Equal logic Storage not Integrating with SCVMM 2012 R2

Hi,
I am using Equal logic 6210 with firmware 7.0. I also installed Hit Kit 4.7 on my SCVMM servers (in High Availability Cluster) and direct access to my ISCSi san subnet.
I am facing issue in adding storage to my SCVMM 2012 R2, after running below commands i am able to see Storage Proivder in SCVMM but no success in adding storage in Array tab of scvmm.
Please guide me , see attached screen shots
Import-Module -Name 'C:\Program Files\EqualLogic\bin\EqlPSTools.dll'
New-EqlGroupAccess -GroupName Group -GroupWKAddress 192.168.1.5 -MgmtWKAddress 10.1.1.5 -UserName grpadmin -Password testpwd 
Update-StorageProviderCache
Import-SCStorageProvider
Afzal Munir
<ADMIN NOTE: Phone number removed per privacy policy>

Hi Kevin
I am struggling with the same thing during bare metal installs of Hyper-V hosts. In my case I have managed to narrow it down to the language settings in the oobe pass. If I include them, parsing of the unattend file halts (without an explicit error anywhere)
and the host fails to join the domain. Could you try to leave out the language settings in oobe pass and see if it then completes as expected? Would be interesting to see if it actually is the same issue with a slightly different flavour :)
EDIT: Got a bit further now with the new release of WS2012 R2. All the testing I've done has been with the 05182 build. Stumbled across KB2913316 which stated that a new build (31419) was released december 11th. Allthough the KB does not directly apply to our
issue I thought I'd give it a go, so I went about building a new vhdx-image. Low and behold - the first test went smoothly applying all the settings in the unattend file! I'm going to continue testing to make sure the successful run wasn't just a fluke.

Similar Messages

  • Error 10218 while integrating scom 2012 r2 with scvmm 2012 r2

     hello,
    We are working to integrate the SCOM 2012 R2 With SCVMM 2012 R2 .But while creating connection of integration it got failed with error in job on scvmm as below :
    Error (10218)
    Setup could not import the System Center Virtual Machine Manager Management Pack into Operations Manager server because one or more required management packs are missing. The VMM Management Packs cannot be deployed unless the following component management
    packs are present in Operations Manager :
    Windows Server Internet Information Services 2003,
    Windows Server 2008 Internet Information Services 7,
    Windows Server Internet Information Services Library,
    SQL Server Core Library.
    Recommended Action
    To provide the missing component management packs, ensure that the following management packs have been imported into Operations Manager server:
     Microsoft Windows Server 2003 Internet Information Services Management Pack for OpsMgr 2012 (version 6.0.6278.0 or later)
     Microsoft SQL Server 2005 Management Pack(version 6.0.5000.0 or later)
     You can download the management packs from the System Center Operations Manager Catalog at http://go.microsoft.com/fwlink/?LinkId=86411 
    Reference link used :-  http://technet.microsoft.com/en-us/library/hh882396.aspx ,We have imported all the required MPs as mention in above link on scom.
    Regards
    Richa KM

    Have you imported all of the packs it mentions:
    Windows Server Internet Information Services 2003,
    Windows Server 2008 Internet Information Services 7,
    Windows Server Internet Information Services Library,
    SQL Server Core Library.
    There's a good walkthrough
    here which details all the pre-reqs.
    It was some time ago but i also did a walk-through with pictures
    http://myopsmgrblog.wordpress.com/2013/04/23/scom-integration-with-scvmm/
    Hope this helps

  • OS-Deployment to virtual servers with SCVMM 2012 R2 vs SCCM 2012 R2 or integration with both?

    Hi,
    OS-Deployment to virtual servers with SCVMM 2012 R2 vs SCCM 2012 R2 or integration with both?
    Is SCCM just for physical servers, and SCVMM for virtual?
    What are benefits of integrating them?
    /SaiTech

    Hi,
    Please refer to the links below:
    Introduction to Configuration Manager
    http://technet.microsoft.com/en-us/library/gg682140.aspx
    Virtual Machine Manager
    http://technet.microsoft.com/en-us/library/gg610610.aspx
    The System Center 2012 Integration Guide provides information about automating each of the System Center components and integrating them with each other and with other systems and applications.
    For more information, see the
    System Center 2012 Integration Guide.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • TS2565 I have just installed logic pro  Version 9.1.1 to my new mac book , purchased in 2012 December. I am now being told my version of logic is not compatible with my version of OS X. Help!!!

