EPM Architect  failed to start.

Hi all,
My validation report gives me a Failed status for EPMA Service
FAILED PMAJ: EPMA Service Check if jobmanager service available
Error: com.hyperion.cis.utils.BadResponseCodeException: Bad response code: 500
Recommended Action: Check application is started 2 s
FAILED PMAP: EPMA Service Check if processmanager service available
Error: com.hyperion.cis.utils.BadResponseCodeException: Bad response code: 500
Recommended Action: Check application is started
As said on validation report i tried to start the job manager and process manager but it gave me below messages
"Tha Hyperion EPM Architect - _Process Manager_ service on local Computer started and then stopped. Some services stop automatically if they have no work to do, for example, the Performance Logs and Alerts service."
"The Hyperion EPM Architect - _Job Manager_ service on local Computer started and then stopped. Some services stop automatically if they have no work to do, for example, the Performance Logs and Alerts service.
Thanks in advance.
Edited by: user8819264 on Mar 4, 2011 7:26 AM

An update .. My Event Viewer says
Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Cannot initialize the Session Manager. ---> System.Exception: System.Data.OracleClient requires Oracle client software version 8.1.7 or greater.
at System.Data.OracleClient.OCI.DetermineClientVersion()
at System.Data.OracleClient.OracleInternalConnection.OpenOnLocalTransaction(String userName, String password, String serverName, Boolean integratedSecurity, Boolean unicode, Boolean omitOracleConnectionName)
at System.Data.OracleClient.OracleInternalConnection..ctor(OracleConnectionString connectionOptions)
at System.Data.OracleClient.OracleConnectionFactory.CreateConnection(DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningObject)
at System.Data.ProviderBase.DbConnectionFactory.CreatePooledConnection(DbConnection owningConnection, DbConnectionPool pool, DbConnectionOptions options)
at System.Data.ProviderBase.DbConnectionPool.CreateObject(DbConnection owningOb...
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
My database version is Oracle Database 10g Enterprise Edition Release 10.2.0.4.0. Operating system is Win 2003 32 bit. What is the version of client do i need to install and can any body send me the link where i can download it.
Thanks

Similar Messages

  • Hyperion EPM Architect Services not starting

    Hi All,
    We have installed Oracle Hyperion 11.1.1.1. We are using Sql 2005 as RDBMS. The problem that I am facing is that Hyperion EPM Architect services are not starting. For Hyperion EPM Architect - Process Manager I am getting the following error in the event viewer:
    Event Type:     Error
    Event Source:     HyS9BPMA_ProcessManager
    Event Category:     None
    Event ID:     0
    Description:
    Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Cannot initialize the Session Manager. ---> Hyperion.DataAccessLayerCore.DataAccessLayerException: Database connectivity could not be established. ---> System.Data.SqlClient.SqlException: An error has occurred while establishing a connection to the server. When connecting to SQL Server 2005, this failure may be caused by the fact that under the default settings SQL Server does not allow remote connections. (provider: TCP Provider, error: 0 - No connection could be made because the target machine actively refused it.)
    at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
    at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
    at System.Data.SqlClient.TdsParser.Connect(Boolean& useFailoverPartner, Boolean& failoverDemandDone, String host, String failoverPartner, String protocol, SqlInternalConnectionTds connHandler, Int64 timerExpire, Boo...
    It looks like that Sql Server 2005 is refusing connection. I checked 'Allow remote connections' property for sql 2005 and it is enabled. Any help would be appreciated.
    Thanks in advance,
    Amol

