Enhance standard 2LIS_17 extractors in an operative SAP R/3

Hi experts,
I need your help in a special activity that I need to do, I'm going to enhance the 2LIS_17_I3HDR to include some standard fields through LBWE transaction, the complication that I see in my future is activate the delta extraction, because the source system is operative and the plants works 7x24, what you recommend us to do this activity in the better way, preventing that some orders don't get lose in the extraction. 
How can I proceed to do this and have low impact?.
Thanks for your help.
Regards

Hi ,
first let us know how want data for added fields?
want historic data or not?
One more thing in case LO.
User lock is mandatory.
if we do the transports without lock then next delta pointer will be corrupted due to extract structure changes. so you may loose those records which are created/changed in time gap.
Better to have user lock on ecc system/related t codes.
later to do the transports and follow other steps as per need
Situation: if you need historic data
1. you need user lock as per you source data volume.
at bw side need to delete whole data and reload.
so here, you need to delete setup tables data and fill whole data.
run full load with init.
later you can do unlock and continue with delta loads.
situation: don't need historic data then
need user lock at minimum time.
clear all delta queues from ecc and move to bw.
later you can do you can transport changes to ecc prod and bw prod.
later you can do unlock and continue delta loads.
Thanks

Similar Messages

  • SAP Standard BI extractor for EhP4/5 Performance Management Solution

    Hi,
    Are they any SAP Standard BI extractors for Performance Management Solution EhP4/5? Could you please be so kind to tell me where can i find the info about it?
    ...Naddy

    [here|http://help.sap.com/erp2005_ehp_05/helpdata/EN/3e/80d8cd269142db93cdcffeecfa2a93/frameset.htm] is the BI Content foe EhP5 Perf.Mgt,

  • Enhance the 0vendor_attr extractor

    Hi All,
    I am new to BW. I want to enhance the 0vendor_attr extractor and add payments term 'ZTERM' from table LFB1. Please let me know the step by step procedure to do it.
    Also what exactly are the steps taken to transport objects in landscape. Please let me know in details.
    Thanks.

    Hello,
    payment terms are stored at company code level (primary key in LFB1 = BUKRS and LIFNR) which means that you can have two different payment terms for one vendor thus you shouldn't enhance 0VENDOR_ATTR...
    They're two master data source for ZTERM: 0VEN_COMPC_ATTR and 0VEN_PURORG_ATTR...
    I suggest to activate the corresponding business contetn IObj ( 0VEN_COMPC and 0VEN_PURORG) and load them; you'll get then 0PMNTTRMS populated by standard business content...
    for the texts of 0PMNTTRMS you'll have to create a generic DSource based on table TVZBT.
    hope this helps...
    Olivier.

  • Enhancing standard component with new component usage

    Hi!
    I try to enhance standard component /SAPSRM/WDC_AOFC_BEV with new component usage (say, SALV_WD_TABLE). It allows me to add new usage, but the usage does not appear in the "Component Usages" tree node.
    Is it a bug? Is it possible to enhance a standard component with new component usage?

    Hi Thomas!
    We've been communicating with SAP on this issue for a while and last response we obtained is next:
    Dear customer,
    the possibility to create external controller usages (as required for
    the ALV-usage) is not supported by the Web Dynpro ABAP development
    tools. However, you could try a programmatic apporach by adding the
    ALV-usage dynamically (e.g. in methods or method exits created within
    your enhancement implementation).
    See test component WDR_TEST_DYN_ALV_USAGE for details.
    What's your opinion on this? Is it really not a bug?

  • Standard Content Extractors

    Hi,
    New project upgrade from ecc5.0 to ecc6.0.
    It's not BW upgradation.In this change what kind of problem will come.
    Is there any problems will occur in Standard Content Extractors .
    Please respond immediatly.
    Thanks
    Vasu.

    Hi
    check this link....for upgradadation
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/2e8e5288-0b01-0010-2ea8-bcd4df5084a7
    also check
    https://websmp204.sap-ag.de/~sapdownload/011000358700009385902004E
    hope it helps.
    cheers.
    Message was edited by:
            tarun bafna

  • What is Enhancement and why is it required in SAP?

