Error 10452 using DAQCard 6024E

When I try to run a .vi that get data from a sensor... I get error 10452 and it says 'no interupt is available for use.' I am using a HP Pavillion zd7000 laptop in a WinXP environment. I have attempted changing the IRQ to no avail... has anyone had a similar problem and figured out a solution?

THe best thing to do is to check to see what IRQ is currently assigned to your DAQCard, and determine if any other devices in your system are also using that same IRQ. If there is a conflict, then the problems you described will occur. Ways to resolve it include disabling or changing the IRQ of the other conflicting device to another IRQ value, or changing the IRQ your DAQCard is using to a value which is currently unused.
The following thread discusses a similar issue and gives suggestions:
http://forums.ni.com/ni/board/message?board.id=250&message.id=5394
I am curious, which IRQ values have you attempted to use thus far with no luck ?

Similar Messages

  • Convert elements using DAQCard-6024E to USB-6221using LabVIEW 2009

    I just received an old project, the VI was mainly designed using DAQCard-6024E. Since we'd upgrade the equipment, and the DAQCard-6024E is no long used. However, they want to keep the similar front panel. I am trying to convert the pull-down menu that I can use with USB-6221 with Windows 7, but I don't know how. Can anyone help?
    Windows 7, NI USB-6221,  LabVIEW 2009 sp1
    Solved!
    Go to Solution.
    Attachments:
    test_1.vi ‏45 KB

    Hi smoothengine007,
    You should be able to use this document's Digital Output section to see how to modify your VI:
    Transition from Traditional NI-DAQ to NI-DAQmx in LabVIEW
    It looks like the rest of your code can stay intact if you just replace your Traditional DAQ VIs with DAQmx VIs. 
    Regards,
    Message Edited by Dustin D on 02-23-2010 11:59 AM
    Dustin D

  • "Error -10452 occurred at AI singlescan, no interrupt level available for use."

    AI sample channel (single point waveform).vi
    Error -10452 occurred at AI singlescan.
    Possible reasons:
    NI-DAQ LV: No interrupt level available for use.
    I have configured 2 virtual channels to use AI chn0 and chn1 in Measurment and Automation explorer, but I get error -10452 in the test panel.

    SS 01,
    In order to better troubleshoot this error, can you tell me what board you are using, what operating system you have, and what versions of NI-DAQ and LabVIEW you have installed?
    Have a great day.

  • AI Control gives error: 10452 occurred at AI control. Possible reasons: NI-DAQ LV no interrupt level is available for use.

    How can I run out of interrupts while accessing my DAQPad? Does
    the community have troubleshooting suggestions?

    You don't say which DAQpad. If this is a device on your parallel port then
    you will need to make sure that the parallel port has an interrupt assigned
    and not just a base address.
    Check out the following from the NI Knowledgebase:
    http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/bf7960eb90
    ef882a8625654e007d8b1a?OpenDocument
    Ian
    "Riverside Consulting, LLC" wrote in message
    news:[email protected]..
    > AI Control gives error: 10452 occurred at AI control. Possible
    > reasons: NI-DAQ LV no interrupt level is available for use.
    >
    > How can I run out of interrupts while accessing my DAQPad? Does
    > the community have troubleshooting suggestions?

  • Are there compatibil​ity issues with using labview 4.0.1 with a DAQCARD 6024E. Which Ni-daq version should I use? Operating system?

    I recently purchased a DAQCard 6024E and am trying to set it up on a windows XP laptop. Labview 4.0.1 vis do not seem to function. Do I have some compatibility issues? Thanks

    Hello;
    The oldest version of NI-DAQ that supports that card of yours is 6.6, which doesn't support Labview 4. Furthermore, the only NI-DAQ version that supports windows XP is the latest one, 6.9.2, and the Labview version that supports that same OS is 6.1.
    Since you will have to upgrade Labview to be able to work with that DAQ card of yours, I advise you to upgrade to Labview 6.1, so you can work under XP also.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • Error 10452 at AI Control on HP Ze4210 Notebook

    I just tried a working DAQCard-6024E in an HP Pavilion Ze4210 Notebook running WinXP Home (new out of box) and got the error 10452 when running a LabView 6.1 program. It also fails Test Resources in MAX. The Device Manager does not report any interrupt conflicts. The PCMCIA adapter is O2Micro OZ6912 with the Microsoft Driver PCMCIA.SYS ver 5.1.2600.0. The DAQCard worked before and after on an older desktop. The NI-DAQ version is 6.9.3

    I do not have a different type of computer with XP to try the card, but I tried the card in a different HP Ze4210 with the same results. I did try a second card in the second notebook computer with the same results. I tried removing the NIDAQ software and installing version 6.9.2 and still got the same error. I know that we have tried this type of card in other brands of Notebooks running XP in the past without a problem. With the HP Ze4210, XP will not let me change the IRQ from 11 using Device Manager

  • IRQ conflict on Dell Inspiron 5100 with DAQCard 6024E

    Hi,
    I have DELL INSPIRON 5100 and I am trying to make working my DAQCard 6024E , but it gives me following error on MAX Device Test Panel: The Device is not responding to the First Level IRQ. Would you like to continue anyway? Please see attached file for IRQ allocation on my Laptop.
    What kind of drivers you requested from DELL? Can you please share those drivers so I can try out for my laptop.
    Thanks,
    Kishor Senjaliya"
    Attachments:
    IRQ.doc ‏85 KB

    Wow, it looks like you have quite a bit of stuff on IRQ 10. My guess would be that another device is using that IRQ and not letting the 6024E use IRQ 10. Fortunately, it looks like you should have plenty of other resources available, so I would try to configure your card on another IRQ. Hopefully you can go to the properties on that card in the device manager and try to manualy set the IRQ to one that isn't being used. Good luck.
    Steve.

