Enquiry on HP Fiber Transciever Module Compatibility.
I have a Cisco switch 2960-s PoE installed.
I was wondering if the HP Fiber module #AJ718A ( http://h30094.www3.hp.com/product/sku/3790470 ) is compatible with it.
if it is compatible, is there much difference between it and the cisco GLC-SX-MM ?
thank you
I was wondering if the HP Fiber module #AJ718A ( http://h30094.www3.hp.com/product/sku/3790470 ) is compatible with it.
No it won't. You insert this SFP into a Cisco 2960S and the port will go into "err-disable" until you remove it.
is there much difference between it and the cisco GLC-SX-MM ?
Not much difference. There are only a few SFP manufacturers that supply components to bigger manufacturers like HP and Cisco. The difference is that Cisco has inserted an algo into the Cisco-branded SFP's IDPROM. The appliance will interrogate the component and if the hash values extracted from the IDPROM don't match, then the port goes into "err-disable".
Similar Messages
-
MACSec over dark fiber - transceiver module option?
Dear all,
Want to order two WS-C3750X-24T-S with service modules C3KX-SM-10G in order to implement MACSec between two datacenters using dark fiber (one fiber). Distance between datacenters is about 17 Km.
Can I use GLC-EX-SMD module on both location?
Thanks in advance,Hi Marvin,
Thanks for the response,
Actually I'm little bit confused because ISP fiber engineer explain to me that since there is single fiber optic between two datacenters he suggest me to use GLC-BX40-D-I in one side and GLC-BX40-U-I in other side. This is because GLC-BX40-D-I 1550nm for TX and 1310 for RX and viceversa for GLC-BX40-U-I. In other hand GLC-EX-SMD operates only on range 1310nm and this module will be installed in both sides.
Based on cisco docs GLC-BX40-D-I and GLC-BX40-U-I not supported in 3750X.
I just want to be sure if it will work for sure in my environment?
BR
Enis -
Cisco IE-3000 8TC doesn't recogze 4SM fiber sfp module
Have a few Cisco IE-3000 8TC switches with the 4SM FIber SFP expansion modules. The switches do not discover these ports at all. I'm assuming that thhere is a fix or firmware upgrade, would appreciate any help.
Isgabrillo, Please see below.
I wasn't able to see a PID for the SFP's, but they are Cisco GLC-FE-100LX
THe switch doesn't seem to recognize the 4SM module that is currently attached. As I stated, I have a few already installed in the field that I am not able to contact right now, but have the same issue. I think I read in a blog somewhere that someone had the same issue and there was an IOS update that cured it.
Switch#sh inv
NAME: "1", DESCR: "IE-3000-8TC"
PID: IE-3000-8TC , VID: V03 , SN: FOC1826Y36B
NAME: "IE-3000-8TC - Module in slot 1", DESCR: "IE-3000-8TC - Module in slot 1"
PID: IE-3000-8TC , VID: V03 , SN: FOC1826Y36B
Switch#dir flash
%Error opening flash:/flash (No such file or directory)
Switch#sh version
Cisco IOS Software, IES Software (IES-LANBASEK9-M), Version 12.2(58)SE2, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2011 by Cisco Systems, Inc.
Compiled Thu 21-Jul-11 00:59 by prod_rel_team
ROM: Bootstrap program is Xmen2 boot loader
BOOTLDR: IES Boot Loader (IES-HBOOT-M) Version 12.2(44r)EX5, RELEASE SOFTWARE (fc1)
Switch uptime is 4 minutes
System returned to ROM by power-on
System image file is "flash:/ies-lanbasek9-mz.122-58.SE2/ies-lanbasek9-mz.122-58.SE2.bin"
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
[email protected].
cisco IE-3000-8TC (PowerPC405) processor (revision S0) with 131072K bytes of memory.
