Dynamically calling selection screen in loop

Hi all
    Please help me to solve this problem.I need to call a selection screen(like a dialog screen) containing 2 fields depending on the loop counter in a program.
Thank You.
Regards
Giri.

Hi
   I will explain indetail.I am displaying a SAPSCIPT throup program.Before displaying it I have to choose groupvalues or individual value.If it is individual then i don't have any problem because I have to display the dialog box which accepts details and current status values of that particular individual only once.But I don't know how to display dailog box which accepts these 2 values dynamically without knowing the number before for groupvalues.Because the group which we select may have 3,4 or any other number of individual values.Please help me.
Thank You.
Regards
Giri.

Similar Messages

  • Dynamically calling selection screens with obligatory

    TABLES :
    ******selection-screen: begin of block bal with frame title txt3.
    ******parameters: RB1  radiobutton group rd1 user-command abc default 'X'.
    ******parameters: RB2  radiobutton group rd1.
    ******selection-screen: end of block bal.
    ******selection-screen: begin of block B1 with frame title txt1.
    ******SELECT-OPTIONS  : s_cust  FOR KNA1-kunnr OBLIGATORY  MODIF ID r1.
    ******SELECT-OPTIONS  : s_plant  FOR plko-werks OBLIGATORY MODIF ID r1 .
    ******selection-screen: end of block val.
    ******selection-screen: begin of block upd with frame title txt2.
    ******SELECT-OPTIONS:  s_vend  FOR lfa1-lifnr OBLIGATORY modif id r2.
    ******SELECT-OPTIONS: s_plan  FOR plko-werks OBLIGATORY modif id r2.
    ******selection-screen: end of block upd.
    Here i need to call these two selection screens dynamically depends on radio buttion selection.
    But
    Problem is a arising when when both are obligatory in selection screen ( with out obligatory , it is working fine)
    I need to call screens dynamically, ecen though we have obligatory
    Let me know procedure , the possibility of same funcationality in tabstips & selection screen.
    Madhu

    Hi Madhu,
    You have to write code in AT SELECTION-SCREEN OUTPUT event.
    First of all remove obligatory from select-options declaration. Do it dynamically in AT SELECTION-SCREEN OUTPUT event.
    You enable or disable the block depending upon the rediobutton selected. Then in the venet AT SELECTION-SCREEN ON field, you can check whethere user has entered data into that field or not depending upon the radiobutton selected.
    TABLES : kna1,
             plko,
             lfa1.
    SELECTION-SCREEN: BEGIN OF BLOCK bal WITH FRAME TITLE txt3.
    PARAMETERS: rb1 RADIOBUTTON GROUP rd1 USER-COMMAND abc DEFAULT 'X'.
    PARAMETERS: rb2 RADIOBUTTON GROUP rd1.
    SELECTION-SCREEN: END OF BLOCK bal.
    SELECTION-SCREEN: BEGIN OF BLOCK b1 WITH FRAME TITLE txt1.
    SELECT-OPTIONS : s_cust FOR kna1-kunnr  MODIF ID r1.
    SELECT-OPTIONS : s_plant FOR plko-werks MODIF ID r1 .
    SELECTION-SCREEN: END OF BLOCK b1.
    SELECTION-SCREEN: BEGIN OF BLOCK upd WITH FRAME TITLE txt2.
    SELECT-OPTIONS: s_vend FOR lfa1-lifnr MODIF ID r2.
    SELECT-OPTIONS: s_plan FOR plko-werks MODIF ID r2.
    SELECTION-SCREEN: END OF BLOCK upd.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF rb1 EQ 'X'.
          IF ( screen-name EQ 'S_CUST-LOW'
            OR screen-name EQ 'S_CUST-HIGH'
            OR screen-name EQ 'S_PLANT-LOW'
            OR screen-name EQ 'S_PLANT-HIGH') .
            screen-active = '1' .
          ENDIF.
          IF ( screen-name EQ 'S_VEND-LOW'
            OR screen-name EQ 'S_VEND-HIGH'
            OR screen-name EQ 'S_PLAN-LOW'
            OR screen-name EQ 'S_PLAN-HIGH') .
            screen-active = '0' .
          ENDIF.
        ELSEIF rb2 EQ 'X'.
          IF ( screen-name EQ 'S_VEND-LOW'
            OR screen-name EQ 'S_VEND-HIGH'
            OR screen-name EQ 'S_PLAN-LOW'
            OR screen-name EQ 'S_PLAN-HIGH') .
            screen-active = '1' .
          ENDIF.
          IF ( screen-name EQ 'S_CUST-LOW'
            OR screen-name EQ 'S_CUST-HIGH'
            OR screen-name EQ 'S_PLANT-LOW'
            OR screen-name EQ 'S_PLANT-HIGH') .
            screen-active = '0' .
          ENDIF.
        ENDIF.
        MODIFY SCREEN.
      ENDLOOP.
    Regards,
    Anil Salekar

