Digits in Unit of Measure "%"

Hi all,
for one position we use "%" as unit of measure. In our developing-system I am able to enter a decimal number WITH comma. In our productive system that´s not possible.
Does anyone know where to change that behaviour, i.e. if commas are allowed in a unit of measure?
many thanks & best regards,
Thomas Kejik (Vienna)

Thomas,
Such a message is received when the format of entered figure is not correct.
You'd better, first, look at the format of your % UoM (CUNI t-code): number of decimals (if any) and digits total.
It's very important because the definition of your UoM might be different in Dev & Prod. Especially if import of global settings (that includes UoMs) is done from underlying R/3 systems.
Then try to enter the number with appropriate decimal delimiters, triades delimiters, number of decimals etc.
Hope you'll be lucky!
Edited by: Eugene Khusainov on Mar 11, 2008 9:03 PM

Similar Messages

  • Unit of Measurement in Material Master

    Hello Experts...
    I have an intresting issue on Unit of Measurement. I would like to maintain alternative unit of measurement as per below..
    1 EA = 1 EA
    1 ROLL = 5000 EA
    1 CT = 150,000 EA
    However the field UMREZ length in the material master allows me to enter upto 5 digits...and also it is not possible to enter decimal digits here.
    Have any one of you faced this kind of issue, if any one faced what would be the solution for this...?
    Look forward to hearing from you..
    Cheers
    Umakanth..

    Hi Umakanth,
    For increasing the numerator for conversion of base unit of measure, UMREZ  would be  appending the structure SMEINH by requesting Access Key from SAP.
    Even though its not a suggestible decision to append standard SAP structure , if the requirement demands we may need to do that.
    Cheers!
    Sudhakar Reddy

  • Conversion Problem in Unit of measure 1PAC=100,000 EA

    Hi Experts,
    I am facing the problem in conversion of Unit of Measures.
    If some material has the conversion unit when we order to Vendor.
    The Unit of measure is EA, the Order unit is PAC.
    The conversion is 1PAC=100,000 EA
    But the System is allowing as 1PAC=10,000 EA only and it is not allowing to enter 100,000 EA and throughing the error
    Entry too long (enter in the format __,___)
    Message no. 00089
    How can we increase the characters of the Unit of measure. Like this we have some 50 Materials, I need to increase the length of the conversion spaces. How to do it, Please guide me.
    rgds
    Swamy

    Hi
    you can check this out the denominator factor is Stored in structure - SMEINH - field UMREN.
    Best option is to maintain decimal place for the UOM , which is more easier to mainatin.
    Even if you go through the note the same is explained. Please read below for Too large numerators and denominators
    When 120000 CM3 = 0,2 tons (TO), you can no longer save numerator and denominator of conversion ratio 600000 CM3 = 1 TO as numerator and denominator may have maximally five digits.
    Here, you must either select a larger volume unit or a smaller unit of weight: With DM3 the conversion ratio would be 600 DM3 = 1 TO, with KG the conversion ratio would be 600 CM3 = 1 KG.
    Generally, the alternative units of measure and the base unit of measure should result in quantities that are in the same dimension since the conversion factors may not be larger than 99999/1 and not smaller than 1/99999.
    Thanks & Regards
    KK
    Edited by: Kishore Kumar Chiluka on Apr 22, 2008 8:25 AM

  • Numerator in Unit of Measure not big enough

    Hi,
    The numerator, field UMREZ, of the unit of measure has a maximun lenght of 5 digits ( maximum of  99999 ). But for certain conversion I need (in MM02-> aditional data->tab units of measure):
    120000 EA = 1 ROL
    How can I do this without entering something bigger than 99999?
    I have thought in three alternatives:
    1.- Modification of that data domain, so that it can be stored up to 999999.
    2.- Use decimals in the denominator , so that I have something like 12000 EA = 0,1 ROL.
    3.- With an auxiliar unit of measure EA2 ( created via CUNI, linked to EA): 10 EA2 = 1 EA :::::and then::::: 120000 EA2 = 1 ROL.
    I havent been able to complete the 2nd and the 3rd. ANd I want to avoid the first...
    Do you know if something like this can be done? if so, how????
    I have found post UOM conversion not big enough but I could not find any usefull answer in there ...
    Many thanks in advance.
    Aaron

