Duplex mismatch between N7k and 5508

Hi All,
I met a duplex mismatch issue in our new DC.
The port configuration on the N7k and controller is the same as in other DC
Only difference is version of the NxOS on the N7k.
On N7k 5.2(1) works
On N7k 5.2(7) i get below logs :
2013 Aug 21 22:23:24 xxx %CDP-4-DUPLEX_MISMATCH: Duplex mismatch discovered on Ethernet10/8, with LAGInterface0/3/1
2013 Aug 21 22:24:24 xxx last message repeated 8 times
2013 Aug 21 22:25:24 xxx last message repeated 8 times
2013 Aug 21 22:27:24 xxx last message repeated 16 times
2013 Aug 21 22:29:24 xxx last message repeated 16 times
Port configuration :
interface Ethernet10/8
  description WLC 5508-1
  switchport
  switchport mode trunk
  switchport trunk native vlan 50
  switchport trunk allowed vlan 50,500,570
  spanning-tree port type edge trunk
  channel-group 1100
  no shutdown
xxx# sh int e 10/8
Ethernet10/8 is up
Dedicated Interface
  Belongs to Po1100
  Hardware: 10/100/1000 Ethernet, address: 0006.f6b1.d2f7 (bia 0006.f6b1.d2f7)
  Description:WLC 5508-1
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
  reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA
  Port mode is trunk
  full-duplex, 1000 Mb/s
Controller 5508 version 7.3.112.0
Controller ports :
Port Summary
           STP   Admin   Physical   Physical   Link   Link
Pr  Type   Stat   Mode     Mode      Status   Status  Trap     POE    SFPType
1  Normal  Forw Enable  Auto       1000 Full  Up     Enable  N/A     1000BaseTX
2  Normal  Forw Enable  Auto       1000 Full  Up     Enable  N/A     1000BaseTX
3  Normal  Forw Enable  Auto       1000 Full  Up     Enable  N/A     1000BaseTX
4  Normal  Forw Enable  Auto       1000 Full  Up     Enable  N/A     1000BaseTX
How can i fix this issue ? Ports are set up and show the same - 1000 / Full
the messages are annoying as loggs are almost full of them.
Thank you in advance

Hi Matthew,
The issue is related to bug -> "CDP duplex mismatch when using LAG on 5508 & 8510 WLC” (CSCuc94082)
The fastest way to solve (workaround) this is disable cdp on the controller by executing following command:  config cdp advertise-v2 disable
Hope this helped you
Regards,
Radek

Similar Messages

  • Mismatch between availability and marker

    I have run the following command:
    /repvfy -detail -fix -pwd password
    and am seeing a section called "Mismatch between availabiltiy and marker". What does this mean? I know there is a bug out from Note: 735957 against 10.2.04 and that patch 6951116 is available. I also know this bug is fixed in 10.2.0.5. But I don't know what exactly this section is telling me. Here is the output I am seeing:
    6. Mismatches between availability and marker
    TARGET_GUID TARGET_NAME TARGET_TYPE MARKER_AVAIL_STATUS MARKER_TIME CURRENT_STATUS START_TIME
    9CB8EE19415C3C6B55954BF3346C1106 ssan-Internal Concurrent Manager oracle_apps_icm 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:22
    1B21AAEF5AC63DD44FE339B7852EA1EE ssan-Report Server_ssan_devstar2 oracle_apps_reports 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:13
    F5EAD749526EC1116A70157771E3D011 ssan-Oracle Workflow Agent Listener oracle_apps_wfalsnr 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:29
    CD32714673BC508CDBF85BF191A5A1B7 ssan-Workflow Background Engine oracle_apps_wfbg 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:26
    FADA1D6BF4DFD0E8AA1739A6666BA210 SSAN oracle_database 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:40
    0BE2ACE2EDC7271744DA1A249E30C9A5 APPS_ssan oracle_listener 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:12
    89D241EEEF24821E30AD66741BC3D433 devstar2.rtd-denver.com oracle_listener 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:20
    F40BAF501645A5957A498E7A270AEA47 ssan-Apps Listener_ssan_devstar2 oracle_listener 6 09-JUN-2009 10:41:50 1 28-MAY-2009 14:25:28
    8 rows selected.