  • Short dump while using call selection-screen mdynnr

    Hi ALL,
    I need your help and information.
    In programmes, We are using the statament " CALL SELECTION-SCREEN MDYNNR " 
    and passing the screens dynamically into variable mdynnr.
    And the programme is going to dump after executing 50 times.
    When we
    can we use any other statement instead of CALL SELECTION-SCREEN MDYNNR.
    Your information helps us lot.
    Thanks in advance.
    Srinivasa Reddy.

    Hi,
    As you know Call Screen is the statement, but you will get the problem if you are going to call it in the same LUW repeatedly. So, FM is the only convenient way to do it. This is very easy. Just create a FM and replace you statement with this FM. Hopefully this will solve your problem.
    Check this comment " When you call a new main program in order to use a screen sequence (for example, using CALL TRANSACTION), a new SAP LUW begins. This may be an undesired effect, especially when you are trying to modularize a transaction that updates the database.
    An alternative to this is to use an external procedure, whose main program is linked to a screen sequence, and which contains the corresponding dialog modules. Procedures run in the same SAP LUW and internal session as their calling program."
    Thanks,

  • CALL SELECTION SCREEN problem

    Hello!
    I have a problem. In my riport I have a selection screen (1000), a main screen (2000), and a screen (400) this is called inside a loop, to fill some datas when you hit the print button.
      CLEAR L_TOTAL.
      SORT LT_EBAN BY BNFPO.
      LOOP AT LT_EBAN.
        GT_ITEM2-FIELD01 = SY-TABIX.
        GT_ITEM2-FIELD02 = LT_EBAN-MATNR.
    *---Part name, Type, Maker
        SPLIT LT_EBAN-TXZ01 AT ',' INTO GT_ITEM2-FIELD03 GT_ITEM2-FIELD04 GT_ITEM2-FIELD05.
         CONCATENATE GT_ITEM2-FIELD03 '/' GT_ITEM2-FIELD04 INTO DESCR.
         ITEM = LT_EBAN-BNFPO.
         CALL SCREEN 400 STARTING AT 20 7 ENDING AT 60 18.
    *---Machine
        GT_ITEM2-FIELD06 = ST_400-MACHINE.
    After this, i could not use the LEAVE TO SCREEN 0, because it's not going back to secreen '2000' , I'm getting a blank 400 screen.
    Thatswhy I used CALL SCREEN '2000', and it's fine.
    But in the case of the Selection screen (1000) something is wrong.
    On the screen 2000 I using this logic.
    MODULE EXIT_2000 INPUT.
      CASE OK_CODE.
        WHEN 'BACK' OR 'EXIT'.
          CLEAR OK_CODE.
           CALL SELECTION-SCREEN '1000'.
           LEAVE PROGRAM.
        WHEN 'CANC'.
          PERFORM EXIT_PROGRAM.
          LEAVE PROGRAM.
      ENDCASE.
      CLEAR OK_CODE.
    ENDMODULE.                 " exit_2000  INPUT
    With this logic, the program is going to the SELECTION-SCREEN, when I hit the back button, and when we are already on the SELECTION-SCREEN, it's leaving the program. This is also ok.
    But when I hit the back button, and on the SELECTION-SCREEN I want to run the program again, it's not going to the program logic, it's jumping to this CALL SELECTION-SCREEN '1000', and leaving of course.
    START-OF-SELECTION.
      PERFORM DSP1_PROC.
      IF GT_DISPLAY[] IS INITIAL.
        MESSAGE S208(00) WITH 'No data.'.
        EXIT.
      ENDIF.
      IF S_RET = '1'.
        MESSAGE I208 WITH 'Document not found'.
        S_RET = ' '.
      ELSE.
        S_RET = ' '.
        CALL SCREEN '2000'.
      ENDIF.
    So my question is, that the above logic, when I running the program first time It's working good, at the START-OF-SELECTION, but when I trying to runnig from the SELECTION-SCREEN "second time", from the   START-OF-SELECTION it's jumping to the CALL SELECTION-SCREEN '1000'. How can I avoid this. I want that from the  START-OF-SELECTION, never go to the CALL SELECTION-SCREEN '1000'.
    Thank You
    Edited by: Roland on Dec 5, 2011 11:27 AM