    I have just installed logic pro  Version 9.1.1 to my new mac book , purchased in 2012 December. I am now being told my version of logic is not compatible with my version of OS X. Help!!! What can I do. I tried upgrding the logic pro software but this didn't help. It still won't open.
    Many thanks

    How did you install Logic onto your new Mac Book?
    From the App store or from the DVD boxed set?
    If it was downloaded from the App store then it should already be v9.1.8... and if it isn't you need to call Apple to help you sort this out.
    If it was originally from the DVD boxed set then you must update using software updates....
    If software updates cannot find Logic to update it then you either have...
    Renamed the Logic Pro app in which case rename it back to Logic Pro
    or
    The Logic Pro App is not in the applications folder which is where it needs to be to be updated... so move it back there.

  • Deploy VMs with SCVMM 2012 R2 with Internet connection

    Hello everyone,
    I am trying to use SCVMM 2012 R2 to create a network that will eventually hold 2 clouds, but for the moment I can't seem to create the network and connect the VMs to the Internet.
    My lab is this (all hosts are in a LAN, 192.168.0.0/24, gateway 192.168.0.1, and ONLY ONE NIC per HOST ):
    1 host DC, DNS, SQL, SCVMM 2012 R2 (IP 192.168.0.8)
    2 hosts with Hyper-V (IP 192.168.0.9 and 192.168.0.10)
    I'm also planning to create some "virtual" networks for clustering and live migration, which will use the same physical NICs as the management network (since I have only one physical NIC per host).
    Could you please give me a quick guide of how to set this up with SCVMM 2012 R2, so that I can take advantage of the new features (network virtualization, logical networks, logical switch) and for the VMs to be able to reach the Internet?!
    Thank you so much.  

    Thanks for the reply.
    My network architecture is exactly like the one described on your paper, with 2 differences:
    1. I only have one host in the Production group and one host in the Gateway group
    2. The first host has one physical NIC, the second host has 2 NICs, one internal and one with an Internet (routable) IP
    After applying the logical switches on the hosts, I lost Internet connectivity on the gateway host (I have no idea why there is no logical Gateway Switch !!!). VMM completed the jobs with no error.
    Any thoughts?

  • Remote WSUS integration with SCCM 2012

    Hi,
    We are currently having WSUS already in place for Patching , but not used at all its just installed.
    can remote WSUS be integrated with SCCM 2012 server which is on different server ? what is the best practice ? is it to have WSUS on same server as Primary server?
    or I decommission it and install a new WSUS on same server as SCCM server.
    what steps have to be taken care if remote WSUS is integrated ? any documents or steps to be taken care .
    Thanks in Advance

    When you install SUPs, they automatically configure the underlying WSUS instance to sync from an upstream server based upon your ConfigMgr hierarchy.
    A couple of notes here though:
    - You generally shouldn't use an existing instance of WSUS for ConfigMgr. Once integrated into ConfigMgr, WSUS should no longer manage approvals, update binary downloads, or update binary distribution as these are all handled by ConfigMgr separate from WSUS.
    Using an existing WSUS instance where this was the case can be problematic at best and will cause unexpected behavior and results.
    - Clients do not choose SUPs based upon boundaries or location so using a remote SUP is typically not beneficial and in many cases will cause additional network load. The exception to this is if the SUP is within a secondary site.
    Jason | http://blog.configmgrftw.com | @jasonsandys

