Hello All,
I have a requirement to create an DELVRY03 Idoc when doing PGI of a outbound delivery.
We have an output type created for this and assigned in message control in partner profiels. When I am assigning this output type manually in VL02N and upon saving the Idoc is generated but I would like to restrict this only for PGI.
Please let me know the solution and apreciate your quick response.
Regards,
Venkat

Hi,
In the output control settings (NACE), assign the Output control routine '1' against the output type.
Edited :
NACE -> Select Application V2 -> Click on Procedures Button -> Select the output procedure used -> Click on Control option -> Assign requirement '1' (Delivery GI Posted) against the Output type.
Regards
Vinod
Edited by: Vinod Kumar on Jun 24, 2010 5:10 PM

Similar Messages

  • PGI not happening after creation of shipment

    Hi Gurus,
    I created shipment document after the creation of delivery but my concern is PGI is not happening automatically I need to go for T-code VL02N to do the PGI manually.
    So can anyone help me out in this regard how can the PGI triggered automatically as soon as the shipment document is created.
    Points rewarded.
    Cheers,
    Krishna

    Hi,
    THis can be get it throught activity profiles.
    Note 740989 will help you  about how to handle report RV56ABST.
    I hope it helps.
    David

  • Authorzation only to Insert / not to change in P_PERNR

    Hi,
    I have to give the Authoirzation for Employees (ESS/ECC6) to Insert new
    Temporary Address (IT0006 /subtype 2).
    I am using the object P_PERNR. When i give "W" authorization
    it allows both Insert & Change.
    How to give only for Insert and block Edit of the Address.
    Regards,
    Boobalan

    Hi,
    There is no way doing that but however you can go for Double Verification Principle (using S,E,D) values to do that.
    This might help in this regard,
    The double verification principle requires that at least two persons are involved in changing HR infotype data. This principle can be used for all infotypes except 0000 (Events), 0001 (Organizational Assignment), 0002 (Personal Data), 0003 (Payroll Status) and 0031 (Reference Personnel Number).
    The double verification principle is implemented by setting a lock indicator. If an infotype record is locked, this record is (physically) available on the database but is not taken into account in HR evaluations. (For example, if a "recurring payment/deduction" record is locked, it is not selected in HR payroll and is therefore not handled like an existing record). The lock indicator limits the validity period of records. Only records without a lock indicator are "valid" records. When the double verification principle is applied, one user stores locked data and another deactivates the lock indicator (unlocks the record). There are two ways in which two users can write a "valid" record to the database.
    Asymmetric variant
    User A is authorized to edit locked records (he/she is assigned authorization level 'E' (edit) and 'R' (read locked or unlocked) records. User A is authorized to:
    create or copy locked records. Records created (or copied) by user A are locked. Locked or unlocked records can both be used as models.
    change locked records,
    delete locked records,
    read locked or unlocked records.
    User B is authorized to:
    set (lock) or remove (unlock) the lock indicator (authorization level D),
    read infotype records (authorization level R).
    B checks the data created or changed by A and declares this data valid by unlocking it. Once the data has been unlocked, user A can no longer change it. To do so, user B must first lock the data so that user A can change it. User B must then check and unlock it, etc.
    Please note the following: User A can copy existing (and unlocked) records. This copy is initially locked. If user B unlocks this copy, the unlocked model would be deleted either completely or partially if the time constraint is 1 or 2.
    Example: You want to apply the double verification principle when entering a recurring payment (wage type nnnn [time constraint 2] in infotype 0014). User A (authorization level E) creates a record with subtype nnnn and enters a certain amount. The system sets a lock indicator for the record. This record is not taken into account in evaluations (payroll) while it is locked. Only when it is unlocked by user B does the entry of user A become active. An incorrect amount can be changed in two different ways:
    1. B locks the record, A changes it, B checks and unlocks it, or
    2. A copies the existing record and corrects the amount (in the copy); B checks the copy and unlocks it. Since the time constraint is '2', the existing unlocked record (with the incorrect amount) is deleted. The copy with the corrected amount then becomes valid.
    Symmetric variant
    User A and B have identical authorizations. Both have a read authorization and an authorization which allows them to edit locked records and unlock these (authorization level S). User A and B are both authorized to:
    create (or copy) records. These records are locked (both locked or unlocked records can be used as a model),
    change records (records which have been changed are locked even if they were previously unlocked),
    lock records,
    unlock records if the last person to change the record is not identical with the current user.
    Here, user A and B check each other's work. When A creates or changes a record, it is locked. B checks the record and unlocks it (A can also perform B's work and vice versa). It takes two users (with identical authorizations) to create or change a valid (unlocked) record. Users with authorization level S cannot delete records.
    Example: You want to apply the double verification principle (symmetric variant) when entering a recurring payment/deduction. User A enters the data. The record is locked. User B unlocks it. If data needs to be changed after the record has been unlocked, both A or B can do this. The data is changed and the record locked. The other user can now unlock this record. Alternatively, A or B could create a 'locked' copy. In this case, the model remains an unlocked record. If the copy is unlocked, the copy overwrites the model (time constraint 2).
    The following applies to the symmetric variant of the double verification principle.
    The person who last changed an infotype record must not have changed it explicitly: Even if the validity period of a particular record changes when user A creates or deletes a different record (due to time constraint 1 or 2), A is nonetheless entered as the person who changed the record. For example, both A and B have an 'S' authorization. A changes an existing infotype record (time constraint 2) with a validity period from 01/01/96 - 12/31/99. Then B creates the same type of record for 07/01/96 - 12/31/99. The result is two locked records with validity periods from 01/01/96 - 06/30/96 (1) and 07/01/96 - 12/31/99 (2); in both cases, B is entered as the last person who changed the record. However, B did not explicitly change the first record; he/she merely delimited it by creating the second record. As a result, A can unlock the first record.
    Hope this helps
    Manohar