    Hi,
    Yeah the Sql Server 2005 is running on the same server
    Hyperion Foundation
    PASSED Configuration Check whether all configuration tasks have been completed 0 s
    FAILED Database Connection to database
    Error: java.net.UnknownHostException: VPC-W3K\HYPERIONEPM: VPC-W3K\HYPERIONEPM
    Recommended Action: 0 s
    Financial Management
    FAILED Configuration Check whether all configuration tasks have been completed
    Error: Next tasks are not configured:
    clusterRegister: Configuration Failed
    Recommended Action: Try to configure mentioned tasks 0 s
    FAILED HFM Application Server Configuration HFM Application Server failed...
    Error: Error Configure Application server
    Recommended Action: Check application is started 204 s
    FAILED HFM WebServer HFMWebServer startup... failed...
    Error: java.net.ConnectException: Connection refused: connect
    Recommended Action: Check application is started 204 s
    FAILED LCMServer LCMServer startup failed...
    Error: java.net.ConnectException: Connection refused: connect
    Recommended Action: Check application is started 204 s
    FAILED SmartViewServer SmartView WebServer startup failed...
    Error: java.net.ConnectException: Connection refused: connect
    Recommended Action: Check application is started 0 s
    Foundation / Performance Management Architect
    FAILED EPMA DimensionServer Server Configuration EPMADimensionServer startup... failed...
    Error: java.net.ConnectException: Connection refused: connect
    Recommended Action: Check application is started 12 s
    This is what I got from the diagnostic.
    Regards,
    AD

  • S9 EPM Architect Process Manager fails to start.

    Hi All,
         I just tried doing Hyperion System9 installation and am encountering a problem.
         The Problem is, Installations are all done and the Configuration also seems to be
         fine as i get to know from seeing the Configuration utility window, but once i am done with
         configuring the Performance Management Architect, i tried starting the
         Hyperion S9 EPM Architect Process Manager and it was not starting,even i tried increasing the
         timeout setting for the startup of the dimension Server in the BPMA_Server_Config.xml file.Still
         it failed in starting..
         Other than all the steps mentioned in the doc,Few steps i skipped during the Planning Installation was,
         1.I didnt check the Activate instance option while creating the Planning Instance
         2.I didnt Increase the Heap Size of App Server.
         So could someone please suggest on what is creating the Problem during the startup.

    Hi,
    For more detailed information on why it is not starting have a look in windows event log. In windows go to administrative tools > event viewer > application
    Double click HyS9BPMA_ProcessManager and there should be a more detailed description in the window.
    e.g. Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Process Manager could not start because database connectivity could not be established. --->
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Not able to start EPM Architect Process Manager.

    I have installed Hyperion 11.1.1.3 and when i am trying to start the EPM Architect Process Manager Service i am getting the below error message.
    The Hyperion EPM Architect - ProcessManager service on local Computer started and then stopped
    Some services stop automatically if they have no work to do, for example, the performance Logs and Alerts Service.
    I have also checked the Event Viewer and the below is what is logged into the event viewer.
    Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Cannot initialize the Session Manager. ---> System.InvalidOperationException: Attempt to load Oracle client libraries threw BadImageFormatException. This problem will occur when running in 64 bit mode with the 32 bit Oracle client components installed. ---> System.BadImageFormatException: An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B)
    at System.Data.Common.UnsafeNativeMethods.OCILobCopy2(IntPtr svchp, IntPtr errhp, IntPtr dst_locp, IntPtr src_locp, UInt64 amount, UInt64 dst_offset, UInt64 src_offset)
    at System.Data.OracleClient.OCI.DetermineClientVersion()
    --- End of inner exception stack trace ---
    at System.Data.OracleClient.OCI.DetermineClientVersion()
    at System.Data.OracleClient.OracleInternalConnection.OpenOnLocalTransaction(String userName, String password, String serverName, Boolean integratedSecurity, Boolean unicode, Boolean omitOracleConnectionName)
    I have also tried to start Hyperion EPM Architect - .Net JNI Bridge which i am able to start sucessfully howerver when i try to start the EPM Architect - Process manager i am getting the above error.
    I have also tried to directly login into http://localhost:19091/awb and i am getting the below error.
    Loading the Module 'awb.appcontainer' failed
    Kindly help me out.

