise group 20.
Thanks in advance
Babs

Similar Messages

  • Number range interval not found for object ISH_NLEI in executing NP38

    Dear ALL,
    In executing Transaction NP38 when we save the surgical procedure codes the system
    generates an error message "number range interval not found " . The object referred here
    ISH_NLEI number range has already been defined in spro Define technical number range.
    Please assist what should be done here to resolve the problem.
    Regards
    Ramit

    Hi, check if it maintained in tcode snro for this object

  • Error in allocating Excise inv no Interval not found No object J_1IEXCLOC

    Hi, When I try to execute J1IV, I am getting the below error:
    Error in allocating Excise invoice number Interval not found Number object J_1IEXCLOC
    Message no. 8I336
    All number ranges are maintained for the above object. Please let me know, whether anyone encountered the same situation and how to resolve the same.
    Regards
    Suresh

    Hi,
    Please check in SNRO as you allocated no range for J_1IEXCLOC  object for your series group & check for J_1IARE3 object also for same series group.
    regards

  • Error in allocating Despatch serial number Interval not found Number object

    Hi All,
    While saving the Excise Invoice(created w.r.to Invoice) in J1IIN system is throwing the error:
    "Error in allocating Despatch serial number Interval not found Number object J_1IINTPR2
    Message no. 8I336"
    The Excise Group(say 99) was created.
    But the same is not reflecting in the drop down list of SNUM for maintaining the No.Range in the Object  J_1IINTPR2.
    Do the needful to resolve this issue.
    Needless to say helpful answers will be rewarded.
    Regards,
    Raj Kumar Reddy.

    Dear Raj,
    Go to Excise group details here you check these settings
    IMG>Logistics general>Tax on Goods movements>India>Basic settings-->Maintain Excise groups
    Have you check all these check boxes
    1.Excise Inv during billing
    2.Create and Post Invsingle step                    
    3,Depot Excise invoice
    4.EI capture
    5.Diuty Different at GR
    6.EI create/RG23D selection
    7.Update RG1 at MIGO
    I hope this will help you,
    Regards,
    Murali.

  • Error in allocating Despatch number Interval not found Number object J_1IIN

    Dear All,
    I am facing a problem while doing an excise invoice. System is throwing an error saying that " Error in allocating Despatch number Interval not found Number object J_1IINTPR2.
    Can somebody help me with a solution ?
    Rgds,
    Indrajit Dey

    Dear Indrajit
    Go to SNUM, input object J_1IINTPR2 and click on Number Ranges.  Enter [Excise Group]  and click on Intervals (with pencil icon).  Maintain the number range and save.  Now try the process once again.
    thanks
    G. Lakshmipathi

  • Error in allocating RG23D document number Interval not found Number object

    Dear
    Expert
    Error in allocating RG23D document number Interval not found Number object J_1IRG23D
    I tried the solution given in the forum but its not working,
    Pls help me out.
    Thanks and Regards
    Deepankar

    Hi,
    As a know that this is a problem of number range and I mentioned the same(SNUM> given the object and maintain the number range of this fiscal year but it didnt work also searched in the forum but didnt got any other solution so posted the issue.
    hope now its clear.
    Thanks and regards
    Deepankar

  • Number range object HRTR_PDOC : Interval not found

    Hi,
    I am doing Travel Mgt testing i got two problems
    1. Travel Policy is not taking when entering the expences
    2. when posting the doc to FI the error "Number range object HRTR_PDOC : Interval not found" is coming
    Pls suggest
    thanks in advance
    chandu

    Hi,
    Check table NRIV
    Regards,
    Manoj.

  • Interval not found number object J_1IINTNUM.

    <b>Dear friends,
    During creation of excise invoice(t code J1IIN) i found
    Error in allocating int. doc number
    Interval not found number object J_1IINTNUM.
    PLEASE HELP
    Ranjan</b>

    Dear Ranjan,
    Go to transaction SNRO enter J_1IINTNUM -> click on Number ranges pushbutton option in the applicaiton toolbar -> Click on Change Interval pushbutton -> Maintain Number Range Interval and save.
    Regards,
    Naveen.

