EM 12C Integration with SCOM 2012

Hi
Has anyone integrated EM12C ( running on Solaris Sparc ) with MS SCOM 2012 ? Just looking for any hints / tips /issues ... etc ...
Any thoughts appreciated.
Regards
Rob

If the integration is along the lines of forwarding events from Enterprise Manager 12c to SCOM, then we are currently finalizing an event connector for SCOM 2012. It will enable the sending of events from Enterprise Manager to SCOM.
Regards,
Ana

Similar Messages

  • OEM integration with SCOM 2012

    Hi, 
    Can anyone help me out on the topic- OEM integration with SCOM 2012.

    Are you refer to this document
    Oracle® Enterprise Manager Installation and Configuration Guide for Microsoft System Center Operations Manager Connector
    http://docs.oracle.com/cd/E24628_01/install.121/e28572.pdf
    Roger

  • SCCM 2012 integration with SCOM 2012 - Disable Alerts during patching

    Have SCCM 2012 R2 and SCOM 2012 R2 and use the Software Update Patching process for servers.  When using the checkbox to "Disable Operations Manager Alerts when this program runs" option have noticed on completion of the job and the target
    server is rebooted, a scheduled task appears for a short time titled "SCOM 2007 Agent Resume Task".  The task disappears and there is no history to view.
    Is this a legacy naming convention from 2007 world when the maintenance mode is turned off from the SCCM patching process?
    How do I see the actual code behind the SCCM and SCOM integration with Maintenance mode to validate it.

    SCCM should use the following SCOM SDK to do that.
    http://msdn.microsoft.com/en-us/library/bb437532.aspx
    That's incorrect. There is no API or method to put an OpsMgr agent into maintenance mode on the client itself -- maintenance mode is a centrally controlled feature of OpsMgr. The API/code sample you linked is performing that activity on the management server
    which assumes you know the management server name and have permissions to carry out the action -- neither of which is fulfilled by the ConfigMgr agent.
    The ConfigMgr agent pauses the OpsMgr client agent service and also unloads the workflows from the OpsMgr agent (it only did the first part in ConfigMgr 2007). This effectively puts the agent in Maintenance Mode (although to my knowledge this is not directly
    reflected in the OpsMgr console).
    Jason | http://blog.configmgrftw.com

  • The problem with forecast reports in SCOM 2012 after integration with VMM 2012

    Hello.
    I have problem with forecast reports in SCOM 2012 after integration with VMM 2012. All other reports (not forecasting) works fine. For example, report “Host Group Forecasting” don’t work. The report is generated, but I have error: “Subreport
    could not be shown”. I find only errors in SQL Server Reporting logs like this:
    library!ReportServer_0-13!1758!06/26/2012-18:26:23:: i INFO: RenderForNewSession('/Microsoft.SystemCenter.VirtualMachineManager.2012.Reports/Microsoft.SystemCenter.VirtualMachineManager.2012.Report.ForecastHostGroup')
    processing!ReportServer_0-13!1758!06/26/2012-18:26:28:: e ERROR: Throwing Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: , Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Не удалось выполнить
    запрос для набора данных "DiskSpaceUsageForecasting". ---> Microsoft.AnalysisServices.AdomdClient.AdomdErrorResponseException: Execution of the managed stored procedure GetTimeSeriesForecast failed with the following error: Exception has been thrown by
    the target of an invocation..
    Query (5, 58) Parser: The syntax for '6' is incorrect.
       at Microsoft.AnalysisServices.AdomdClient.AdomdConnection.XmlaClientProvider.Microsoft.AnalysisServices.AdomdClient.IExecuteProvider.ExecuteTabular(CommandBehavior behavior, ICommandContentProvider contentProvider,
    AdomdPropertyCollection commandProperties, IDataParameterCollection parameters)
       at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.System.Data.IDbCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.ReportingServices.DataExtensions.AdoMdCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.ReportingServices.OnDemandProcessing.RuntimeDataSet.RunEmbeddedQuery(Boolean& readerExtensionsSupported, Boolean& readerFieldProperties, List`1 queryParams, Object[] paramValues)
       --- End of inner exception stack trace ---;
    The Russian string “Не удалось
    выполнить запрос для набора данных "DiskSpaceUsageForecasting"” is translated to “Could not execute query for data set "DiskSpaceUsageForecasting"”.
    I have clean installation SCOM 2012 RU1, VMM 2012 RU1. Integration SCOM with VMM work fine.
    SQL collation for all SQL DB instances (SCOM and VMM and SCOM reporting) – “SQL_Latin1_General_CP1_CI_AS”
    SQL Analysis service: SQL collation – “Latin1_General” ; language for the server – English (United States)
    I think the problem in regional settings. By my opinion there are two possible mistakes:
    SQL collation  for all SQL DB instances. May be need use “Latin1_General_CI_AS”
    as provided by
    http://blogs.technet.com/b/momteam/archive/2012/05/25/clarification-on-sql-server-collation-requirements-for-system-center-2012.aspx
    Need change regional setting. Question is for what (OS regional setting, SQL Analysis service settings,…) ?

