Error 1074396024 occur at imaq usb snap.vi

hallo, ich habe labview 8.0 mit dem vision development modul und
benutze eine logitech webcam zur bilderfassung. ich habe ein vi
erstellt das im zeitraum von 1s ständig neue bilder macht und diese mit
einem referenzbild vergleicht. mein problem ist das so bei ungefähr
1000 vergleichen eines neuen bildes mit dem referenzbild der fehler
1074396024 occur at imaq usb snap.vi auftritt und ich aber nicht weiß
warum.  würde mich freuen wenn mir jemand helfen kann

Please have a look at this thread which discusses similar issues in detail.
Best regards,
Jochen Klier
National Instruments Germany

Similar Messages

  • Error 0xBFF60492 on IMAQ USB snap.vi RT Video not support displaying selected color depth

    Attempting to snap a picture with NI-IMAQ for USB in LabVIEW 8.0  using the following procedure.
    1)I get the first enumerated camera, 2) open a session, with returned
    string [0], 3) start a session, 4) snap a picture and 5) close
    vi.  My problem is that in step 4 with the IMAQ USB Snap.vi, I get
    the following error.
    Error -1074396014 occurred at IMAQ USB snap.vi
    The image passed is not valid.
    Possible Reasons(s):
    IMAQ Vision: (Hex 0xBFF60492) RT Video Out does not support displaying the supplied image type at the selected color depth.
    I give the snap.vi an Image in from rightclick->Create->Control
    or rightclick->Create->Constant.  The output image (on the
    Front Panel) created by rightclick->Create->Indicator.
    LabVIEW should insert the correct data structure to match the expected
    input/output, and there is nothing I can that changes he color
    depth.  The GetImageInfo.vi reports that the camera is set up for
    4 Bytes Per Pixel, with the rectangle 352x288.
    Also the error message refers to RT Video Out, but I am using USB.  This distinction is significant in NI Vision Assistant.

    Hello together,
    I wanted to use a Sanyo Xacti CG 10 video camara in LabView.
    By using the NI-IMAQ for USB Snap I get the following error: IMAQ Vision: (Hex 0xBFF60492) Ungültige Blit-Funktion des Videoausgangs.
    Is it possible, that I can not use this camera in LabView?
    Thanks a lot for your reply

  • IMAQ USB Snap.vi time out

    I'm trying to capture an image in LabView using a veo stingray webcam.
    I'm using LabView 7.1 with Vission Assistant 7.1. I've attached my
    block diagram. When I press run LabView recognizes my camera, but I
    always get the following error.
    Error -1074396030 occured at IMAQ USB Snap.vi Time Out.
    Any suggestions would be appreciated.
    Attachments:
    labview.JPG ‏30 KB

    The QuickCam is indeed USB. The error appears when the vi is closed without using the IMAQ USB Close.vi (for instance when aborting the execution using the toolbar stop button). So, problem solved. Unfortunatelly this was not the only issue : Now my vi does not crash LV... but returns only a black image...
    For professionnal use, I have several NI frame grabbers. For teaching, I don't have a budget for 16 firewire adaptators and cameras . I'll try re-installing the software one more time.
    This is not a big problem because as I said before, the grab function is working. However, I don't like giving my students the idea that sometimes only 50 % of LabVIEW functions are working properly.
    Chilly Charly    (aka CC)
             E-List Master - Kudos glutton - Press the yellow button on the left...        

  • Error -1074397150 occurred at IMAQ Snap.vi

    Hi.
    (Sorry if my English is wrong )
    I want to snap a picture - from a camera that was designed in my lab - and save it in a BMP file.
    I use the "IMAQ PCI-1428" to accomplish this task and the "HL snap&save to BMP.vi".
    But, as I try to run the VI I'm getting this error - "Error -1074397150 occurred at IMAQ Snap.vi", afterward I'm getting
    another massage - "ERROR(DMA Timeout): The system is unable to capture all of the incoming video data....".
    What should I do, to resolve this problem?
    ThanX.

    Hi elbit,
    Here is a link to Error
    Codes with NI-IMAQ.  You error is
    addressed there and that information may be helpful to you.
    I noticed you were using the PCI-1428 framegrabber card.  This card supports Camera Link cameras.  In order to tell the PCI-1428 how to
    communicate with the camera, the NI-IMAQ driver uses a camera file that
    contains camera specific information for configuration.  You will need to have a properly configured
    camera file for you camera that you have created.
    NI has a large number of camera files that are created and
    certified to support popular industrial grade cameras.  In cases where a custom camera file is needed,
    NI provides the NI-Camera
    File Generator as a utility for camera file creation.  Keep in mind that custom camera files are not
    supported by National Instruments Applications Engineers.
    Good luck with your camera design.  Please let us know if you have any further
    questions or concerns.
    Regards,
    Luke H

