Does Catalyst 2950 support SNA traffic ?

hello
we are trying to integrate some legacy sna hosts
to switching enviromnent.
we are faced to a strange symptom when legacy hosts
are connected to 2950 switch no traffic sna pass thru
we checked vlan,ports ,STP, but didnt found any hints
removing 2950 from configuration clear out the problem.
so simple diagram
7206 ==wan===7206=ethernet HUB=legacy sna host OK
----DLSW----> -------SNA------>
7206==wab===7206==CAT2950===legacy sna host NO OK
-----DLSW----> ---------SNA----->
are they any issue on 2950 for SNA traffic .
thanks in advance
JYP

Hi,
in general, No. There are no general issues with sna and a cat2950. The switch doesnt care what type of traffic runs through.
Besides the obviouos, the client and the dlsw router
must be in the same vlan.
There are sometimes problems with a switched environment. I.e if you do trunking with dot1q between the switch and the dlsw router and you use the switch in a mode where it tries to autonegotiate the trunk. Dlsw forwards some of the negotiation packets which leaves the switch in a state where the connections dont work.
We have also seen a problem in some situations where a dot1q trunk is used when the switch is configured for PVSTP, per vlan stp. In that case a special type of bpdu's is send which are also get forwarded by dlsw and can cause the switch on the other end to go to blocking ect.
All of those problems can be fixed by either putting a sap filter onto the bridge group on the dlsw router and only allow the sna saps you need or adopt the switch configuration. I.e. turn of autonegotiation of the trunk mode ect.
The issue needs to be looked at individualy and i would advice to open a case with the tac and work on this problem. So that we can understand what the problem is and fix it.
thanks....
Matthias

Similar Messages

  • Catalyst 2950-EMI, QoS, traffic classification and shaping

    Dear All,
    Can 2950-EMI perform traffic classification and shaping?
    Let's say I have some workstations attached on my 2950 and I want to perform traffic classification and shaping on the uplink based on the IP address of workstations.
    Thanks a lot.
    mak

    Shaping is not supported. But you can classify and use policing instead.
    http://www.cisco.com/univercd/cc/td/doc/product/lan/cat2950/12120ea2/2950scg/swqos.htm

  • Does IP Plus support SNA DLSw

    I'm not sure which IOS to run on a router. I need IPSec 3DES and DLSw. What IOS do I need for a 3745?
    Also, what IOS do I need for a 1720, same requirements?
    Thanks

    For 3745, IP Plus (i.e. IP PLUS IPSEC 3DES to get DLSw and 3DES) supports DLSw. For 1720, you need IOS with IBM feature (i.e. IP/IPX/AT/IBM/FW PLUS IPSEC 3DES to get 3DES and DLSw) set to support DLSw.

  • Cisco ISE and Catalyst 2950

    Hello!
    Please, could you help me? Is it possible to install ISE on Catalyst 2950? In Component Compatibility Guide
    http://www.cisco.com/en/US/docs/security/ise/1.0.4/compatibility/ise104_sdt.html
    Catalyst 2950 only support 802.1X and VLAN.
    At first I need to know about VLAN change(from resticted to corporate). Is Catalyst 2950 support it?
    Thaks for help!

    this would let both user and machine authenticate. for"5434Endpoint conducted several failed authentications of the same scenario" check  Suppress Anomalous Clients option.  This issue comes in to picture when endpoint attempts a couple of failed authentications and if Suppress Anomalous Clients option with Reject Requests After Detection is enabled then  ISE Policy nodes protect themselves from overwhelming numbers of authentication requests by sending an immediate reject for suppressed clients as opposed to processing all the steps in a normal authentication. So if that user did some authentication failure, he will be locked for 1 hours (bydefault).

  • Cisco Catalyst 2950/2960/3750 Multicast Traffic Preference

    Hello all,
    we, as a student company act as an ISP for university dormitories. We would like to (if it's possible) deploy QoS to prefer multicast traffic over all other types of traffic. 
    Devices used in network:
    Acces layer: Cisco Catalyst 2950,  12.1(22)EA14
    Dristribution layer: Cisco Catalyst 2960G, 12.2(58)SE1 
    Core layer: Cisco Catalyst 3750G, 12.2(52)SE
    Do you see any possibility to solve this with these devices? We have almost no experience with QoS, therefore any help would be greatly appreciated. 
    Thanks in advance.

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    Hmm, I think it should be doable although the 2950s, if non-E variants, are especially weak in QoS features.  I.e. those might create some issues.
    With the 2960G and 3750G, you often will create problems when you enable QoS because QoS, by default, allocates its buffers resources for 4 egress queues per port rather than using all for 1 egress queue per port.  However, this can be countered by QoS parameter tuning, but that takes some QoS expertize to match to your traffic and your overall QoS policy.

  • Does iphone supports IPv6 traffic for icloud?