    Hi Max!
    Yeah, I was thinking the same, that the problem is with that loop.
    But I don't know, how can I solved in a different way, because when we hit the print button, we getting all the items from a table, and we starting looping on them. In the loop we passing the values to a GT_ITEM table, later this table is connected with an excell, so it will be printed out in an excell form.
    So I have to call this screen so many times, how many items we have. Sometimes just 1, sometimes 4, 6, 9, and so on.
    For this items I have to add 2 more fields, wich are uploaded by the user. ( The other fields are coming from the table)
    So if I going out from the loop after the CALL SCREEN 400, I think the next item wont be get the values. Or maybe any of them, because this is before the APPEND GT_ITEM. So this methode wont be called, no data would be in the table, nothing will be printed.
    *-Item
      SELECT BNFPO MATNR TXZ01 MENGE MEINS ERNAM PREIS BEDNR EBELN EBELP
        INTO CORRESPONDING FIELDS OF TABLE LT_EBAN
        FROM EBAN
       WHERE BANFN  =  GT_DISPLAY-BANFN
         AND LOEKZ  =  ' '.
      CLEAR L_TOTAL.
      SORT LT_EBAN BY BNFPO.
      LOOP AT LT_EBAN.
        GT_ITEM2-FIELD01 = SY-TABIX.
        GT_ITEM2-FIELD02 = LT_EBAN-MATNR.
    *---Part name, Type, Maker
        SPLIT LT_EBAN-TXZ01 AT ',' INTO GT_ITEM2-FIELD03 GT_ITEM2-FIELD04 GT_ITEM2-FIELD05.
         CONCATENATE GT_ITEM2-FIELD03 '/' GT_ITEM2-FIELD04 INTO DESCR.
         ITEM = LT_EBAN-BNFPO.
         CALL SCREEN 400 STARTING AT 20 7 ENDING AT 60 18.
    *---Machine
        GT_ITEM2-FIELD06 = ST_400-MACHINE.
    *---Using Qty
        WRITE ST_400-USING UNIT LT_EBAN-MEINS TO GT_ITEM2-FIELD08.
    *---Now Stock
        CLEAR L_LABST.
        SELECT SUM( LABST ) INTO L_LABST
          FROM ZMM0460T
         WHERE MATNR = LT_EBAN-MATNR
           AND WERKS = '3A10'.
        WRITE L_LABST UNIT LT_EBAN-MEINS TO GT_ITEM2-FIELD09.
        WRITE LT_EBAN-MENGE UNIT LT_EBAN-MEINS TO GT_ITEM2-FIELD10.
        IF NOT LT_EBAN-EBELN IS INITIAL.
          CLEAR LS_EKPO.
          SELECT SINGLE NETPR WAERS PEINH
            INTO CORRESPONDING FIELDS OF LS_EKPO
            FROM EKPO AS A INNER JOIN EKKO AS B ON A~EBELN EQ B~EBELN
           WHERE A~EBELN = LT_EBAN-EBELN
             AND A~EBELP = LT_EBAN-EBELP.
          IF LS_EKPO-WAERS <> 'HUF'.
            CALL FUNCTION 'CONVERT_TO_LOCAL_CURRENCY'
              EXPORTING
                DATE             = SY-DATUM
                FOREIGN_AMOUNT   = LS_EKPO-NETPR
                FOREIGN_CURRENCY = LS_EKPO-WAERS
                LOCAL_CURRENCY   = 'HUF'
              IMPORTING
                LOCAL_AMOUNT     = LS_EKPO-NETPR.
          ENDIF.
          IF LS_EKPO-PEINH IS INITIAL. LS_EKPO-PEINH = 1. ENDIF.
          LT_EBAN-PREIS = LS_EKPO-NETPR / LS_EKPO-PEINH.
        ENDIF.
        WRITE LT_EBAN-PREIS CURRENCY 'HUF' TO GT_ITEM2-FIELD11.
        CONDENSE GT_ITEM2-FIELD11.
        CONCATENATE GT_ITEM2-FIELD11 'Ft' INTO GT_ITEM2-FIELD11
          SEPARATED BY SPACE.
        L_NETWR = LT_EBAN-MENGE * LT_EBAN-PREIS.
        WRITE L_NETWR CURRENCY 'HUF' TO GT_ITEM2-FIELD12.
        CONDENSE GT_ITEM2-FIELD12.
        CONCATENATE GT_ITEM2-FIELD12 'Ft' INTO GT_ITEM2-FIELD12
          SEPARATED BY SPACE.
        L_TOTAL = L_TOTAL + L_NETWR.
    *---Unit
        SELECT SINGLE UNIT INTO GT_ITEM2-FIELD13
          FROM ZMM0500T
         WHERE PERNR = LT_EBAN-BEDNR.
    *---Name
        SELECT SINGLE SNAME INTO GT_ITEM2-FIELD14
          FROM PA0001
         WHERE PERNR = LT_EBAN-BEDNR
           AND ENDDA = '99991231'.
    *---Append
        GT_ITEM2-CNTR01 = ''.
        APPEND GT_ITEM2. CLEAR: GT_ITEM2, ST_400, DESCR, ITEM.
      ENDLOOP.
      GT_ITEM2-FIELD11 = 'Total'.
      WRITE L_TOTAL CURRENCY 'HUF' TO GT_ITEM2-FIELD12.
      CONDENSE GT_ITEM2-FIELD12.
      CONCATENATE GT_ITEM2-FIELD12 'Ft' INTO GT_ITEM2-FIELD12
        SEPARATED BY SPACE.
      GT_ITEM2-CNTR01 = 'B'.
      APPEND GT_ITEM2. CLEAR GT_ITEM2.
    ANy idea?
    Thank You
    Edited by: Roland on Dec 5, 2011 1:36 PM
    Edited by: Roland on Dec 5, 2011 1:50 PM