    Various provision like Freight, transport etc .
    these should go to separate GL accounts. if you give wrong account assignment value will be passed to GRIR. then difference will happen
    sunoj

  • WLC mobility group between 4404 and 5508 controllers

    Mobility 'Control and Data Path Down' between 4404 and 5508 WLC's.
    Hello, we have 5 x 4404 WLC's running 7.0.240.0 with mobility configured fine between them.
    We have installed a 5508 with HA running 7.4.110.0, and have tried to add it to the mobility group, however we see 'Control and Data Path Down' between the new 5508 and all the 4404 controllers.
    All controllers have:
    The same virtual address
    Management interfaces are in the same VLAN, and indeed all the controllers connect via the same pair of 3750X stacked switches.
    The default mobility domain name is the same
    4404 output when issung the command 'show mobility summary'
    Symmetric Mobility Tunneling (current) .......... Enabled
    Symmetric Mobility Tunneling (after reboot) ..... Enabled
    Mobility Protocol Port........................... 16666
    Default Mobility Domain.......................... SGH-Mobility
    Multicast Mode .................................. Disabled
    Mobility Domain ID for 802.11r................... 0xe209
    Mobility Keepalive Interval...................... 10
    Mobility Keepalive Count......................... 3
    Mobility Group Members Configured................ 6
    Mobility Control Message DSCP Value.............. 0
    5508 ouput when issueing the command 'show mobility summary'
    Mobility Architecture ........................... Flat
    Mobility Protocol Port........................... 16666
    Default Mobility Domain.......................... SGH-Mobility
    Multicast Mode .................................. Disabled
    Mobility Domain ID for 802.11r................... 0xe209
    Mobility Keepalive Interval...................... 10
    Mobility Keepalive Count......................... 3
    Mobility Group Members Configured................ 6
    Mobility Control Message DSCP Value.............. 0
    I've spent quite some time double checking all the configurations to no avail.
    Has anybody seen this problem before?
    Kind regards
    Dave Bell

    Thanks Sandeep.
    I am well versed with WLC's and mobility, however trying to add a 5508 to a mobility group with 4404's has come up with a bit of a curve ball.
    All the 4404 controllers all joined the mobility group fine, no problems at all - its only the 5508 I am struggling with.
    In theory its simple, populate the IP address, and MAC addres of the management interface of the remote WLC, as long as the management interfaces are in the same VLAN, and the Default Mobility Domain Name are the same it should come up.
    Interestingly I have found the 5508 reports its own management interface MAC address incorrectly when viewing the Mobility Groups:
    For example:
    {Screen shot WLC1.jpg}
    5508 management address is 10.95.x.x and when viewing the Mobility Management screen it shows its own MAC address as bc:16:65:f9:37:60.
    however!
    From our router is I do an sh arp | i 10.95.x.x (controller management address), I see:f872.eaee.becf.
    {Screen shot wlc2.jpg}
    Hence the WLC reports as: bc:16:65:f9:37:60
    and
    The network reports as: f872.eaee.becf for the same IP address.
    I have changed the other WLC's to the MAC adress seen on the network for the new controller, aka changed from
    bc:16:65:f9:37:60
    to
    f8:72:ea:ee:be:cf
    I now see the controllers reporting the mobility with the new controller as 'Control Path Down', however I am at a loss as to what may be causing this?
    Kind regards
    Dave Bell

  • Mismatch between sound and video

    When I watch a movie in iTunes of Apple TV (2gen) and I want to move it few seconds/ minutes and more backwards then it like "losing its mind",
    the video jumps forward (a lot forward) and the sound stays the same, so ther is mismatchment between sound and video.
    What can i do to solve this problem?
    Thank you!

    Am I the only one suffering this issue with the video transcoding?

  • Color mismatch between CS4 and Canon PIXMA PRO6500

    Hi there! I am trying to research if anyone else is having a problem with color mismatch between CS4 and their printer. Last night I printed a .tiff image out of CS4 to my Canon PRO6500 printer and the sky came out purple / pink! It was supposed to be a stormy grey color. I have the color management turned off on the printer settings. I have CS4 manages color turned on and the correct ICC profile selected for the paper I am using. When I do a soft proof in CS4 the image looks fine, but when I print I get something completely different, mostly with the sky (purple / pink) color! Just for the heck of it I did a Print Preview under my Page Setup and guess what, the sky actually shows purple / pink! So I have no idea what's going on. I checked all my setting, ink cartridges, tried different paper with the appropriate ICC profile and no dice. Still have a goofy looking sky! I thought PROOFING the image is supposed to show you how the printed image is going to look? apparently it doesn't because it's not. The Print Preview has an accurate representation of the print but I have no idea where the pink / purple sky is coming from. They are supposed to be stormy clouds as I said. I appreciate any help anyone can provide .
    Sabciu