    Error: Subreport could not be shown
    Opening a report for Client Security might result in the following error being displayed in one or more areas of the report: "Error: Subreport could not be shown."
    Background
    There are two possible reasons for this error:
    1. Wrong location   The reporting server is pointing to the wrong computer running SQL Server or a SQL Server instance.
    2. Insufficient permissions   The account configured (in SQL Server Reporting Services) to connect to the reporting database does not have appropriate permissions for the database.
    Solution
    To determine which reason is causing the error, attempt to directly open the subreport reporting the error, by clicking the name of the subreport.
    If the reporting server is pointing to a wrong location, the report displays an error similar to the following: 
    Error message
    An error has occurred during report processing.
    Cannot create a connection to data source 'SystemCenterReporting'. Cannot open database "SystemCenterReporting" requested by the login. The login failed. Login failed for user username.
    To verify the correct SQL Server computer and instance path
    In Report Manager, navigate to the report generating the error and click the Properties tab.
    Click Data Sources and under a Shared data source, note the path.
    Open the reporting Web site. If you chose the default virtual directory for reports, the URL is: http://hostname/Reports/
    If you chose to secure the viewing of reports with HTTPS, the URL is: https://hostname/Reports/
    Click SCDW.
    In the Connection type list, ensure that Microsoft SQL Server is selected.
    In the Connection string box, ensure that the correct SQL Server computer and instance name are entered.
    Note:
    A period (.) denotes the local computer.
    If the account has insufficient permissions, the report displays an error similar to the following: 
    Error message
    An error has occurred during report processing. (rsProcessingAborted) Query execution failed for data set 'DSDashboardComputersTrend'. (rsErrorExecutingCommand) EXECUTE permission denied on object 'prSAS_UX_DashboardComputersTrend', database 'SystemCenterReporting',
    schema 'dbo'.
    To determine if you are experiencing the SQL Server permissions issue
    Open the reporting Web site. If you chose the default virtual directory for reports, the URL is:http://hostname/Reportserver/
    If you chose to secure the viewing of reports with HTTPS, the URL is:https://hostname/Reportserver/
    Click Microsoft Operations Manager Reporting, click Microsoft Forefront Client Security, and scroll to DashboardComputersTrend.
    Click DashboardComputersTrend.
    If you are experiencing a SQL Server permissions issue, an error similar to the preceding error appears.
    To grant permissions to the SQL Server computer
    1. In Report Manager, click SCDW and note the account in the Connect using section. This is the account under which the database is contacted.
    2. On the server with the System Center Reporting database, start SQL Server Management Studio.
    3. In the tree, expand Security, and then expand Logins. Do one of the following:
    If the user account is listed, right-click the account, click Properties, and then go to step 5.
    If the user account is not listed, right-click Logins and choose New Login.
    4. In the Login name box, enter the user account (domain\username).
    5. In the Login Properties dialog box, click User Mapping, and then under Users mapped to this login, select the System Center Reporting check box.
    6. Under Database role membership for: System Center Reporting, select the db_owner check box, and then click OK.
    Thanks,
    Yog Li
    TechNet Community Support

  • Remove SCVMM2012 Integration in SCOM 2012

    Hi @all
    i had a SCOM 2012 - SCVMM 2012 integration ... and now i re-installed the SCVMM Server with Windows Server 2012 and SCVMM 2012 SP1 ... i thought everything´s fine .. but now i noticed, that system discovery in SCOM 2012 does not work .. and i guess that
    is caused by the old SCVMM Integration ...
    how can i remove an obsolete scvmm 2012 integration on SCOM 2012 Server  ? ...