    Hi Everybody,
    Does iphone supports IPv6 traffic for icloud application?

    ckuan
    The question was whether iPhones supports IPv6 protocol. Why would it matter if the network supports IPv4, IPv6, Dual stack or any other protocol? The straight answer is NO it does not as of today (even if the users have to worry about it or not, which is irrelavent imho).
    regards, sajith
    http://www.kaimals.com/

  • Does facetime supports IPv6 traffic?

    Since all  ISP's started IPv6 deployment, just wanted to know whether Facetime supports IPv6 traffic?

    ckuan
    The question was whether iPhones supports IPv6 protocol. Why would it matter if the network supports IPv4, IPv6, Dual stack or any other protocol? The straight answer is NO it does not as of today (even if the users have to worry about it or not, which is irrelavent imho).
    regards, sajith
    http://www.kaimals.com/

  • Catalyst 2950 Series - Monitoring Port

    Do the catalyst 2950 series have a port that can be used to connect a device that is designed to monitor all traffic on the switch - we are looking to install Webspy to track network & internet usage. The Sentinal product would best be connected to the switch where it can record all traffic - it needs a monitor port or some such equivalent.

    Hi,
    The 2950 does indeed support that - the functionality is called Switch Port Analyzer (SPAN). The following link has details on how to configure it:
    http://www.cisco.com/en/US/products/hw/switches/ps628/products_configuration_guide_chapter09186a00800d84c5.html
    Hope that helps - pls rate the post if it does.
    Paresh

  • Help with Catalyst 2950 G

    Hi,
    I have a doubt about the Catalyst 2950 series, i need to pass both IP and OSI traffic trought a 2950 switch. Is it supported?
    Thanks

    The 2950 is a layer2 switch. Anything carried over ethernet will go, no matter which layer3 protocol is used.
    Regards,
    Leo

  • Catalyst 2950 interface problem

    Hi, Sirs.
    My Catalyst 2950-24 (IOS Ver 12.1.22EA7)stops communicate with an other switch port of a Catalyst 3512XL-EN after catalyst 2950 powered on 1 or 2 days.
    th show interface shows that 2476498 ignored.
    FastEthernet0/1 is up, line protocol is up (connected)
    Hardware is Fast Ethernet, address is 000d.28c0.cf41 (bia 000d.28c0.cf41)
    MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
    reliability 255/255, txload 1/255, rxload 1/255
    Encapsulation ARPA, loopback not set
    Keepalive set (10 sec)
    Full-duplex, 100Mb/s, media type is 100BaseTX
    input flow-control is unsupported output flow-control is unsupported
    ARP type: ARPA, ARP Timeout 04:00:00
    Last input 3d19h, output 00:00:00, output hang never
    Last clearing of "show interface" counters never
    Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
    Queueing strategy: fifo
    Output queue: 0/40 (size/max)
    5 minute input rate 28000 bits/sec, 44 packets/sec
    5 minute output rate 0 bits/sec, 0 packets/sec
    10033048 packets input, 806430104 bytes, 2476489 no buffer
    Received 10031591 broadcasts (0 multicast)
    0 runts, 0 giants, 0 throttles
    0 input errors, 0 CRC, 0 frame, 0 overrun, 2476498 ignored
    0 watchdog, 2217265 multicast, 0 pause input
    0 input packets with dribble condition detected
    357799 packets output, 25835259 bytes, 0 underruns
    0 output errors, 0 collisions, 2 interface resets
    0 babbles, 0 late collision, 0 deferred
    0 lost carrier, 0 no carrier, 0 PAUSE output
    0 output buffer failures, 0 output buffers swapped out
    what does is mean?

    Hello,
    what other switches do you have in your network ? If you have just the 2950 and the 3500, make sure that the 2950 is the root switch for all your VLANs, by configuring the global command:
    spanning-tree vlan x priority 0
    Also, check the log on the 2950 for the following message:
    SCHAN ERROR INTR: SRC=6 DST=5 OPCODE=20 ERRCODE=5
    If you see those, chances are that you have a faulty unit. Here is the relevant bug info:
    CSCdv83336 Bug Details
    Under certain level of traffic load, the (2950) switch will start logging the following messages on the console:
    SCHAN ERROR INTR: SRC=6 DST=5 OPCODE=20 ERRCODE=5
    and after a few seconds, the switch will stop passing any traffic. In some cases, the switch seemed still forwarding broadcast and multicast traffic, which will cause STP problem if the switch has redundant link and is not supposed to be the root for the VLAN, as both port will go forwarding.
    The same error message has been identified in CSCdu87836.
    An assessment of the impact
    Unit stops passing any traffic.
    WORKAROUND
    Several units were returned by CISCO. The units were re-screened to the latest test program, and failed the SDRAM memory test.
    Customer should RMA unit back to Cisco
    Regards,
    Nethelper

  • Catalyst 2950 - Radius

    Is it possible of crypter the password radius-server on a catalyst 2950. (example: "radius-server key 7 toto")?

