Disable all the input field in Manage Internet Access

I have find one error that when i use adobe reader with login from my window AD a/c, i cannot use the Adobe Reader Trust Manage because all input field are disable, it is not happen in early time, so could anybody help me to solve this, thx..

any one could help me?

Similar Messages

  • Making the input fields readonly

    hi
       iam  calling  a RFC  and it is a Custom  and not
    a pre-defined 
           and  now i need to show some data  of the  table 
         in the pop-up window   in the input fields  and all this
            fields should be readonly .  there are about  30 
           input fields and it difficult to make each and every input
    field  as readonly  ,  is there any alternative  that allows
      me too make the all the input fields readonly.

    Hi, Kishore,
    Even I tried the same but not successful. Because your container will not have Readonly propert so only way is to do it is doing for each and every element. for this also two ways are there.
    1. directly set the readonly property of each and every element in Layout tab or
    2. create a context variable of type boolean and map it to the readonly property of the UI.
    Regards,
    Srinivas.

  • In the component overview screen of CO01 I want  to disable all  the field in  screen of table control.I want to make it as output screen only.

    Hi all
      In the component overview screen of CO01 I want  to disable all  the field in  screen of table control.I want to make it as output screen only.
    Thanks & Regards,
    Rajib.

    Isn't that just exactly what transaction CO02 does? CO01 is for creating production orders so what sense does it make to have it display mode only?
    Maybe your goal is to stop then end user changing the component assignment that is automatically  detected by the system. If so, personally I think a better starting point would be PP configuration or user authorizations rather than looking to change the screen by whatever method. As we don't know what you are trying to achieve it's hard to offer much more advice maybe all you need is to change transaction to CO02

  • How to enable/disable the input fields based on the data entered/user action in the web dynpro abap?

    How to enable/disable the input fields based on the data entered in the web dynpro application abap?  If the user enters data in one input field then only the next input field should be enabled else it should be in disabled state. Please guide.

    Hi,
    Try this code.
    First create a attribute with the name readonly of type wdy_boolean and bind it read_only property of input field of which is you want to enable or disable.
    Next go to Init method.
    Set the readonly value as 'X'.
    DATA lo_el_context TYPE REF TO if_wd_context_element.
         DATA ls_context TYPE wd_this->element_context.
         DATA lv_visible TYPE wd_this->element_context-visible.
    *   get element via lead selection
         lo_el_context = wd_context->get_element( ).
    *   @TODO handle not set lead selection
         IF lo_el_context IS INITIAL.
         ENDIF.
    *   @TODO fill attribute
    *   lv_visible = 1.
    *   set single attribute
         lo_el_context->set_attribute(
           name =  `READONLY`
           value = 'X').
    After that Go to the Action  ENTER.
    First read the input field ( first input field, which is value entered field) , next give a condition
    if input value is not initial  then set the readonly value is '  '.
    DATA lo_nd_input TYPE REF TO if_wd_context_node.
         DATA lo_el_input TYPE REF TO if_wd_context_element.
         DATA ls_input TYPE wd_this->element_input.
         DATA lv_vbeln TYPE wd_this->element_input-vbeln.
    *   navigate from <CONTEXT> to <INPUT> via lead selection
         lo_nd_input = wd_context->get_child_node( name = wd_this->wdctx_input ).
    *   @TODO handle non existant child
    *   IF lo_nd_input IS INITIAL.
    *   ENDIF.
    *   get element via lead selection
         lo_el_input = lo_nd_input->get_element( ).
    *   @TODO handle not set lead selection
         IF lo_el_input IS INITIAL.
         ENDIF.
    *   get single attribute
         lo_el_input->get_attribute(
           EXPORTING
             name =  `VBELN`
           IMPORTING
             value = lv_vbeln ).
    if lv_vbeln IS not INITIAL.
        DATA lo_el_context TYPE REF TO if_wd_context_element.
        DATA ls_context TYPE wd_this->element_context.
        DATA lv_visible TYPE wd_this->element_context-visible.
    *  get element via lead selection
        lo_el_context = wd_context->get_element( ).
    *  @TODO handle not set lead selection
        IF lo_el_context IS INITIAL.
        ENDIF.
    *  @TODO fill attribute
    *  lv_visible = 1.
    *  set single attribute
        lo_el_context->set_attribute(
          name =  `READONLY`
          value = ' ' ).