  • The problem with forecast reports in SCOM 2012 after integration with VMM 2012

    Hello.
    I have problem with forecast reports in SCOM 2012 after integration with VMM 2012. All other reports (not forecasting) works fine. For example, report “Host Group Forecasting” don’t work. The report is generated, but I have error: “Subreport
    could not be shown”. I find only errors in SQL Server Reporting logs like this:
    library!ReportServer_0-13!1758!06/26/2012-18:26:23:: i INFO: RenderForNewSession('/Microsoft.SystemCenter.VirtualMachineManager.2012.Reports/Microsoft.SystemCenter.VirtualMachineManager.2012.Report.ForecastHostGroup')
    processing!ReportServer_0-13!1758!06/26/2012-18:26:28:: e ERROR: Throwing Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: , Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Не удалось выполнить
    запрос для набора данных "DiskSpaceUsageForecasting". ---> Microsoft.AnalysisServices.AdomdClient.AdomdErrorResponseException: Execution of the managed stored procedure GetTimeSeriesForecast failed with the following error: Exception has been thrown by
    the target of an invocation..
    Query (5, 58) Parser: The syntax for '6' is incorrect.
       at Microsoft.AnalysisServices.AdomdClient.AdomdConnection.XmlaClientProvider.Microsoft.AnalysisServices.AdomdClient.IExecuteProvider.ExecuteTabular(CommandBehavior behavior, ICommandContentProvider contentProvider,
    AdomdPropertyCollection commandProperties, IDataParameterCollection parameters)
       at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.System.Data.IDbCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.ReportingServices.DataExtensions.AdoMdCommand.ExecuteReader(CommandBehavior behavior)
       at Microsoft.ReportingServices.OnDemandProcessing.RuntimeDataSet.RunEmbeddedQuery(Boolean& readerExtensionsSupported, Boolean& readerFieldProperties, List`1 queryParams, Object[] paramValues)
       --- End of inner exception stack trace ---;
    The Russian string “Не удалось
    выполнить запрос для набора данных "DiskSpaceUsageForecasting"” is translated to “Could not execute query for data set "DiskSpaceUsageForecasting"”.
    I have clean installation SCOM 2012 RU1, VMM 2012 RU1. Integration SCOM with VMM work fine.
    SQL collation for all SQL DB instances (SCOM and VMM and SCOM reporting) – “SQL_Latin1_General_CP1_CI_AS”
    SQL Analysis service: SQL collation – “Latin1_General” ; language for the server – English (United States)
    I think the problem in regional settings. By my opinion there are two possible mistakes:
    SQL collation  for all SQL DB instances. May be need use “Latin1_General_CI_AS”
    as provided by
    http://blogs.technet.com/b/momteam/archive/2012/05/25/clarification-on-sql-server-collation-requirements-for-system-center-2012.aspx
    Need change regional setting. Question is for what (OS regional setting, SQL Analysis service settings,…) ?

    Error: Subreport could not be shown
    Opening a report for Client Security might result in the following error being displayed in one or more areas of the report: "Error: Subreport could not be shown."
    Background
    There are two possible reasons for this error:
    1. Wrong location   The reporting server is pointing to the wrong computer running SQL Server or a SQL Server instance.
    2. Insufficient permissions   The account configured (in SQL Server Reporting Services) to connect to the reporting database does not have appropriate permissions for the database.
    Solution
    To determine which reason is causing the error, attempt to directly open the subreport reporting the error, by clicking the name of the subreport.
    If the reporting server is pointing to a wrong location, the report displays an error similar to the following: 
    Error message
    An error has occurred during report processing.
    Cannot create a connection to data source 'SystemCenterReporting'. Cannot open database "SystemCenterReporting" requested by the login. The login failed. Login failed for user username.
    To verify the correct SQL Server computer and instance path
    In Report Manager, navigate to the report generating the error and click the Properties tab.
    Click Data Sources and under a Shared data source, note the path.
    Open the reporting Web site. If you chose the default virtual directory for reports, the URL is: http://hostname/Reports/
    If you chose to secure the viewing of reports with HTTPS, the URL is: https://hostname/Reports/
    Click SCDW.
    In the Connection type list, ensure that Microsoft SQL Server is selected.
    In the Connection string box, ensure that the correct SQL Server computer and instance name are entered.
    Note:
    A period (.) denotes the local computer.
    If the account has insufficient permissions, the report displays an error similar to the following: 
    Error message
    An error has occurred during report processing. (rsProcessingAborted) Query execution failed for data set 'DSDashboardComputersTrend'. (rsErrorExecutingCommand) EXECUTE permission denied on object 'prSAS_UX_DashboardComputersTrend', database 'SystemCenterReporting',
    schema 'dbo'.
    To determine if you are experiencing the SQL Server permissions issue
    Open the reporting Web site. If you chose the default virtual directory for reports, the URL is:http://hostname/Reportserver/
    If you chose to secure the viewing of reports with HTTPS, the URL is:https://hostname/Reportserver/
    Click Microsoft Operations Manager Reporting, click Microsoft Forefront Client Security, and scroll to DashboardComputersTrend.
    Click DashboardComputersTrend.
    If you are experiencing a SQL Server permissions issue, an error similar to the preceding error appears.
    To grant permissions to the SQL Server computer
    1. In Report Manager, click SCDW and note the account in the Connect using section. This is the account under which the database is contacted.
    2. On the server with the System Center Reporting database, start SQL Server Management Studio.
    3. In the tree, expand Security, and then expand Logins. Do one of the following:
    If the user account is listed, right-click the account, click Properties, and then go to step 5.
    If the user account is not listed, right-click Logins and choose New Login.
    4. In the Login name box, enter the user account (domain\username).
    5. In the Login Properties dialog box, click User Mapping, and then under Users mapped to this login, select the System Center Reporting check box.
    6. Under Database role membership for: System Center Reporting, select the db_owner check box, and then click OK.
    Thanks,
    Yog Li
    TechNet Community Support