  • DAQCard-6024E returns all zeros

    I am using a DAQCard-6024E on a 120MHz Pentium desktop running Windows 95 and LabVIEW Run-time 6.1. To duplicate the problem, I built an executable for the Acquire N Scans example and entered Channels 3:0, Number of Scans 1000, Scan rate 20000, and clicked Run Continuously. It works fine for an hour or so, (with occasional timeouts), but then the signal changes to identically zero (no noise and no error messages). After this, the only way I have found to get it going again is to power down the computer or hot unplug/plug the DAQCard-6024E. Re-booting without turning off the power does not work. I have been using the same DAQCard-6024E on another (much faster) computer running Windows 98 and never seen this problem.
    What is the cause of
    this problem and what can I do about it?

    See
    http://exchange.ni.com/servlet/Redirect?id=8470237
    Regards
    Filipe A.
    Applications Engineer
    National Instruments

  • Error 10452 When i test an Individual Channel in MAX

    I am Using an AI-16E-4 DAQ Card and When i test an individual channel (nonreferenced single ended) in MAX, i get error 10452 - Error occurred at AI Control. When I try to test the panels, i get a message that says "The Device is Not responding to the first IRQ level," but MAX still displays data acquired by the DAQ Card. I am using the PCMCIA Card on a PCI to PCMCIA Adapter on my desktop - could that have anything to do with the problem?

    Hi,
    This knowledgebase may be able to help with this issue:
    http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/14dfb1a1788d1f3286256e4d007ca783?OpenDocument
    I hope this helps,
    Andrew A
    Applications Engineer
    National Instruments

  • Where can I find a document listing the instructions one can give the DAQCard-6024E card via the drivers?

    Hi
    We have bought the DAQcard-6024E card with it's drivers. (for PCMCIA)
    I need a list of the instructions for setting up and reading the card using C++.
    Where can I find such a list or document?
    Thanks!

    Hi eben,
    I would recommend taking a look at the DAQ Getting Started Guide. This should have all the information you need. The location of the examples are listed on page 11.
    Regards,
    Kent
    Digital Multimeter Home

  • Pin assignment for DAQCard-6024E

    Card is installed and functioning with 3rd party software. I want to build a simple interface to measure input analogue signals. We bought a bread board from NI (CB-68LPR it says) with a cable to connect to PCMCIA DAQCard 6024E. Now I have access to all 56 pins. But the card came from my 3rd party person and I don't have any manuals and cannot find any infomation about the pin assignments. I found reference to the "DAQ Assistant", but this has not been installed on my system (Measurement and Automation Explorer is there and I can run the Test Panel). Ultimately I will use a program called WINview to monitor my input signals. This seems pretty basic.
    David

    Hello David,
    I think all you are looking for are the pin assignments for the DAQCard-6024E device. This information can be found on page 4-2 of the 6024E User Manual.
    Post back if this was not the only information you were looking for.
    Best Regards,
    Jared A

  • Two edge separator with a NI DAQCard-6024E for PCMCIA

    Hi,
    I have two different TTL-level signals available, and I want to measure the duration of time starting when one signal goes high and stoping when the next signal goes high.
    How can I do this using LabVIEW 5.1 and a NI DAQCard-6024E (PCMCIA)?
    Thankful for every answer.
    Regards,
    Henrik

    Probably the best way to do this is to set up counter 0 to do triggered pulse generation and then do buffered period measurement on counter 1, with the second signal being the gate signal. In other words, the first TTL signal starts the first counter producing a pulse train and the second counter measures this pulse train until the second signal causes it to latch. Look at some of the examples for triggered pulse generation and buffered period measurement and this will probably help you get started.

  • DAQCard-6024E pin connections

    I have a customer who is currently using a DAQCard-700. I have the pin outs for this but he wants to replace this with the DAQCard-6024E. I can't find the pin outs for this, does any one know what they are or where I can get them?
    Thanks
    Kevin

    Hi Kevin,
    It's Peter H from National Instruments technical support department here. The pin-out diagram for all the 16-channel E-series cards except the 6025E, is the second diagram from the left on page 213 of the 2004 National Instruments catalog.
    Hope this helps,
    Best regards,
    Peter H
    Applications Engineer
    National Instruments