    Hi
    Before removing the old VMM server, you really needed to go into Settings and System Center Integrations and remove the SCOM integration. That would have removed the conectors from SCOM as well.
    Do you still see all the old VMM Connectors in SCOM?
    In VMM, have you tried reconfiguring the SCOM integration? Do you see a green tick or red cross? If not, then try re-adding to see if the new integration will work. You'll also need to upgrade Management Packs in SCOM.
    Regards
    Graham
    Regards Graham New System Center 2012 Blog! -
    http://www.systemcentersolutions.co.uk
    View OpsMgr tips and tricks at
    http://systemcentersolutions.wordpress.com/

  • Remote WSUS integration with SCCM 2012

    Hi,
    We are currently having WSUS already in place for Patching , but not used at all its just installed.
    can remote WSUS be integrated with SCCM 2012 server which is on different server ? what is the best practice ? is it to have WSUS on same server as Primary server?
    or I decommission it and install a new WSUS on same server as SCCM server.
    what steps have to be taken care if remote WSUS is integrated ? any documents or steps to be taken care .
    Thanks in Advance

    When you install SUPs, they automatically configure the underlying WSUS instance to sync from an upstream server based upon your ConfigMgr hierarchy.
    A couple of notes here though:
    - You generally shouldn't use an existing instance of WSUS for ConfigMgr. Once integrated into ConfigMgr, WSUS should no longer manage approvals, update binary downloads, or update binary distribution as these are all handled by ConfigMgr separate from WSUS.
    Using an existing WSUS instance where this was the case can be problematic at best and will cause unexpected behavior and results.
    - Clients do not choose SUPs based upon boundaries or location so using a remote SUP is typically not beneficial and in many cases will cause additional network load. The exception to this is if the SUP is within a secondary site.
    Jason | http://blog.configmgrftw.com | @jasonsandys

  • Dell server hardware component monitoring with scom 2012 R2.

    hello ..
    We have some dell poweredge r710 SFF 2X SIX CORE X5 SAS Servers ,I need to monitor its hardware components with scom2012 R2.I have installed os:windows server hyper-v server on this and windows server core OS management packs on scom and monitoring
    working fine  .next I want to know their is Latest Management pack available for this  dell model server and what are hardware components can be monitored with scom 2012 R 2. I want to monitor Hardware failure such as   Power failure ,cpu failure,disk
    failure and NIC failure etc
    Thanks
    Richa

    Hi,
    Please refer to the User’s Guide of the DELL MP:
    http://support.dell.com/support/edocs/software/smconect/msscom/40/en/ug/pdf/Dell_Server_Management_Pack_Suite_v4.0_UG.pdf
    Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Meanwhile, considering this is related to DELL products, if you need more information or further investigation, please also contact DELL support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Issues with Monitoring Azure services with SCOM 2012 R2

    Hi,
    I'm trying to setup monitoring of our Azure subscriptions in a new installation of Operations Manager 2012 R2 which is running in-house as it is also monitoring our internal services.  I've used the guide below:
    http://blogs.msdn.com/b/walterm/archive/2013/04/13/first-impressions-on-system-center-management-pack-for-windows-azure-fabric-preview-for-scom-2012-sp1.aspx
    This has all worked OK and I've been able to add the subscription into OP Manager and it's found the cloud service, storage and VM's.  However when I try to add the monitoring and I go to create this When I select the Add option in the Add Monitoring
    Wizard and click the Search button to list the components (Cloud Service, Storage and VM's) nothing is found despite me having already selected the subscription.
    Has anyone else experienced this or can offer any advice?
    Many Thanks
    Colin

    Hi,
    Which version of RDP client you are using for your client?
    Does more user login at same period of time?
    As you have commented that after sticking the user can’t able to login in RDCB server, here I can suggest you to check the setting of connection broker. Also you can check that you have place the proper location path of UPD while configuring in collection configuration
    wizard. You can take a look at below article foe virtual desktop configuration.
    Deploying Virtual Desktops with Windows Server 2012
    Are you trying to use same UPD for different collection then also it might happens to occur your issue. The fact of UPD is User profile disks are for a single collection only. A user connecting to two different collections will have two separate profiles. If
    you want to synchronize settings, refer to Microsoft User Experience Virtualization. Go through this article for more understanding related to UPD.
    Working with User Profile Disks on Session-Based Desktop Deployments
    Hope it helps!
    Thanks.