Processor board ID FOC1826Y36B
Last reset from power-on
1 Virtual Ethernet interface
8 FastEthernet interfaces
2 Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
64K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 50:67:AE:72:AE:00
Motherboard assembly number : 73-15595-01
Motherboard serial number : FOC18258RWT
Model revision number : S0
Motherboard revision number : A0
Model number : IE-3000-8TC
System serial number : FOC1826Y36B
Top Assembly Part Number : 800-28538-03
Top Assembly Revision Number : A0
Version ID : V03
CLEI Code Number : CMMFE00ARB
Hardware Board Revision Number : 0x02
CIP Serial Number : 0x8E72AE00
SKU Brand Name : Cisco
Switch Ports Model SW Version SW Image
* 1 10 IE-3000-8TC 12.2(58)SE2 IES-LANBASEK9-M
Configuration register is 0xF
Switch#exit
Switch#dir flash:
Directory of flash:/
736 -rwx 3096 Mar 1 1993 00:00:55 +00:00 multiple-fs
2 drwx 1024 Mar 1 1993 00:06:38 +00:00 ies-lanbasek9-mz.122-58.SE2
732 -rwx 676 Mar 1 1993 00:07:33 +00:00 vlan.dat
733 -rwx 1915 Mar 1 1993 00:00:58 +00:00 private-config.text
735 -rwx 1424 Mar 1 1993 00:00:58 +00:00 config.text
64094208 bytes total (45407744 bytes free)
Switch#exit -
2811 service module compatability
Hi,
Will a Cisco NM-2FE2W Network Module work in a 2811 router and if so what are the commands to set it up? I know how to setup T1 controllers but is this the same or similar or what? (presuming the module will work?)
Thanks!Hi,
The 2811 does not support NM-2FE2W module. See table-3 in this link:
http://www.cisco.com/c/en/us/products/collateral/routers/2800-series-integrated-services-routers-isr/prod_qas0900aecd80169bd6.html
HTH -
OID and BPA Suite (publisher module) Compatibility?
I'd like to know if BPA Suite Publisher can use the OID/SSO as user repository and provide security.
Our idea is to publish this module through Oracle Portal.
Best regards.
Edited by: [email protected] on Oct 10, 2008 10:11 AMhttp://download.oracle.com/otn/nt/ias/101340/Oracle_BusinessProcessPublisher_QuickStartGuide.pdf
In this PDF, Page 10 has an article on How to configure LDAP user management for business publisher,
Hope this helps.
Cheers :) -
C series module compatibility with 9103 Chassis
Hi All,
I have a 9004 cRIO controller and a 9103 cRIO Chassis.
I want to use a 9239 or 9229 and a 9225 module for developing my application.
Can anyone tell whether these modules are compatible with my existing Controller and Chassis.
Regards,
CooldudeThose modules are all compoatible with your hardware. The more important question is if they are compatible with the version of LV and NI-RIO you are using. I believe those modules all work with LV 8.5.1, NI-RIO 2.4.0, and any version later than that.
-
10 Gig Module compatibility cause LMS Alert
Hello dears,
In one of our customer site, Dual 6509-E switch with VSS mode working fine so far but now when they tried to connect the IBM Blade chassis to the switch using Fiber media PLRXPL-SC-SX3-C1 in IBM Blade chassis side and X2-10GB-SR in core switch side getting the below LMS alerts. Can any one help me to resolve this issue.
From:
[email protected]
mailto:[email protected]
Sent: Tuesday, September 10, 2013 12:43 AM
To: Edwin
Subject: 0002ZDP ; 172.17.0.1 ; Tue 10-Sep-2013 00:42:29 AST ; Critical ; OutOfRange ; Active ;
EVENT ID = 0002ZDP
TIME = Tue 10-Sep-2013 00:42:29 AST
STATUS = Active
SEVERITY = Critical
MANAGED OBJECT = 172.17.0.1
MANAGED OBJECT TYPE = Switches and Hubs
EVENT DESCRIPTION = OutOfRange::Component=VOLT-172.17.0.1/10070 [Te1/4/5 Supply Voltage Sensor];ComponentClass=VoltageSensor;ComponentEventCode=1080;HighThreshold=5.0;Status=OK;CurrentValue=0.0;LowThreshold=1.0;entSensorValue=0;RelativeVoltageThreshold=0.0 %;
NOTIFICATION ORIGINATOR = Fault Management ModuleHi Hook,
It could be a false alarm , you can try delete and re-add the device in DFM alone.