  • Serial Numbers are not downloading after creation of Delivery in ECC

    Dear all,
    As per client business process, we need to download Serial numbers after creation of Outbound delivery.
    I could see the generated Serial numbers in ECC Delivery document, but those Serial numbers are not downloading into CRM.
    I have already done initial download for SERIALNUMBER object and I could see downloaded serial numbers in COM_TA_R3_ID Table.
    But after creation of Outbound delivery in ECC, those delivered serialnumbers are not available in CRM system, even after successful data transfer of Sales Order, Delivery, PGI and Invoice documents Information.
    Kindly help me in resolving the above issue
    Best regards
    Raghu ram

    Hi
    1.Check in material master whether serial number management is active in Plant data/stor Tab and serial number profile is assigned
    2. Check while doing MIGO once if u enter the material and transfer qty you are getting the serial number tab or not
    3. If everything is ok, then after posting the document check the serial number status in IQ09, check the stock type and the storgae location in the serdata tab
    Regards
    Amuthan M

  • Sales order status to show as Complete only after PGI

    Hello
    I have one requirement. Now currently in sales order status of the order is showing complete once the item being delivered.
    But our requirement is that, the status of the order should be shown complete only when PGI is done not after delivery.
    I would like to know if any exit or any other program will help us in finding this solution
    Thanks in advance
    Naveen

    Dear Naveen,
    Sales order status depend on Item Category completion rule, please check on VOV7 for your sales order item category. In standard SAP, below rule can we define with item category:
    Not relevant for completion
    A
    Item is completed with the first reference
    B
    Item is completed after full quantity has been referenced
    C
    Item is completed after the target qty is fully referenced
    D
    Item is referenced via contract release
    E
    Item is completed after full target value is referenced
    Hope it will helpful for you.
    Regards,
    Shatrughan Singh

  • Sales order related invoice but invoice can generate only once PGI is done.