  • Call Selection Screen

    Hi,
    can any one give me good links for
    All variants of at selection screen..
    some thing on call selection screen
    Thx,
    Shashi

    ·     AT SELECTION-SCREEN
    You should only perform very expensive checks with AT SELECTION-SCREEN if the program is then started. Here, you can read the system field SSCRFIELDS-UCOMM (provided a statement TABLES SSCRFIELDS exists). If the field has one of the values 'ONLI' (= Execute) or 'PRIN' (= Execute and Print), the report is then started, i.e. the selection screen is closed and the processing continues with START-OF-SELECTION.
         Additions:
    ·     ... ON psel
    Effect
    This event is assigned to the selection screen fields corresponding to the report parameter or selection criterion psel.
    If the report starts an error dialog at this point, precisely these fields become ready for input.
    ·     ... ON END OF sel
              For each selection criterion sel on the selection screen, you can call a further screen by pressing a pushbutton. On this screen, you can enter any number of single values and ranges for the selection criterion sel..
    When this screen has been processed (i.e. at the end of PAI for this screen), the event AT SELECTION-SCREEN ON END OF sel is executed.
    At this point, all the values entered are available in the internal table sel.
    ·     ... ON VALUE-REQUEST FOR psel_low_high
    Effect
    In this addition, the field psel_low_high is either the name of a report parameter or of the form sel-LOW or sel-HIGH, where sel is the name of a selection criterion. The effect of this is twofold:
    1.     The possible entries pushbutton for F4 appears beside the appropriate field.
    2.     When the user activates this pushbutton or presses F4 for the field, the event is executed. You can thus implement a self-programmed possible entries routine for the input/output fields of the selection screen. If the program contains such an event and the user presses F4, the system processes this rather than displaying the check table or the fixed values of the Dictionary field.
    ·     ... ON HELP-REQUEST FOR psel_low_high
    Effect
    As with the addition ON VALUE-REQUEST the field psel_low_high is either the name of a report parameter or of the form sel-LOW or sel-HIGH, where sel is the name of a selection criterion. When the user presses F1 on the relevant field, the subsequent processing block is executed. You can thus implement a self-programmed help for the input/output fields of the selection screen. If the program contains such an event and the user presses F1, the system processes this rather than displaying the documentation of the Dictionary field - even if the report parameter or the selection option with LIKE or FOR points to a Dictionary field.
    ·     ... ON RADIOBUTTON GROUP radi
    Effect
    This event is assigned to the radio button groups on the selection screen defined by PARAMETERS par RADIOBUTTON GROUP radi.  If the report starts at an error  dialog at this point ,precisely these fields of the radio button group
    radi become ready for input again.
    ·     ... ON BLOCK block
    Effect
    This event is assigned to the blocks on the selection screen defined by SELECTION-SCREEN BEGIN/END OF BLOCK block. If the report starts at an error
    dialog at this point, precisely these fields of the block block become ready for input again.
         The events assigned to the radio button groups are executed according to the first parameter of the radio button group.
    The events assigned to the blocks are executed "from the inside to the outside".
    ·     ... OUTPUT
    Effect
    This event is executed at PBO of the selection screen every time the user presses ENTER - in contrast to INITIALIZATION. Therefore, this event is not suitable for setting selection screen default values. Also, since AT SELECTION-SCREEN OUTPUT is first executed after the variant is imported (if a variant is used) and after adopting any values specified under SUBMIT in the WITH clause, changing the report parameters or the selection options in AT SELECTION-SCREEN OUTPUT would destroy the specified  values. Here, however, you can use LOOP AT SCREEN or MODIFY SCREEN to change the inout/output attributes of selection screen fields. 
    ·     ... ON EXIT-COMMAND
    Effect
    This event is executed at the exit command of the selection screen - that is, at Back, Cancel, or End,events executed after the screen is sent that do not cause the system to check the input and execute the PAI.
    plz reward if useful
    vivek