  • Exchange 2010 and 2013 Monitoring with SCOM 2012

    HI all,
    I have exchange 2013 and 2010 in my environment , Iwant monitor both in SCOM 2012,
    Can you all please tell can i implement 2013 monitorinng first later can i go to 2010 Monitoring, Please advise in that supported or do i need to go with exchange 2010 monitoring first

    There are no dependencies on the 2010 MP so you should be good to go, see the following:

  • Airwatch MDM integration with sccm 2012

    I want to integrate Airwatch MDM with SCCM 2012 SP1. I am not able to find out any documentation for the same. Can anybody help me with the said.
    Thanks and Regards Deepak

    There is an integration between AirWatch and ConfigMgr 2012. I've never used it so I can't comment on it.
    https://tool.microsoftsca.com/Partner/?id=737
    Watch the video here
    http://airwatch.wistia.com/medias/7463a8aae8
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

  • Issues with SCOM 2012 Agent on Red Hat 5 Server

    We are running SCOM 2012 server and have deployed the agent successfully to a number of Red Hat Linux servers. I am having an issue on about a quarter of the hosts, in that they appear as HEALTHY but are Grayed out and not green. When I look at the /var/opt/microsoft/scx/log/omiserver.log
    file I see:
    WARNING: wsman: authentication failed for user scom2012
    I have verified that the system account is setup with the correct password and the runas account is setup with the correct password (i am able to deploy the agent from the SCOM server using it, so the passwords DO match).
    Any ideas? 

    We are running SCOM 2012 server and have deployed the agent successfully to a number of Red Hat Linux servers. I am having an issue on about a quarter of the hosts, in that they appear as HEALTHY but are Grayed out and not green. When I look at the /var/opt/microsoft/scx/log/omiserver.log
    file I see:
    WARNING: wsman: authentication failed for user scom2012
    I have verified that the system account is setup with the correct password and the runas account is setup with the correct password (i am able to deploy the agent from the SCOM server using it, so the passwords DO match).
    Any ideas? 
    I've seen this on a few systems here when the agent has been upgraded but the old agent process does not die off.  Just to rule it out, pick a node, make sure there are no instances of scxcimserver or scxcimprovagt and then start the agent and
    see if the issue goes away.  I've also seen wsman authentication failures related to the libssl issue that was fixed in yesterday's release.

  • Monitoring services on MSMQ cluster with SCOM 2012

    Hello guys,
    I'm looking a way that SCOM 2012 is able to monitor several services installed on MSMQ cluster. I think it's possible that SCOM 2012 can generate alert through the message queuing service associated to these services but this is an indirect monitoring. I
    would want that SCOM generates the alert for the specific service in problem.
    Any suggestion?
    Thank you very much.

    Hi,
    There is a management pack for ​Message Queuing.
    You can download it from http://www.microsoft.com/en-us/download/details.aspx?id=36775
    Hope it help's
    Greetings,
    Roel Knippen
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • Remedy CMDB Integration with SCCM 2012