    What is Enhancement and why is it required in SAP?
    Message was edited by:
            Rajalekshmi V

    Hi,
    SAP designed some standard scenmarios to meet most of the clients requirements. But still it won't suit the clients exact business spcifications, so we ned this enhancements.
    it's basically to enhance the Std SAP as per the clients requirements.
    An enhancement includes one or more components (function exits, menu enhancements, screen enhancements). For enhancements, you are recommended to observe the following naming convention.
    We add fields using the Screen exits, desing menu's using menu exits and Function exits to enhance the std functionality of the programs.
    reward if useful
    regards,
    Anji

  • Enhance standard BAPI

    Hi All,
    I have a standard BAPI called BAPI_BUPA_CREATE_FROM_DATA. I need to enhance that BAPI. Could you please let me know how to enhance this standard BAPI. Any help will be very much appreciated.

    You can enhance a standard bapi if it has EXTENSIONIN , EXTENSIONOUT Parameters.
    check this.
    [Enhance standard bapi|https://forums.sdn.sap.com/click.jspa?searchID=25041527&messageID=3667604]

  • Impact of enhancing standard infotypes on service pack upgrade

    Hi SAP experts,
    I have a situation where in we had enhanced standard infotype 14 ( added custom fields to structure CI_P0014) in development systems and moved to production systems. Now these changes should be moved to project system in which the service pack upgrade is in progress. Will it impact the SP upgrade if I move my transports to these systems? Will it overwrite the sp changes for IT14?
    P.S : The support pack was not applied to the system in which the std infotype was enhanced.
    Regards,
    Sameena

    You should re-apply any customer enhancements etc to your development environment after SP's are applied - But only after you have a developer review potential impacts from SP and your development.
    I think you would be fine as IT14 isn't updated often in SP's.
    Cheers,
    Brad

  • Enhancing Standard webdynpro component

    Hi friends,
    I have never worked on enhancing standard web dynpro components,
    Now i have got  requirement, In SRM webdynpro component  i have to place Custom Label and  Custom Hyper Link, when i click on that hyperlink, one pop up window shud be open, can any please guid how to enahnce this standard webdynpro component
    Thnx
    Kumar Srini

    Hi,
    To Enhance any standard compoenent, and specially a "VIEW" just follow the below steps:
    1. Go to SE80, Give the Component Name and press Enter
    2. Go to the Desired "View"
    3. Click enhance button (ICON Like spiral,6th from left to right of Application toolbar)
    4. A Pop up will appear asking your Coposite Enhancement name  and Enhancement Implementation name. Create "NEW" on both the occasion.
    Now for UI Enhancements:
    a) Click the "ROOT UI Element container" , right click add the custom UI elements and assign Property values as per your requirement( like binding,text,action etc.,). It is just like adding UI elements in Z-Compoent.
    b) Create actions wherevr required
    For Coding Level enhancements:
    Here, for all the methods which are in the standard compoenent will have "PRE" and "POST" Exits. The difference is "PRE" Exits will render before calling the actual code and "POST" Exit will render after rendering the actual code.
    Note: Till Enhancement Pack (EHP3) we had only PRE & POST Exits. And Now on from EHP 4 and More we do have an option "OVER WRITE" Exit.
    Apart from Exits, we can create our own Events/event Handlers. These Event Handlers will work only for the enhancements.
    We Can write our own logic in the newly created event/event handler.
    Regards,
    S.Meganadhan

  • Enhance Standard Infotype 1005 in HR

    Dear All,
    Please suggest how to enhance standard infotype 1005 - Planned Compensation in HR.Transcation PM01 is not allowing to do so ...as no CI include is attached for the same.
    Please guide.
    Regards,
    Subhash

    hi,
      maybe you can achieve your requirement by creating a new custom OM infotype
    ( if the custom information are linked to the OM entity :  org unit, positions.. ) or a new PA infotype ( if the custom information are linked to the employee ) .
    Regards luigi
    Edited by: luigi la motta on Sep 2, 2011 11:46 AM

  • Standard users of workflow provided by sap

    I need to know who r all the standard users of workfow Provided by SAP like (WF-BATCH).where can i find the list of these standard users.Kindly help me in this issue.
    Thanks in advance,
    Ramesh Kumaar.S