  • Issue with CALL SELECTION-SCREEN

    Hi experts,
    I am working on a report.
    Here on the selection screen , based on the selection of some radiobuttons ,i want to call a secondary selection screen.
    So i am using the following program code ,
    AT SELECTION-SCREEN on BLOCk blk.
    IF p_abc  =  c_x.
        CALL SELECTION-SCREEN 100 STARTING AT 20 5.
        IF sy-subrc <> 0.
          MESSAGE text-011 TYPE c_e .
        ENDIF.
      ENDIF.
    so currently , once i complete my slection on the screen 100 , the popup screen stays there and rest of the programing logic is executed correctly.
    My issue is that , once i complete my slection on the screen 100, i want that the pop up should be closed
    And then the the rest of the program logic should continue.    
    please guide me how ,this can be done.
    Regards,
    Rajesh Kumar.

    Hi
    The event AT SELECTION-SCREEN and AT SELECTION-SCREEN ON BLOCK  are very similar, only the second event see the part of selection-screen defined in the block.
    This events are triggered as soon as the user does something: so press ENTER, F8,........
    If u want the second-selction screen is shown once and the main selection-screen has to be displayed under the second one, u can try to run the second one only if the report has to run, so if the user has pressed F8, code ONLI.
    AT SELECTION-SCREEN on BLOCk blk.
    CHECK SY-UCOMM = 'ONLI'.
    IF p_abc = c_x.
      CALL SELECTION-SCREEN 100 STARTING AT 20 5.
      IF sy-subrc 0.
         MESSAGE text-011 TYPE c_e .
      ENDIF.
    ENDIF.
    In tihs way the rest of the program will be executed, else u need to move all code of the event START-OF-SELECTION and END-OF-SELECTION in the event AT SELECTION-SCREEN, or, just as I said before, to move the calling of POPUP to event START-OF-SELECTION.
    Max

  • Problem in Call Selection Screen

    Hi,
    I am facing a problem on the call selection screen. The no. of nested screens that can be called by using call selection screen is 50. When the count reaches to 51 it is going to short dump. How can i avoid the dump. What is the system field that captures the nested screens count.
    Thanx in advance,

    Maximum number of nested CALL SCREEN is 50, I think you cannot call 51th screen in a row.
    To avoid short dump you can handle exception <b>DYNP_TOO_MANY_CALL_SCREENS</b> and give error (or information) message 'Maximum number of nested sccreen level is 50' .
      TRY .
          CALL SCREEN 100.
        CATCH cx_root .
          MESSAGE e100(00).
      ENDTRY.