  • Some error of COM when I launch Validated configuration before create cluster on hyper-v 2012 with SCVMM 2012 SP1

    Hi everybody,
    I tried to created a cluster with 2 hyper-v Standalone 2012 ( with ISCSI connectivity for the SAN) with scvmm 2012 sp1.
    After the validation testing I have 2 errors and I don't find the answer . I pasted the log at the bottom.
    Thanks for your help.
    Bye.
    An error occurred while executing the test.
    An error occurred while validating the operating system software updates.
    One or more errors occurred.
    Unable to cast COM object of type 'System.__ComObject' to interface type 'MS.Internal.ServerClusters.Validation.IClusterUpdate'.
     This operation failed because the QueryInterface call on the COM component for the
    interface with IID '{E3C9B851-C442-432B-8FC6-A7FAAFC09D3B}' failed due to the following error: No such interface
    supported (Exception from HRESULT: 0x80004002 (E_NOINTERFACE)).
    ===============================================================================================================================
    An error occurred while executing the test.
    There was an error initializing the network tests.
    There was an error creating the server side agent (CPrepSrv).
    Unable to cast COM object of type 'System.__ComObject' to interface type 'MS.Internal.ServerClusters.Validation.IClusterNetwork2'.
     This operation failed because the QueryInterface call on the COM component for
    the interface with IID '{2931C32C-F731-4C56-9FEB-3D5F1C5E72BF}' failed due to the following error: No such interface
    supported (Exception from HRESULT: 0x80004002 (E_NOINTERFACE)).

    Hi Guillaume Pincon,
    Please first update both server to latest update and turn off the Windows firewall for narrow down this issue then try build the cluster again, one of the cluster create condition is all the servers should have the same software updates (patches) and service
    packs. If all above steps not work please post the second validation error information.
    The related KB:
    Hyper-V: Using Hyper-V and Failover Clustering
    https://technet.microsoft.com/en-us/library/cc732181(v=ws.10).aspx
    I’m glad to be of help to you!
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • OEM integration with SCOM 2012

    Hi, 
    Can anyone help me out on the topic- OEM integration with SCOM 2012.

    Are you refer to this document
    Oracle® Enterprise Manager Installation and Configuration Guide for Microsoft System Center Operations Manager Connector
    http://docs.oracle.com/cd/E24628_01/install.121/e28572.pdf
    Roger

  • Isolated Lab on Hyper-V (Prod) with SCVMM 2012 R2

    Hello,
    I currently would like to make littla test lab on my Hyper-V 2012 R2 with SCVMM 2012 R2 at work.
    Knowing that there is DC in prod on this Hyper-V, I would like to isolate the lab from the prod without loosing internet access.
    I did try with a server gateway but no connectivity and a lot of errors.
    It is so easy to do witout VMM that I can't understand why it is so difficult now.
    Please let me know.
    Ollie