    Hi,
    Yes, I had already read this note, thanks for the info anyways.
    They describe exactly my case:
    Example 3: Too large numerators and denominators
                           When 120000 CM3 = 0,2 tons (TO), you can no longer save numerator and denominator of conversion ratio 600000 CM3 = 1 TO as numerator and denominator may have maximally five digits.
                           Here, you must either select a larger volume unit or a smaller unit of weight: With DM3 the conversion ratio would be 600 DM3 = 1 TO, with KG the conversion ratio would be 600 CM3 = 1 KG.
                           Generally, the alternative units of measure and the base unit of measure should result in quantities that are in the same dimension since the conversion factors may not be larger than 99999/1 and not smaller than 1/99999.
    But I can not change the Basic Unit of Measure, because the Material has already movements, and I dont know how to create another unit of measure (let say EA2) linked to EA with a the value 1 EA2 = 10 EA. In this case I could use EA2 in the material with the conversion 12000 EA2 = 1 ROLL.
    Is this possible? How can I create this unit? in CUNI I can create a new UOM but I dont see how to link it with an existing one ( create a conversion between them ) .
    Thanks!!

  • Decimal Points for Unit of Measurement

    Hi all
    For doing service entry in the QTY field can we put the value upto six decimal for any unit.
    in customisation for Unit of measurement can we configure this thing putting decimal places - six or is there any other setting is required
    Please help
    Thanks in advance
    Rajesh

    Hi,
    Yes in customisation for Unit of measurement you can customize it,
    but it will be valid whenver you use this UOM in the system.
    There is one thing also you can do
    The Quantity fields decimal points in service entry is by default 3 digits ,
    so to use 1,123456  quantity for lets say price 10 $
    you can multiply both sides with 1000
    i mean
    use 1123,456 for 10000 $
    just an idea
    Regards
    Hope it helps

  • New Unit of measures & ISO codes

    Hello,
    We are currently trying to create some new unit of measure in our system which will be used in QM module and are very specific. For this reason, we can't find any corresponding ISO code in our SAP system. SO we have a few question about this point :
    1) Could you tell us which UoM is ISO or not among the above list ? For ISO UoM, could you give us the corresponding 3 digits code (field T006I- ISOCODE) we will need to use to create them into our system?
    o   AE :                                       Amylogram Equivalent
    o   °BX :                                     Brix Degree
    o   Cfu/m3:                              Colony Forming Unit per m3
    o   IU/kg :                                 International Unit per Kilogram
    o   meq/kg :                            Milli Equivalent per Kilogram (WHO-TEQ)
    o   µg/100g :                            Microgram per 100 grams
    o   mL/100g :                           Milliliter per 100 grams
    o   pg WHO-TEQ/g :             Picogram per Gram
    o   g/mL :                                  Gram per Milliliter
    2) Is it possible to add some new ISO codes in this SAP standard table (T006C)? On your side, do you update the content of this standard table (update of the content of the standard table) and dispatch it to your customer?
    3) Do you have a website or SAP transaction referencing the entire official ISO codes you've registered?
    In this website link(http://wiki.sdn.sap.com/wiki/display/SI/UnitofMeasurerelatedsettingsinSAP), you are redirecting us to an ISO reference website in part I.2.(http://www.unece.org/etrades/codesindex.htm ) which is not working anymore
    Thanks in advance for your help.
    Best regards,
    Pierre Alauzet

    Hi
    you can create new  UOM  but you have to  check whather std are available at CUNI.
    if it is.. you can create
    please go through these links..
    http://help.sap.com/saphelp_45b/helpdata/en/c6/f83bb94afa11d182b90000e829fbfe/content.htm
    Create Unit of measurement (MM)
    Create a new units of measure KG/cm2...
    How to create new unit of measurement
    You can add Iso codes also.... for that please go through the following link..
    How to add an iso code to table t006i
    Thanks....

