Enhancment to standard infotype

I have an urgent question.
While mapping to legacy table, they have fields of char 180.
Hence we need to enhance standard Infotype.
However, I like to check if there is any screen design constraint.
Also what is the total length/bytes of an infotype?
How to check?

ECC6.0 enhancement to the infotype is max of 500 btyes ie only 250 chars

Similar Messages

  • Facing problem with call subscreen area in standard infotype

    Dear SAP Guru's,
    I have enhanced standard infotype 0185 from PM01, in assign enhancement tab it create multiple screens ,
    my program name ZP018500, screen number 0200 generated,
    on  0200 screen i need to display two subscreens tfor that
    i have created subscreen area  on srcreen 0200 which is already a subscreen.
    and i am calling two subscreen 0201 and 0202 on that  subscreen area.
    while creating entries for 0185 infotype  my screen keep going in continious loop for call subscreen statement on 0200 screen number.
    roll in fail, session terminated error coming because of this.
    is it correct to create subscreen area on subscreen and calling subscreen on that.
    Guide me to solve the issue.
    Thanks and Regards,
    Syed

    Dear Gopal,
    Thanks for the reply,
    But i can't make 0200 screen as normal screen because it is automatically generated by system while enhancing the standard infotype,
    Please let me know any other solution.
    Regards,
    Syed Taj

  • Showing fields of Custom infotype in standard infotype screen

    Hi Experts
      I have created a custom infotype 9xxx. Now when I go to the PA30 maintenance screen for a standard infotype 0795, i should also see the fields from custom infotype 9xxx. Can you please let me know how I can enhance the standard infotype 0795, since SAP does not allow me to change it directly.
    Thanks
    Neo

    Hi,
    I'm gonna be an *ss and ask why you wanna see the fields of your 9xxx - infotype in SAP IT0795.
    If this is for information purposes, I believe this should be incorporated in reporting and not within master data infotypes.
    Wilfred.

  • Enhance screen for standard infotype

    I need to enhance screen for standard infotype. I follow docs but nothing happens.
    Here is my process by steps:
    1. PM01 - select infty number
    2. PM01 - generating CI_PXXXX (customer include)
    3. create structure for this include
    4. create customer screen for this include
    5. PM01 - generate objects.
    Then I am redirected to SE19 - BAdI-Builder. What should I do follow?
    Created screen hasn't appear in se80 (MPXXXX00).
    Thank you in advance!

    I suggest you place your question in [ERP HCM forum|SAP ERP Human Capital Management (SAP ERP HCM);,

  • Enhance Standard Infotype 1005 in HR

    Dear All,
    Please suggest how to enhance standard infotype 1005 - Planned Compensation in HR.Transcation PM01 is not allowing to do so ...as no CI include is attached for the same.
    Please guide.
    Regards,
    Subhash

    hi,
      maybe you can achieve your requirement by creating a new custom OM infotype
    ( if the custom information are linked to the OM entity :  org unit, positions.. ) or a new PA infotype ( if the custom information are linked to the employee ) .
    Regards luigi
    Edited by: luigi la motta on Sep 2, 2011 11:46 AM

  • Impact of enhancing standard infotypes on service pack upgrade

    Hi SAP experts,
    I have a situation where in we had enhanced standard infotype 14 ( added custom fields to structure CI_P0014) in development systems and moved to production systems. Now these changes should be moved to project system in which the service pack upgrade is in progress. Will it impact the SP upgrade if I move my transports to these systems? Will it overwrite the sp changes for IT14?
    P.S : The support pack was not applied to the system in which the std infotype was enhanced.
    Regards,
    Sameena

    You should re-apply any customer enhancements etc to your development environment after SP's are applied - But only after you have a developer review potential impacts from SP and your development.
    I think you would be fine as IT14 isn't updated often in SP's.
    Cheers,
    Brad

  • Enhancement to a standard infotype

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

  • How copy changes in standard infotype using scc1

    hi,
    i m enhancing standard infotype 0022 adding single field using pm01 .
    changes are showing in our development client in pa30 screen,
    but when i copy the request to other client changes are not reflecting in pa30 screen.
    i checked changed screen layout it is showing that additional field but it is not showing in pa30.
    pls help.
    regards,
    sudhir ghag.
    SAP ABAP HR Consultant.

    Hi ,
    Pls check the entry in V_T582A in 2 different clients.
    This must be missing in other client.
    Transport this table entry.
    Hope this will work.
    Thanks
    Partha.

