Does anbody have labview drivers for Tenney Temperatur​e Chambers?

When I run the Measurement and Automation program, I can detect the instrument, but when I send a query to it, "*IDN?" it says the instument did not respond to the query string!
Does anyone have a vi that will control this chamber?
Or some idea on why I can not communicate with it?
Thanking you all in advance,
D.S

Hi D.S.
The fact that the chamber is not responding to the *IDN? doesn't mean that you cannot communicate to it. Since MAX is detecting the device, this means that the device responds to the controller commands and performs the appropriate handshake to accept bytes. The device is most likely not responding to *IDN? because it doesn't recognize the command.
You should refer to the chamber's documentation to determine what commands it accepts and recognizes.
DiegoF
National Instruments.

Similar Messages

  • Does anyone out there have LabVIEW drivers for either a Z-Mike 1102 (Beta Lasermike) or a Compumotor 6104 (Parker)?

    Does anyone out there have LabVIEW drivers for either a Z-Mike 1102 (Beta Lasermike) or a Compumotor 6104 (Parker)?

    CompuMotor creates a Motion Toolbox for LabVIEW, but it is not supported by National Instruments.
    You can find some support files and downloads for the 6104 from http://www.compumotor.com/support_samples.htm

  • Does HP have Lion drivers for the Scanjet 4600?

    It looks to me as though the latest Mac OS supported by HP Scanjet 4600 is Tiger.
    Any suggestions?

    IAW the HP web site, no.
    http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us &prodNameId=303778&prodTypeId=15179&prodSeriesId=303776&swLang=8&taskId=135&swEn vOID=219

  • Labview drivers for Omega OM-DAQ-USB-2401

    This DAQ is a thermocouple/voltage input USB device. Omega does not provide Labview drivers for it, but it does have .NET/API drivers for Visual Basic, C#, and Visual C++. Has anyone been able to build a driver for this device in order to get measurements from it in Labview? I've read the USB Instrument Control Tutorial, but am not sure if this would be of any help with this type of device. I simply want to use the DAQ output (voltage measurement) as a variable in Labview to control other devices with an NI 9472. 

    I have not used these specific devices, but I have used a lot of Omega product in the past and they tend to sell good stuff. They do have a tendency to resell a lot of stuff too. So one thing that might be worthwhile is to see if this box is really theirs or if they are reselling hardware from somebody else.
    Having said that, give the .net a try. The examples in the other languages should give you the basic flow of what calls you need to make to accomplish common tasks -- like reading a value.
    Mike...
    PS: it also might be interesting to plug the thing in to your computer and after letting it load whatever drivers it needs, see what kind of device the OS thinks it is.
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Labview Drivers for an Integral Tech Framegrabber

    My company is interested in purchasing a video inspection system that
    uses the following frame grabber:
    http://www.integraltech.com/art/downloaded%20from%20current%20site/fbmv/documents/fbmvlitespecsheet.pdf
    Integral Tech does not make Labview drivers for this card.
    Would there be a way to get these written, or would that be cost
    prohibitive ?
    Thanks for any suggestions.
    Rick B.
    Email: Use Yahoo instead.

    Hi Rick,
    I'm not really sure whether this is what you're thinking of but...
    Since INTEGRALTECH provides a VFW driver for their frame grabber you could,
    e.g., use this tool from aNI server:
    http://exchange.ni.com/servlet/com.quiq.servlet.GetObject/lv_vfw.zip?KEY=101
    ..97.12134.14&SIG=101.97.12134.14&EXT=mime:application/x-zip-compressed
    It works very well but, like any VfW based application, has the disadvantage
    of being able to read out only one camera at time. If you plan to use
    multiple frame grabbers simultaneously you have to find a different
    solution.
    It should also be possible to call the DLLs INTEGRALTECH provides from
    LabView.
    Best regards
    Arno
    "Rick B." schrieb im Newsbeitrag
    news:[email protected]..
    >
    My company is interested in purchasing a video inspection system that
    > uses the following frame grabber:
    >
    >
    http://www.integraltech.com/art/downloaded%20from%20current%20site/fbmv/docu
    ments/fbmvlitespecsheet.pdf
    >
    > Integral Tech does not make Labview drivers for this card.
    >
    > Would there be a way to get these written, or would that be cost
    > prohibitive ?
    >
    > Thanks for any suggestions.
    >
    >
    > ---
    > Rick B.
    > Email: Use Yahoo instead.

  • Are there LabVIEW drivers for the MCC USB-501 temperatur​e logger

    I am looking to purchase the MCC USB-501  and use it to acquire the ambient temperature on an event driven basis. The data logging portion is something I am interested in, I just want to have my application acquire the tempture when a certain event occurs. Does anyone have any LabVIEW drivers for this device?