1.3.6.1.4.1.9.9.109.1.1.1.1.3.1 , you can do a direct SNMP WALK on this OID and see what
values you get.
Thanks-
Afroz
[Do rate the useful post]
****Ratings Encourages Contributors **** -
X-Fi I/O module compatibility
I'm thinking of upgrading my X-fi platinum Fatalty champion series (witch has the X-Fi I/O module) and I wonder if that module is compatible with the X-fi titanium proffesional series, or do I have to buy the champion series with theX-Fi I/O module?
Rawlitz wrote:
I'm thinking of upgrading my X-fi platinum Fatalty champion series (witch has the X-Fi I/O module) and I wonder if that module is compatible with the X-fi titanium proffesional series, or do I have to buy the champion series with theX-Fi I/O module?
In addition, the I/O module of the Elite Pro does not work with Windows 7. So it would be useless for you to buy it. Creative seems unable or unwilling to deli'ver proper dirvers for this high end sound card.
Under Windows 7 this high end sound card is not a champion, it's performance is comparable to a 30 $ sound card. Do not waste your money. -
Mixed 3750G and 3850-X stack and Netfow module compatibility
Anyone doing this?
I can seem to find any documentation regarding a mixed stack AND a netflow module.
If you have a pure 3750-X stack you can run the module in any switch - it doesn't need to be the master. But what if half the switches are 3750's and half are 3750-X's?
Can it still read the flows of the older 3750's?Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
Just wanted to mention when you mix original StackWise with StackWisePlus, StackWisePlus falls back to StackWise mode. I.e. you lose some of the "Plus" features. -
Hello everyone,
I got a network with Siemens Scalance XR300M switches, and I got to do an optical connection to a Catalyst 3750 (3750G-24TS-1U).
The Siemens has a Gigabit Interface with SC Ports over SMF@1310nm (10 km module).
Which GBIC module should I use to connect both of them?
I looked at cisco.com and I saw only one SFP@1310 GBIC module (GLC-EX-SMD). But it is for longer distances!! (I suppose that a SMF@1300nm module will not be compatible with the SMF@1310nm in the Siemens Switch, right?)
Thanks in advance for your help!
Best regards,
Fabioviyuan700 is correct is what he says.
The Cisco GLC-LH-SM transceiver will interface with your Siemen's Gigabit Ethernet 10km SMF interface. The actual IEEE 802.3 spec for Gigabit Ethernet 1000BASE-LX outlines a transmit and receive wavelength range of 1270 to 1355 nm; which covers both 1300 and 1310nm. Look at Section 38.4 - PMD to MDI optical specifications for 1000BASE-LX for the specifications.
The data sheet posted on Cisco's website (link below) indicates the GLC-LH-SM= is 1310nm.
Cisco Gigabit Ethernet SFP Data Sheet
<http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6577/product_data_sheet0900aecd8033f885.html>
Sometimes vendors used 1300nm as a designation for MMF interface and 1310nm for SMF. Probably a reason but I don't know why.
I hope this helps! Let us know if you have any other questions.
Tom -
SCXI different Modules Compatability
I am using a SXCI 1000 (4-slot) chassis with one SCXI-1100 module and 3 SCXI-1102 modules. I want to know if I can multiplex a SCXI-1100 moudule with a SCXI-1102 module to one pulg in DAQ board and the other two SCXI-1102 modules into another plug in DAQ board, eventhough all moudles are housed in the same chassis.
Dunty,
Please refer to the following Knowledge Base article for more information.
Can I Use SCXI Modules in Parallel Mode and Multiplexed Mode in the Same Chassis?
http://digital.ni.com/public.nsf/websearch/C94797073B74E51E86256A93005CABFF?OpenDocument
In your situation you are asking to run all four modules in multiplexed mode with two of them being the controlers. Therefore you will have two groups and this is not possible. If you decide to multiplex the SCXI-1100 module with a SCXI-1102 module to one DAQ board then you will have two modules left over. You could set both remaining SCXI-1102 modules to parallel mode or you could set one to parallel mode and multiplex the last module with the first SCXI-1100 and 1102.