  • Copy Standard infotype screen for country purpose

    Hi,
    I am trying to copy the Standard screen (2007) for the infotype IT0002 to make some country specific modification.
    However I am not able to copy the standard screen as it is asking for the Access Key.
    Can you please suggest if there is a way to copy the standard infotype screen without providing the access key.
    Regards
    Bharath

    Hi,
    Why don't you just enhance the infotype via PM01 - Enhance single screen?
    (MP000200 screen 2007)
    Regards,
    Dilek
    Edited by: Dilek Ersoz Adak on Feb 8, 2010 6:53 PM

  • HELP CREATING ADDITIONAL FIELDS  WITH  DROPDOWN IN STANDARD INFOTYPE

    HI ALL,
    I AM IN ABAP-HR.
    I HAVE 2 THINGS 2 ASK MY FRIENDZ..
    1). I WANT TO ENHANCE STANDARD INFOTYPE...
    I  WANT TO PUT ADDITINAL FIELD WITH DROPDOWN...
    I CAN PUT ADDITIONAL FIELD BUT I DONT KNOW HOW CAN I DO WITH DROPDOWN...
    2).
    OTHERTHING I WANT TO CHANGE THE TEXTFIELD OF STANDARD INFOTYPE..
    I MEAN 2 SAY CHANGE TEXT 'BIRTHDATE' TO 'DATE'..
    CAN U PLZ HELP ME OUT 4 THIS....
    WAITING 4 FAVOURABLE REPLY..
    BBYE..

    Hello Bhumit,
    1) to check how to bring values to a dropdown please refer the standard demo report programs in se38
    a)DEMO_DROPDOWN_LIST_BOX
    b)demo_dynpro_dropdown_listbox.
    2)We need to understand that if the field label 'BIRTHDATE' is from a standard screen then the approach is to go to that particular screen ...delete the text and put our own text there as 'DATE' ..otherwise if the field is a custom field we can change the name in the field level or domain level
    Pls check,revert and reward if helpful
    Regards
    Byju

  • Changing standard infotypes - HR

    Dear list,
    I have some general questions about changing standard infotypes. Although I am not new to ABAP, I have never touched HR before, and I was thrown into the deep water on a new job (and let me tell you it wasn't easy to get it) So please if you can give me any tips and descriptions about this subject, and I have searched a lot of forums, and only later did I realize that it's a new world out there with ECC6, so here are my questions: Just for background, the client has system ECC6, and it hasn't been upgraded from a previous system. In fact, HR still isn't live, but it will be soon.
    We have system ECC6. Can I use the old way to change standard infotypes?
    If I decide to use the new way, do I first have to decouple the standard infotype?
    How can I tell/know if the standard infotype has already been changed? (Enhanced or just changed)
    In the old way, can you actually change one of the standard fields, or only add new ones?
    In the old way, can your new field be next to the old fields (in the same box or is it a subscreen), or can they only be in an u201CAdditional fieldsu201D box (subscreen).
    Same question for the u201Cnewu201D way.
    I understand that the u201Cnewu201D way is based on the new enhancement concept. Is it complicated to change/enhance the infotype this way, or not so complicated.
    Thank you for your patience,
    BR / MVH
    Allan
    Edited by: Rob Burbank on Feb 20, 2009 9:54 AM
    You cannot edit a post once it has been replied to. Some posters were asking questions (probably of a very basic nature) and then after getting replies, would edit the original question to hide the fact that they were not as knowledgable as they they pretended to be.

    We have system ECC6. Can I use the old way to change standard infotypes?
    You can change the standard infotypes as always(I mean old way)
    How can I tell/know if the standard infotype has already been changed? (Enhanced or just changed)
    Check with the Version management.
    In the old way, can you actually change one of the standard fields, or only add new ones?
    Changing of a field is not allowed. You can add new fields in the CI_include provided
    In the old way, can your new field be next to the old fields (in the same box or is it a subscreen), or can they only be in an u201CAdditional fieldsu201D box (subscreen).
    New fields would be in the subscreen...