    I don't know what you mean by using a logger that collects data on an "event driven basis".
    It is nifty little device, but it basically does one thing.  It logs data.  You load the software, configure it for when to start an how often to log data, unplug it, and put it where you want to log the temperature.  When you're done, you get it plug it back in and download the data that was logged.
    There is no way to configure it to react to events.  It's possible that a LabVIEW driver exists for this, but all it would do is provide an alternate way of downloading the data instead of using the software that comes with it.  It is not an immediate or interactive piece of hardware like a normal data acquisition card would be.

  • Looking for LabVIEW drivers for Aritsu MS462XX VNA?

    I'm looking for LabVIEW drivers for the Anritsu model MS4623D Vector Network Analyzer?  Have gone to Aritsu's site and downloaded their tools but no LabVIEW source found.   The other thing is whether anyone's developed LabVIEW interfaces to theirTools (Navigator or Power Tools or SCE)???

    Hi,
    Unfortunately, we do not have an instrument specific driver for this Anritsu model MS4623D. Here is a link to the drivers we do have for Anritsu. We may be able to get communication to your device threw another means. How does your device communicate? For example is it GPIB or Serial. We may be able to use an NI driver and a programming manual for your device and communicate with it in LabVIEW threw this.
    Regards
    Krista S.
    Applications Engineering
    National Instruments

  • LabVIEW Drivers for Instruments on DIN-Messbus

    I'm trying to interface to a group of instruments supplied by Rabe Messtechnik in Germany. They are networked through the DIN-Messbus protocol. Are there any labVIEW drivers for the following instuments or the protocol itself?:
    PPM-60, PIT-1500, PDM-02, PWS-02, CIO-26, PNC-02, PSW-02.

    Unfortunately I was unable to find a driver for this instrument. Instrument drivers can be found on our website
    www.ni.com/idnet
    by searching for a specific instrument name.
    If you cannot find the driver by doing this, then you have couple of options. First, I would like you to submit a request for this driver at:
    http://www.ni.com/devzone/idnet/other.htm
    We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://www.ni.com/devzone/idnet/development.htm
    We also have a syndicat
    e of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would suggest contacting one of the Alliance members at:
    http://www.ni.com/alliance
    I hope this helps.
    Kim L.
    Applications Engineering
    National Instruments

  • Labview drivers for agilent e4432b ,can`t find way to control multitone ???

    labview drivers for agilent e4432b ,can`t find way to control multitone ???How to deal with it
    Solved!
    Go to Solution.

    Hello Brownheart,
    Drivers for box instruments are not meant to cover all applications of an instruments use, only the most common uses. Regardless of discussing whether multitone is a common use for this instrument, a cursory examination of the available functions in the driver does not reveal this functionality.
    What you will have to do is create your own config VI using the information from the programming manual of the device. Not ideal, but at least the provided NI driver gives you a starting point from which to add this functionality.
    Regards,
    Dan King

  • LabVIEW drivers for Newport 2010A tunable diode laser?

    My group aquired a Newport 2010A tunable diode laser and failed to receive the labview drivers for remote control operation.  Does anyone have this software?

    All,
       Here is a link to a clean photocopy of the EOSI 2010 laser manual:
    https://wiki.brown.edu/confluence/download/attachments/29406/Diode+Laser+Manual.pdf?version=1
       You can also Google it using "EOSI 2010 laser" and find the maual in the link that says: "EOSI tunable laser diode systems and accessories are guaranteed
    for a period .... the 2010 laser diode. The first
    method is more sensitive but requires both .."  Good hunting.
    Sincerely,
    John Zehnpfennig
    U-Michigan Optics Lab

  • Labview drivers for Zeiss A1 Microscope motorized stage

    Hi,
    Anyone tried to control the motorized stage of Zeiss Axioobserver A1 using Labview before? We have one in our lab. I am trying to get it work recently. I found NI has labview drivers for Zeiss Z1 and M1 model. The Z1 is the fully motorized version of A1 we have. So I think they should have the same motorized stage. But the Labview stage control drivers for the stage on Zeiss Z1 does not work for our stage. Has anyone done this before? Thank you!

    Hi Cole,
    The Labview version I have is 2010. The VISA version I had before is 4.1 so I updated it to 5.1.2. But I still met the same problem. The microscope is connected to the computer via a USB/CAN converter. I put the screen shot of this USB in attachment. When I try to run it from the VISA interactive control, it shows the error:Could not perform operation because of I/O error. (in the attachment)
    I can detect this USB from the drvier wizard (see attacment3 ). But when I click next and install the inf files, it shows an error window (see attachment 4). This problem does not happen before I updated the VISA from 4.1 to 5.1.2. I have the inf file generated from the VISA 4.1 version (see attachment 5 and 6). But I can not generate the file from the 5.1.2 version. Will that be a big problem?
    Do you have any ideas about this? 
    Thank you very much!
    Best
    Wei
    Attachments:
    USB.png ‏78 KB
    USB2.png ‏72 KB
    USB3.png ‏48 KB

  • LabView drivers for Agilent 54830B scope or E4402B Spectrum Analyzer?

