Doubt on Field only exit in RSA6 ?
Hi,
I have added few fields from the comm structure to the extract structure for 2lis_02_scl datasource (from right to left). So those fields should be checked or unchecked in field only exit in RSA6. Can you please suggest. Currently those are checked, should I uncheck those.
Thanks
Hi Arminder Singh,
Thanks for the reply. I have 2 doubts on the same, can you please provide your thoughts.
1) How to determine to add any compatible field to the extract structure ( that is moving from comms truc from right to left) whether its delta capable or not and if its working or not. Becasue even after adding the fields to extract struc and activating the ds and then remove unhide etc., the values are not populated in that field when i check in rsa3, where as the values are existing in the standard table,
for ex, it says mcremng and i have moved from left to rite...remove hide and remove field avlble in exit and still the values are not coming in the newly moved field. the ds is active and everything is fine.
Am i doing something wrong ? Can anyone tell me if there is anyway to check if any field moved from comm to extrac struc may not work even after doing the maintain options, activate ds ,generate, unhide etc. How to check if a particlue standard field which was delivered by sap may not work even after adding it to the extract struc and how to analyze that ?
Hope I am clear what I am saying here.
Thanks for your time,
Similar Messages
-
Use of selection, inversion & field only tabs in datasource
Hi,
What is the use of the tab
selection, inversion & field only know in customer exit
in datasource.
Also is there any other use of hide tab except unhiding it to reflect in BI system.
Thanks,
Shamkant.Got on own
-
What is meant by Selection, Hide,Inversion and Field only during Datasource
Dear Mates,
During Datasource Generation in LO extraction , I can see the tabs
Slection
Hidefield
Inversion
Fild only.
Can any on please explain me elobarately each of them.
Thanks,
SudhaIf you do a F1 on each you'll have a description, but here is a summary:
Selection: You want to be able to select a value in this characteristic through the infopackage
Hide: You don't want to be able to see this field.
Inversion: For a key figure, change sign. 1 becomes -1 and vice versa.
Field Only: Field is available only for user exits and such but is not extracted.
Hope this helps. -
Selection, Hide, Inversion, Field only
Hi All,
Give me clarity on Selection,Hide,Invesion,Field only on customer exit. When we use these check boxes? Give me detailed of information on that.
1)Selection.
2)Hide
3)Invesion
4)Field only on customer exit.
Regards,
Shwetha Reddy.hi,
1.Selection of a Field of a DataSource
Selection field for a DataSource
Use
Set this indicator to use a field from the DataSource as the selection field in the Scheduler for BW.
Due to the properties of the DataSource, not every field can be used as a selection field. In this case, the property is not changeable.
2. Hide Extract Structure Field
Use
To exclude a field in the extraction structure from the data transfer, set this flag. The field is then no longer available in BW for determining transfer rules and therefore cannot be used for generating transfer structures.
3. inversion
Field Inverted When Cancelled (*-1)
The field is inverted in the case of reverse posting. This means that it is multiplied by (-1). For this, the extractor has to support a delta record transfer process, in which the reverse posting is identified as such.
If the option Field recognized only in Customer Exit is chosen for the field, this field is not inverted. You cannot activate or deactivate inversion if this option is set.
4. field only
Flag Relevant RNOTECREL
The indicator Field known only in Exit is set for the fields in an append structure, meaning that by default, these fields are not passed to the extractor in the field list and the selection table.
Procedure
Remove the Field known only in Exit indicator, to get the Service API to pass the field in the append structure to the extractor
hope this help you
regards
Harikrishna N -
Hello SDNers,
I would like to ask you in the datasource there are 2 option si would liek to know when are they used.
1) Inversion
2) Field Only
And Field only does this need to be checked when its custom enhancement t structure or can be checked for other reasons aswell.Please explain.
Thanks.
Krrish.Hi,
usually inversion feature is useful for DS carrying customized Keyfigures which has -ve sign
before loading to BW ,the value will be mulitplied by -1 and goes to BW
check this SAP note:
Inversion
Reverse postings are possible for customer-defined key figures. For this reason, inversion is only possible for certain transaction data DataSources. These include DataSources that have a field that is indicated as an inversion field, for example, the field update mode in the DataSource 0FI_AP_3. If this field has a value, then the data records are interpreted as reverse records in BW.