  • To call Selection screen In BSP

    I have written a report "zdemo" in abap editor with some selection screen. I'm desperately looking for <b>_how to call Selection screen In BSP_</b>.
    Any kind of help will be apreciated.
    nikhil

    Hi Nikhil,
    There is no way that, you can call a selection-screen directly or create automatically as in the case of report in ABAP.
    The possible way could be
    Create one more page for holding the selection screen input fields with a submit button.
    On click on submit, do the processing and call the result page.
    Regards,
    Ravi

  • Back on a CALL SELECTION-SCREEN from an ALV

    Hi all,
    I have created a program with a normal selection-screen (1000).
    According to the selected values, when I press "Execute" I go to a next selection-screen (2000) with instruction CALL SELECTION-SCREEN 2000.
    Then I display an ALV.
    When I press the back button, I want to go back to screen 2000, but actually I go directly to screen 1000.
    PARAMETERS : p_choic1 RADIOBUTTON GROUP cho DEFAULT 'X'.
    PARAMETERS : p_choic2 RADIOBUTTON GROUP cho.
    SELECTION-SCREEN BEGIN OF SCREEN 2000.
    PARAMETERS : p_table TYPE char10.
    SELECTION-SCREEN END OF SCREEN 2000.
    START-OF-SELECTION.
      IF NOT p_choic1 IS INITIAL.
        CALL SELECTION-SCREEN 2000.
        PERFORM alv_process.
      ENDIF.
    Have you got any idea of what I can do to return to screen 2000 from the ALV after pressing Back button ?
    Thanks.

    Hi,
    Follow below sample code...
    SELECTION-SCREEN BEGIN OF SCREEN 2000.
    PARAMETERS p_mat  TYPE matnr.
    PARAMETERS p_enam TYPE ernam.
    SELECTION-SCREEN END OF SCREEN 2000.
    START-OF-SELECTION.
    set PF-STATUS 'STATUS'.
      WRITE:/ p_mat,
              p_enam.
    AT USER-COMMAND.
      CASE SY-UCOMM.
      WHEN 'S2000'.
          CALL SELECTION-SCREEN 2000.
      WHEN 'EXIT'.
          EXIT.
      ENDCASE.
    Ram.

  • Call selection screen in fm

    Hi all!
    I have a report, and i have a selection screen in a fm. Report call fm, and it bring me selection parameters.
    However i need run report in background, but option (F9) for do this, not visible. Somebody have any idea
    for resolve this ?
    pd: i should use fm. not using selection screen in traditional way.
    Thanks for ur answer.

    I'm not sure if anyone is looking for an answer here still, but I'll attempt an answer.
    Class Based exceptions cannot be propogated from a section of code that does not have a local memory area. This means Event (START-OF-SELECTION, AT SELECTION-SCREEN, etc) and Dialog Processing. Since the exception cannot be propogated, it hits the system and the system treats it as a dump scenario. In addition, due to the way Class Based Event Handling is processed, an exception cannot be propogated past an event handler.
    I am not sure if there is a work around for your problem though. One way may be to use a variable to store the exception that occurred; then when the Function Module itself has control again, check to see if that variable contains a value, it will raise the exception to the application that called the function. Using this and checks against this variable, you would be able to prevent further processing after the exceptions actual occurance.
    Global Data Definition
    DATA iException TYPE I VALUE 0 .
    Function Module
    CALL SELECTION-SCREEN 1234
    CASE iException .
      WHEN 0 .
       " do nothing, no exception occurred on selection screen.
      WHEN 1 .
         RAISE EXCEPTION CX_Your_Exception_Name .
    ENDCASE .
    AT SELECTION-SCREEN OUTPUT .
      IF [some condition] .
        iException = 1 . "If your exception occurred.
      ENDIF .
    This would allow you to use a global variable to log the exception and report it back to the function module; this will then allow the function module to propogate the correct exception back to the calling procedure.

  • CALLING SELECTION SCREEN.

    Hi All,
    My requirement is whenever i am clicking check box on selection screen one window selection screen shu apper where i will enter some data.After pushing execute button it should go to standard selection screen.
    code i hav wirtten as...
    Program *********************************************
    SELECTION-SCREEN BEGIN OF BLOCK 1 WITH FRAME TITLE text-003 .
    PARAMETERS: pa_ls1 AS CHECKBOX,
                            pa_ls2 AS CHECKBOX USER-COMMAND flag.
    SELECTION-SCREEN END OF BLOCK 1.
    SELECTION-SCREEN BEGIN OF SCREEN 2000 TITLE text-004.
    SELECT-OPTIONS: pa_vkorg FOR vbak-vkorg NO INTERVALS NO-EXTENSION.
    SELECTION-SCREEN END OF SCREEN 2000.
    at selection-screen.
    IF pa_ls2 = 'X'.
    do.
        CALL SELECTION-SCREEN '2000'
        STARTING AT 10 10.
        exit.
    enddo.
      ENDIF.
    with this code i am able to call the screen but cant go back to standard screen.