Regards,
Justin Britten
Ap
plications Engineer
National Instruments -
MSI Bluetooth Module compatibility
hey
i have a KT3-ARU and together with it a MSI Bluetooth Module(MS-6967).
I was hoping to upgrade to a K7n2-ILSR but would like to know if the module would work with the new board if i reconfigured the wires to the correct pins???
thanksd/l the manual see if they have the connector ,my nforce 2 has one
http://www.msi.com.tw/program/products/mainboard/mbd/pro_mbd_detail.php?UID=528 -
Sfp-ge-s= is it compatable with a glc-sx-mm
Could I have a sfp-ge-s= on one side of a multimode fiber link and a glc-sx-mm= on the other side of the link and you were within the correct distance from each other. Will they talk to each other if they are the same wavelength. Is there a chart somewhere interfaces will work with each other and what won't.
ThanksHi,
I don't know of a chart that shows which transceivers are compatible with each other, but the transceivers you mention are both 1000BASE-X transceivers using 850nm wavelength on mulitmode fibre so should have no issues.
From the Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix:
SFP-GE-S= 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, extended operating temperature range and DOM support, dual LC/PC connector
GLC-SX-MM= 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength, dual LC/PC connector
Regards -
X2-10GB-LRM to SFP-10G-SR= Compatibility
Hi,
Can you help me in this ?
I have two 10Gig modules.
On 6500, i have X2-10GB-LRM and on 3750-x i have SFP-10G-SR= .
you can use it with fiber cable and patch cord to connect the two devices?
thanksHello,
SFP-10G-SR is a MMF and it uses a LC duplex connector.
X2-10GB-LRM is also a MMF and it uses LC duplex connector.
so they are compatible.
Link
Under 6xxx series switches you will both transceivers as part of the supported devices.
http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matri/OL_6974.html#wp99798
Under 3xxx series switches:
http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matri/OL_6974.html#wp48759
Link for 10GBASE X2 modules:
http://www.cisco.com/en/US/prod/collateral/modules/ps5455/ps6574/product_data_sheet0900aecd801f92aa.html
10 transceiver modules compatibility matrix:
http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6974.html
Look for Table 1 10-Gigabit Ethernet Transceiver Module Models
Thank,
Haihua -
hi, our team ran into a problem about fiber optic connectivity. The part of FPGA is k7325tffg676-2 ,and the tool is ISE 14.6. We found that far-end loopback failed, but the neear-end PMA loopback passed. Does this mean that part on the FPGA work correctly (the failure is caused by fiber-optic-modules or fiber cable )? Besides, we're not sure that in the neear-end PMA loopback mode , which point does data streams turn back? point 1 or point 2? thanks in advance.
hi, yenigal. tks for your answer. We now want to narrow down the the cause of failure.
Could the success of the neear-end PMA loopback guarantee our code (generated by coregen) is right ?
If so, we will check our board, and what point should we take care of ?
thanks again.
Maybe you are looking for
-
How do I copy a voice memo to a cd
How do I copy a voice memo in itunes to a cd?
-
Retina Graphics Card Switching under Windows 7
Does anyone know of a tool that would allow me to switch graphics cards in Windows 7? I believe having such a tool would greatly improve battery life since I will only used Windows 7 for work. Thanks!
-
Displaying both pixel and inch dimesnsion in the Info Panel
Anybody else constantly switching the Info Panel from displaying inches to pixels and vice versa? How to avoid having to do this? I either want to see one or the other, somtimes being able to see both simultaneously would be nice. While dragging out
-
WHy SAP PI Needs different server then R/3
I am new to SAP PI. I have following queries:- 1. Why cannot we install sap pi so same server as that of sap r/3. 2. What are the server requirements for installation of SAP PI 7.4 dual stack. request gurus to put some light on these two queries. Tha
-
Where are my contacts, calender etc ?
I am using Palm Desktop 4 on my Vista machine. I seem to have lost some of my contacts. Since I back up everynight online I have the data, but I can not seem to find it. I sure would appreciate the help. I have done this before, but I can not remembe