  • Enhancing a standard component - Table Cell Variant

    Hi Forum,
    I am trying to enhance the standard WD component /SAPSRM/WDC_UI_SC_DOTC_BD view V_SC_DOTC_BASIC in SRM 7.0 .
    The requierment that for certain condition the Quantity cell in a row should be read only.
    Carried out the following steps:
    1. Created an enhancement
    2. In the standard table column ITEMS_TABLE_QUANTITY  [Columns] , removed the standard inputfield.
    3. Added two cell variants ZITEMS_TABLE_QUANTITY_CV1  [CellVariants]  and ZITEMS_TABLE_QUANTITY_CV2  [CellVariants]  first one contans a text view and second contains inputfield. Variant key for first one is DISPLAY and for second one is EDITABLE.
    4. Enhanced the method WDDOMODIFYVIEW with below code:
    **Read the ITEMS table
      DATA lo_nd_items TYPE REF TO if_wd_context_node.
      DATA lt_items TYPE wd_this->elements_items.
      DATA ls_item LIKE LINE OF lt_items.
      DATA lo_el_context TYPE REF TO if_wd_context_element.
      DATA ls_context TYPE wd_this->element_context.
      DATA lv_disable_quantity TYPE wd_this->element_context-enable_quantity.
      DATA lr_table_column TYPE REF TO cl_wd_table_column.
    ** navigate from <CONTEXT> to <ITEMS> via lead selection
      lo_nd_items = wd_context->path_get_node( path = `COMP_CONTEXT.ITEMS` ).
      lo_nd_items->get_static_attributes_table( IMPORTING table = lt_items ).
      lr_table_column ?= view->get_element( 'ITEMS_TABLE_QUANTITY' ).
      LOOP AT lt_items INTO ls_item .
        IF  ls_item-catalogid EQ 'VEP_Staples_D0'.
          lr_table_column->set_selected_cell_variant( value = 'DISPLAY' ).
        ELSE.
          lr_table_column->set_selected_cell_variant( value = 'EDITABLE' ).
        ENDIF.
      ENDLOOP.
    But even after the condition is true ALL cell i.e. the complete column is DISABLED or when the condition is false the COMPLETE column is enabled instead of enabling disabling ONLY THE SPECIFIC CELL.
    Is there a problem with the code in WDDOMODIFYVIEW or something else?
    Thanks,
    Anubhav

    Hi  Saravanan
    Under ITEMS node I added one more Node(cv_quantity) and one attribute(cell_variant_quantity) with in this node.
    And code in WDDOMODIFYVIEW :
    DATA lo_nd_items TYPE REF TO if_wd_context_node.
      DATA lt_items TYPE wd_this->elements_items.
      DATA ls_item LIKE LINE OF lt_items.
      DATA lo_el_context TYPE REF TO if_wd_context_element.
      DATA ls_context TYPE wd_this->element_context.
      DATA lr_table_column TYPE REF TO cl_wd_table_column.
    ** navigate from <CONTEXT> to <ITEMS> via lead selection
      lo_nd_items = wd_context->path_get_node( path = `COMP_CONTEXT.ITEMS` ).
      lo_nd_items->get_static_attributes_table( IMPORTING table = lt_items ).
      lr_table_column ?= view->get_element( 'ITEMS_TABLE_QUANTITY' ).
      DATA lo_nd_cv_quantity TYPE REF TO if_wd_context_node.
      DATA lo_el_cv_quantity TYPE REF TO if_wd_context_element.
      DATA ls_cv_quantity TYPE wd_this->element_cv_quantity.
    IF first_time EQ abap_true.
      lr_table_column->set_selected_cell_variant( value = 'EDITABLE' ).<--Initially ALL cells shoud be editable
    ELSE.
      lr_table_column->bind_selected_cell_variant( path = 'COMP_CONTEXT.ITEMS.CV_QUANTITY.CELL_VARIANT_QUANTITY' )  .
    * navigate from <CONTEXT> to <CV_QUANTITY> via lead selection
      lo_nd_cv_quantity = wd_context->path_get_node( path = `COMP_CONTEXT.ITEMS.CV_QUANTITY` ).
      IF lo_nd_cv_quantity is BOUND.
      lo_el_cv_quantity = lo_nd_cv_quantity->get_element( ).
          LOOP AT lt_items INTO ls_item .
            IF  ls_item-catalogid EQ 'VEP_Staples_D0' AND ls_item-number_int IS NOT INITIAL AND ls_item-description IS NOT INITIAL.
              lo_el_cv_quantity->set_attribute(
                                                name =  `CELL_VARIANT_QUANTITY`
                                                value = 'DISPLAY' ).
            ELSEIF ls_item-catalogid NE 'VEP_Staples_D0' OR ( ls_item-number_int  IS INITIAL AND ls_item-description IS INITIAL ) ."If the condition is not satisfied OR no item is added to that line
              lo_el_cv_quantity->set_attribute(
                                                name =  `CELL_VARIANT_QUANTITY`
                                                value = 'EDITABLE' ).
            ENDIF.
          ENDLOOP.
    ENDIF.
    ENDIF.
    Now If I add an item that DO NOT satisfy the comdition to be read only, for that row the quantity is enabled but for all the rows below it quantity cells are DISABLED.
    Hope my issue is clear?
    Thanks a lot,
    Anubhav

  • How to enhance the standard search with custom field?