    Hi All,
    I have situation in project, we have to generate sales order related invoice. but Invoice should only get generate once delivery, Shipment and PGI is done.
    My Qus are listed below?
    1. Is that possible in Standard SAP?
    2. Is it possible by using any user exit?
    we don't want to do any Z thing in our project, so please suggest how we should handle this situation.
    Thanks & Regards,
    Sulabh

    Hi Prasanna,
    My client is a luxury car maker in UK and its complete make to order scenario.
    I have doubt
    1, Suppose Customer is ordered 100 PC , Suppose end user Trying to Raise the Billing based on the Order but system should check Delivery means PGI is done Or not , in that case supose Delivery is Done 50 PCS But at the time of Billing how you Come to know that Delivery is Happened 50 PC then again you back and See the Document flow of the Sale order
    *I my case there will always be one material with 1 quantity. so no issue of partial delivery*
    2. Same customer is ordered Multiple SO , at the time of Delivery You combined Multiple Sale Orders and Done the Partially Delivery and How come to know each SO Partially Qty that means Again you have to check
    There will not be a case of combined delivery also.
    3. IF Partially Done in Delivery level for Multiple SO , how can you raise the Partially Qty of those SO for Billing
    Thanks & Regards,
    Sulabh

  • PGI not to create without proforma

    HI
    We have req where we want system to stop PGI if invoice or proforma not created? what's the copy rotuine can be used?
    Reg
    Shan1242

    Dear Shan
    Sorry I am little bit confused over the requirement.  As you would be aware only after PGI, we would be generating Proforma or invoice.  This being the case, how you would like to control.
    thanks
    G. Lakshmipathi

  • The problem I have since I upgraded to Mavericks version 10.9.1 The problem appears only with Mail not with other programs, not even with my browser. When I try to zoom the text of an e-mail I received or sent , I can no longer use the keys Command   to e

    the problem I have since I upgraded to Mavericks version 10.9.1
    The problem appears only with Mail not with other programs, not even with my browser.
    When I try to zoom the text of an e-mail I received or sent , I can no longer use the keys Command + to enlarge the text, although I can reduce it with Command -.
    As I have a problem with my eyes, This is a serious matter for me.
    When I write an e-mail, if I select text and press Command +, it just displaces the text to the right.
    Now, my husband has a USB keyboard. If he connects it to my computer, his regular Command + does not work either, but  he uses the extended keyboard, then it works. Unfortunately, he needs it for a musical application which does not work with a wireless keyboard.

    Firefox 3.6.4 and 3.6.6 use a process called, "plugin-container.exe" which was using up most of my CPU when I opened up multiple tabs that contained Adobe Flash files, and caused Firefox to lock up.
    My solution was to use Firefox 3.5.10 which you can get from the Mozilla website at [http://www.mozilla.com/en-US/firefox/all-older.html]
    I am using Adobe Flash 10.1.53.64 without any problem in this version of Firefox. Check the release notes, I believe it contains all the latest security fixes in "Firefox 3.6.4".
    Hopefully, they will fix Firefox 3.6 in the next version (e.g. Firefox 3.6.7), until then you should probably use "Firefox 3.5.10".

  • Adobe Cloud - Only Dreamweaver does not launch

    I just subscribed for the trial version of Adobe Cloud and installed DW, PS and AI. All works well only DW does not start up. The icon appears and bounces a few times and then disappears without opening.
    Any idea how to solve this? On a Mac.
    Thanks!

    I uninstalled everything again... But now I can't even install the Adobe Application Manager. I get an error: Download error.
    Can you please let me know what info you need? I had CS4 installed before... Maybe the old files are not all deleted? I used the Adobe Creative Suite Cleaner Tool. But I think some programs are not correctly uninstalled.

  • Remote for only Macbook but not dock

    hello everbody,
    is there any way that use the remote control only MacBook but not ipod dock? because when i push the play button, i got my ipod and macbook react in the same time.
    thanks for your help.

    If you have two remotes you can pair one to work with the macbook and one to work with the ipod.
    You can find instructions on how to pair a remote with a mac here: http://support.apple.com/kb/HT1619
    and instructions to pair with an ipod here:
    http://support.apple.com/kb/TA23708
    hope this helps!