    Tagging on to this discussion from another thread in the forum:
    Actually the answer to this question is very highly release dependent. Earlier releases did not support it. Current releases do. I am not sure where the change is and believe it may be a 12.3 (or maybe even a 12.3T) enhancement. I have quite a few routers (most with TACACS and some with Radius) where the key is encrypted. When I started with those routers the key was not encrypted. At some point in doing a software version upgrade the keys for TACACS/Radius started being encrypted.
    The encryption of the TACACS/Radius key is part of the service password encryption. The service has been enhanced several times to increase the number of keys that it protects. If you have service password encryption enabled (and in a live network I hope that you do) and have a release that supports the new enhancement your TACACS/Radius key will be encrypted automatically. If your version of IOS does not support it yet the key will not be encrypted.
    HTH
    Rick

  • SNMP on Catalyst 2950 switch - possible?

    How can I add SNMP to my Catalyst 2950 switch? and what will this give me with regards to network monitoring etc. A lot of my networks go through this device and I what to get stats on port etc. I really hope you can help here.

    Hi Chandru,
    Here's what you should do. Firstly, go to the following site which will give you a list of MIBs supported on the 2950:
    http://www.cisco.com/en/US/products/hw/switches/ps628/products_configuration_guide_chapter09186a00800d84cc.html
    Then, open up the Cisco SNMP Object Navigator at:
    http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?local=en
    Within that, click on 'View and Download MIBs' and then select the MIBs you are interested in to download/view them.
    As an example, you can get counters on memory pools from the CISCO-MEMORY-POOL-MIB
    Hope that helps - pls rate the post if it does.
    Regards,
    Paresh.

  • Cisco devices that support Multicast traffic?

    Folks,
    I am looking for list of Cisco devices that support Multicast traffic. Does anyone know how to get this information?
    Thanks,
    Nagesh 

    Cisco Feature Navigator

  • Catalyst 2950 Switch flash_init error

    Hi Everyone,
    I'm new to Cisco products and have a small home lab set up. I have a Catalyst 2950 switch that I would like to restore to factory defaults. Here is the issue I'm having and can't figure out.
    I pull the power, telnet into the console port, hold the mode button and restore power. The boot loader (Version 12.1(11r) starts and says the usual message the system was interrupted prior to flash initialization (Paraphrasing here)
    I get to the switch: command line, enter flash_init. Flash states it initialized and then all I get is a < with an underscore under it prompt. Anything I try to type comes up as bizarre characters and I can not get back to a switch: prompt unless I reboot the switch manually. Unsure of what to do here.
    Thanks in advance!
    -Matt
    Telnet session:
    C2950 Boot Loader (C2950-HBOOT-M) Version 12.1(11r)EA1, RELEASE SOFTWARE (fc1)
    Compiled Mon 22-Jul-02 18:57 by antonino
    WS-C2950T-24 starting...
    Base ethernet MAC Address: 00:06:52:bb:c9:40
    Xmodem file system is available.
    The system has been interrupted prior to initializing the
    flash filesystem.  The following commands will initialize
    the flash filesystem, and finish loading the operating
    system software:
        flash_init
        load_helper
        boot
    switch: flash_init
    Initializing Flash...
    flashfs[0]: 4 files, 2 directories
    flashfs[0]: 0 orphaned files, 0 orphaned directories
    flashfs[0]: Total bytes: 7741440
    flashfs[0]: Bytes used: 3726848
    flashfs[0]: Bytes available: 4014592
    flashfs[0]: flashfs fsck took 7 seconds.
    ...done initializing flash.
    Boot Sector Filesystem (bs:) installed, fsid: 3
    Parameter Block Filesystem (pb:) installed, fsid: 4
    õíííííí   <---These characters appear no matter what keys I hit.

    Hi mattymattlynch
    Check the workaround on the following documents:
    http://www.cisco.com/c/en/us/support/docs/switches/catalyst-2950-series-switches/41845-192.html
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst2950/software/release/12-1_22_ea11x/configuration/guide/scg/swtrbl.html
    If no luck , the flash might be corrupted and requires a replacement.
    Hope this helps
    -Randy-

  • Does OVM 3 support network I/O management and storage I/O prioritization

    Does OVM 3 support any QoS setting for networking and/or storage? If so how are they set? I have been looking and can't seem to locate these settings.
    In OVM 2.2 network I/O traffic management and storage I/O prioritization could be set as described in this 2.2 blog posting.
    http://blogs.oracle.com/virtualization/entry/oracle_vm_22_new_feature_cpu_s
    Thanks

    It is not manageable through the GUI but can be changed in the vm.cfg file. Example:
    vif_other_config = [['00:16:3e:31:d5:4b', 'tbf', 'rate=8mbit,latency=50ms'], ['00:16:3e:52:c4:03', 'tbf', 'rate=10mbit']]
    - ingress
    vif = ['mac=00:16:3e:31:d5:4b,bridge=xenbr0,rate=10Mb/s@50ms'] - egress