EDM Profile Allocation
Hi experts,
I have been trying to allocate the profile to an interval register, but I get an error as given below:
Record not found in table EPROFASSROLE
Can someone please guide what are the standard SPRO settings for
Define Roles for Profile Allocation
Allocate Operand Roles
so that Profile allocation can be carried out.
With thanks & regards,
Vinodh
Vinodh,
standard SPRO settings are delivered by SAP (roles for profile allocation config), example roles 0001 u2013 0009.
You might be interested that the flag "RA - Role Used for Allocation of Profile to Register" is set for your role.
I have never used any config for Allocate Operand Roles
Hope this helps, Tom
Similar Messages
-
De-allocating EDM Profile of an Interval Meter attached to an installation
My dear friends, I need sincere help from you .
This is an ISU requirement on which ABAP/functional suggestions are required.
I have an installation with an interval device installed to it.
We need to do full removal of this installed device by eg32.
The interval meter is having EDM Profile attached to it. Before doing full removal of the device from the installation using EG32,
we need to de-allocate the EDM Profile attached to this interval meter. Manually this is done by using transaction code - EEDM04
but we need to do deallocation of profile using ABAP code.
We need your help in this regard. Could you suggest ISU function modules that could be used to do the deallocation of the EDM profile from the interval Device/Meter.
Your help is really needed and appreciated!
Thanks,
RohitI think function module ISU_S_PROFASS_CHANGE might be useful.
Isnt't it an option to prorate the profile allocation on device removal?
You can set system parameter PRORATEPRO for this in customizing of device management:
PRORATEPRO (Limit Prof. Alloc. for Rem./Repl./Mod./Chnge to Logical
Reg.)
During device installation/replacement/removal or when changing the
logical register number, you can use this parameter to control
whether the allocations of the profile to the register are limited.
Edited by: evolderen on Apr 15, 2010 8:23 AM -
Remove EDM Profile from Interval Meter of an installation-Device Management
My dear friends, I need sincere help from you .
I have an installation with an interval device installed to it.
We need to do full removal of this installed device by eg32.
The interval meter is having EDM Profile attached to it. Before doing full removal of the device from the installation using EG32,
we need to de-allocate the EDM Profile attached to this interval meter. Manually this is done by using transaction code - EEDM04
but we need to do deallocation of profile using ABAP code.
We need your help in this regard. Could you suggest ISU function modules that could be used to do the deallocation of the EDM profile from the interval Device/Meter.
Your help is really needed and appreciated!
Thanks,I think function module ISU_S_PROFASS_CHANGE might be useful.
Isnt't it an option to prorate the profile allocation on device removal?
You can set system parameter PRORATEPRO for this in customizing of device management:
PRORATEPRO (Limit Prof. Alloc. for Rem./Repl./Mod./Chnge to Logical
Reg.)
During device installation/replacement/removal or when changing the
logical register number, you can use this parameter to control
whether the allocations of the profile to the register are limited.
Edited by: evolderen on Apr 15, 2010 8:23 AM -
Table for EDM Profile with Installation or Device numbers
Hi
Can anybody answer Table for EDM Profile with Installation or Device numbers?
Thanks in advance.
DGRHello,
You allocate the profile to a register so you want to have your logical register number.
If you have the equipment number you could go to table ETDZ or call FM ISU_DB_ETDZ_SELECT and fetch the registers.
If you want to see the table of profile allocations you can check table EPROFASS.
If you use IS-U-EDM the tables which contains informations about profile values are EPROFVAL*...
Hopefully some of this infomation is useful for you.
Regards
Olivia -
Hi,
I Ihave developed a report to upload edm profile at an interval of 15 minutes.I am fetching installatiion number ,date ,unit of consumption and the consumption values at 15 mins interval from a text file.My report is inserting values to the database table EPROFVAL15,but while iIam trying to see the profile values through the transaction EEDM02(by giving the installation number and selecting a profile) then m unable to see the values.Can anyone tell me the cause of the above problem .
I have used the function module ISU_DB_EPROFVAL15_UPDATE to insert values.Is this problem related to the time zone.actually in the database the profile values should get inserted for a profile 5.30 hours before(for example: on 30.06.2010 for profile no:50
consumption value for time 00:00:00 should get stored on 29.06.2010 at 00:18:30).
regards.
pratibhaneed to ask some other question so winding up things replies are always welcome
-
Update Consumption Value in EDM Profile From Meter Readings in DM
Dear,
Can it be possible that consumptions values from meter readings (for non interval readings / Non AMR meters) in DM imported / transfered to profiles in EDM.