    HI RUSHIKESH,
    MODIFICATION HAS BEEN MADE INTO YOUR CODE.SEE THE BOLD PART.
    REPORT  ZCLICK.
    tables : vbak.
    SELECTION-SCREEN BEGIN OF BLOCK 1 WITH FRAME TITLE text-003 .
    PARAMETERS: pa_ls1 AS CHECKBOX,
    pa_ls2 AS CHECKBOX USER-COMMAND CLICK.
    SELECTION-SCREEN END OF BLOCK 1.
    SELECTION-SCREEN BEGIN OF SCREEN 2000 TITLE text-004.
    SELECT-OPTIONS: pa_vkorg FOR vbak-vkorg NO INTERVALS NO-EXTENSION.
    SELECTION-SCREEN END OF SCREEN 2000.
    at selection-screen.
    IF pa_ls2 = 'X'.
    <b>PA_LS2 = ''.</b>
    CALL SELECTION-SCREEN '2000'
    STARTING AT 10 10.
    ENDIF.

  • Call selection screen exit

    Hi,all
    I've found a problem arising from this sentence "call SELECTION-SCREEN 1001 STARTING AT 10 10",in the main screen. (here the type of screen 1001 is 'Modal Dialog Box')
    The 'close' button on the right-top correr of the screen has no effect to close the
    screen 1001,so how can I catch the event of click on that button?
    Thanks

    you need to write the code as below
    case sy-ucomm.
    when 'EXIT'.
    leave to screen 0.  " always use screen 0 for modal dialog box.
    when "BACK'
    leave to screen 0
    WHEN 'CANC'.
    leave to screen 0
    endcase.
    Please activate buttons in Menu Painter.
    Thanks
    Seshu

  • How to create check boxes dynamically in selection screen

    Hi Experts,
    I have a requirement of creating dynamic check boxes based on the number of records that are retrieved from a database table.
    Can you please suggest me how to achieve it.
    Regards
    RP.

    Hey RP,
    Try this way.
    REPORT ztest_program .
    DATA: it_data TYPE TABLE OF t001.
    DATA:check    TYPE char3.
    DATA:sy_index TYPE char2.
    DEFINE checkbox.
      parameters:&1 as checkbox.
    END-OF-DEFINITION.
    CHECKbox:c01,c02,c03,c04,c05,c06,c07,c08,c09,c10,
             c11,c12,c13,c14,c15,c16,c17,c18,c19,c20,
             c21,c22,c23,c24,c25,c26,c27,c28,c29,c30,
             c31,c32,c33,c34,c35,c36,c37,c38,c39,c40.
    AT SELECTION-SCREEN OUTPUT.
      DESCRIBE TABLE it_data LINES sy-tfill.
      sy-tfill = 39. "This will be changed based on the itab records. I just hardcoded the value
      sy_index = 1.
      LOOP AT SCREEN.
        CONCATENATE 'C' sy_index INTO check.
        IF screen-name = check.
          IF sy_index GT sy-tfill.
            screen-active = '0'.
            MODIFY SCREEN.
            sy_index = sy_index + 1.
            CONTINUE.
          ENDIF.
          sy_index = sy_index + 1.
        ENDIF.
      ENDLOOP.
    Thanks
    Venkat.O

  • Calling selection screen depends on radio buttion selection

    I need to call two selection screens (not radio buttons selection screens) depends on radio buttion selection
    Eg :
       R1-radio button
      R2- radio button
    if we select R1- we should get selection screen to enter input values like parameters, select options
       PARAMETERS:     p_abc TYPE    MARA-matnr OBLIGATORY
      SELECT-OPTIONS: s_mno  FOR   MARC- chngr OBLIGATORY.
      PARAMETERS:     p_xyz TYPE     MARA - amktxOBLIGATORY.  (just example)
    If we select R2, we should get selection screen to enter input values like parameters, select options
    PARAMETERS:         p_abcd TYPE    KNA1-matnr OBLIGATORY
      SELECT-OPTIONS:  s_mnop  FOR   VBAK- chngr OBLIGATORY.
      PARAMETERS:        p_xyza TYPE     VBAP - amktxOBLIGATORY  (just example)
    if we select 1 , other should be hide
    Madhu