  • Additional Unit of Measure

    I have my base unit of measure set as EA and in the additional unit of measure I'm trying to put a conversation to state that 1 EA = 165838 KG
    The system wouldn't allow that since the this field in the table only accepts 5 characters and 0 dec. (it also saves the digits in x,xxx format which means I can only give 4 digits).
    Is there anything to do to fix this? I can't store in Ton because it won't be accurate.
    Thank you

    Ideally your base unit should be the smallest unit or a small unit. In this case KG should have been the base unit.
    However, if you still wish to continue...
    try using 500 EA = 82919 TON (This is exact if 1 TON = 1000 KG)
    If it is not allowing 5 digits, and you are willing to have a minor approximation, you can use
    50 EA = 8292 TON. At 1 TON = 1000 KG, this works out to 1 EA = 165840 KG (A difference of 2 KG from actual figure).
    Hope this helps,
    Lakshman
    P.S. Dear Srao, changing the number of decimals in currencies and Units of measures is not recommended.

  • Error while defining alt unit of measurement in material master

    All SAP gurus,
    i am trying to define a alt unit of measurement in a finished material, the base unit of measurement is in MT, and the sales unit is nos. the conversion formula is 53 nos = 1kg i.e. 1MT = 53000 nos. as conversion can be done only with base unit of measurement i am giving 53000 nos = 1 MT, but system unable to calculate the conversion as it is not taking mere than 3 digit after decimal.
    e.g.    if 53000 nos = 1 MT
    then  1 nos should be = 0.000018 MT
    but system not taking this value as this value contain 6 digit after decimal
    suggest me what can be the way out? with detailed steps. can i increase the post decimal value or i have to define another middle alt unit of measurement (like KG). and if that is to be done then how.
    Regards
    BKR

    Hi,
    With help of Basis team check the decimal places for u r user ID.
    In t-code SU01 >>> Under Default tab
    Kapil

  • Error message 'Enter unit of measure' in Webclient

    Hello Experts,
    We are working on CRM 5.0 SP 7, IC WebClient and have implemented the BAdi "<b>CRM_SERVICEPROD_BADI</b>" to assign a service product ''<b>INVESTIGATION'</b> whenever user selects service ticket in WebClient.
    However, when confirming a Business Partner and accessing the service ticket, an error is getting displayed stating "<b>Enter the unit of measure</b>".
    We have already mentioned the unit of measure in Product but it seems it is not picking from there.
    Please help me to remove this error.
    Reward points assured for useful answers.
    Regards,
    Amit

    hi
    I had a similar Problem
    You will have to assign the base unit of measure in service tab as hours and then in the sales and distribution tab assign the same unit in the sales unit and give minimum order quantity(for e.g-1) & delivery unit ,this you will have to do for all the sales areas you might have mapped in the S&D tab
    I'm sure the issue will be resolved
    Cheers!!
    Regards
    Shankar Raj

  • How to retrieve the values from a table if they differ in Unit of Measure

    How to retrieve the values from a table if they differ in Unit of Measure?

    If no data is read
    - Insure that you use internal code in SELECT statement, check via SE16 desactivating conversion exit on table T006A. ([ref|http://help.sap.com/saphelp_nw70/helpdata/en/2a/fa0122493111d182b70000e829fbfe/frameset.htm])
    If no quanity in result internal table
    - There is no adqntp field in the internal table, so no quantity is copied in itab ([ref|http://help.sap.com /abapdocu_70/en/ABAPINTO_CLAUSE.htm#&ABAP_ALTERNATIVE_1@1@]).
    - - Remove the CORRESPONDING, so quantity will fill the first field adqntp1.  ([ref|http://help.sap.com/abapdocu_70/en/ABENOPEN_SQL_WA.htm])
    - - Then loop at the internal table and move the quantity when necessary to the 2 other fields.
    * Fill the internal table
    SELECT msehi adqntp
      INTO TABLE internal table
      FROM lipso2
      WHERE vbeln = wrk_doc1
        AND msehi IN ('KL','K15','MT').
    * If required move the read quantity in the appropriate column.
    LOOP AT internal_table ASSIGNING <fs>.
      CASE <fs>-msehi.
        WHEN 'K15'.
          <fs>-adqnt2 = <fs>-adqnt1.
          CLEAR <fs>-adqnt1.
        WHEN 'MT'.
          <fs>-adqnt3 = <fs>-adqnt1.
          CLEAR <fs>-adqnt1.
      ENDCASE.
    ENDLOOP.
    - You could also create another table with only fields msehi and adqntp and then collect ([ref|http://help.sap.com/abapdocu_70/en/ABAPCOLLECT.htm]) the data to another table.
    Regards,
    Raymond