    Hi all,
    I would like to know the general optimal procedure to enhance the standard searches like Opportunity search or Lead search.
    I've gone through some of the threads here. Some suggest, to add the new field using AET and copy the IMPL class of the search and then code the custom logic. Some say, append the new field to the structure of the search object and then implement the BADI.
    I'm actually a bit confused to understand the correct procedure.
    Can someone please help me with a generic procedure to enhance the standard search with a custom field?
    Thanks in advance.

    Hi Maren,
    Once I have got the same development. I have followed the below steps, please check with this. Let me know for further inputs.
      Add new field using Append structure of type ‘XXX’ in search
      Create BADI implementation for Enhancement spot ‘ES_CRM_RF_Q1O_SEARCH’ and include filter ‘BTQOPP’
      Put your logic in BADI implementation – SEARCH method
      Add it in WebUI configuration
      Remove the operator if required
    Regards,
    Swadini Sujanaranjan

  • How to Enhance the Standard Report?

    Hi All,
    How to Enhance the Standard Report? :
    When I am trying to execute the query called ZTIMES in the user group SQ01 it is navigating the screen to selection-screen with some inputs to be given here on the selection screen company code is mandatory as an input. The company code field is having the search help and it is fetching the values for the company code from table called PROJ  Table (Project definition Table).But I want the company code should fetch the value from the  PRPS Table ( Work break structure(WBS Element) Level).
    Tables used are PROJ and PRPS.
    The company code in PROJ is PROJ-VBUKR
                                    In PRPS is PRPS-PBUKR
    In the coding part related to that selection screen I have to replace PROJ-VBUKR with
    PRPS-PBUKR.But it is standard report to enhance.
    What is suggestible solution for this issue?
    Thanks,
    M Raju

    Hi,
    Since this is an ABAP Query, You can change the infoset query in SQ02 and establish the join linkages between PROJ and PRPS
    Also on the selection screen of the Query make sure you provide company code from PRPS table and report output also from the same table reference.
    Once you have modified the ABAP Query, activate and generate it so that it will internally regenerate the a standard program.
    http://help.sap.com/erp2005_ehp_02/helpdata/en/d2/cb4256455611d189710000e8322d00/frameset.htm
    ABAP Query (Sq01)Modification
    Hope this helps
    Regards,
    Shiva

  • Adding Standard Infotype fields to Custom Infotype

    Hi,
    I have a Requirement where I've created a Custom Infotype. Now, client needs to add Standard KOSTL and Email Address fileds to it. Whenever, someone tries to create / change this Custom Infotype for any Employee, the Pernr's  KOSTL and Email Address should get populated automatically as in Standard Infotypes 0001 and 0105.
    Please guide me, how to achieve this functionality.
    Regards,
    Hems.

    Hi Salman,
    Thank you for your valuable information. I haven't Configured Dynamic Actions yet. Is it simple to write the Logic for Dynamic Actions. Is this the only way to solve this Issue?
    I tried by adding the standard fields, but they are not populating the values; but just appearing as Input Fields with Input help option.
    Please let me know if you have any suggestion in this direction?
    Regards,
    Hems.

Maybe you are looking for

  • Attribute does not appear in WEBUI document properties windows

    I've created a classObject using the xml parser of Ifs' WEBUI: <?xml version="1.0" standalone="yes"?> <ClassObject> <Name>ArquivoXsl</Name> <Superclass RefType="Name">Document</Superclass> <Description>Classe de Teste do arquivo de layout de Faturas<

  • Error message "the document iweb could not be saved"

    Help! I made a few small updates to my already published web site and now when I go to save or publish it I get the message "The document iWeb could not be saved". I have made changes in the past with no issues.... why now and what is the problem? Th

  • J2EE at Os level...

    Hello, How can I make sure that J2EE is running? It is regarding ABAP+J2EE for BW 3.5 NW04. I went to SMICM - Services and it will show the list of HTTP ports and there status. How will I be sure that J2EE is active. Because J2EE will be down but the

  • DSL with AP Express, and three computers

    Hey All, I am having a problem obtaining an IP on my WinXP computer with an Airport Express base station. I have a MacBook pro and an iPhone that is connecting fine to the A.P., but the XP box is unable to have an IP assigned to it. I'm not sure wher

  • CRIO-9215 et acquisition de plusieurs voies avec NI Datalogger

    Acquisition avec un NI cRIO-9215 et NI Datalogger : Cette acquisition est-elle uniquement compatible avec NI-DAQmx-Base ? Est-elle possible avec VI-Logger, SignalExpress ? (J'ai sur ce même poste de travail NI-DAQmx) Utilisation de NI-Datalogger : La