    Hi Ramesh,
    Your question is not clear. The user names used by workflow is :
    WF-ADMIN
    WF-BATCH
    If no agents are found for a given task the workflow is sent to workflow admin (WF-ADMIN).
    All the background tasks/methods are executed by the workflow batch (WF-BATCH) user.
    All other users in workflow are the user names who use the SAP system (end users). They are the workflow agents.
    Regards,
    Raj

  • No data coming in to enhanced fields of extractor

    I added fields twice to  the existing enhanced business content extractor 0fi_gl_4, I wrote the transactional data exit and did the extraction, the extraction went with green light. when i checked the data in ods, i dont see any data for the enhanced fields, including the earlier enhanced fields which used to be populated before i did this enhancement.
    when i look at load in monitor
    it is all green, but when i go to scheduler to do another test load it is giving me the following message
    Conv. exit PERI7 for field FISCPER not found in BW; Exit deleted
    Message no. RSM1149,
    > is this the reason for no data in my enhanced fields....if so how do i get rid of it?
    > do i need to delete and recreate the datasoure
    so that all the enhaced fields lie in same append structure, if so how do i recreate the datasource...?
    > plz also help me debug my enhancement, i tried rsa3 it doesnt show an error, i tried break point but no use..
    plz give me detailed instructions..
    thanks in advance
    points will be assigned for inputs

    do i need not add exit even if i did an append structure to the datasource? (bcoz in help it says only about include structure )
    do you know how to do an include structure to the datasource instead of append?
    i tried making an infinite loop in exit and do a data load..the load has taken sucessfully without an error and i checked the data , the enhanced fields are empty..so i concluded that it is not even calling the exit? any idea of how to fix it ? plz give me ur mail id ..i will send some screen shots?
    regarding the conversion exit error, this is all i am getting, when i click on the error there is nothing but the same decription
    Conv. exit PERI7 for field FISCPER not found in BW; Exit deleted     RSM1     149     \
    > any way to look up by error message and number?

  • How to get standard program ,script,smartforms all from sap

    hi friends
    how to get standard program ,script,smartforms all from sap.
    thanks&regards
    Babasish

    Hi,
    reports:
    goto se38
    all programs not starting with y or z will be sap std programs only
    same for se71 scripts
    samse for smartforms
    but the use of those will be known when you see the documentation
    for each programme
    for std programs there will be documentation available so that you can understand
    why they have developed that object
    thanks & regards,
    Venkatesh

  • Standard Labor Hours for a Operation

    Hi, we are on 11.5.10.2 version of Oracle and I am need of locating in the database where I can find standard labor hours for an operation. Any help would be appreciated!

    The std. labor hours are in a table called bom_operation_resources.
    Try this
    select msi.segment1 item
    ,bos.operation_seq_num OP_SEQ_NUM
    ,bd.department_code
    ,br.resource_code
    ,bors.usage_rate_or_amount
    from mtl_system_items msi
    ,bom_operational_routings bor
    ,bom_operation_sequences bos
    ,bom_departments bd
    ,bom_operation_resources bors
    ,bom_resources br
    where msi.organization_id=&org_id
    and msi.segment1='&item'
    and msi.inventory_item_id = bor.assembly_item_id
    and msi.organization_id = bor.organization_id
    and bor.routing_sequence_id = bos.routing_sequence_id
    and bos.department_id = bd.department_id
    and bors.operation_sequence_id = bos.operation_sequence_id
    and bors.resource_id = br.resource_id
    order by msi.segment1, bos.operation_seq_num, bors.resource_seq_num
    Hope this answers your question
    Sandeep Gandhi
    Independent Consultant
    513-325-9026

  • How to enhance Standard Extractor for 0CUSTOMER_ATTR

    Hi,
    I need to enhance the standard extractor of 0CUSTOMER_ATTR in order to populate the newly added attributes.
    I have few questions:-
    1) Will there be any impact of manually adding attributes to 0CUSTOMER on the data flow/where used list of 0CUSTOMER.
    2) In order to get the master data for newly added attributes we will need to enhance the extractor. Could you let me know the entire process of enhancing the standard extractor.
    3) Will it be safe to make a copy of 0CUSTOMER as ZCUSTOMER, add the new attributes in ZCUSTOMER and use ZCUSTOMER for our requirement. In this case also we will need to enhance the extractor.
    Your inputs will be helpful.
    Thanks,
    Naveen Kr. Choudhary