  • Production Order for a Material with two units of measure?

    Hi Everybody I have the following issue.
    In my company there is a new production process with a Material that should be configured in the master data with the field "Base Unit of Measure" as per unit (each). But the production process, should be confirmed by tx CO11N, in Kilograms. I know that I can use the additional Data in tx MM03 to set a Production Unit, but the value of convertion would be fixed. For example 122 Kg = 1 each, the thing is that the value in kilograms for each lot can vary, one lot can weight 122 and another one can weghr 125, and in each case I shoul have two units in stock. And as I have the value of convertion fixed, when I confirm each lot one for 122 kg and another for 125 kg I will have 2.025 units in MB52.
    How can I solve this problems? I need to have the chance the confirm in kg changing for each lote the quantity but in the base Unit of Measure have one unit for lot. As if for tx CO11N I could have a field where I can set tha x quantity of Kilograms is x each.
    Kind regards
    Leandro. 

    Hi Ayoub, First thank`s for your promt answer,
    1. The Quantity is different, because is not a perfect process, there is a manual work in the process that makes this quantity differ, there is no big difference, maybe a Kilo or Two but the production mannager wants to have this registered. And besides in productions they manage kilograms, but for selling the comercials manage units (each - EA)
    2.The convertion rate is known at the end of the process after cutting and packaging a unit, they weight it.
    Regards
    Leandro

  • Standard report  for unit of measures

    Is there any standard report to see the Fert material unit of measures  and its alternate unit of measures.

    HI
    there is no standard reprot for you requirment.
    only UOM of material you canget from MM60.
    but if you want alternate also got with table data MARM
    1.use SE16-- enter the table name MARM
    2.enter the material(field MATNR), and execute you get the report
    -ashok

  • Report for Units of measurement for Material

    Hi
    Is there any report to extract the alterante unit of measurements for materials in a plant.
    Thanks

    Hi,
    Please use the below table,
    Related to Materials:
    MARA - Material Master: General data
    MAKT - Material Master: Description
    *MARM - Material Master: Unit of Measure*
    MAPE - Material master: Export control file 
    MARC - Material master: Plant data
    MARD - Material master: Storage location 
    MAST - Material link to BOM
    MBEW - Material valuation
    MLGN u2013 Material Master: WM Inventory
    MLGT u2013 Material Master: WM Inventory type
    MDIP - Material: MRP profiles (field contents) 
    MKOP - Consignment price segment (old versions of SAP)
    EBEW - Valuation of sales order stock
    QBEW - Valuation of project stock
    MVER u2013 Material Master: Consumption <Plant>
    DVER u2013 Material Master: Consumption <MRP Area>
    MVKE u2013 Material Master: Sales <Sales Org, Distr Ch>
    MLAN - Material Master: Tax indicator
    MARC - Material Master: Plant data
    MAPR u2013 Material Master: Forecast
    MARD u2013 Material Master: Storage Location
    MCH1 u2013 Material Master: X Plant Batches
    MCHA u2013 Material Master: Batches
    MCHB u2013 Material Master: Batch Stock
    MDMA - MRP Area data
    DBVM - MRP Planning File Entry: MRP Area
    MOFF - Outstanding Material Master Records (Maintenance status)
    MARCH - Material Master C Segment: History
    MARDH - Material Master Storage Location Segment: History
    MBEWH - Material Valuation: History
    MCHBH - Batch Stocks: History
    MKOLH - Special Stocks from Vendor: History
    MSCAH - Sales Order Stock at Vendor: History
    MSKAH - Sales Order Stock: History
    MSKUH - Special Stocks at Customer: History
    MSLBH - Special Stocks at Vendor: History
    MSPRH - Project Stock: History
    MSSAH - Total Sales Order Stocks: History
    MSSQH - Total Project Stocks: History
    Regards,
    Mohd Ali.