    You should create a new virtual switch of the type "internal" where the VMs can communicate with the hosts through this switch, and vice versa. Then it will be isolated from the production DC.
    -kn
    Kristian (Virtualization and some coffee: http://kristiannese.blogspot.com )

  • Live Migration between two WS2012 R2 Clusters with SCVMM 2012 R2 creates multiple objects on Cluster

    Hi,
    I'm seeing an issue when migrating VM's between two 2012 R2 Hyper-V Clusters, using VMM 2012 R2, that have their Storage provided by a 4 Node Scale Out File Server Cluster that the two clusters share.
    A migration between the two clusters is successful and the VM is operation but I'm left with two roles added to the cluster the VM has moved to instead of the expected one.
    For example: Say I have a VM that was created on cluster A with SCVMM, resulting in a name of : "SCVMM Test-01 Resources"
    I then do a live migration to Cluster B which has access to the same storage and then I end up with two new roles instead of one.
    "SCVMM abw-app-fl-01 Resources" and "abw-app-fl-01"
    The "SCVMM abw-app-fl-01 Resources" is left in an unknown state and "abw-app-fl-01" is operational.
    I can safely delete "SCVMM abw-app-fl-01 Resources" and everything still works but it looks like something is failing during the process.
    Has anyone else seen this?
    I'll probably have one of my guys open a support ticket in the new year but was wondering if anyone else is seeing this.
    Kind regards,
    Jas :)

    In my case the VMs where created in VMM in my one and only Hyper-V cluster (that's been created and is managed by VMM).
    All Higly Available VM:s have a FCM role named "SCVMM vmname" where vmname is the name if the VM in VMM. On top of that a lot
    of VM:s, but not all,  have a second role name named vmname. Lots of name in that sentence.
    All VMs that have duplicates are using the role named vmname.
    I thought it had to do with whether a VM had been migrated so I took one that never had been migrated and did. It did not get a duplicate.
    Is there any progress on this?

  • RoboHelp 10 not integrating with TFS 2102

    Hi all,
    I'm trying to integrate RoboHelp 10 with TFS 2012 so I can use source control through it.
    I've run through this tutorial: http://www.adobe.com/devnet/robohelp/articles/robohelp-tfs-integration.html but when I go to click "Add to Version Control", I don't see TFS as a version control provider. All I get is RoboHelp SharePoint Connector.
    I've also tried modifying my registry following this topic: http://helpx.adobe.com/robohelp/kb/registry-settings-microsoft-team-foundation.html but I get the same results using that.
    I can access the TFS server through Visual Studio's Team Explorer, and I've mapped my project folder through Team Explorer's Source Control Explorer.
    I'm not sure what else I can do at this point.
    Any help anyone can provide on the matter would be appreciated.

    I'm looking for a solution but my problem is slightly different. I'm running Visual Studio 2012 (update 4) and RH10.  When I installed the 32 bit MSSCCI Provider, the TFS option became available (the 64 bit provider was ignored).  Now I get an error on check-in citing "Trouble with TFS power tools".  The details says there was an "Error loading the Changeset Comments Policy policy".  I have tried installing both the 2010 and 2012 TFS Power Tools (combinations of one, the other, both) but still get the same error.
    Thanks!
    Thomas

  • Unattend.xml parsing/merging issue with SCVMM 2012 R2

    Hi all
    I have a problem with a new install of SCVMM 2012 R2. I have created templates for 2008 R2, 2012 and 2012 R2. I have an issue with the unattend.xml losing some of its configuration when the 2012 and 2012 R2 templates are built, this issue however doesn't
    occur on a 2008 R2 template build.
    I have generated unattend.xml files for all 3 OS's using System Image Manager in the latest AIK using the original install.wim from each OS media.
    In the unattend.xml file I have specified language settings, and a few other bits but the issue I have is when I configure autologon with local admin and password. I specify a logon count of 1, I also specify a GUIRunOnce command in SCVMM and not the answerfile.
    The problem is the resulting merged unattend.xml has a logon count of 999 and no GUIRunOnce command. I have tried different variations where I specify GUIRunOnce in the xml and not SCVMM, applying the autologon to the Template or Guest OS profile and
    all end with the resulting xml with logon count of 999 and no GUIRunOnce. If I remove the autologon part then GUIRunOnce gets parsed and works correctly.
    As mentioned this only happens with Server 2012 and 2012 R2, 2008 R2 works correctly.
    Any ideas?