Set the Inversion indicator if you want to carry out a reverse posting for a customer-defined field (key figure). The value of the key figure is then transferred in inverted form (multiplied by 1) into BW.
filed only..
it is useful when you are enhancing the DS with the userdefined fields and has wriiten the code in CMOD
Sap note:
Field only known in exit
You can enhance data by extending the extract structure for a DataSource using fields in append structures.
The indicator Field only known in Exit is set for fields of an append structure. In other words, by default these fields are not passed onto the extractor from the field list and selection table.
Deselect the indicator Field Only Known in Exit to enable the Service API to pass on the append structure field to the extractor together with the fields of the delivered extract structures in the field list as well as in the selection table.
Cheers,
Swapna.G -
Hi Friends,
what is the use of field only check box iam littelebit confused, could you explain me clearly.
Thanks and Regards
Venkat.MarneniHi,
If you do enhancement for a datasource it will be used:
The indicator Field known only in Exit is set for the fields in an append structure, meaning that by default, these fields are not passed to the extractor in the field list and the selection table.
So by default it won't get data, so remove the tick mark and then do the mapping in BW.
Thanks
Reddy -
Not able to select Field only option
Dear All,
I created a generic datasource based on a infoset query and enhanced the extract structure with a component zzvalov (amount). The idea is to fetch the amount from a different table writinga n user exit.
Now, the filed ZZVALOV is by default in Hide mode in the extractor field selections. When I try to uncheck the Hidel field and select Field only option and save , I get an error message that OLTP has still some errors.
Can anyone help to overcome this error. Is it mandatory to have the exit in place before I uncheck the Hide filed and select Field only ioption ? I did not get any warnings while activating the extract structure as well.
Thanks in advance
Regards,
SrinivasHi Srinivas,
Please check:
['The OLTP Source still has errors|'The OLTP Source still has errors]
[Re: OLTP error when appending a data source .|Re: OLTP error when appending a data source .]
[Generic Datasource Error: The OLTP source still has errors|Generic Datasource Error: The OLTP source still has errors]
[Re: The OLTP source still has errors Message no. R8417|Re: The OLTP source still has errors Message no. R8417]
[Re: OLTP Contains still has errors.|Re: OLTP Contains still has errors.] -
Extractor: hide Vs field only selection
Hello BW experts,
in datasource properties field in the R/3; what is the difference between the fields 'hide' vs 'field only'.
suggestions appreciated.
Thanks,
BWerHi,
Hide field
You should set this indicator to exclude an extract structure field from the data transfer. As a result of your action, the field is no longer made available in BW when setting the transfer rules and generating the transfer structure.
if u dont want to see this this ..u set this field u cant see in the BW which is available in extrac structure
Field only known in exit
You can enhance data by extending the extract structure for a DataSource using fields in append structures.
The indicator Field only known in Exit is set for fields of an append structure. In other words, by default these fields are not passed onto the extractor from the field list and selection table.
Deselect the indicator Field Only Known in Exit to enable the Service API to pass on the append structure field to the extractor together with the fields of the delivered extract structures in the field list as well as in the selection table.
and also see this thread...
https://www.sdn.sap.com/irj/sdn/profile?userid=2515725
Assign Points if useful
-Shreya -
Expanding Text Fields, only when printed
All,
I have a dynamic form that has many text fields for user input. These fields have a fixed height, however allow multiple lines beyond the visible area. I don't want these text fields to expand when the field is exited, but rather when the form is printed. The form is set up neatly on 7 pages, and I'd like it continue to be 7 when the user is working, however I'd like it to expand to accomodate the extra text upon printing.
How can I make it so when I print, the fields expand and the data flows onto the next page(s)?
Thanks!
AaronThank you. I'll also have to make sure the subforms are set to "flowed" to make sure the expansion works appropriately, correct?
I can get everything to work correctly until my last page. When flowing the subform it compresses all of my fields and won't let me resize or move. Is there any easy way to resize a subform or adjust the locations of the fields within it? -
Crystal Report: Show Field only in Print-Preview
Dear Experts,
is it possible to show a field only in the print preview (when the report is generated) without printing this field?
Thanks for Help.
JacquelineNo, it is not possible to display a report object on screen then suppress it when printing.
Fuskie
Who thinks you would have to use 2 reports or use a parameter that offers the option of formatting for view versus for print... -
How to restrict AS02 access to certain fields only
How to restrict AS02 (Asset Master Record) access to certain fields only. Currently when you assigned AS02 to a certain user, this will enable the user to change all the fields in the asset master record. Suppose i want only the user to restrict the access to certain field eg.NDJAR (Life in Yrs).