    1) Will there be any impact of manually adding attributes to 0CUSTOMER on the data flow/where used list of 0CUSTOMER.
    No there will not be any impact for the where used list of 0CUSTOMER info object, there will be effect once the enhanced data source is replicated to BI side.
    2) In order to get the master data for newly added attributes we will need to enhance the extractor. Could you let me know the entire process of enhancing the standard extractor.
    SE11 --> create the Structure
    Tcode: RSA6 -> Double click on the Data source --> Now in the DS:customer version screen you can see the extract structure name --> double click on it -->Next you will find an option of Append Structure button --> click on it -->
    Add the necessary field's in the Append Structure with Component Type:. Before you exit, make sure that you activate the
    structure by clicking on the activate button.
    Next
    -->You need to confirm that the Added filed has been added to the DataSource and that it will be available to BW. When you go  back at the Postprocess Datasource and Hierarchy screen(RSA6), select the same DataSource again and press the Change DataSource button .
    Check for the filed that you had appended, it will be appeared at the bottom of the extract structure.
    Once this is done now the appended fileds are ready in DS, now we need to populate the data from the corresponding tables.
    For this Select the Data source 0customer_attr --> click on Function enhancement --> enter the project name and next enter the Enhancement RSAP0002 This enhancement has four components that are specific to each of the four types of R/3
    DataSources:
    Transaction data EXIT_SAPLRSAP_001
    Master data attributes EXIT_SAPLRSAP_002
    Master data texts EXIT_SAPLRSAP_003
    Master data hierarchies EXIT_SAPLRSAP_004
    With these four components , any R/3 DataSource can be enhanced suing the above 4 Function module. In this case, you are enhancing a Master data DataSource, so you only need EXIT_SAPLRSAP_002 .
    Next we need ABAP developer in order to enahance the DS and write the logic to populate the values to the filed from the source table.
    once this is done save the code and activate it.
    Next fill the set up tables and  Goto RSA3 tcode check the data source and check for the fileds that were appened are populated with the values or not.
    (for more detailed steps our friend Chowdary has send u the links go through them)
    3) Will it be safe to make a copy of 0CUSTOMER as ZCUSTOMER, add the new attributes in ZCUSTOMER and use ZCUSTOMER for our requirement. In this case also we will need to enhance the extractor.
    I dont think there is a need for creating a new ZCUSTOMER , you can use the standard one.
    Edited by: prashanthk on Aug 13, 2010 9:02 AM

Maybe you are looking for

  • Z77A-GD65 BIOS recovery

    I attempted to update the BIOS to rev A8 (previous version was A6) using M-Flash. The update failed and the board no longer boots from BIOS A Switching to BIOS B lets the board boot properly. How can I repair the A BIOS ? System Config is : MB: Z77A-

  • Unable to Update - Disk cannot be read from or written too

    Every time i got to update the music library onto the IPOD it says "The ipod cannot be updated. The disk could not be read from or written to." I have the newest version of itunes installed and i believe the ipod is up to date. The ipod is recognized

  • How to remove MacProtector

    Man alive!!! Oh My!  I can't believe I've done a really stupid thing!!!  Same thing popped up on my screen. Said I had a lot of viruses . . . . . .clicked on 'remove all'  and then . . . . .I INSTALLED the application MacProtector!   The thing has ru

  • FI Entries during AUC settlement

    Hi We have made the WBS statiscal in our projects and costs are directly collected in AUC. WBS is used for Budget control and its working fine till AUC settlement. During AUC settlement, an credit entry is getting posted to WBS and as a result the As

  • Suggestions for an iSight camera STAND?

    I have the camera... but the little plastic "thingy" that came w/ it doesn't fit on my (achem) Dell monitor. I'd love to just have some sort of little "stand" that sits on my desk, holds it, so I can place it at the BOTTOM of my monitor. I know it's