DYNPRO_ITAB_ERROR

Please assist
SDCCN provides the error.

Hello Rahisker,
In the short dump, you should see the problem  was with screen name /BDL/SAPLBDL11 and there will be screen number referenced something like like 0745 and 0780, but they could be different.
Therefore please test and activat the screens referenced in the dump in se51. Then you should be able to
see the settings in SDCCN correctly.
Regards,
Paul

Similar Messages

  • Runtime Errors DYNPRO_ITAB_ERROR

    I receive this shortdump when I try to logon after a heterogenious system copy from windows mssql to linux maxdb.
    Initially when i am trying to login using gui i am getting this error
    Here is some more details from my shortdump
    This is the test system migration
    Note 1287210 - System copy and DYNPRO_ITAB_ERROR
    I have gone through the note but the main problem is source system kernel patch level is less than the target system. What will be the solution for this problem? 
    Runtime Errors DYNPRO_ITAB_ERROR
    Date and Time 26.04.2011 08:18:21
    Short text
    Error in internal table in screen
    What happened?
    The current screen processing action was terminated since a situation
    occurred where the application could not continue.
    This is probably due to an error in the ABAP program or in the current
    screen.
    Error analysis
    The program "SAPMSYST" has terminated.
    The following error occurred (short text of cause of error):
    "FX099: Wrong fieldtype for CURSOR. Has to be binary/hex type."
    The following elements are affected:
    Screen name.............. "SAPMSYST"
    Screen number............ 0020
    This error is connected to the processing of an internal table with the
    field or variable "TC_IUSRACL-CURRENT_LINE", and was triggered within in the program.
    Trigger Location of Runtime Error
    Program SAPMSYST
    Include SAPMSYST
    Row 1,073
    Module type (MODULE PBO)
    Module Name D020_LOGON_WITH_SNC
    Please can any one help me in solving this issue
    Thanks
    Srikanth

    Hi Vardhan,
    Read this sap note:
    Note 1287210 - System copy and DYNPRO_ITAB_ERROR
    [https://websmp130.sap-ag.de/sap%28bD1lbiZjPTAwMQ==%29/bc/bsp/spn/sapnotes/index2.htm?numm=1287210]
    Thanks
    Siva

  • Creating key figures in report writer

    Hello,
    i'm making a new report painter/ writer and i find a problem. The process that i've made already is:
    1- create a view table with the tables i need.
    2- make the corresponding entries into T804A and T804E tables.
    3- I create the library for my Z table.
    4- then i go to GS32 to create key figures and i get nothing. We are in 4.6C.
    I tried to import/ export key figures from other libraries and SAP says that all is imported, but in GS32 i have no one either.
    If i go to GR22 and push 'key figures' button for my library i get a dump. It says:
    ABAP runtime errors    DYNPRO_ITAB_ERROR
    What happened?
                                                                                    The current screen processing was terminated, since a situation
    occurred from which it could not continue processing.
    This is probably due to an error in the current screen of the ABAP
    program.
    Error analysis
                                                                                    Program "SAPMGRWL" was terminated.
                                                                                    The following error occurred: (short text of error cause)
    "FX100: An attempt was made to read beyond end of internal table."
                                                                                    Affected:
    Screen name..............."SAPMGRWL"
    Screen number.............0613
                                                                                    This is an error that occurred during processing of an internal table in
    conjunction with field or variable "INDEX_FROM".   
    Some help??. I will reward.

    I have now resolved this issue.
    I had to manually update TablesT804B and T804F. 
    I've added entries to T804A in the past without the need to update T804B or T804F manually so it appears that the way these tables work together has changed following an upgrade or application of support packs.
    Regards
    Mel

  • WebSAPConsole , telnet serever ,RF terminal and SAP logon screen

    What would be the easiest way to connect RF terminal(character based) to an SAP system.
    Of course it is via WebSAPconsole. As far as I red WebSAPconsole guide if I want to use it to connect character based RF terminal is the same as preaviously SAPconsole(under e.g.SAP enterprise 4.7 ext2.)
    1.st install telnet server (best SLnet 2.6RF from Seattle LABS) and then configure In SAP console administrator in Control panel entered corresponding system ip,sysnr and transaction code(from saplogon)
    However on RF terminal SAP logon screen does not appear. But only telnet prompt.
    What to do? Should the  telnet server and SAP console be on an other machine than SAP server(ECC6)?

    Hi Thomas Kremer,
    Can you help me to solve this issue!?
    I´m facing with same error then you. I did a homogenous  system copy and after I finish this SAPINST I install the saplogon and of course I try to accede to SAP system and the first thing that display in system is that short dump -->  dynpro_itab_error
    What´s this?! How you solve this issue... can you remmember? (I know that already was a two years ago but even so if you remember this can you share with me!?).
    Best regards,
    João Dimas - Portugal

Maybe you are looking for

  • Cannot sync videos from iTunes to iPhone 5S

    I recently got an iPhone 5S 32 GB.  I restored it through iTunes from a backup of my old iPhone 4S 16 GB.  Since the restore, & after an upgrade to iOS 8.0.2, I can no longer sync videos from iTunes 11.4.0.18 to the iPhone.  Previously I had been syn

  • Apple TV loosing Signal with TV

    After about a year of using Apple TV all of a sudden it started cutting out.  The picture then comes back and cuts out again and so on.   Tried upgrading, didn't fix it.  So can an Apple TV device break?  Was working and now, not so much !!!

  • Error in Account Segmentation

    Hi Experts I have created account Segment Branch Code With Size 8 and Alphanumeric. When I try to create branch code of 5 Characters i am getting an error ISR 27 characters Regards Joby J Abraham

  • Replication on database objects

    Dear all, There are 2 database on separate locations (A & B). We want to have replication like any database objects have been changed (tables, procedures) in Location A, it will automatic apply to Location B. Any exisiting function in database for 9.

  • Swapping phone purchased from Dell w/add-a-line

    We recently added an additional line to our Family Plan, for my son. We did this through Dell (really, the transaction went through Simplexity, which also runs Wirefly), and by doing so we got a discount on a Fascinate. My son decided he doesn't like