    Hello, I have found the solution in my environment.
    All Hyperion softwares will run on a x64 bit OS with x64 bit Oraclle client installed except FDM. I tried to run everything through Oracle x32 bit client and everything worked except EPMA, I received errors in the eventvwr that stated it could not run against a x32 bit Client. On my FDM server (w2k3 x64 bit) I had to install Oracle x32 bit client in order for me to get my FDM server fully functional.
    thank you.

  • Cannot Start EPM Architect Process Manager after a Power Failure

    Hey All,
    We had a power failure in the office last night/this morning. We have two environments, and luckily, our production environment seems to be working OK, however, on our development environment, we cannot get the EPM Architect Process Manager to start (or any of the associated services).
    Here is what we have tried already:
    - Restarting the server
    - Restarting all services in the correct order
    - Running EPM System Configurator for Performance Management Architect > Configure Database (the first time, we just re-used the same tables, and had the same error. We did it a second time and dropped the tables and were able to get the service (and all other EPMA services) to start, but we couldn't get into the Application or Dimension Library.
    - Restoring the EPMA DB schema from backup from two nights ago - same error when trying to restart the service.
    We are running 11.1.1.3 (04 patches for Planning and CalcManager, but not EPMA). We are running MS SQL 2005 for the relational databases.
    Error message when restarting the service:
    "The Hyperion EPM Architect - Process Manager service on Local Computer started and then stopped. Some services stop automatically..."
    When we go to the event viewer, it tells us:
    Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Dimension Server started but failed to initialize on machine CSHMISHYPTST. Check the error log on that machine.
    at Hyperion.DimensionServer.ProcessManager.EngineManager.StartEngine(Machine machine, EngineType engineType)
    at Hyperion.DimensionServer.ProcessManager.EngineManager.InitializeReadWriteEngine()
    at Hyperion.DimensionServer.ProcessManager.EngineManager.Load()
    at Hyperion.DimensionServer.ProcessManager.ProcessManager.Initialize()
    at Hyperion.DimensionServer.ProcessManager.Service.OnStart(String[] args)
    at System.ServiceProcess.ServiceBase.ServiceQueuedMainCallback(Object state)
    Went into D:\Hyperion\logs\epma and looked at the "dimension_server.log":
    2010-09-21 12:45:08,939 [Engine Startup] Hyperion.DimensionServer.Program.LogMessage(:0) - An error occurred during initialization of engine ID 1: Object reference not set to an instance of an object..
    System.NullReferenceException: Object reference not set to an instance of an object.
    at Hyperion.DimensionServer.RelationshipMemberList.Add(RelationshipMember item)
    at Hyperion.DimensionServer.Dimension.<LoadSharedMembers>b__11(RelationshipRecord relationship)
    at Hyperion.DataAccessLayerCore.DALRowset`1.Read()
    at Hyperion.DataAccessLayerCore.SelectCommand`1.Execute(Action`1 callback)
    at Hyperion.DataAccessLayerCore.GenericDAO.Select[T](Action`1 callback, SetParamsEvent`1 onSetParams)
    at Hyperion.DimensionServer.DAO.DimensionDAO.LoadRelationships(Int32 libraryID, Int32 dimensionID, Boolean primary, Action`1 action)
    at Hyperion.DimensionServer.DAO.DimensionDAO.LoadSharedMembers(Int32 libraryID, Int32 dimensionID, Action`1 action)
    at Hyperion.DimensionServer.Dimension.LoadSharedMembers()
    at Hyperion.DimensionServer.Dimension.LoadMembers()
    at Hyperion.DimensionServer.Library.Load()
    at Hyperion.DimensionServer.Global.Initialize(String jobManagerConnectString)
    at Hyperion.DimensionServer.Program.Main(String[] args)
    Looking for some suggestions or ideas. Have tried searching the forums and Google, but haven't had any success.