  • All of the input fields in my browser, regardless of site, are very large while everything else is normal size. How do I fix this?

    All of the input fields in the browser are very large while other text is normal size. How do I fix this?
    In some cases some sites headers will run together and sometimes overlap. Other sites will just show a portion of the site in a vertical box but not the full width of the screen and I can't adjust it.

    Applications -> Utilities -> Audio MIDI Setup; select the desired output device and click on the gear icon at the bottom, select 'Play alerts and sound effects through this device'.

  • Education Edge -- Firefox update, 6.0.2, disables all the pull-down menus

    We use Education Edge software to manage attendance, grades, etc. at our school. The new Firefox update, 6.0.2, disables all the pull-down menus. They show up, but the fields are all empty. Fix? Is there a way to revert to the previous version which worked fine?

    I have this problem on my dual monitor system. I found a solution that works. Click Start, Run, sysdm.cpl
    In the resulting System Properties window, click the Advanced tab, then click settings under Performance. You will have one of four radio buttons enabled. Here what I did. I enabled "Adjust for For Best Appearance" and clicked apply. I then unchecked the box "Show Shadow under windows" and clicked apply again. Problem solved.

  • Higlighting the input field

    Hi Experts ,
    i want to higlight the input field based on some condition  , i tried using reporting attribute message ,
    but how to hide the MSG area ? higliting the input field is enough for me  .
    have a look at the below image .
    [http://i56.tinypic.com/119qnwn.jpg  |http://i56.tinypic.com/119qnwn.jpg  ]
    Regards
    Chinnaiya P

    Problem solved by my self .
    let me share the piece of code to hide  the msg area .
    if lv_field1 ne lv_field2.
    * get message manager
    DATA lo_api_controller     TYPE REF TO if_wd_controller.
    DATA lo_message_manager    TYPE REF TO if_wd_message_manager.
    lo_api_controller ?= wd_this->wd_get_api( ).
    CALL METHOD lo_api_controller->get_message_manager
      RECEIVING
        message_manager = lo_message_manager   .
    * report message
    CALL METHOD lo_message_manager->report_attribute_error_message
      EXPORTING
        message_text              = 'hiiia '
        element                   =  lo_el_context
        attribute_name            = 'FIELD2'
      receiving
        message_id                = msgid .
    * below code will reset the message .
    data: l_api_testcase1              type ref to if_wd_view_controller,
          l_api_wdr_test_msg_area      type ref to if_wd_window_controller,
          l_wd_message_area            type ref to if_wd_message_area.
      l_api_testcase1 ?= wd_this->wd_get_api( ).
      l_api_wdr_test_msg_area ?= l_api_testcase1->get_embedding_window_ctlr( ).
      l_wd_message_area = l_api_wdr_test_msg_area->get_message_area( ).
      l_wd_message_area->reset_messages( i_keep_current = 'X' ).
       endif .
    have a look to the solution arrived .
    [http://i54.tinypic.com/11gna4w.jpg|http://i54.tinypic.com/11gna4w.jpg]
    thanks for all those give your valuable suggesion
    Regards
    chinnaiya P
    Edited by: chinnaiya pandiyan on Jan 28, 2011 5:08 PM

  • How to get the values from the input field of a table

    Hello Friends
    I am having table having one column as InputField and rest are the textview fields
    I input the data and click the button that will add them to a node.
    But what is happening is it is adding the current value to all the fields replacing other filelds.
    Like suppose I am having 3 rows
    In column I input 10
    In column 2 input 20
    In column 3 input 30
    Now it is setting the value 30 to all the 3 fields.
    Can any one tell me the code to set 10, 20 and 30 as different value in a node as entered by me.
    Thanks