    Hi Kevin
    I am struggling with the same thing during bare metal installs of Hyper-V hosts. In my case I have managed to narrow it down to the language settings in the oobe pass. If I include them, parsing of the unattend file halts (without an explicit error anywhere)
    and the host fails to join the domain. Could you try to leave out the language settings in oobe pass and see if it then completes as expected? Would be interesting to see if it actually is the same issue with a slightly different flavour :)
    EDIT: Got a bit further now with the new release of WS2012 R2. All the testing I've done has been with the 05182 build. Stumbled across KB2913316 which stated that a new build (31419) was released december 11th. Allthough the KB does not directly apply to our
    issue I thought I'd give it a go, so I went about building a new vhdx-image. Low and behold - the first test went smoothly applying all the settings in the unattend file! I'm going to continue testing to make sure the successful run wasn't just a fluke.

  • Airwatch MDM integration with sccm 2012

    I want to integrate Airwatch MDM with SCCM 2012 SP1. I am not able to find out any documentation for the same. Can anybody help me with the said.
    Thanks and Regards Deepak

    There is an integration between AirWatch and ConfigMgr 2012. I've never used it so I can't comment on it.
    https://tool.microsoftsca.com/Partner/?id=737
    Watch the video here
    http://airwatch.wistia.com/medias/7463a8aae8
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

  • VLAN ID not shown in SCVMM 2012 R2

    After upgrading to SCVMM 2012 R2 (from SCVMM 2012 SP1)
    The VLAN ID isn't showing anymore, i know its still there because its showing in Hyper-V Manager.
    When you change the VLAN ID it does apply the settings (i can verify in Hyper-V manager) but it still does not show it.
    Hyper-V Host: Windows 2008 R2
    SCVMM Host:  Windows 2012 R2
    Using the combination SCVMM 2012 R2 and Hyper-V 2012 R2 there is no issue and it shows the VLAN ID.

    Hello,
    When you're trying to check the network configuration using VMM powershell commands, does it shows the vLan id or not ?
    ipmo virtualmachinemanager
    Get-SCVirtualMachine -Name <yourvm> | Get-SCVirtualNetworkAdapter
    #or
    (Get-SCVirtualMachine -Name <yourvm> | Get-SCVirtualNetworkAdapter).VLanID
    If so, the issue is only related to the GUI console (I have seen that with some network-related features in RTM of VMMR2, but was working in Powershell).
    For those who gets issues with Live-Migrations in R2, can you try to perform the same using powershell ?
    ipmo virtualmachinemanager
    $VM = Get-SCVirtualMachine -Name <yourVM>
    $VMHost = Get-SCVMHost -Name <yourhyperv>
    Move-SCVirtualMachine -VM $VM -VMHost $VMHost
    Hope this can help as workaround.
    Guillaume

Maybe you are looking for

  • App Server Problem Logging off the Windows User...

    I installed the AppServer 9PE on a Windows 2003 machine as a service...usually I access the machine using Remote Desktop (to avoid CED freezing), the problem is that when I logoff the user to disconnect the RD session...the java.exe launched by the a

  • I would like to uninstall iPhoto completely; MBP 2010, Yosemite

    Hey guys. Noob here; please forgive. I'm at the point where I can't deal with the excess photos that iPhoto is creating.  It's only going to get worse as I approach 17,000 photos.  I've been using iPhoto and Lightroom, but I just don't want to deal w

  • Oracle 10g in Solairs 10 vs Windwos 2003

    Hi We are planning to install oracle 10g, due to buget limit, we may buy wintel machine to install oracle DB, the DB around 300G, I want to know that the performance on Solairs 10 is better ? or windows 2003(64bit) still ok to handle the large DB? If

  • HT4623 how can i update my ipod 1.1.5 to 2.0

    my ipod does not have ability to load apps as it is currently running 1.1.5, how can i upgrade to 2.0?

  • Ix4-300d cannot create shares

    HI All We recently purchased an ix4-300d to backup file on. I set a static IP and connected to the web interface. When I try to create a share, I get this error: The selected function is not available due to the state of the pools I tried updating th