    Ironically I just got alerted by Oracle that EPMA patch 03 had been pulled from the MOS site and replaced by patch 04.
    You are receiving this notification because our records indicate that you have downloaded Oracle Hyperion Enterprise Performance Management Architect 11.1.1.3.03 Service Fix – Patch 9650100.
    Please be advised that Oracle Hyperion Enterprise Performance Management Architect 11.1.1.3.03 Service Fix - Patch 9650100 has been removed from My Oracle Support and is superseded by Oracle Hyperion Enterprise Performance Management Architect 11.1.1.3.04 Service Pack – Patch 9800827.
    Patch 9650100 is now obsolete and you should use Oracle Hyperion Enterprise Performance Management Architect 11.1.1.3.04 Service Pack - Patch 9800827, which corrects file packaging issues, from My Oracle Support (https://support.oracle.com) instead.
    Please thoroughly review the Readme for Oracle Hyperion Enterprise Performance Management Architect 11.1.1.3.04 Service Pack - Patch 9800827 prior to implementing.
    Best regards,
    Chris

  • Couldn't start Hyperion EPM Architect - Process Manager

    Hi,
    I Couldn't start EPM Architect - Process Manager because of which unable to launch Dimension Library, Application Library and Calc Manager from Workspace.
    This services starts rest dependent services but it stops in one or two minutes states status as 'starting'.
    I am on Windows 2003 R2, Hyperion 11.1.1.3, MSSQL 2005
    Regards
    Kumar

    'Hyperion EPM Architect - Process Manager' service doesn't start automatically as it supposed to. I do start it manually then it starts saying "starting" for a minute or two then stops itself, and bunch of other dependent services stop along with it as well.
    Event Viewer has below error related to the service
    +Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Dimension Server started but failed to initialize on machine xxxx.  Check the error log on that machine.
    at Hyperion.DimensionServer.ProcessManager.EngineManager.StartEngine(Machine machine, EngineType engineType)
    at Hyperion.DimensionServer.ProcessManager.EngineManager.InitializeReadWriteEngine()
    at Hyperion.DimensionServer.ProcessManager.EngineManager.Load()
    at Hyperion.DimensionServer.ProcessManager.ProcessManager.Initialize()
    at Hyperion.DimensionServer.ProcessManager.Service.OnStart(String[] args)
    at System.ServiceProcess.ServiceBase.ServiceQueuedMainCallback(Object state)
    For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.+
    ALTER DATABASE MYDBNAME SET READ_COMMITTED_SNAPSHOT ON; ran query and waited for 15 minutes, it looks like didn't complete, keeps on displaying "Executing query", I've stopped.
    ALTER DATABASE MYDBNAME SET ALLOW_SNAPSHOT_ISOLATION ON; completed successfully.
    It still has same error.
    Regards

  • Hyperion S9 EPM Architect Process Manager Service Fails

    Hello All,
    I am fairly new with working on Hyperion. I have installed Hyperion Planning 9.3 on my local machine that runs on Windows XP. I am usning SQL Server 2005 as my database. I am having difficulty getting the EPM Process Manager Architect to start. It fails to start and when I look in the event viewer it displays the following error message:
    [Engine Startup] FATAL An error occurred during initialization of engine ID 1: Invalid object name 'DS_Property_list'..Exception: System.Data.SqlClient.SqlException
    Message: Invalid object name 'DS_Property_list'.
    Source: .Net SqlClient Data Provider
    at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection)
    at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
    at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
    at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
    at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
    at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async)
    at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result)
    at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(DbAsyncResult result, String methodName, Boolean sendToPipe)
    at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()
    at Hyperion.DataAccessLayerCore.DataAccessLayer.ExecWriteSQL(Boolean CanWrite, String SQL, Action`1 onAddParams)
    at Hyperion.DimensionServer.DAO.PropertyManagerDAO.ClearPropertyAllowedValues(Int32 propertyID)
    at Hyperion.DimensionServer.PropertyManager.UpdatePropertyAllowedValues(Property property, IList`1 allowedValues)
    at Hyperion.DimensionServer.ProductRegistration.ParsePropertyDefinition(XPathNavigator nav)
    at Hyperion.DimensionServer.ProductRegistration.ParsePropertyCategory(XPathNavigator nav, ApplicationClass appClass)
    at Hyperion.DimensionServer.ProductRegistration.ParseApplicationClass(XPathNavigator nav, String fileName, XmlDocument doc)
    at Hyperion.DimensionServer.ProductRegistration.ParseProduct(String fileName, Boolean fileMustExist)
    at Hyperion.DimensionServer.Program.Main(String[] args)
    For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
    Has anyone come across an issue such as this? The rest of my processes start/stop as expected, but the EPM Process Manager does not. Any quidance or information as to how this can be resolved would be greatly appreciated. Thank you.
    Corey

