Does labview have a 2D FP high/low pass filter?

After digging through labview for quite a while, and then trying Google I'm starting to think there really is no floating point filter functions in labview for 2D arrays?  I tried the IMAQ kit, but even after all the frustration involved in actually getting an array into an "image" it doesn't seem to support floating point (at least as far as I can tell).  
Am I missing something or does this really not exist in labview?

Hi, Am not sure whether i understood your question. what does this floating point filter functions means? Have a look that attachment. Different kinds of filters are there in LabVIEW and it accepts floating point input. If you want to pass 2D input pass it thru for loop.
Hope this helps you.
Attachments:
f1.JPG ‏137 KB
f2.JPG ‏150 KB

Similar Messages

  • Decimation( Does decimation.vi have a low pass filter?)

    Hello,
        I have a question regarding decimation function (decimation(continuous).vi) in labview. Does it have a low pass filter to take care of aliasing, if yes is it a zero phase filter. Basically I am looking for some thing which can decimate 20KHz sampled signals to 5KHz.
    Thanks,
    kartik
    Solved!
    Go to Solution.

    Depends on your LabVIEW version and installed toolkits. 
    The Digital Filter Design Toolkit  has a decimation VI that includes a LP AA filter.  Open the LabVIEW Help and search for 'decimation' and 'filter' to see what tools are available.
    Using LabVIEW: 7.1.1, 8.5.1 & 2013

  • Does scc sg04 have low pass filter?

    Hi.. I am using SCC-SG04 for full bridge strain gauge with SC2345. I found the voltage output on oscilloscope with much noises when I directly measured from SCB 68 output which linked with SC2345.
    High frequency noises was reduced a lot when I used simple passive RC low pass filter circuit. (cutoff freq is 1kHz) But there are still noises. Voltage excitation 2.5V and gauge resistor values are 120 ohms.
    Therefore, I wish that is there any filter in SCC SG04? I found that  manual described it has 1.6kHz LP filter. Actually I am not sure what my cutoff freq should be and I think there should be less noise if SCC SG04 has LP filter. Am I right?
    I would like to use DAQ in PC and I don't know which suitable hardware to use. I already have Labview 8.
    Please reply me.
    Thanks.
    Myo

    Hello myo,
    First off, welcome to the NI forum.  To answer your question, yes there
    is a 1.6kHz RC low pass filter on the SCC-SG04 module.  I am unsure why
    you are getting noise when you measure the signal directly, however there are several possibilities.  The most likely of which is since the
    device is not attached to a DAQ card (as it usually is), there may be
    some grounding issues, the device may not be powered correctly, or some
    other issue related to connecting the devices together.
    The type of DAQ cards we usually reccomend for use with the SC 2345 are our E series or M series cards. You can use the SCC Advisor to help you choose as well. If you already have some HW, just choose what you have; It will be included in a quote, but you can use the advisor to see which HW works with the rest of your setup.  Some of these cards have hardware filters as well, and you may be able to do some filtering in software.
    If you are looking to purchase a DAQ card for your computer, I suggest calling or emailing our sales department, especially if you want more information about the different cards we offer.
    Neal M.Applications Engineering       National Instruments        www.ni.com/support

  • Does LabVIEW have any kind of source control?

    I want to use a source control tool such as git and svn.
    Does LabVIEW have such a tool?

    Hi icat,
                Yes.See these: (Sorry as GerdW pointed out not embedded in.)
                https://decibel.ni.com/content/docs/DOC-1681
                http://zone.ni.com/reference/en-XX/help/371361D-01/lvhowto/configuring_scc/
    Thanks as kudos only

  • Does Labview have Try Catch exception handling?