  • T006-Decan change after users have used the TO unit of measure

    Currently in our system for TO (tonnes) it has T006-Andec as 3 and T006-Decan as 0 and it issues the users a warning message "Order quantity violates rounding rule" if they type in decimals in the purchase order quantity.  We have been asked to change T006-Decan to a 3 and do away with the warning message.  What happens if you change T006-Decan from 0 to 3 after users have already used the unit of measure (TO) in the R/3 SAP_APPL 470 system on materials, purchase orders, sales documents, receipts, etc...?  I don't want to impact our users in production since I do not where this unit of measure has been used.  Any advice is welcomed.  Thank you.

    Hi
    If you are changing the decimal places in T006 - DECAN , the number which was 1000 would show as 1,000... so previously it was 1000 tonnes now it will show as 1 tonne.... such things happen....Check with SAP before doing changes to the Standard UOM's...
    I am not able to find the correct SAP note for this.... but its there hope you get it
    Thanks & Regards
    Kishore

  • Follow up material with different base unit of measure

    Hi all,
    I have the BOM with material Mat1 as a component. The base unit of measure of Mat1 is KG.
    Is it possible to replace Mat1 with Mat 2 material in MRP once the Mat1 warehouse stock is depleted.
    The base unit of measure of Mat 2 is KGK.
    The required quantity of MAT1 should be recalculated from KG to KGK accordanly unit ratio.
    Please, expain, where does it maintain?
    Thanks,
    Peter

    Hello Peter,
    You can use follow-up setting (set Mat2 as follow-up of Mat1 in MRP 4 view of material master if this follow-up scenario is valid for all BOM) with discontinuation indicator '1', w/o effective-out date. In this case Mat1's stock will run out (no PldOrd, PR, etc) will be created, and from the date, when Mat1's stock runs out, MRP will calculate with Mat2.
    As I told you, according to my best knowledge, you cannot realize this with different base unit of measures. (you have to change the buom of one of the related material masters or create a new material master if you cannot cope with buom-change).
    Follow-up group scenario can also be used but I guess different buoms will be a problem in that case as well.
    Maybe there are better solution but I'm not aware of it...
    BR
    Csaba

Maybe you are looking for

  • How do I use the maintenance service to upgrade PCs without admin rights?

    Our users do not have admin rights on their systems so FireFox is WAY out of date. I read about the Maintenance Service in the wiki and hoped it might allow FireFox to update itself without admin rights. I installed v21 and FireFox does not update it

  • Two of the same artists showing up on my ipod when I add 1 specific album

    OK so here's what's happening.  I downloaded a rolling stones album "Let It Bleed," off the internet.  And I made a file for it, put the songs in the file, and put the file in itunes. So I have ALL the songs, album artwork etc in itunes, but the song

  • PDF interactivity : page control issue (pdf file considered as a form)

    Hello there, I've got a slight but quite annoying issue when exporting a PDF from my InDesign CS3 file. Let me explain. The file is some sort of glossary with interactive content (such as a table of content, images with over effects and text with too

  • Smartform to pdf conversion and send as attachment

    Hi, my requirement is i have to change the smartform to pdf and send as attachment to mail id's. For specified smartform it is converting and sending as pdf but in my selection screen i have to give smartform name and mail id's. if i give any other s

  • MSI Clickbios IV

    I have very specifically ordered MSI boards for some of our security related appliances. The choice is based on the fact that all prior motherboards to the model we purchased 1) retained settings after upgrading the bios with LiveUpdate ...and 2) Cli