    We are facing an issue with duplicate entries of Hostname after remedy is integrated with SCCM2012.We have created custom view in SQL database which mapped to remedy database.Below is the query used for the integration.Can I get any help on this?
    SELECT DISTINCT
                          dbo.v_GS_COMPUTER_SYSTEM.Name0, CASE WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0 IN ('3', '4', '6', '7', '15')
                          THEN 'Desktop' WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0 IN ('8', '9', '10', '21') THEN 'Laptop' WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0
    IN ('1')
                          THEN 'VDI' WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0 IN ('2', '17', '23') THEN 'Server' END AS Chassis, dbo.v_GS_PC_BIOS.SerialNumber0,
                          dbo.v_GS_COMPUTER_SYSTEM.Manufacturer0, dbo.v_GS_COMPUTER_SYSTEM.Model0, dbo.v_GS_OPERATING_SYSTEM.Caption0,
                          dbo.v_GS_OPERATING_SYSTEM.CSDVersion0, dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0,
                          dbo.v_R_System.User_Name0 AS [Last Logged], dbo.v_GS_PC_BIOS.ReleaseDate0, dbo.v_GS_NETWORK_ADAPTER_CONFIGUR.IPAddress0,
                          dbo.v_R_System.AD_Site_Name0, dbo.v_GS_NETWORK_ADAPTER_CONFIGUR.DefaultIPGateway0, dbo.v_GS_X86_PC_MEMORY.TotalPhysicalMemory0,
                          dbo.Processor_DATA.Name00, dbo.Processor_DATA.Manufacturer00 AS Expr2, dbo.Processor_DATA.ProcessorType00, dbo.Processor_DATA.NumberOfCores00,
                          dbo.CH_ClientSummary.LastHW, dbo.CH_ClientSummary.LastSW, dbo.v_R_System.Last_Logon_Timestamp0, dbo.v_GS_COMPUTER_SYSTEM.Domain0
    FROM         dbo.v_GS_PC_BIOS INNER JOIN
                          dbo.v_GS_COMPUTER_SYSTEM ON dbo.v_GS_PC_BIOS.ResourceID = dbo.v_GS_COMPUTER_SYSTEM.ResourceID INNER JOIN
                          dbo.v_GS_NETWORK_ADAPTER_CONFIGUR ON dbo.v_GS_COMPUTER_SYSTEM.ResourceID = dbo.v_GS_NETWORK_ADAPTER_CONFIGUR.ResourceID INNER JOIN
                          dbo.v_GS_OPERATING_SYSTEM ON dbo.v_GS_OPERATING_SYSTEM.ResourceID = dbo.v_GS_COMPUTER_SYSTEM.ResourceID INNER JOIN
                          dbo.v_R_System ON dbo.v_GS_COMPUTER_SYSTEM.ResourceID = dbo.v_R_System.ResourceID LEFT OUTER JOIN
                          dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP ON
                          dbo.v_GS_COMPUTER_SYSTEM.ResourceID = dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.ResourceID INNER JOIN
                          dbo.v_GS_SYSTEM_ENCLOSURE ON dbo.v_GS_COMPUTER_SYSTEM.ResourceID = dbo.v_GS_SYSTEM_ENCLOSURE.ResourceID INNER JOIN
                          dbo.v_GS_X86_PC_MEMORY on  (dbo.v_gs_x86_pc_memory.ResourceID = .v_GS_COMPUTER_SYSTEM.ResourceID) inner JOIN
                          dbo.Processor_DATA ON dbo.Processor_DATA.MachineID = dbo.v_R_System.ResourceID INNER JOIN
                          dbo.CH_ClientSummary ON dbo.CH_ClientSummary.MachineID = dbo.v_R_System.ResourceID
    WHERE     (dbo.v_GS_NETWORK_ADAPTER_CONFIGUR.IPEnabled0 = 1) AND (NOT (dbo.v_GS_NETWORK_ADAPTER_CONFIGUR.DefaultIPGateway0 IS NULL)) AND (dbo.v_GS_X86_PC_MEMORY.TotalPhysicalMemory0 >=512)
    Thanks,
    Shijil

    Thank you Nash for your help.
    I tried with dbo.v_R_System_Valid  as suggested, still the same result.Is there any way to filter duplicate computer name in this query?
    Below is the query.
    SELECT
    DISTINCT
    dbo.v_R_System_Valid.Netbios_Name0,
    CASE WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0
    IN ('3',
    '4',
    '6', '7',
    '15')
    THEN 'Desktop'
    WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0
    IN ('8',
    '9',
    '10', '21')
    THEN 'Laptop'
    WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0
    IN ('1')
    THEN 'VDI'
    WHEN v_GS_SYSTEM_ENCLOSURE.ChassisTypes0
    IN ('2',
    '17',
    '23') THEN
    'Server' END
    AS Chassis, dbo.v_GS_PC_BIOS.SerialNumber0,
    dbo.v_GS_OPERATING_SYSTEM.Caption0,
    dbo.v_GS_OPERATING_SYSTEM.CSDVersion0, dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0,
    dbo.v_R_System.User_Name0
    AS [Last Logged], dbo.v_GS_PC_BIOS.ReleaseDate0, dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION.IPAddress0,
    dbo.v_R_System.AD_Site_Name0, dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION.DefaultIPGateway0,
    dbo.v_GS_X86_PC_MEMORY.TotalPhysicalMemory0,
    dbo.Processor_DATA.Name00, dbo.Processor_DATA.Manufacturer00
    AS Expr2, dbo.Processor_DATA.ProcessorType00, dbo.Processor_DATA.NumberOfCores00,
    dbo.CH_ClientSummary.LastHW, dbo.CH_ClientSummary.LastSW,
    dbo.v_R_System.Last_Logon_Timestamp0
    from 
    dbo.v_GS_PC_BIOS
    inner JOIN
    dbo.v_R_System_Valid
    ON dbo.v_GS_PC_BIOS.ResourceID
    = dbo.v_R_System_Valid.ResourceID
    INNER JOIN
    dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION
    ON dbo.v_R_System_Valid.ResourceID
    = dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION.ResourceID
    INNER JOIN
    dbo.v_GS_OPERATING_SYSTEM
    ON dbo.v_GS_OPERATING_SYSTEM.ResourceID
    = dbo.v_R_System_Valid.ResourceID
    INNER JOIN
    dbo.v_R_System ON dbo.v_R_System_Valid.ResourceID
    = dbo.v_R_System.ResourceID
    LEFT outer
    JOIN
    dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP
    ON
    dbo.v_R_System_Valid.ResourceID
    = dbo.v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.ResourceID
    INNER JOIN
    dbo.v_GS_SYSTEM_ENCLOSURE
    ON dbo.v_R_System_Valid.ResourceID
    = dbo.v_GS_SYSTEM_ENCLOSURE.ResourceID
    INNER JOIN
    dbo.v_GS_X86_PC_MEMORY
    on  (dbo.v_gs_x86_pc_memory.ResourceID
    = .v_R_System_Valid.ResourceID)
    inner JOIN
    dbo.Processor_DATA
    ON dbo.Processor_DATA.MachineID
    = dbo.v_R_System.ResourceID
    inner JOIN
    dbo.CH_ClientSummary
    ON dbo.CH_ClientSummary.MachineID
    = dbo.v_R_System.ResourceID
    WHERE    
    (dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION.IPEnabled0
    = 1)
    AND (NOT
    (dbo.v_GS_NETWORK_ADAPTER_CONFIGURATION.DefaultIPGateway0
    IS NULL))
    AND (dbo.v_GS_X86_PC_MEMORY.TotalPhysicalMemory0
    >=512)
    Thanks,
    Shijil