    1) Does Labview have Try Catch functions, exception handling?
    2) Can Labview access a file or download a file using http or https?
    3) How can labview  read data from an ex ternal server http or https?
    This is in labview 2009 or 2011

    Hi E,
             1. you can chain together your VIs with the error wires, such that if an error occurs in one of them, none of the following VIs will execute.  That's  like throwing an exception - it interrupts the execution chain.  You then "catch" that exception by putting an error handler wherever necessary, but not necessarily in every single VI.Hope  You wouldn't put try..catch inside every single .NET function, instead you handle the exception at the level at which is most appropriate. Same thing can be done in LabVIEW.
    Also see this.
    2. The attached example downloads a picture with http "GET" command.
        Dilbert.Main_LV71.vi 160 KB
    3.see this thread:
       http://forums.ni.com/t5/LabVIEW/Read-a-text-file-from-Labview-web-server-http/td-p/267434
    Yes!!The same thing pointed out by nijims.
    Thanks as kudos only

  • Does LabVIEW have support for entering Urdu language script?

    Hi All!
    My LabVIEW application requires users to enter their observations in a string control which is then stored in an excel file.
    Now the issue is that the user wants to enter the data in Urdu language.
    Now my question is, Does LabVIEW have support for entering Urdu language script in a string control?
    If yes how can I implement this? If no, is there any possibility that National Instruments could extend some help in this regard upon request?
    Regards,
    Reeves

    My experience from Hebrew, which is also right to left, is that it can be done if the operating system supports it, but it will work badly if you include anything in the text which is not an Urdu letter. This causes it to be displayed in the wrong side of the control and is only solved if you add more Urdu text after it.
    One option you can try is including an ActiveX control (such as the rich text box) for editing the text and then you can probably get the text from it using a property. I don't remember trying it (my users don't usually need to input Hebrew text themselves), but I think it should work. I wouldn't have any hopes for NI doing anything about this, because it's considered to be a relatively small market.
    Try to take over the world!

  • Low pass filter in LabVIEW Base Development System

    Hello,
    I've got a problem for several days and I haven't find even a hint to fix it so it's driving me crazy.
    I'm developing an application on LabVIEW Base Development System for automatical aquisition and exploitation of five signals.
    These signals are generated by a deformation gauge and four potentiometers linked to a NI USB 6210.
    I'm using the DAQ assistant on LabVIEW to get and use these signals.
    My problem is that I need a 2nd order low pass filter on the deformation gauge signal to get something I can use afterward and none is include in the Base development Sytem of LabVIEW.
    I'm sure there is a way to pass through this without buying the Full Development version but I haven't found it yet.
    Does anybody has already had this problem and succeed in fixing it ?
    If yes, can I have the code ?
    Thanks

    Thanks for your responses.
    I've tried to create a subVI using the transfer function of the filter I need.
    Here is the diagram of this subVI :
    I'm not sure of this transfer function at all. It seems too simple to me.
    Does it look weird to you or does a low-pass second order filter can have such a simple transfer function ?
    I've tried it and my signal is still unstable. I guess I'm doing something wrong, but as I'm not that good in electronics, I can't figure out what.
    Thanks again

  • What does the Low-Pass filter do (for dummies)

    Dear colleagues,
    I'm about to encode a lot of content for DVD using Apple Compressor Vers 3.5.2. This project calls for 2.0 Stereo as well as 5.1 surround. I am wondering if I should check or un-check the Low-Pass Filter for the Full Bandwidth Channels for the 2.0 stereo track.
    Same question for the 5.1...
    In case it's important to note, the LFE track of the 5.1 mix has low frequency effects only and nothing else.
    The explanation in the manual seems confusing to me. Would someone be kind enough to help me determine the correct setting?
    Thanks in advance!
    Xavier

    Hi David,
    Thanks for your reply. I think I'll just turn OFF this filter for both my 2.0 Stereo and 5.1 Surround tracks.
    In the name of proper communication however something still doesn't make sense. The compressor manual states the following:
    Full Bandwidth Channels
    Apply Low-Pass Filter: Select this checkbox to turn on a low-pass filter with a cutoff near the available audio bandwidth that is applied to the main input channels. If the digital signal fed to the main input channels does not contain information above the available audio bandwidth, you can turn off this filter. Compressor will automatically determine the available bandwidth.
    Question 1: What/which is the available audio bandwidth?
    Question 2: Why would anyone want to apply a Low-Pass filter to a FULL bandwidth channel? I would think that since these are FULL bandwidth channels you would want to maintain the full range of frequencies. No?