  • Error - 1074397153 occurred at IMAQ Grab Setup.vi

    The sensor we are using is Goodrich SU640KTSX. I can run SUI image Analysis 3.1 software, Measurement & Automation software, and MATLAB code on an XP machine with no errors when grabbing images. We are tying to build a newer PC;
    Dell T7500 with Intel xeon CPU x5650 @ 2.67GHz 
    Memory; 12GB
    OS Win7  64-bit
    Camlink card is NI PCIe-1430
    Nvidia QUADRO 4000
    The error we get is "Error -1074397153 occurred at IMAQ Grab Setup.vi / Cannot detect recognizable video source" when using the SUI image Analysis 3.1 software or MATLAB code. When we use the NI-IMAQ i/o 2.3.1- Measurement & Automation  I can snap, grab and record without any error. 
    Any help on this would be great
    Thanks

    Hi,
    Let us know which standard your camera is following (whether it is cameralink or ethernet).
    Check this link for error info: http://digital.ni.com/public.nsf/allkb/3434173630CBC97686256F8000536593.
    If at all it is cameralink camera make sure that you are following proper trigger sequence for your camera. As u are grabbing frames in MAX and not in other acquisition softwares it might be triggering issue or cables problem.

  • Error -1074397038 occurred at IMAQ Start.vi for 64bit Labview 2011 SP1, Win7

    Hello,
    I am using a MC1362 camera from Mikrotron with a PCIe1433 framegrabber. I was using it with windows XP, 32 bit, labview 2010 SP1 32 bit, it was working perfectly fine. I just switch to windows 7 with labview 2011 SP1 64bit, and it is not working anymore with my custom routine in labview, though it works with MAX and camera file generator and I use the same camera file.
    When I run my routine, I have this error message:
    Error -1074397038 occurred at IMAQ Start.vi
    Possible reason(s):
    NI-IMAQ:  The requested serial termination string was not found in the returned buffer.
    Then, If I try to run the camera with MAX, it doesn't work anymore, I have to reboot the camera, and put it in the right mode with the Mikrotron control tool to obtain an image.
    I have seen similar issue on a Basler camera on the forum, and it has been solved by using a camera file to set the different parameters. There is no camera file complete to set all the parameters of the camera, so I had to program them in serial to drive the camera with my Labview routine.
    Could you help me to solve this issue please?
    Thanks
    Bests
    David Dulin

    This forum post is already handled --> SR 1154262.
    Kind regards,
    Corné Westeneng
    Applications Engineer
    NI-Netherlands

  • Error -1074395975 occurred at IMAQ AVI Read Frame DirectX has timed out readin

    When i run the "Read AVI Example" on every kind of AVI file, I get the error:
    Error -1074395975 occurred at IMAQ AVI Read Frame DirectX has timed out reading or writing the AVI file. When closing an AVI file, try adding an additional delay. When reading an AVI file, try reducing CPU and disk load.

    The forums search gives two threads talking about this error:
    http://forums.ni.com/ni/board/message?board.id=170&message.id=392042&requireLogin=False
    http://forums.ni.com/ni/board/message?board.id=170&requireLogin=False&thread.id=195832
    Did you allready had a look at them?

  • Error -1074395395 occurred at IMAQ Match Color Pattern after merge programs

    Dear all
    I  have 2 separate programs that use same source image (red01a1.jpg). The first find location of color particles (color location 01.vi) and second find location of particles after threshold  color image (particle location 01.vi).  Both of them run good.  
    But when  2 programs were merged  into one program (color sorter 01i.vi), that happened error . The error message is “Error -1074395395 occurred at IMAQ Match Color Pattern”. How can I fix it ?
    Thanks  
    Solved!
    Go to Solution.
    Attachments:
    color sorter 01i.vi ‏126 KB
    Color -particle location.zip ‏86 KB
    red01a1.zip ‏86 KB

    Hi Xuan
    Check it out the attached vi
    Sasi.
    Certified LabVIEW Associate Developer
    If you can DREAM it, You can DO it - Walt Disney
    Attachments:
    color sorter 01i.vi ‏120 KB

  • Why is IMAQ USB Snap.vi constantly giving out a 32-bit image?