    Hi am having same issue. The error is
    ervice cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Process Manager could not start because database connectivity could not be established. ---> System.Data.SqlClient.SqlException: Login failed for user 'windowsAuthentication'.
    at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
    at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
    at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
    at System.Data.SqlClient.SqlInternalConnectionTds.CompleteLogin(Boolean enlistOK)
    at System.Data.SqlClient.SqlInternalConnectionTds.AttemptOneLogin(ServerInfo serverInfo, String newPassword, Boolean ignoreSniOpenTimeout, Int64 timerExpire, SqlConnection owningObject)
    at System.Data.SqlClient.SqlInternalConnectionTds.LoginNoFailover(String host, String newPassword,...
    Please any body can help on this.

  • Unable to start Hyperion EPM Architect - Process Manager after upgrade

    Hi All,
    I'm unable to start Hyperion EPM Architect - Process Manager after upgrading from EPMA 11.1.1.3.0 to 11.1.1.3.03. I get the following error in the Event Viewer.
    Service cannot be started. Hyperion.DimensionServer.ProcessManager.Interface.ProcessManagerException: Cannot initialize the Session Manager. ---> Hyperion.DataAccessLayerCore.DataAccessLayerException: Database version mismatch:  Hyperion.SessionManager schema version is 9.5.0.0.0.10,  database schema version is 9.5.0.0.9.1.
    at Hyperion.DataAccessLayerCore.DataAccessLayer..ctor(NameValueCollection settings, String tablePrefix, String baseNamespace, String schemaVersion)
    at Hyperion.SessionManager.DAO.SessionManagerDataAccessLayer..ctor(NameValueCollection settings)
    at Hyperion.DimensionServer.SessionManager.SessionStoreRdbms.Initialize(String rdbmsVendor, String rdbmsConnParams, Int32 rdbmsCommandTimeout)
    at Hyperion.DimensionServer.SessionManager.SessionManager.Initialize(String jvmPath, String classPath, String ctgLibPath, String cssConnInfo, String hubHost, String hubPort, Boolean enableNestedGroups, String rdbmsVendor, String rdbmsConnParams, Int32 rdbmsCommandTimeout, Boolean restorePastInstanceSessions, Boolean ...
    I've run through all the steps of patching EPMA ran the Oracle_Upgrade 9.5.0.0.0.10 to 9.5.0.0.9.1.sql script per the patch readme. But can't figure out where it's pulling the schema version number from. Any ideas?
    Thanks,
    Chuck

    Hi,
    you forgot to update the EPMA database. Last step in patching is:
    Now, you must run the database upgrade script before starting the process manager.
    Run the single database upgrade script that corresponds to your database vendor.
    Oracle_Upgrade 9.5.0.0.0.10 to 9.5.0.0.9.1.sql
    SQL_Server_Upgrade 9.5.0.0.0.10 to 9.5.0.0.9.1.sql
    DB2_Upgrade 9.5.0.0.0.10 to 9.5.0.0.9.1.sql
    The scripts are located in the following directory:
    %HYPERION_HOME%\OPatch\EPMA_11_1_1_3_01\files\products\Foundation\BPMA\Server\conf\
    hope that helps.