  • Missing High-low Pass Effect/Filter

    The high-low pass audio filter, Bass & treble and some others are missing from my adobe after effects cs6. where are they ? how do i get them?

    Reinstall the program. Do so with sufficient user privileges and file permissions. Also turn off security tools. Same when running the program.
    Mylenium

  • How can I stop my lock-in results from oscillating. The low pass filter is creating artificial noise

    I am using the lock in amplifier kit and sort of sending some of the parameters manually. I choose manually the low pass filter.
    Now I find strange behavior depending on the filter I choose. 
    The lock in results oscillates in time, the higher the dB roll off the longer it seems to take to stabilize. Also the frequency of the oscillations becomes lower. This I don't find too weird, the problem is that it just won't stop. 
    If I use a small time constant and there is no real change in my signal I can easily follow the shape of the the oscillations. 
    If I use a larte time constant it seems there is an average over the oscillation and then it looks as if it was noise. 
    All the time my signal has not changed one bit. 
    This is very anoying since it produces about 20-300microV of noise. (peak to peak amplitude of the oscillations) 
    So far I've gotten the best results with the IIR (5dig) with 40dB roll off and order 1
    Does anyone have an idea of what to do?

    Hi BlankaFlux,
    could you maybe provide us with a more specific example? What kinds of filters have you tried?
    For information on advanced digital filter use, please see the following pages:
    - Working with LabVIEW Filtering VIs and the LabVIEW Digital Filter Design Toolkit VIs
    - Digital Filter
    Maybe you could look into trying the NI LabVIEW Digital Filter Design Toolkit
    Happy holidays!
    Peter
    Peter A.
    Field Sales Engineer, NI Germany

  • Scxi 1120 low pass filter specs for anti aliasing

    Hia,
    I'm am currently finnishing the development of a multi channel spectral analysis unit and I am concerned about aliasing. I have observed that the 1120 isolation amplifiers that I am using have a two position low pass filter for 4Hz and 10kHz now my problem is this, I'm sampling at 25600Hz and thus need to attenuate the signals by 12800, as i am using a 16bit AD card to be able to maximise its resolution I need to attenuate the signals to -92 dB  (or -96 dB  I can't remember which one) by this frequency.
    does anyone have details of the 1120's 10kHz filter? can I get away with using this or do I need to use a speciallist anti aliasing filter (which wouldn't be as tough a filter as I am only interested in signals up to 5kHz so I could have a much slower roll off)\
    Cheers
    Any help would be appreciated
    90% of all experts aggree that 1 out of 10 experts are wrong

    The specific characteristics of the SCXI-1120 are not available because the filter is not high-performance since it is designed speicifically for noise rejection. From the SCXI-1120 user's manual (http://www.ni.com/pdf/manuals/320425d.pdf), you can see that there are two lowpass filter stages, and then there is also a bandwidth limitation imposed by the amplifiers. The two filter stages are simple RC filters, so I would doubt that the roll-off is steep enough to reach -92dB attenuation at 12.8kHz. I would recommend either designing your own first stage filter, like you had mentioned, or find a way to increase your sample rate.
    -Logan

  • Low pass filter of DAQ USB 6255

    Hi there
    I am using USB 6255 data acquisition board. The cutoff frequency of the internal low pass filter is 1.7 MHz, therefore, the background noise with frequencies below 1.7 MHz cannot be eliminated. The multiple channel signals I am measuring have 10 KHz frequency and the amplitude from 2 mV to 20 mV, but the accurate measurement cannot be achieved even I set the AI measurement range is 100 mV. Could you please guide me to add a extra analogue or digital low pass filter and keep the fast response time if possible? Thank you.
    Regards
    Jiabin

    Hi Jiabin,
    Are you using LabVIEW to record your acquisition? If so you can use our 'Filter express vi' to achieve this. The configuration window is shown below:
    Let me know if this helps,
    John McLaughlin
    Insides Sales Engineer Team Leader
    National Instruments UK & Ireland

  • Low pass filter (PXI 4472)

    Hi,
    I would like to know whether the PXI4472 module has a built-in low pass filter ?? If yes, can you send me the specfication for that filter?? Also, does the the SCXI 1125 support Vrms = 2500V isolation ??