    Hi.
    I'm using some USB cameras (uEye) with Direct Show. I use the IMAQ USB camera tools (with Labview 7.1, Vision 7.1.1) as in the examples. In particular I'm working in the snap mode.
    I create an U8 image (IMAQ Create) which I use as input to IMAQ USB Snap.vi and I set the camera's video mode to grayscale (Y8) using IMAQ USB PropertyPage.vi
    But, I don't get an 8-bit image out of IMAQ USB Snap.vi. The image is always converted to 32-bit RGB. In principal It works like this, but it costs me valuable time to convert the image to 8-bit at some points of the program where I need the image grayscale array.
    Cheers,
    mirola 
    Labview 5.1 - 2011

    Hi Elmar,
    Thanks for answering.
    Of course, the "not officially supported" thing is a killer argument. But the device shall work with a laptop and, as I know, the firewire cameras need an additional power supply when connected to a laptop 1394.
    The camera I use is grayscale and only works properly when I write 8-bit grayscale in its settings (e.g. using IMAQ USB PropertyPage.vi).
    As I said, everything I can set is set to 8-bit. The Snap.vi converts the input IMAQ image to 32-bit.
    But maybe you are right and it's just that NI's USB Direct Show dll is not treated with high priority (note: I use the most recent one, although I combine it with older LV and Vision versions.) Otherwise I guess I would get more answers here.
    On the other hand, if I ask the manufacturer he will probably say I should use his SDK which I don't want at this point.
    Best regards,
    mirola 
    Labview 5.1 - 2011

  • Error -1074396116 occurred at IMAQ CalibrationTargetToPoints

    Error -1074396116 occurred at IMAQ CalibrationTargetToPoints, So there any one to solve this problem and thank you.

    there is the VI and the picture of device. SO i need to calculate the dimension and thank you
    Attachments:
    Calibration.vi ‏77 KB
    Capture.PNG ‏27 KB

  • IMAQ USB Snap hangs all of LabVIEW?!?

    I am having trouble with my USB cameras hanging a production machine. We are using 4 usb cameras from uEye for inspection and vision correction on a pick and place robot. The application is multithreaded, yet when the SNAP VI hangs, all threads in the application hang.
    I can repeat this problem by disconnecting the USB cable to a camera. The system does not recover even after the USB is reconnected.
    I have found in the past the Microsofts USB driver power managment seems to have an effect on the reliability of the USB system. The machine is also exposed to vibration which could cause intermittent connections.
    While we are trying to solve all of these issues, I seem to have no way to detect if the camera is present before snapping the image. I cannot seem to prevent the system from snapping while the USB is disconnected.
    Is there anything than can be done in order to have the SNAP vi return an error rather than hanging, or to tell the status of the device before snapping?
    I have attached two example VI's which both repeatably cause the freeze. Just run the sample, plug in the usb camera, then disconnect it.
    Im not sure if this is a LVDirectShow level issue, a DirectShow level issue, or a Camera Manufacturer(driver) issue (uEye).
    If anyone has another brand of usb camera and can give my tests a quick run I would appreciate the feedback.
    Thanks,
    -Tim
    Certified LabVIEW Developer
    Attachments:
    ConnectJustInTime.vi ‏55 KB
    ConnectJustInTime1.vi ‏55 KB

    Oops, I posted the same sample twice. heres the other one.
    Attachments:
    ConnectSnapDisconnect.vi ‏56 KB

  • How to solve Error -1074396080 occurred at IMAQ array to color Image

    Hello,
    I am getting above mentioned error.
    Here I have attached my screen shot of the error.
    Could any one Please guide me how to solve this error.
    I am using Kinesthesia kinect driver which generate U24 Bit RGB Image and I want to convert it in IMAQ Image type, But I am getting mentioned error.
    But when I am not using the vision acquisition and vision assistant then every thing is fine means there is no any error which I have attached in attachment 2.
    Please guide me how to solve this problem.
    Thank you very much.
    Solved!
    Go to Solution.
    Attachments:
    invalid image type.png ‏251 KB
    imaq2.png ‏56 KB

    Thank you very much for quick reply.
    I follow your instruction but it give me still same error.
    here in attachment I have attache screen shot as well Vi so you have a look.
    thank you very much once again for help and time.
    Attachments:
    Unbenannt.png ‏174 KB
    kinect templet.vi ‏137 KB

  • Error from IMAQ USB Grab Setup in executable

    I created an executable that returns
    Error 1074396024 occured at IMAQ USB Grab Setup.vi
    IMAQ Vision: Minimum coverage value should be greater than zero.
    I developed the executable on a 32 bit machine with LabVIEW 2009 and the Vision Development Module 2012 SP1. The target computer has LabVIEW Vision Development Module 2012 and LabVIEW Run-Time Engine 2009 SP1 (32-bit Standard).
    Other people on the forum have had this error, and I tried everything they suggested. I continue to get the error. I have also tried downloading IMAQ and Vision Aquisition Software, but I get the same message. Some people have had problems with versions of LabVIEW in different languages, but I am only using english. Is this problem caused by not having the correct run-time engines?
    Any help would be greatly appreciated.
    Thanks!
    Solved!
    Go to Solution.