    Where can I find LabView drivers for the Agilent 54830B scope and the E4402B spectrum analyzer, or at least a driver for another instrument in the same families that I could modify? There are none on the NI site or the Agilent site.

    One thing that I have done several times is get a LabWindows CVI
    driver from Agilent. You will be provided with a .fp file. LabVIEW
    has a link under the Tools>>Instrumentation menu that allows you to
    "Import CVI Instrument Driver." This will take the function calls
    from CVI and build a set of VI's with the same name. The vi's will be
    wrappers for a dll that is used by CVI and other text based languages.

  • Labview drivers for Prisma QMS

    Hi,
    I'm looking for labview drivers for the Prisma Quadrupole Mass Spectrometer
    from Pfeiffer Vacuum. If possible also a simple rest gas analysis (RGA) VI.
    Can anyone help?
    Hans Rosink

    There is no driver available as the qmg220 uses OPC communication you can use labviews build in OPC functions.
    But the problem is that the "normal" labview OPC functions using datasoket are a little bit limited and when you need to adress many OPC items it may crash.
    Therefore NI is producing the LABVIEW DSC module which is avialable for extra money and with the main problem that you are not able to build stand alone applications without any extra licencing costs. Which makes problems if you want to sell your software or add it to the instrument you sell.
    On the other side the DSC module is a little bit to powerfule for the communication with the QMG220.
    Because of these arguments we decideed to use a OPC developement toolkit from Softing . 
    We started with the .NET developement but there4 was a reasonable memeory leak in Labview when using .NET event callbacks.
    This has been solved with Labview 2009f2 and up versions.
    Up to now we have made our communication with the Softing ActiveX control within labview.
    Now we are on the  point to switch bak to .NET. 
    When try the OPC connectivity from any third party opc API vendor and you are using a remote OPC from labview please tonst forget to add the line.
    ole.AuthnLevel = 1 to your labview.ini file. 
    Hope this gives you a first overview.
    We are not planning to build a easy to use driver for the QMG220 but we build a lot of vi's to control some functions and collect the data.
    Best regards
    Gernot 

  • HP does not show any drivers for my P1006 under windows 10

    My Laserjet P1006 will not work now that I am using windows 10. HP does not show that they have new drivers for my P1006. Will HP be coming out with new drivers.

    Hi,Drivers should beocme available for Windows 10, as you may find listed below:http://support.hp.com/us-en/document/c04658195 In the meantime connect the printer and try following the HP Printer Install Wizard, it may detect a compatible driver for yoru printer:http://h20180.www2.hp.com/apps/Nav?h_pagetype=s-926&h_lang=en&h_client=s-h-e016-1&h_keyword=dg-PIW If that fails you may also try installing the Windows 8.1 drivers, there are good chances those will work on Windows 10:http://ftp.hp.com/pub/softlib/software12/COL21058/bi-55362-7/ljP1000_P1500-HB-pnp-win64-en.exe Regards,Shlomi

  • I have a late 2008 white macbook.  I have a mini dvi to hdmi adapter, and a hdmi cord.  My cannot get my MB to detect an external monitor.  Nothing happens when plugged in.  Also, my display settings does not have an option for mirroring or arrangment tab

    I have a late 2008 white macbook.  I have a mini dvi to hdmi adapter, and a hdmi cord.  My cannot get my MB to detect an external monitor.  Nothing happens when plugged in.  Also, my display settings does not have an option for mirroring or arrangment tab

    Yeah, I'm having the same exact problem - It seems that the thunderbolt minidisplay port is only able to output the analog VGA signal, not the digital signal to support DVI and HDMI. This is a bug that came up after installing 10.7.1. I bought my macbook air with 10.7 on it, upgraded it to 10.7.1 as soon as I got it, so I have never been able to use hdmi or dvi with my macbook air. This is an extremely frustrating problem for me, I used HDMI on a daily basis with my PC. I have spent many hours at the genius bar running diagnostic tests so Apple can get as much information as possible to create a fix for this problem. I have been emailing tech support for 3 or so weeks now, they keep saying that they are working on a fix and it should be out soon, but 10.7.2 has come and gone and I still have no HDMI functionality with my MacBook Air!

Maybe you are looking for