Thanks for your inputs.
Regards,
Roberthello,
basis has to assign the proper activity with object A_S_ANLKL. in this case they have to allow activity 03 only with combination of Cocode,asset class. see some more details below.
This authorization object is the first part of the object "asset master record."
The definition at this level determines whether the user is authorized to process data in a given company code. The activity type for the transaction is also defined here. This authorization object is used for master data transactions, for the display of value fields, and for reporting.
Defined Fields
The following fields are assigned to the authorization object
Asset class (specified by entering a value in the pop-up window)
Company code (specified by entering a value in the pop-up window)
Activity type - there are three different activity types:
01 = Create
02 = Change (including blocking and deleting)
03 = Display -
Printing "Form Fields Only" not working correctly in Adobe XI
I have a pdf form with fields including check boxes. If I print this form with all fields it prints correctly, but if I select "Form Fields Only" then all check boxes print as checked regardless of whether or not they are checked. When I use this form in earlier versions of Adobe I do not get this problem. Any ideas or solutions?
Also the "PrintParams" properties require version 6 or above of Acrobat/Reader.
One has to review the Acrobat JavaScript API for all sorts of version variations in the way Acrobat's JS object works. And the documention is not always correct. -
Alv output to Excel with numeric fields as numeric fields only and not char
Hi,
When we download the alv output to excel format in the locat file using the toolbar button provided in the ALV, the numeric fields get converted to character format. Is there any other way or settings in ALV so that the numeric fields will be get saved as numeric fields only and not character?
Rgds,
MAdhuriany idea for above problem is welcome
-
How to print out fillable fields only
I'm a newb, help! I am trying to create a form in LiveCycle.
I have brought in a pdf, made some fillable fields. So far so good, here's where I'm struggling.
I want the recipient of the pdf to fill out the forms, (while still seeing the pdf in the background), BUT when they print, I want them to ONLY print out the information that they filled in the fillable fields.
So basically, they receive a document in Adobe Reader, it has a pdf in the background, and they fill in some fields, then they place a page in their printer to just print the fillable fields only.
Does anyone know if this is possible?"You can control the visibility of objects using the presence property"
Here is where I get confused. I understand that you can change the visibilty in this area, but I want the pdf background that is part of my form to be the area that doesn't print, so I can't understand how I highlight that particular area to switch it to "screen only" because it isn't really considering a text field or anything like that, it was just a pdf that I imported from the start and then built all my text fields on top of. -
I have a fillable form that is used by everyone in the office. When the fields are filled we print using the form fields only option to print on our invoices. When I go to print it in Acrobat XI standard using the form fields only option, none of the information I filled shows up or prints. No one else in the office has this problem. Does anyone know why I can't do this, but other people can?
I have a fillable form that is used by everyone in the office. When the fields are filled we print using the form fields only option to print on our invoices. When I go to print it in Acrobat XI standard using the form fields only option, none of the information I filled shows up or prints. No one else in the office has this problem. Does anyone know why I can't do this, but other people can?
Maybe you are looking for
-
Do I have spyware on my iMac?
I'm wondering if my computer has been infected with spyware. I had McAfee on my pc but no protection on my Mac as I was told Macs don't need it. I read about Clamxav on this site yesterday and installed it and scanned my hard drive but it didn't unco
-
Disk Utility Error Message-Bootable USB/ExternalHD
I'm using Disk Utility at the moment to create a bootable USB/External HD ( I've tried both ) and nothing is working. It comes up with a error message. I have the retail Snow Leopard DMG and i'm doing everything correct user wise. It's just something
-
How to change the interval real substance for DG-Filling
Hi, Im performing the filling process, to fill the dangerous goods master with data records from specification management. It seems that most data is transferred successfully. Although I receive the following error message in the import log. 1. What
-
Q: Auto file naming in TextEdit possible?
I've just come over from the 'Dark Side' having been freed from the 'MicroSith' Empire and I'm really enjoying my two new Macs. I'm taking some extra time to set it up like I want. I'm interested in productivity. Is there a way to cause TextEdit to t
-
How to access the MS access database through network
Hi friends, I want to read,write and some database functions through network.I hope it is possible. Steps i followed for network access 1. I created a database named magal using DB.create_mdb_link.vi in local pc 1. 2. I used DB Tools open connection