    Hi,
    this is an example:
    SELECTION-SCREEN BEGIN OF BLOCK B2 WITH FRAME TITLE TEXT-002.
    PARAMETER R1 RADIOBUTTON GROUP G1 DEFAULT 'X' USER-COMMAND SET1.
    PARAMETER R2 RADIOBUTTON GROUP G1 .
    SELECTION-SCREEN BEGIN OF BLOCK B21 WITH FRAME TITLE TEXT-004.
    PARAMETER: P1 LIKE IBIPPARMS-PATH MODIF ID FPA.
    SELECTION-SCREEN END OF BLOCK B21.
    SELECTION-SCREEN BEGIN OF BLOCK B22 WITH FRAME TITLE TEXT-004.
    PARAMETER: P2 LIKE IBIPPARMS-PATH MODIF ID FPB.
    SELECTION-SCREEN END OF BLOCK B22.
    SELECTION-SCREEN END OF BLOCK B2.
    DATA: P_CHECK.
    AT SELECTION-SCREEN OUTPUT.
      IF P_CHECK <> 'X'.
        LOOP AT SCREEN.
          IF SCREEN-GROUP1 = 'FPA' OR
             SCREEN-GROUP1 = 'FPB'.
            SCREEN-INPUT = '0'.
            SCREEN-INVISIBLE = '1'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
        P_CHECK = 'X'.
      ENDIF.
      IF R1 = 'X'.
        LOOP AT SCREEN.
          IF SCREEN-GROUP1 = 'FPA'.
            SCREEN-INVISIBLE = '0'.
            SCREEN-INPUT = '1'.
            MODIFY SCREEN.
          ENDIF.
          IF SCREEN-GROUP1 = 'FPB'.
            SCREEN-INVISIBLE = '1'.
            SCREEN-INPUT = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.
      IF R2 = 'X'.
        LOOP AT SCREEN.
          IF SCREEN-GROUP1 = 'FPB'.
            SCREEN-INVISIBLE = '0'.
            SCREEN-INPUT = '1'.
            MODIFY SCREEN.
          ENDIF.
          IF SCREEN-GROUP1 = 'FPA'.
            SCREEN-INVISIBLE = '1'.
            SCREEN-INPUT = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.
    Angelo.

  • Call Selection screen of other program..

    Hello ABAP Experts,
    I have a situation where in I need to call the selection screen of one sap generated standard program without executing that program & get the values of those selection variables in to my custom program. Is there a way to do that? Please help.
    Thanks,
    Pandu

    If it is static or one program I could have done like that. But the nature of the  program is dynamic & not just one program.

Maybe you are looking for

  • Getting connection error on windows xp with connector-java-3.1.10 for Mysql

    Hi, I am using Mysql 4.1.13 with Tomcat 5 and Connector mysql-connector-java-3.1.10 on Windows XP machine. When I try to update the table in batch mode sometimes( When server is idle for a long time) get following error. ERROR [com.userdefined.Schedu

  • Using Primitive Arrays in JPA

    Is it possible to persist and store arrays of primitive types using the Java Persistence API? If so, is there any special annotation that the array requires?

  • Table data not processed

    Hi, I use oracle 10g DB. It receives data every 5 minutes from the hardware. There is a job called etl_mgr that runs every 5 minutes and processes these recordds and moves the processed data to some other table so that my application displays that da

  • How to mirror my iPad to my iPhone for presentations?

    I have recently used airserver to mirror my iPad to my mac. I use this setup for presentations, where I want to move freely across a room with my iPad, while my mac is hooked up to a Videoprojetor. I got thinking? Is there a way to mirror my iPad to

  • Display Trade Price for all Customers - Trade Price maintained at Material

    Dear All, I have a specific requirements, for which there is a data model as: 1] Primary Sales: stored in an InfoCube (Level at which data is stored- Material/Customer) 2] Secondary Sales: stored in an ODS (loaded through Flat File) (Level at which d