    Hello,
    The PXI-4472 has a antialias filter which limits the bandwidth of the signal it can represent. The SCXI-1125 has +-300 Vrms of working isolation per channel. The information regarding the PXI-4472 filters and the SCXI isolation specifications may be found at NI Product Manuals.
    Let me know if you have any further questions. For direct questions regarding the PXI-4472, you will be better off posting a new question to the DSA discussion forum.
    Best Regards,
    Jared A

  • Low Pass Filter Counter Input Compact DAQ

    Hello,
    I need to put a 10kHz Low pass filter on a counter input.
    I have a CDAQ 9178
    and a 9421 Digital Input module
    Acording to the documentation and my own experience I can't enable the filter on the Digital input card.
    Is there another way to do this?  I need to filter the signal in hardware.
    Thanks
    Dan

    Your filter might work, however it is build to filter power lines, with current rating 6A and powerline voltage. You pay a lot for a box with screw terminals and a lot of copper and high rated capacitors.
    Have you tried a simple RC lowpass (costs less than 50 cent, even when purchased in a pharmacy ) ? R=1500Ohm, C=10nF gives a coarse 10kHz first order lowpass. The C fits between the ground and input terminals of your DAQ, the R in the signal line to the input.
    Output impedance of your source?
    If you explain more of your application, type of signal, we might find other solutions.
    Greetings from Germany
    Henrik
    LV since v3.1
    “ground” is a convenient fantasy
    '˙˙˙˙uıɐƃɐ lɐıp puɐ °06 ǝuoɥd ɹnoʎ uɹnʇ ǝsɐǝld 'ʎɹɐuıƃɐɯı sı pǝlɐıp ǝʌɐɥ noʎ ɹǝqɯnu ǝɥʇ'

  • Low pass filter with formula node

    Hi guys.
    My teacher gave me an exercise (attached) in which i have to realize a low pass filter with the formula node. He gave me also the input/output but I  have no idea where to start.
    Can you help me?
    Attachments:
    Exercise6.vi ‏10 KB

    Check out this thread:http://forums.ni.com/t5/LabVIEW/Butterworth-Filter/m-p/2496680
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

Maybe you are looking for

  • Does the new Mac Pro Server have lights out management?

    I would like to know if the Mac Pro Server has the LOM. Such as the ability to turn off, on, and reboot by simply using the server admin tools. I use this feture very often with my current xserve and would rather buy a new server then try and find a

  • Customer Master Data interface to external using Seeburger on MDMP

    Hi Experts,    Currently, customer master data is interfaced to external system via IDOC. The middleware used is Seeburger.    If the system is changed to MDMP, would there be any impact to this interface?    Is Seeburger communicates in Unicode? If

  • Window Tabs

    This issue has probably been dealt with several times before in this forum, but I have a question about tabbed windows. I have Safari set to open new links as tabs. However it doesn't always work that way. Sometimes a link creates a whole new window.

  • Changing Document Template Programatically

    My requirement is that after a certain step in a workflow the document will be send to another library and an MS Office watermark will be inserted automatically to the document. What I am trying as one of the solution to create a similar content type

  • I would like to erase my ipod touch and then resync it with my existing itunes library, is this possible?

    I have a ipod touch that has a different library on it from an old (no longer usable) computer. I have another itunes library on my laptop that is very similiar but not exactly the same as the one on the ipod. Can I erase the ipod and sync it to the