  • DaqCard 6024E intermittant with Windows XP

    I am still having trouble running the PCMCIA DaqCard 6024E reliability
    on a Winbook running home version XP. I could get by, but my customers
    can't.
    I ordered two cards, one to upgrade a Winbook laptop running Windows Me
    (from a DaqCard 500) (a little over a year old) and the other for a new
    Winbook which came with XP installed. I also have a new Winbook running
    XP (also home version) and working fine with a DaqPad 6020E from the USB
    port. I am using the latest version of NIDaq, 6.9.2. Once MAX sees the
    card, LabVIEW has no problems.
    Both of the DaqCards cards run fine in the old Winbook running Me.
    Neither of the PCMCIA 6024E cards will run reliably with the XP system.
    >From a cold boot, I have to restart several times (usually between 5 and
    10 times) before the card is recognized (little icon in task bar). Or
    if I boot once and then just unplug and replug the card - hot - it also
    requires about 5 to 10 of these cycles. Once its recognized, if I
    unplug and replug the card it will not fail to recognize the card until
    between 15 and 20 tries.
    Just to verify that the laptop is ok, I bought a PCMCIA ethernet card.
    The box for the ethernet card (Netgear FA411) indicated that it would
    run with Windows 95/98/Me and a sticker on the cellophane wrapper said
    "Works with Windows XP". The sticker (afterthought) suggested to me
    that if it would work with Windows 95/98/Me it would also work with XP.
    I rebooted 25 times and the computer recognized it every time. I also
    unplugged and plugged the either net card - hot - 25 times and the
    computer recognized it every time.
    Winbook will not guarantee survival if I try to load 98 or Me in the new
    computer. I think these systems are assembled and loaded in China and
    they don't have the drivers in Ohio. By the way, this is my fifth
    Winbook, and this is my first problem. Otherwise XP seems to run better
    than Me. My new Winbook with XP and the DaqPad has never failed. I
    have been using it nearly every day since February. I developed both of
    the DacCard systems with it.
    I think the Winbooks, about $1000, and the DaqCards are perfect for my
    customers. I hope we can fix this problem.
    For the present, my clients are using the computers in the lab and are
    able to leave them on continuously 24X7. But soon they will get
    approvals and will have to go to the clinic for their study. They have
    to move a cart into a room, plug in the equipment and can't be messing
    with the cards when the room is $700 per hour and the Doctors are upset
    (that's a mild term). If we loose a study, we have lost a consenting
    patient, (they are not easy to come by these days). I suppose, if I
    have to, we could use DaqPAds, but I don't want to do that, nor do I
    want the lose the restocking fee. In addition, I am currently putting
    another system together, which I will deliver at the end of July. Not
    sure what to buy, DaqCard or DaqPad (prefer DaqCard).
    Thank, Harry
    Harry L. Valenta, Jr., Ph.D.
    Biomedical Research Associates, LLC
    19042 E. Oxford Drive
    Aurora, CO 80013-3812
    phone and fax, 303 690 9688
    [email protected]
    [email protected]
    www.bra-llc.com

    Harry;
    We don't have anything reported yet about Winbooks and Windows XP.
    One thing you can try out though, is to see if the Socket drivers in use by the Winbook are the Native ones provided by Microsoft.
    If they aren't uninstall those and install the NAtive ones from the Windows installation CD. If that is the case, it's probably the cause of the problem.
    Hope this helps.
    Filipe

  • Error while using P2V in Oracle VM 2.2 version

    Error while using P2V in Oracle VM 2.2 version
    I tried using this option by using the steps given on one link but it didnt worked...
    Error:
    code 404, message No permission to list directory.
    I ve tried giving full permissions on for /OVS on Server but invain.
    Can U pls help me...
    Thanks in advance.
    Edited by: user10310678 on Sep 16, 2009 3:32 AM

    user10310678 wrote:
    I am using beta version. Oracle VM Manager 2.2.0If you have a beta version of 2.2, then you should be an Oracle employee. Please ask this question on an internal mailing list. If you are not an Oracle employee, please ask the employee that gave you this beta. As this is a beta, some functionality may not be operational yet, so I can't answer why this particular feature seems not to work.

Maybe you are looking for

  • How to open a jpg file in camera raw in Photoshop CC (2014)?

    I know i can do it via bridge but do i also have some option than using bridge?

  • Process route for case management.

    How to configure the process route in case management. I want to determine the person a case should go to when the status is changed. The person who changes the status should be able to select or determine who the case goes to. when i try to do this

  • Filter on Leave Type based on ESG

    Hi All, I have one PSG and within that I have 2 ESG. One Type of leave is applicable to only 1st ESG. So for other ESG, that leave type should not come at all. How can we achieve this since leave type can only be mapped to PSG. I have seen many threa

  • Tutorial to Move from one iPhone to Another

    Would anyone happen to know of a good source to give a step-by-step tutorial of how to move from one iphone to another?  (move from iphone 4 to iphone 5).  Would like to get myself familiar with this process before I have to do it on Friday, Sept 21s

  • Can't start wl 12.1.1

    After installed weblogic 12.1.1 at a first time that I start server I see this error: <May 12, 2012 4:15:06 PM BRT> <Error> <Security> <BEA-090870> <The realm "myrealm" failed to be loaded: weblogic.security.service.SecurityServiceException: com.bea.