    Hi
    i am your scernario as follows
    Context
    TN_node (value node of cardinality 0:N)
                 val1 (value attribute under value node)
                 val2 (value attribute under value node)          
    i have binded Tn_node to table and val1 is textview and val2 is inputfield
    public void wdDoInit()
        //@@begin wdDoInit()
        for(int i=0;i<5;i++)
        IPrivateTestView.ITN_nodeElement ele=wdContext.nodeTN_node().createTN_nodeElement();
        wdContext.nodeTN_node().addElement(ele);
        ele.setVa1("val"+i);
        //@@end
    i have a button go in which printing all the values
    public void onActionGo(com.sap.tc.webdynpro.progmodel.api.IWDCustomEvent wdEvent )
        //@@begin onActionGo(ServerEvent)
        for(int j=0;j<wdContext.nodeTN_node().size();j++)
        //IPrivateTestView.ITN_nodeElement
        IPrivateTestView.ITN_nodeElement ele=wdContext.nodeTN_node().getTN_nodeElementAt(j);
    wdComponentAPI.getMessageManager().reportSuccess("-----"+ele.getVa1());
    wdComponentAPI.getMessageManager().reportSuccess("-----"+ele.getVa2());
    Hope this helps,
    If your problem is not solved please post your code like this
    Thanks and Regards,
    Arun

  • How can I disable all the components in a JPanel?

    I want to disable all the components( button, text field ) in a JPanel. I know I can search the panel and disable each of its children component recursively. Is there a better way to do this?

    I want to disable all the components( button, text field ) in a JPanel.You haven't defined what you mean by "disable".
    If you mean you want the component to be repainted in its disabled state, then you would need to set the property of each individual component to disable, which would imply some kind of recursion.
    If you just want to prevent components from receiving key events and mouse events, then you can use a glass pane or maybe a panel with an overlay layout that contains a non-opaque panel that intercepts all events.

  • Not able to display the values in the input fields of the view

    Hi All.
    I am facing an unique issue.
    My custom element created in my custom node getting a null value
    from a Get Vendor Details RFC written in RFC.
    The values are getting populated in the custom element but not coming in the
    input field of the corresponding view.
    Then, I wrote this code
    wdContext.nodeCustom.setLeadSelection(1);
    and all the output came in the input field.
    Now, after a build it is not coming in the input fields of the view.
    All my custom nodes are Singleton and values are coming in the custom elements
    as I can print them by wdComponentApi.getMessageManager.reportSuccess(""+customnode.getField());
    All my nodes are Singleton.
    Please give your valuable inputs.
    Regards
    Kaushik Banerjee

    Hi
    Check the node property
    initializeLeadSelection     true
    if not make it true , I would suggest to make a value node of the same structure as in RFC after execuation of the RFC populate the value manually.Dont bind it directly to the UI element.
    BR
    Satish Kumar

  • File Content Conversion -All the input content was not shown in output file

    Hi Experts,
    In my scenario, I need to send data from .XML file to .txt file, using File Content Conversion at Receiver communication channel. This is File to File scenario.
    This is my Input xml file.
    <ns:FILEINPUT_MT xmlns:ns="http://File2FileTest">
      <RECORD>
        <Row>
          <FirstName>Susie</FirstName>
          <LastName>Tony</LastName>
          <City>London</City>
          <Country>UK</Country>
        </Row>
      </RECORD>
    </ns:FILEINPUT_MT>
    <b>Processing Parameters</b>
    Target Directory = C:/Test
    File Name Scheme = xi_output.txt
    File Construction Mode = Add Time Stamp
    File Type = Binary
    <b>Content Conversion Parameters</b>
    Recordset Structure : RECORD
    RECORD.endSeparator = ‘nl’
    RECORD.fieldSeparator = ;
    After ‘Activate’ and providing the input xml file, xi_output.txt file was generated. But the file content was shown only with ‘Susie’ i.e. with First Name only. I need xi_output.txt file should have all the four fields (FirstName, LastName, City, Country)
    Could some one help me to resolve the issue?
    Thanks in advance
    Sree