    I have the color management turned off on the printer settings.
    But do you have a measured color profile based on a sample print? Most likely not, so this is not doing anything in your favor. The current profile may present the defaults for a given printer, but not the actual density based on your other printer settings. So by all means, unless you can be sure to obey a full calibration throughout, turn on the printer CM. Also, since it is a Pro model, you may actualyl have to use the dedicated RIP software that was bundled with it to get correct results, not the default windows print engine.
    Mylenium

  • Config mismatch between VSM and VPath - CSCum76142 bug

    Hi all,
    I got the error message "Config mismatch between VSM and VPath" on my Nexus VSM but I could not see any detail regarding this bug ID due to permission issue. Has anyone else got access to see this bug detail and able to share? I need to know if this bug is critical or just cosmetic. Thanks 
    regards,
    Robin

    Hi Robin,
    This DDTS was Junked. But here's the workaround that is mentioned:
    1. Deleting the vservice config (no vservice) & reconfiguring vservice, will get rid of this mismatch issue.
    2. Toggling the port-profile should also work.
    I see couple of other DDTS as well related to this and i would suggest to ask this question in "Other  Data Center Subjects" forum for detailed and quick answer.
    CSCtz36835 :Config mismatch on VSM and Vpath after deleting service vlan
    Regards,
    Kanwal
    Note: Please mark answers if they are helpful.

  • Contrast mismatch between Organizer and Editor

    I can edit an image in Editor to where it looks great, to include the contrast, brightness, shadows, etc.  When I send it back to the Organizer, it look much too contrasty and dark.  When I use the same images in a slideshow originating in Organizer, they still look too contrasty.  Is there a way to correct this?  I'm using PSE 10 on a Windows 7 -64 bit machine. Thanks for any ideas.

    Thanks for your quick response.  I just checked out the settings in both the Editor and Organizer and they're both set on "let me decide".  I'm not sure what to do on that one.  I could go with optimizing the computer screen with sRGB, or the Adobe RGB for the printer, or no management, or decide on the fly.  If I go with the computer, I guess I'd have to change it when I print a photo out, and vice versa.  Have any suggestions for me? Thanks again. 
    New update.  I have a Dell color laser printer, and I just checked the manual.  It offers both sRGB and AdobeRGB.  My priority is really to have a good printout.   If I check sRGB I should be safe for either print or computer, but I'm wondering if I'd get as good a printout with sRGB as with AdobeRGB.  The easiest might be to see what the printer is curently set on, and then set PSE Organizer and Editor to match it.  I'll do that, and then see if that helps the mismatch between Organizer and Editor. 

  • Data mismatch between 10g and 11g.

    Hi
    We recently upgraded OBIEE to 11.1.1.6.0 from 10.1.3.4.0. While testing we found data mismatch between 10g and 11g in-case of few reports which are including a front end calculated column with division included in it, say for example ("- Paycheck"."Earnings" / COUNT(DISTINCT "- Pay"."Check Date")) / 25.
    The data is matching for the below scenarios.
    1) When the column is removed from both 10g and 11g.
    2) When the aggregation rule is set to either "Sum or Count" in both 10g and 11g.
    It would be very helpful and greatly appreciated if any workaround/pointers to solve this issue is provided.
    Thanks

    jfedynic wrote:
    The 10g and 11.1.0.7 Databases are currently set to AL32UTF8.
    In each database there is a VARCHAR2 field used to store data, but not specifically AL32UTF8 data but encrypted data.
    Using the 10g Client to connect to either the 10g database or 11g database it works fine.
    Using the 11.1.0.7 Client to go against either the 10g or 11g database and it produces the error: ORA-29275: partial multibyte character
    What has changed?
    Was it considered a Bug in 10g because it allowed this behavior and now 11g is operating correctly?
    29275, 00000, "partial multibyte character"
    // *Cause:  The requested read operation could not complete because a partial
    //          multibyte character was found at the end of the input.
    // *Action: Ensure that the complete multibyte character is sent from the
    //          remote server and retry the operation. Or read the partial
    //          multibyte character as RAW.It appears to me a bug got fixed.

  • LACP suspended between N7K and N2K

    Hi
    we have a creation trouble between N7K and N2K on port-channel, the port-channel is suspended because LACP receive PDUs

    With FEX you use don't use the mode active. 
    Interface eth5/33
      switchport mode fex-fabric
      channel-group 70
    The FEX uses a "Fabric" header on the link, and doesn't require LACP.  You can use LACP on any host ports on the FEX, just not on the fabric links.