  • Funds mngt - Number range 01 not found for object BULI_DOCNR

    Hi all
    need some urgent help to crack an error am getting while creating a budget in funds management.
    the error am getting is
    "Number range 01 not found for object BULI_DOCNR in fiscal year 2007"
    I have maintained the number range in
    Public Sector Management-Budgetary control system-Budgeting-Budget Entry Documents-Maintain Number Range Interval for Entry Documents.
    But am still getting the error....
    will really appreciate some help on this
    thanks in advance

    The number range object refers to  "FM budgeting line item number "
    Are you using Former budgeting or BCS ?
    Try t-code- ok11 and ok91 under former budgeting.
    Thanks
    Siva

  • Error in allocating Despatch serial number

    Hi friends ,
    I am trying to save a commercial invoice and the setting allows to print the exicse invoice immediately. But on pressing the save button in VF01, update gets terminated.
    error : Error in allocating Despatch serial number Interval not found Number object J_1IINTPR2
    Message no. 8I 336
    Can anyone advise?
    Thks/Vinod
    messenger id
    [email protected]

    Hi Vinod,
    Please check whether the number range is maintained for the object or the number range might have exhausted
    Hope this helps.
    Sridhar

  • Error CREDIT_SEGMENTS_ADD COIOB NOT FOUND FOR object CC...

    Hi All,
    My user is geting the ERROR while running the actual OH calculation through CJ45 as below:
    Error CREDIT_SEGMENTS_ADD COIOB NOT FOUND FOR object
    Message NO k5011.
    As this is more ralaing to the costing sheet, this refers to controlling module.
    We have verfied the Note 515426, but the correction were delivered in 4.7 itself. My client is using the  6.0 verion.
    Can anybody suggest the reason for the above error.
    Thanks & Regards
    Shankar

    HI,
    whats the message class, message number?
    BR Christian

  • Director Player Error : Handler not found in object

    Hi,
    I have made an exe to run a video in Director. This was done using old version of director, 8.5 supposedly.
    When i try to run video through this exe, the video plays in background but i get the following error(snapshot attached):
    "Handler not found in object
    # openport
    Script Error. Continue?"
    I have installed shockwave player 8.5 and also put all the files from xtra folder to the folder where exe in lying but still i am getting the same error.
    Any help will be greatly appreciated.

    Looks like something in one of the scripts in your project that is being called but is not working correctly for some reason.
    Without seeing the code it's hard to tell what the problem may be. I'm wondering if there's one of the old-style line continuation characters that may be breaking the #openport handler somewhere in your scripts.

  • Entry not found in object buffer error in leasing quotation

    i am getting following error in SAP CRM 7.0 in quotation level.
    when i am entering financing product in quotation.
    Item 200     Entry not found in object buffer     @5F\QNo long text exists@          Dates     Administrator
    Item 200     Entry not found in object buffer     @5F\QNo long text exists@               Administrator

    thank for your reply
    At least we found out message class of this message.
    From your given Function module we could identify that it giving information  message, but we are experiencing error of object buffer related message.
    In error it showing sub object as "Dates", can you please guide us to elaborate this further.
    Regards,
    Vikil

  • Entry not found in object buffer

    Hi,
    When we create service desk message we are getting Entry not found in object buffer error error. Can you please help me out to resolve this issue.
    Thanks

    Hello again,
    Is it a customized support message (e.g. ZLFN for instance) or the standard one ? If customer message, check your action profile... You need to have a copy from the standard action SLFN0001_ADVANCED_UPDATE_DNO.
    Hope it helps.
    BR.
    Stéphane.

  • [Athlon64] Serial ATA Drive Not found Error on bootup ATI Radeon RS480M2-IL

    MSI "RS480M2-IL" ATI Radeon XPRESS 200 Chipset Motherboard For AMD Socket 939
    I have just built an Athlon 64 system using the motherboard stated above. When I boot the system up, I get an error message stating that the system can not boot up from the CD 95% of the time.  I then use Ctrl-Alt-Del and the system boots up just fine.  I have the BIOS set to search the hard disk first for boot up before looking at the CDROM and I still get this error. I believe it can not find the hard drive due to timing or what???
    We did load the MS XP 64 bit operating system at first, but we found that there were ot enough drivers available. We then did a quick format and loaded the the MS XP Pro operating system after that.  Everything works fine except for this error message we get 95% of the time on bootup. We are using a serial ATA 80 GB Western Digital Hard drive and a Lite-On dual layer DVD burner(IDE).
    Power supply is a Macron
    +5v=30A
    +12v=15A
    -5v=.5A
    -12v=.8A
    +3.3v=14A
    +5vSB=3A

    Hi,
    until I was using BIOS 3.2, the system works very fine. After upgrading to BIOS 3.3, my system usually did not boot after cold restart (button) but then after warm restart (ctrl-alt-del) always started. It was not usable because I use scheduled starting of PC to record TV programs. Every cold restart SATA boot drive boot was not found but after warm restart everything OK. So I reflashed back bios 3.2 and the system works perfectly again.
    Any one similar experience?
    p.s. With 3.2 BIOS I am very satisfied with this motherboard and its stability. But not sure about future upgrading BIOS :-(