  • Not able to Start Hyperion EPM Architect services

    Hi,
    I have been facing issues with accessing FDM web application. The Error Desc is " An exception occured during the execution of the current web request. Please contact the administrator to review the stac trace in the event log for more information about the error."
    So we have tried to stop/restarted the Hyperion Services in Prod FDM server. But we are not able to start the below services after the stopping the services.
    Hyperion EPM Architect - Web Application
    Hyperion EPM Architect - Process Manager
    Hyperion EPM Architect - Job Manager
    Hyperion EPM Architect - Event Manager
    Hyperion EPM Architect - Engine Manager
    Hyperion EPM Architect - .Net JNI Bridge
    Also, we have rebooted the server. But these services are not up after the reboot. Please could you help to resolve this issue.
    Thanks,
    Aravindh K

    Thanks John. I got help from Oracle Support team to resolve the issue. This is a Common issue with the 11.1.1.3 version, the services take some time and Sometime start once before the other hence the issue. The issue is resolved after restarting the services manually in order.

  • EPM 11.1.2 - epmsystem Configuration Manager service fails to start

    OracleEpmSystemc_oracle_middleware_user_projects_epmsystem1ConfigurationManager fails to start. I do not know how I am getting affected because everything else works fine. I have Essbase , Studio, Planning, EAS installed and all of them work fine. Do not know why this service fails. This is a fresh install of EPM 11.1.2 on windows 2003.
    The Event Viewer says "The OracleEpmSystemc_oracle_middleware_user_projects_epmsystem1ConfigurationManager service failed to start due to the following error:
    The service did not respond to the start or control request in a timely fashion. "
    Thanks
    Edited by: 823489 on Dec 24, 2010 6:25 AM

    Hi,
    have you found a fix for this ?
    I'm getting the same error.
    Thanks,
    Cyril

  • Issue starting Hyperion S9 EPM Architect Process Manager

    Hi All,
    When i try to start " Hyperion S9 EPM Architect Process Manager", I am getting message
    "The Hyperion S9 EPM Architect Process Manager service on Local Computer started and then stopped". What may be the reason for this?
    I have installed this on win xp and on oracle 11.
    please let me know your suggestions.
    Thanks,
    Vikash

    Hi,
    Your problem is you have installed it on XP, this is not a suported OS and EPMA does not work well with it.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Transform classic to EPM architect error in version 11.1.2.1

    When trying to use the "transform classic to epm architect" in 11.1.2.1 the application is not being converted and giving "parsing" errors. When removing the Job ID in the job filter options and opening ID 27 under Entity kickouts, the background one message states ---- Input line ';;;;;;;;;;;' does not have expected format of 11 columns -----

    1.Check if your backend database or schema are running & try to connect your database or schema with the user id and password which is being for configuration
    2.Stop the essbase server
    3.Restart the essbase server
    4.Go to Task manager then see whether essbase.exe appear.
    5.if so then try to login into essbase server with your user id and password
    6.or else check  if the oracle process manager is getting starting and  for the below logs
    For eg
    d:\oracle\Middleware\user_projects\diagnostics\logs\OPMN\opmn\console~Essbase1~EssbaseAgent~AGENT~1.log
    Thanks,
    Sreekumar Hariharan

  • HYPERION S9 EPM ARCHITECT PROCESS MANAGER ERROR!

    Hi There
    I have problem while starting Hyperion s9 EPM Architect process manager its giving error while startingup services
    The HYPERION S9 epm architect process manager service on local computer started and then stopped.Some services stop automatically if they have no work to do,for example,the performance logs and alerts service.
    Thanks
    HV