  • Data mismatch between TABLE and Std. Extract str. (AFPO & 2LIS_04_P_MATNR)

    Hi,
    I am getting data mismatch in ECC standard table and ECC standard extract structure. Please help me.
    I am using 2LIS_04_P_P_MATNR data source (standard extract structure).
    <b>I have following data in ECC Table (AFPO - Order Item).</b>
    AUFNR (Order Number) --> 4000460
    PGMNG (Total planned quantity)  --> 0
    PSMNG (ORDER QTY) --> 2000
    <b>Extract Structure is showing following data.</b>
    AUFNR (Order Number) --> 4000460
    PGMNG (Total planned quantity)  --> 2000 (It should be zero)
    PSMNG (ORDER QTY) --> 2000
    I have checked with many other order numbers. <b>The extract structure in RSA3 is showing correct values only if PGMNG is non-zero values. If PGMNG is zero, then it is automatically assigning PSMNG value.</b>
    Is this common? I want to display correct values for PGMNG from AFPO Table. Why this mismatch between table data and extract data. I have done  all required steps refreshing data (deleting setup tables, filling set up tables etc.).
    pls suggest. Poinsts will be assigned to every useful answer.
    Thanks in advance.

    Hi Avneet,
    I have a similar problem where in AFPO shows value 1000 in PSMNG field and 1200 in RSA3 for extractor 2LIS_04_P_MATNR.
    I have found that the standard feature of the extractor extracts the data at the time of release of process order. If the process order is changed after the release then the extractor will not picup the chagne.
    Ex: AFPO value 1000 ---BI Value 1000
    Now released in ECC
    AFPO value 1000 ---BI Value 1000
    In ECC value changed to 1500 after the release. BI will not pickup the change.
    Extractor is pulling the data from MCAFPOV table. You can check the values, there it matches with RSA3 values.
    I was just going thru forums for the solution. After i found the solution. I am just updating it.
    Hope it helps you.
    Thaks
    Srikanth

  • DataSource / Structures mismatched between Dev and Test Systems. ..!!

    Hi,
    We are doing a scenario. Where XI will update the data into PSA through ABAP proxy.
    Scenario worked perfectly in development system.
    We transported the objects from Dev to test. The Strucures are mismatched in SE11 between development and Test systems as below.
    Data sources (ZDS_RECIHDR and ZDS_RECTPALL) looks ok. But when I saw the structures in SE11 they are not correct, they got mismatched.
    Development:
    /BIC/CQZDS_REC00001000 - Header (ZDS_RECIHDR)
    /BIC/CQZDS_REC00003000 - Allocation (ZDS_RECTPALL)
    Test:
    /BIC/CQZDS_REC00001000 - Allocation (ZDS_RECTPALL)
    /BIC/CQZDS_REC00003000 - Header (ZDS_RECIHDR)
    Kindly let me know where it might have gone wrong?
    Thanks
    Deepthi

    We done it already. Still it is failing.
    While transporting, it is failing and showing the error as
    Program ZPI_CL_IA_PAYMENT_ALLOCATION1=CP, Include ZPI_CL_IA_PAYMENT_ALLOCATION1=CM001: Syntax error in line 000016
    The data object 'L_S_DATA' has no component called'/BIC/ZSALENUM', but there is a component called
    Program ZPI_CL_IA_PAYMENT_HEADER======CP, Include ZPI_CL_IA_PAYMENT_HEADER======CM001: Syntax error in line 000016
    The data object 'L_S_DATA' has no component called'/BIC/ZTRANDATE', but there are the following com
    The Structure is mismatched in SE11 between header and allocation structures. That is the reason it is failing.
    Any more ideas pls?

  • Timing mismatch between picture and sound.

    I have been using Premier Element ver. 12 with my films recorded with my Canon EOS camera without any problems. I have now been trying to clip a film recorded with a MAC copmuter. The files have .mov extension. My problem now is, that the sound and the pictures are not sycnroniced anymore. It seems that the Pictures are 3 seconds faster per minute than the sound. So after 20 minutes the Pictures are 1 minute in front of the sound. Playing the original files with the Windows player Works fine and the timing of the sound in Premiere Elements fits with sound using the Windows player.
    Any Ideas????
    Gert Munch

    Hi' ATR
    Ref. #8
    Loading one of the problem files into Movie Maker Shows a small but constant shift between sound and Video within Movie Maker. Easy to fix. Exporting and import into Premiere Elements shows the same small but constant misallignment. That is good.
    The screenshots of the required readings is seen below
    Properties from Premiere Elements:
    I did not dare to install the MediaInfo properties readout program as I was warned about malware.
    Ref. #9
    From Movie Maker the Video bitrate is stated to be:
    15-12-14: 177232 kbps
    12-01-15: 81164   kbps
    16-02-15: 177396 kbps
    10-03-15: 280596 kbps
    From the above screen shots the audio bitrate seems to be 128 kbps
    Hope this makes sense to you.
    Gert