    Check these blogs...Might help you.
    /people/venkat.donela/blog/2005/03/02/introduction-to-simplefile-xi-filescenario-and-complete-walk-through-for-starterspart1
    /people/venkat.donela/blog/2005/03/03/introduction-to-simple-file-xi-filescenario-and-complete-walk-through-for-starterspart2
    /people/venkat.donela/blog/2005/06/08/how-to-send-a-flat-file-with-various-field-lengths-and-variable-substructures-to-xi-30
    /people/anish.abraham2/blog/2005/06/08/content-conversion-patternrandom-content-in-input-file
    /people/arpit.seth/blog/2005/06/02/file-receiver-with-content-conversion
    /people/shabarish.vijayakumar/blog/2005/08/17/nab-the-tab-file-adapter
    /people/jeyakumar.muthu2/blog/2005/11/29/file-content-conversion-for-unequal-number-of-columns
    /people/shabarish.vijayakumar/blog/2006/02/27/content-conversion-the-key-field-problem
    /people/sap.user72/blog/2005/01/06/how-to-process-csv-data-with-xi-file-adapter
    /people/michal.krawczyk2/blog/2004/12/15/how-to-send-a-flat-file-with-fixed-lengths-to-xi-30-using-a-central-file-adapter
    Link for SAP Help
    http://help.sap.com/saphelp_nw2004s/helpdata/en/2c/181077dd7d6b4ea6a8029b20bf7e55/content.htm

  • Clearing the data buffer from the input fields

    Hi,
    I am using an user exit CONFPP02 for the Tcode: co11n. I have written a program such that the confirmation numbers having the status CNF will not be allowed to be processed. The whole confirmation is terminated when the system checks the confirmation number and its status as CNF. If the status of the confirmation number is PCNF, the program allows the further processing of the Tcode Co11n.
    The problem starts when the user enters the PCNF status confirmation number and enters, the system stores the values in the various input fields. Now without exiting the initial confirmation screen, if the user replaces the Confirmation number of the PCNF status to the Confirmation number of the CNF status , the system issues a warning message:"  Confirmation no. or order/sequence/operation has been changed
    However, the input fields still contain default values from thepreceding confirmation". if the user says yes, the program written is bypassed , thus allowing the reconfirmation of the CNF confirmation number  into PCNF confirmation number .
    Can anybody suggest a suitable method to clear the data stored defultly in the input fields so that the program can be made to work.
    With regards,
    Avinash.S
    Mobile no:09996192456

    Hi Gilad,
    I never use Preview and did not use Preview at all before sending the document over to my most recent client either.
    I only opened Preview up this morning after I discovered that all of the form data had disappeared on his end! And the only reason I opened up Preview was because I already knew it looked fine in Acrobat so wanted so wanted to view the form in a different application.
    My client would not even have notified me about it had he not sent the signed form back to me and I saw there was no data there! I then called him and asked him about the missing data and he said that he thought I had simply sent over the form purposely with blank fields:(
    I have just emailed him to ask him what application he opened it up in. My understanding is that he is on Windows because ne mentioned to me his company was using Windows when we last spoke. Perhaps he has a personal Macbook where he opened it? I just don't know and can hopefully soon find out:)
    But THANK YOU for letting me know about that script! I appreciate it:) I have now downloaded and installed it and will just have to use it on ALL of my forms before sending them out:)

  • In BSP how to give the input field as mandatory?