    Hello Eckman,
    Do you have the Vision Development Module Run-Time Engine (VDM RTE) installed on your target machine? You will need the RTE to run vision applications as a deployed executable. 
    Vision Development Module Run-Time Engine 2012 SP1
    Please let me know if you install the run-time engine (or already have) an still receive the same error message.
    Regards,
    Ian K.
    Applications Engineer
    National Instruments

  • IError -1074395992 occurred at IMAQ ReadFile when processing batch via a vi

    I have built a vi from a visoin assitant file via the automated vi creation under tools in vision assitant. The vi works fine on a single file but then the input control is changed to select an entire directory it crashed with
    Error -1074395992 occurred at IMAQ ReadFile File access denied.
    It reads all the files individually but won't run in the batch mode.
    Attachments:
    vitest.vi ‏164 KB

    Hi Patrick,
    Sorry it's taken so long to get back to you.  The function you are trying to use doesn't actually support reading of many files at a time (batch processing), what you will have to do is extract all of the path names individually and then complete paralel processing on all of the images.  (The image constant that is passed to each of the functions can only store one image at a time)
    I have taken your vi and changed it slightly to allow for this functionality.
    I hope this helps
    AdamB
    Applications Engineering Team Leader | National Instruments | UK & Ireland
    Attachments:
    vitest[1].vi ‏80 KB

  • NI 845x USB: Error -301713 occurred at Property Node (arg 2) in General I2C Read.vi

    Hello,
    I am currently working  with digital accelerometer LIS35DE from ST Microelectronics. I want to start with tests of this device. For that purpose I used NI 845x USB to connect with accelerometer via I2C. Unfortunately, when I made electrical connections and set up parameters of communication and run the program (I found it in examples) the following error occured:
    Error -301713 occurred at Property Node (arg 2) in General I2C Read.vi
    Possible reason(s):
    NI-845x:  An input parameter, or combination of parameters, is invalid. An example of this error may be setting an invalid baud rate or enabling I2C ACK polling while using 10-bit addressing.
    The code can be found in attachements. I couldn't find any extended description of this problem. What could be a problem: incorrect device address, register address, configuration parameters?
    Any help is appreciated!
    Best regards,
    Michael
    Attachments:
    General I2C Read.vi ‏24 KB

    Hi MicMac89!
    First of all could you please post which version of LabView are you using?
    Could you please tell me which version of 845X hw are you using? (8451 or 8452)
    I opened the example you attached. As you wrote the error occurs at the second argument of the property node. (I guess this is the first property node where the error occurs.)
    This argument of the property node enables the onboard pull-up resistors. But not all NI-845x hardware support pull-up resistors. (Because of this is important to know which hw version are you using.)
    Did you try the example with disabling the pull-up resistors?
    I suggest you to go through the Manual of this product, (if you did this not yet) This could make it clear where and when to use what kind of pull-up resistors.
    For example: If you are using 8452, you must enable pull-up resistors, for Vref ≤ 1.8 V for the FPGA to properly detect a low-to-high transition
    Manual: http://www.ni.com/pdf/manuals/371746d.pdf
    HW specification: http://www.ni.com/pdf/manuals/290598a.pdf
    Please post if my suggestions helped. Of course if you have any questions, don't hesitate to post them.
    Best regards, 
    Balazs Nagy

Maybe you are looking for

  • ErrorERR-7621 while login to application

    HI, all I encountered below error when I try to login to one of our Apex application *"Error     ERR-7621 Could not determine workspace for application (:) on application accept.* *Expecting p_company or wwv_flow_company cookie to contain security gr

  • Adobe Media Encoder CS 6 works for one user login - not the other

    Slightly odd... but Adobe Media Encoder CS 6 will open fine in my basic test user account but not my main user account (or guest account).  In my main account in will crash just before it starts to load up all the bits 'n' pieces but loads up perfect

  • Down payment request without PO possible?

    Hello, Is it possible to create a down payment request without having to use a PO. This concerns financial postings for services. Thank you for sharing your experience. Kind regards, Linda

  • Integration (IKM) does not appear in Interface

    Hi All, I'm using ODI 10.1.3.5 and trying to load data from sql to essbase. Then my problem is.. when I want to choose the IKM in my interface, the IKM SQL to Hyperion (Data) and the IKM SQL to Hyperion (Metadata) aren't appear. Whereas I've import t

  • CS4 Dreamweaver Question: "Find all" has stopped working.

    Dreamweaver will no longer perform a search using the "Find All" option. Nor will it place results in the Search panel. Can you help in answering the question of how to make it work again? Dreamweaver will . . . Find Next within the current document.