Sohail AshrafIn general non-interval measured point of deliveries are dealt with by a synthetic profile.
The synthetic profile is assigned to the installation and can be normed, e.g. to 1000 kWh.
In most cases you will have several synthetic profiles, where each one is used for customers that have such a profile.
Then in billing the usage factor is updated in such a way that the usage factor * normed consumption = actual consumption of customer. So if the customer consumed 2600 kWh the usage factor would be 2,6 for that period if his synthetic profile is normed to a 1000kWh. -
Non-standard EDM Profile intervals
Can 15 minutes intervals like 05,20,35,50 be accommodated in EDM.
00:05
00:20
00:35
00:50
01:05
23:50
To my knowledge, it cannot be. We just had got an interval meter readings like that under a test scenario. Also it does not make sense as the RTP pricing has a very slim chances to be in that format.
However would like to confirm from the experts.
With thanks & regards,
VinodhYes you can.
P.S One small note, while using EDM please see the below area for correctness of interval length:
1. RTP interface
2. Register settings for maintaining interval length
3. Profile Header creation.
All of them should have ideally the same length of interval.
Edited by: born2bdahero on Oct 3, 2011 4:18 PM -
hi friends
i have got an issue in profile creation in edm
when i tried to create profile header t code eedm06 i selected the interval length as price but its asking for unit of measurement..actually it must ask only for currency..
but its asking for both currency and unit of measurement
can any 1 help me with this????
regards
princehi friends
atlast the error has been solved.for this error u need to assign the energy and price in sproedmprofile managementdefine units of menasurment
here v need to maintain the diviosn and profile value category with kwh
in my case it was
electricity price and energy was the data entered in that screen
and it worked
thanks and regards
prince -
Hi all,
Could someone tell me what is the industry standard of profile values under Profile value Category "Quantity", whether it is readings or consumption.
As of now when we compute the billed quantity it is calculated as sum of the profile values, indicating the profile values are consumption values.
Are there also scenarios where meter readings (instead of consumption) are used in profile values. If so what is the procedure to compute the consumption
With thanks & regards,
VinodhProfile values are typically consumption (electricity or gas, resp. kWh and m3) or demand (electricity, kW).
I have not seen a scenario where the profile contained the readings. However if the meter (or metering system) would provide this information on a periodic time basis it would be no problem to store it in a profile.
Consumption would then have to be derived in the RTP interface from the readings in the period billed. -
Hi all,
While importing profile values from MS-Excel file (in transaction "Change profile header") the system is giving error "Error Importing Date, Check import file". I would like to know if any specific date format, different than exported file, is to be used. How do we import the profile values for test purposes i.e. without using BAPI/IDoc?Hi,
If the format in SAP is dd.mm.yyyy, you should also be having format dd.mm.yyyy in your OS. If your OS is Windows, then under Control Panel, you have to make the necessary changes under u201CChange the format of numbers, dates and timesu201D. This is likely to solve your problem.
With thanks & regards,
Vinodh -
EDM Profile upload and Timezone
Hi friends
When importing profile values using std BAPI, I am facing a problem, my time zone is EST ( UTC-5) but the data from interval (CMEP format) meter is in UTC thus a value of 05:00:00 in the file is actually 00:00:00 in the system. Now it is becoming difficult to match the data against the local time ( EST) both in Table and in display during profile value upload
I have tried changing the time zone in the system and in user profile. can you please help
Thanks
joyHi Roy,
Use FM ISU_DATE_TIME_CONVERT_TIMEZONE. On table TTZZ, you have the all existing Time Zones.
Here a Test for you case with FM test interface.
Import Parameters Value
X_DATE_UTC 02.10.2008
X_TIME_UTC 05:00:00
X_TIMEZONE UTC-5
Export Parameters Value
Y_DATE_LCL 02.10.2008
Y_TIME_LCL 00:00:00
Hope that this is exactly what you mean.
KR,
AAL! -
hi friends
prince here.in edm while am creating a synthetic profile in details tab there is a input for day group.when i gave my day grp the system popus an error as follows
select the day type in the tree structure
and the notes for the error is as follows,
Select the day type for which you want to maintain the profile allocation
You must enter a season group and a day group in order to display the day types as selectable nodes in the tree structure.
all suggestions are valuable and rewardable
kr
princeHi Prince,
spro>edm>basic setings>day grp>define day groups-->select day grp and maintain definition
here u need to maitain day types.