    Hello,
    I am also have the same issue with my install. The EPM Architect Process Manager errors out with the following message:
    Service cannot be started. System.InvalidOperationException: Cannot start service HyS9BPMA_JobManager on computer 'BIGDADDY'. ---> System.ComponentModel.Win32Exception: The service did not respond to the start or control request in a timely fashion
    --- End of inner exception stack trace ---
    at System.ServiceProcess.ServiceController.Start(String[] args)
    at Hyperion.DimensionServer.ProcessManager.ProcessManager.StartJobManager()
    at Hyperion.DimensionServer.ProcessManager.ProcessManager.Initialize()
    at Hyperion.DimensionServer.ProcessManager.Service.OnStart(String[] args)
    at System.ServiceProcess.ServiceBase.ServiceQueuedMainCallback(Object state)
    For more information, see Help and Support Center at
    Any Ideas as to how to fix this? I've tried increasing the timeout variable, but the process errors out in less than 10 seconds so i don't think that is an issue. Any additional help would be greatly appreciated. Thank you.
    Corey

  • Error: EPM Architect on Shared Services Console

    Hi,
    While accessing the EPM Architect on Shared Services Console, I found the below error message:
    "Error: Unable to connect to "EPM Architect", ensure that the application is up and running and the user has the appropriate rights to access this feature."
    I tried to resolve the error and referred John's reply for the thread Not able to start my Hyperion EPM Architect -Process Manager it very urgent But no luck.
    Environment: Win 2003 SP2, SQL Server, Installed 11.1.2 EPM.
    Regards,
    Naveen
    Edited by: Naveen on Apr 6, 2011 5:20 AM

    I found the solution for my issue.

  • EPM Architect - Missing Data Source when deploy

    Hi,
    I have an application on EPM which status is at the moment Not Deployed. It once worked but now when I try to deploy it's Data Source is missing, nor i can associate one to it. How can I recover this situation? The application was working until yesterday and the Data Source for the underlying application is present.
    The Diagnostic does not show me the option to find suitable datasource for this application.
    The Planning application works correctly, I tried to restart Planning and EPMA Services but without success.
    Is there something I can do working on the tables in the EPMA schema?
    Thank you,
    bidi

    Hi Celvin,
    no I didn't play with the underlying tables. I ran the Diagnostic and it fails two tests:
    - Not deployed but in Shared Services
         - a) Delete from EPMA only
         - b) Manually delete application from Shared Services
    - Not Deployed status in EPMA, but in product
         - a) Delete from EPMA only. May run the Transform Classic to EPM Architect Wizard manually aftwrwards
         - b) Manually delete the application from the productnd
    I think that Delete from EPMA and reverse from the underlying planning application would in a certain sense "fix" my issue, but I'm not so confident in this operation, I don't want for some reason override something on the Planning application.
    In the forum I found that when the Data Source is set to NONE the diagnostic is able to recognize a data source that could fit. I don't know if in that case NONE is "NONE" as a string or is just missing, in my case I see an empty drop down list.
    Thanks

Maybe you are looking for

  • New Hard drive - won't install windows from recovery disc

    I am having an issue with my Satellite L505D-S5965.  I replaced the hard drive (upgraded from 250 to 500GB) due to issues with the old one (which had been replaced once already) and am using the recovery disc I made before my other hard drive crashed

  • Saving PDFs as PostScript files-need shortcut

    My workflow requires me to save PDFs as PostScript files. Can I set up Preferences or create a keyboard shortcut in Acrobat that will let me bypass the "Save As" dialog box? I haven't been able to find a way to do this and it would save me tons of ti

  • Any updated to iOS 7.1 with a 5s; how did it go?

    Hi all, I have been waiting and watching to see if there have been any issues with updating to iOS 7.1 with an iPhone 5s. In the past, I have gotten burned with updating my iPad to a newer iOS namely poorer battery life, etc. Our iPhones are only two

  • XCode and recent versions of Subversion

    Hi everyone. I'm having problems using XCode 3.1's SCM integration with my hosting company's SVN version 1.5.2. I've heard people say that XCode won't work with SVN 1.4+, but I'm not sure if that's actually true. After filling out the SCM section of

  • Does version 3.6 still have the plugin-container.exe?

    Plugin-container.exe causes me massive problems with hangs, crashes, cpu usage in the 90-100% range and it seems to force the cooling fan to run at maximum constantly. It makes the computer useless as anything other than an extremely noisy paperweigh