  • How to setup Tiering with SCOM 2012 class libraries?

    Hi All,
    I've two SCOM servers installed in two different machines and SCOM will have some alerts. I want to connect the two so that one acts as top tier and other one as lower tier. The top tier will show all the alerts from the lower tier in
    the connected alerts. From there I'm passing the alerts to external system for processing. I want to establish the tiering programmatically using the SCOM 2012 API. I know of method
    TieringManagement.AddTier Method (String, ManagementGroupConnectionSettings, SecureData, Boolean)
    Help me how can I achieve this by using the above method.
    Thanks in advance.
    viRa

    To configure method TieringManagement.AddTier Method, you can refer to below links
    http://msdn.microsoft.com/en-us/library/hh332072.aspx
    http://msdn.microsoft.com/en-us/library/hh350608.aspx
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer".

  • Windows 2012 upgrade plan to R2 hosted with SCOM 2012 SP1

    Dear Experts,
    Currently we are hosting SCOM 2012 SP1 on Windows 2012 Operating System and the Server team plan to upgrade Windows server OS 2012 to Windows OS 2012 R2. 
    So, Is there any Potential road blocks and things to take care for SCOM 2012 SP1 if we want to upgrade the Windows 2012 R2 OS.
    Thanks,
    Saravana
    Saravana Raja

    Hi,
    I have seen this a couple of times without any issues.
    Just make sure you backup all SCOM related (databases if local, management packs etc).
    www.coretech.dk - blog.coretech.dk

Maybe you are looking for

  • I can't get my iTunes to update to the new version.

    I updated my iPod and so I need to update my iTunes. When I try it tells me this: "Error writing to file: C:\Program Files\Common Files\Apple\Mobile Device Support\SyncServices\Schemas\Calendars.syncschema\Contents\Resources\ja.lproj\L ocalizable.str

  • ICloud displaying deleted iCal events

    I set up my iCloud/iCal sync when I updated to iOS5, but my iCloud calendar (and thus my iPhone calendar) is now displaying events I have deleted from iCal on my MacBook Pro. Why is this happening and how can I fix it?

  • Wrong Case or ClassCastException

    Hello everyone I use JWSDP2.0, JDK is jdk1.5.0_12 I have tried to generate class by the command: xjc -p test.jaxb poll.xsd Following is the schema <?xml version="1.0" encoding="UTF-8"?> <xsd:schema xmlns:xsd="http://www.w3.org/2001/XMLSchema" element

  • CXML PO posting on HTTPS url

    Hi, My scenario is to post an cXML PO document on HTTPS url using XI. I tried to import cXML DTD (standard) in XI, but it is of no use, as Vendor wants a customize cXML message. My approach is to create an underline xml structure in XI and then using

  • Quicktime Plugin fullscreen mode ?

    Well, every other video plugin let's you view a video in fullscreen. How can you to that with Quicktime ?