  • PPDS production order dates mismatch between APO and R3

    Hi Friends,
    We are facing one problem regarding production order date mish match between R3 and APO systems specific to a product.
    The product is planned in PPDS and the order automatically transfer to R3 through online CIF.
    PPM has got two operations 0010 and 0020 and activity relationships are like this:
    P(0010) - P(0020) Start - Start relation ship
    S(0010) - P(0010) End - Start relationship.
    In PPDS dates are shown as :
    on operation 0010 the start/end  dates are shown as  08.15.09 to 08.22.09
    on operation 0020 the start/end  dates are shown as 08.15.09 to 08.22.09
    Overall order start date is  08.15.09
    Overall order finish date is 08.22.09
    and in R3 dates are shown as:
    on operation 0010 the start/end  date are shown as  08.15.09 to 08.22.09
    on operation 0020 the start/end dates are shown as 08.22.09 to 08.29.09
    Overall order start date is  08.15.09
    Overall order finish date is 08.29.09
    The order is off one week (APO vs R3) with start and finish dates.  
    if we change DS Board settings to ignore internal relationships manually then the dates are matching exactly in APO and R3.
    We want the production order dates to be matched without manual intervention.
    Could some one please provide some hints on what is happening here and how to correct it.
    Thanks.
    Krish

    Hi Friends,
    Thanks a lot for your valuable replies in this regard.
    Actually this problem is in production environment and it took some time to test the problem with the master data modifications
    you suggested.
    As DB and Siddhrath mentioned, the problem was with routing definition. There is no parallel sequence maintained in the routing but there is start-start relation maintained in APO PPM.
    We corrected the routing definition and checked the order dates. Now the dates  are matching in R3 and APO.
    I am awarding DB and Siddharth each five points in this regard.
    Once again thank you all for your time and valuable replies.
    -Regards
    Krish.

  • Data mismatch between dashboard and bw report

    Hi expert,
    Data is mismatchin between dashboard and BW report of .I am using SAP BW connection ,
    Dashboard screen shot
    BW Query output
    What is the issue can you please suggest...

    Hi Ganapathy,
    Please check the Prompt filter and Variables which you are passing to get the output in Dashboard and BW.
    It seems that some filters are missing in dashboard.
    Thanks
    Arvind Shukla

  • Data Mismatch between ODS and Infocube

    Hi,
    I have got data mismatch between from ODS to Infocube. In ODS for one Sender Cost Centre, there is only one Company Code. In Infocube it is showing many.For ODS datasource is 0HR_PT_1. In Updaterules of ODS, Company Code was assigned to Company Code. But in Infocube should  I assign CompCode to Comp Code or any other Characteristic as Master Data Attr of. Plz suggest us.
    It is very urgent.

    post ur  BW related querures in BW forum

Maybe you are looking for

  • How to create a SIS file for Nokia Communicator 9210?

    Hello, I have written a J2ME application, tested it (yes, it functions), and pressed on button "Package" in KToolbar. As result, I got a *.JAD and *.JAR file. When I copy these files to the Nokia Communicator 9210 Handy, nothing happens when opening

  • Photo transfer from comp to iphone

    I uploaded all the pics on my iphone to my comp. I erased all that was on the iphone. Now I want to put a couple of pics from my comp back on the iphone but don't know how to do that/ Can anyone help me? iPhone 3G 3.0

  • DirectToXMLType Mapping and XMLType functions

    Hi, I am using Toplink 11g, Weblogic 10.3 and Database Oracle 11g for my application. This application uses DirectToXMLType mapping. XMLtype column is mapped as String. Though I am able to create and query(findAll) the tables, I am not able to use sp

  • Issue iwth generic Datasource -Urgent Help

    HI All, I needed to create a generic DataSource through view . The view is created successfully however I have some dependant key figure in view such as Tips amount referring to MSEG(Referring Table ) _WAERS (Referred field name.) because of which I

  • How to Monitor RAC "Health" and how to Administer

    Now, we are using the RAC that we have setup... i am managing now 11.2.0.3 RAC on windows and 10.2.0.5 RAC on OEL... Can I ask, what are the things that needs to be checked in these setup...like what are the logs that I need to check.. how do i monit