Have u maintainded these.
Regds,
Narendar Konaknchi -
EEDM01 EEDM02 Profile values Enhancement
Hi,
I was looking on a way to enhance the EDM Profile values transactions (EEDM01/02) by adding some extra fields in the ALV showing the profile values.
Since I haven't found any Screen-exits or BAdI, are you aware about any solution to achieve that?
Regards,
JohnCheck table EPROFVALSTAT that your profile values also have a status for the period you are looking at in EEDM02.
If they don't then they won't show up.
If there is no status then something must go wrong in your upload. Check the STAT in the PROFILEVALUES parameter in your BAPI call. Make sure it is translated from external to internal status in customizing. -
I am trying to configure RTP for real time scenarios like index prices which will be coming as input from market.We have done some configuration on this but on billing we are getting bill as Normal bill i.e. Total amount . I want to see the calculation as per the intervals ? e.g every 30 mins.
Also If I have to attach prices for every 30 mins How can I do that ? If we have to use price profile ...then we cannot create a RTP operand for price as RTP operand will be used only for Quantity,demand & Amount.
Any help will be appriciated.
thanksI think you have 2 options:
1. If you just want to bill each 30 mins with a price then you can create a formula profile for each customer that is to be billed like this.
The profile should have PV category Amount and as a formula you may use LIMIT02. Define the limit as 0 and all your consumption will be above the limit and evaluated with the price profile.
You would then have to calculate your formula profile to be able to bill the customer. The RTP interface can then calculate the total amount and if you require eg. peak demand.
2. You can do it completely in the RTP interface.
Define a price profile and use this as an input parameter, either by role or enter the specific profile number in the RTP interface, to your formula.
As the other input parameter use your quantity profile, allocated by role.
Then your formula will calculate price * quantity and return a profile. The result functions in the RTP interface result parameters make it 1 value (the sum, minimum or maximum or any other function you define).
Make your formula store the calculated result profile as well, by finding the result profile to store on based on the input profile (allocation to register, profile role to find right profile).
Option 1 is the most simplistic and would need no custom development. -
Plz help me how to handle the meter exchange for an interval meter. This meter is a cumulative interval meter. What I have done
a) Entered the cumulative reading for old meters in the profile.
b) Carried out the meter exchange
c) Enter the cumulative reading for the new meter
I then created formula profiles which will convert the reading to consumption. This formula calculation is not considering the meter exchange. The calculation is carried-out as if there is no exchange happened for the meter and it has given me the wrong consumption.
can you plz tell me how the exchange of cumulative meters with interval reading are handled normally
Thanks and regards,Hi,
If you are exchanging like to like meters then SAP will handle it exactly the same way as it does for another meter. The profile allocation will have to be terminated prior to the exchange and then once the exchange is done you can allocate it to the new meter.
For unlike meters as long as you have less registers in the new meter and no other different register you should be ok. Otherwise you will have to do a remove and install.
Thanks,
Raj.
Maybe you are looking for
-
Opening EPS file in Photoshop 7.0, blacked out, can't see vector cutouts
this is a 10 year old eps file. we used it to make vinyl cutout stickers. after opening in PS7, it's just black squares, without all the cutouts in each square. when opened in notepad, these are the 1st 2 lines... %!PS-Adobe-2.0 EPSF-2.0 %%Creator:Sc
-
How to do a JSP talks with my "EJB from tables" ?
Hi !! I'm new to Jdev. I have built a database, using MySql, and I also have built EJB from my tables. My EJB are Entity Beans and I have used the Wizard to create it from tables of my data base. Every EJB is working well and I have a simple JAVA cli
-
Where are printer paper profiles stored in Mavericks?
In previous versions of OS X, I could find where my printer paper profiles were stored. I have some test paper profiles that don't work and I want to delete them but I can't find them in Mavericks 10.9.2 I have done a search for their name but appare
-
IMovie on iPad - cannot add recorded song
I just bought the iMovie for iPad. I have tried many times to add a recorded song which is in mp3 format from the iTunes library to the project I'm working on. But when I tap it, iMovie just has no reaction. It works fine for other songs, the dark gr
-
Same vendor for local & import purchasings
Hi, is it possible to use the same vendor as a local & import vendor ? is it possible to classify the same vendor with calssification settings ? any possible way to do this activity, plesae advice, rgds