    Hi friends,
    In BSP how to give the input field as mandatory?
    In BSP i want to validate the input field (example checking the material no is valid or not)
    if this material no doesnot exit means i want to pass error message.What is the code for that.
    Moosa

    hi
    try this
    in LAYOUT
    <htmlb:inputField id = "vname"  disabled = "False" value = "<%= v_visitor %>"/> <font color="red" size="2"><b><%= page->messages->assert_message( 'vname' ) %></b></font></td>
    in DO_HANDLE_EVENT
    in oninputprocessing
    CLASS CL_HTMLB_MANAGER DEFINITION LOAD.
    IF event_id = CL_HTMLB_MANAGER=>EVENT_ID.
      DATA: event TYPE REF TO CL_HTMLB_EVENT.
      event = CL_HTMLB_MANAGER=>get_event( runtime->server->request ).
      IF event->name = 'button' AND event->event_type = 'click'.
        DATA: button_event TYPE REF TO CL_HTMLB_EVENT_BUTTON.
        button_event ?= event.
      ENDIF.
        case event->id.
            when 'select'.
               if v_visitor = ''.
                 page->messages->add_message(
                 condition = 'vname'
                 message   = 'Visitor Name can not be blank'
                 severity  = page->messages->CO_SEVERITY_ERROR ).
              ELSE.
                    here u can write ur when ur field getting filled
            endif.
         endcase.
    endif.
    give marks if it is helpful
    thanks

  • The list doesn't appear in the input field

    Hi All
    The list doesn't appear in the input field when I make input or press the BACKSPACE key.
    Notes:
    I made this modifications:
    1. In connection properties I set High speed connections (LAN)
    2. In local data settings I set the historial to ON
    we had SAPGUI 620 in workstations and now we have installed SAPGUI 710
    Thanks for your time and help
    Message was edited by:
            Genner Sanchez

    Hello Genner,
    see note 399180:
    o  FIELD NAME LENGTH
       The history is only written for field names with a maximum length
       of 40 characters. In earlier SAP GUI versions, this length was
       restricted to 30 characters. The history file must be deleted to
       achieve extended support.
    o  FIELD LENGTH
       If the length of the input field is 60 or more characters,
       history is not written either. "Input field length" refers to the
       dictionary length of the field, not to the "visible length" on
       the screen. (The restriction of the input data to 60 characters
       results from the fact that text editors were often built as lists
       of text fields with a length of 60 in the past. In those editors,
       this history was quite annoying.  On customer request, this was
    Regards, Martin

  • How to keep the input field from PDF Form to RTF

    Hi,
    I'm looking to keep the input fields from my pdf form document to Rtf so I can use them in my Rtf document.
    Regards,
    Alan

    Good day Alan,
    I'm afraid that's not possible as form fields in a PDF file have no equivalent either in a Word format (.docx/.doc) or within the Rich Text Format (.rtf).  That data is simply stripped during the conversion as there's no equivalent available.
    Kind regards,
    David
    Acrobat Community Manager
    Adobe Systems

Maybe you are looking for

  • Button at right side of page.

    I want to add a button at Top right side of Page. I want to go with Page Button because they have behaviour to add top and bottom of Page. I dont know why Horizontal alignment property for submit button is not working . Thanks ,Avaneesh

  • Display null values in crosstab report.

    I have a crosstab that will be sparsely populated.  The datatype of the cells in the crosstab are numeric.  I would like to have the cells that contain no data to have no value, but Crystal Reports inserts a zero there instead. Is there anyway to tel

  • Problem to create an ip range collection on sccm 2012 sp1

    Hi everybody, I need to create an ip range query to a collection, i saw a lot of explanations: I create this query for the ip range 10.201.0.50 10.201.0.254 select * from  SMS_R_System where  IPAddresses like "10.201.0.[5-9][0-9]"             or IPAd

  • How to resolve VAT triangulation determination in CRM 70

    Please adjust SAP CRM so that it supports external tax software packages like Vertex.  There are at least two scenarios to be considered for VAT.  The first is a direct sale from seller to customer where there are no triangulation issues: Bentley Sys

  • Install scripts on network?

    Hello! I have a few scripts that I've written for my boss, who runs a photography studio. He has several computers in his office that will need to be using the scripts. Obviously, he has a network to share files and whatnot, is there any way to share