  • I want to transfer my music from one computer to another, however a large majority of my songs are already on the new computer, is there a way to transfer only the ones not there? or to see what songs are only on the one computer

    i want to transfer my music from one computer to another, however a large majority of my songs are already on the new computer, is there a way to transfer only the ones not there? or to see what songs are only on the one computer

    Welcome to the Apple Community.
    Homesharing gives you the option of seeing only the content in the shared library, that is not already in your own library.

  • How do I get iphoto to import videos from my iphone 3s? It only imports photos, not videos. My iPhoto is v. 4.0.3.

    How do I get iphoto to import videos from my iphone 3s? It only imports photos, not videos. My iPhoto is v. 4.0.3.

    My iPhoto is v. 4.0.3.
    Is your QuickTime up to date?
    Video importing requires QuickTime 7.6.2 or later.
    http://support.apple.com/kb/HT4083

  • This was only 1 page, not a large amt of printing?

    This was only 1 page, not a large amount of printing?

    Your post makes no sense the way it is written, please take some time to recompose and ask a question. Please remember we are end users just like you and cannot read minds or see what you're doing so you need to write clearly and draw an accurate picture of what is occuring.

  • HT3669 HP ENVY 4500 e-All-in-One Version 3.2.1 does not work on iMac 20-inch, Mid 2007. Only recognizes scanner not USB printer.

    HP ENVY 4500 e-All-in-One Version 3.2.1 does not work on iMac 20-inch, Mid 2007. Only recognizes scanner not USB printer.
    I would like to print via the USB connection instead of wireless (the wireless does work, and the scanner works via USB).
    I tried connecting the printer directly (via USB) to my MacBook Pro laptop and it worked just fine.
    How can I make this printer work on my iMac?
    I spent 4 hours on the phone with HP and we did every combination of installation of drivers ad nausum and their bottom line is that it is a Mac problem.
    Any help would be appreciated. Will be sending this printer back to Amazon if I can't make it work on the USB.
    I am open to questions or suggestions
    Thanks,
    Chet

    After 4 hours on the phone with HP and another hour with Apple (Mavericks support) no real solution other than check everything (removed everything from Login Items, removed all HP software anywhere in the system reboot, reinstall printer) then when nothing worked for the 4500, did an OS Reinstall (boot with CMD+R).
    The Mavericks support group did open an incident (# 542875311) and I will update it when I figure out how to find it on the system.
    My feel is that the base problem is that somewhere between the HP-Inkjet-SW-OSX-Mavericks_v12.34.49-2 package and the Apple HP Printer software in the Library (version 2.16.1) the app for printing via the USP Port just does not get installed for the mid 2007 20 inch iMac. The scanner is recognized on the USB Port and the Printer works fine on Wi-Fi. I have too many devices to burden my home network with anothe device. Also, every time I put any HP Printer on Wi-Fi, my router (Netgear N600 WNDR3400 running 12 to 20 devices depending on who is home) gets wonky (but that's anothe story...).
    Additionally, when I attach the HP Envy 4500 to my MacBook Pro (2010) it works perfect - print and scan via the USB prot and both functions show in the System Preferences - Printers and Scanners just as expected and just as the 3050 does.
    Chet

  • Hi all not sure where original request went but as a new apple user I have external hard drives that are now "read only" and I can't change or save documents.  Went to Get Info and this did not help.  Can anyone assist with solution, thanks.

    I am a new user to apple and have external hard drives from previous computers.  I have many documents I can no longer access and change as they say the drives are read only.  How do I change the read only to read and write etc for these external drives.  I tried Get Info but this did not assist.  Thanks.

    Hi,
    Google is your Friend
    10:18 PM      Sunday; February 12, 2012
      iMac 2.5Ghz 5i 2011 (Lion 10.7.3)
     G4/1GhzDual MDD (Leopard 10.5.8)
     MacBookPro 2Gb (Snow Leopard 10.6.8)
     Mac OS X (10.6.8),
    "Limit the Logs to the Bits above Binary Images."  No, Seriously