Error -1074396116 occurred at IMAQ CalibrationTargetToPoints
Error -1074396116 occurred at IMAQ CalibrationTargetToPoints, So there any one to solve this problem and thank you.
there is the VI and the picture of device. SO i need to calculate the dimension and thank you
Attachments:
Calibration.vi 77 KB
Capture.PNG 27 KB
Similar Messages
-
Error -1074397038 occurred at IMAQ Start.vi for 64bit Labview 2011 SP1, Win7
Hello,
I am using a MC1362 camera from Mikrotron with a PCIe1433 framegrabber. I was using it with windows XP, 32 bit, labview 2010 SP1 32 bit, it was working perfectly fine. I just switch to windows 7 with labview 2011 SP1 64bit, and it is not working anymore with my custom routine in labview, though it works with MAX and camera file generator and I use the same camera file.
When I run my routine, I have this error message:
Error -1074397038 occurred at IMAQ Start.vi
Possible reason(s):
NI-IMAQ: The requested serial termination string was not found in the returned buffer.
Then, If I try to run the camera with MAX, it doesn't work anymore, I have to reboot the camera, and put it in the right mode with the Mikrotron control tool to obtain an image.
I have seen similar issue on a Basler camera on the forum, and it has been solved by using a camera file to set the different parameters. There is no camera file complete to set all the parameters of the camera, so I had to program them in serial to drive the camera with my Labview routine.
Could you help me to solve this issue please?
Thanks
Bests
David DulinThis forum post is already handled --> SR 1154262.
Kind regards,
Corné Westeneng
Applications Engineer
NI-Netherlands -
Error -1074395975 occurred at IMAQ AVI Read Frame DirectX has timed out readin
When i run the "Read AVI Example" on every kind of AVI file, I get the error:
Error -1074395975 occurred at IMAQ AVI Read Frame DirectX has timed out reading or writing the AVI file. When closing an AVI file, try adding an additional delay. When reading an AVI file, try reducing CPU and disk load.The forums search gives two threads talking about this error:
http://forums.ni.com/ni/board/message?board.id=170&message.id=392042&requireLogin=False
http://forums.ni.com/ni/board/message?board.id=170&requireLogin=False&thread.id=195832
Did you allready had a look at them? -
Error -1074395395 occurred at IMAQ Match Color Pattern after merge programs
Dear all
I have 2 separate programs that use same source image (red01a1.jpg). The first find location of color particles (color location 01.vi) and second find location of particles after threshold color image (particle location 01.vi). Both of them run good.
But when 2 programs were merged into one program (color sorter 01i.vi), that happened error . The error message is “Error -1074395395 occurred at IMAQ Match Color Pattern”. How can I fix it ?
Thanks
Solved!
Go to Solution.
Attachments:
color sorter 01i.vi 126 KB
Color -particle location.zip 86 KB
red01a1.zip 86 KBHi Xuan
Check it out the attached vi
Sasi.
Certified LabVIEW Associate Developer
If you can DREAM it, You can DO it - Walt Disney
Attachments:
color sorter 01i.vi 120 KB -
Error -1074397150 occurred at IMAQ Snap.vi
Hi.
(Sorry if my English is wrong )
I want to snap a picture - from a camera that was designed in my lab - and save it in a BMP file.
I use the "IMAQ PCI-1428" to accomplish this task and the "HL snap&save to BMP.vi".
But, as I try to run the VI I'm getting this error - "Error -1074397150 occurred at IMAQ Snap.vi", afterward I'm getting
another massage - "ERROR(DMA Timeout): The system is unable to capture all of the incoming video data....".
What should I do, to resolve this problem?
ThanX.Hi elbit,
Here is a link to Error
Codes with NI-IMAQ. You error is
addressed there and that information may be helpful to you.
I noticed you were using the PCI-1428 framegrabber card. This card supports Camera Link cameras. In order to tell the PCI-1428 how to
communicate with the camera, the NI-IMAQ driver uses a camera file that
contains camera specific information for configuration. You will need to have a properly configured
camera file for you camera that you have created.
NI has a large number of camera files that are created and
certified to support popular industrial grade cameras. In cases where a custom camera file is needed,
NI provides the NI-Camera
File Generator as a utility for camera file creation. Keep in mind that custom camera files are not
supported by National Instruments Applications Engineers.
Good luck with your camera design. Please let us know if you have any further
questions or concerns.
Regards,
Luke H -
Error - 1074397153 occurred at IMAQ Grab Setup.vi
The sensor we are using is Goodrich SU640KTSX. I can run SUI image Analysis 3.1 software, Measurement & Automation software, and MATLAB code on an XP machine with no errors when grabbing images. We are tying to build a newer PC;
Dell T7500 with Intel xeon CPU x5650 @ 2.67GHz
Memory; 12GB
OS Win7 64-bit
Camlink card is NI PCIe-1430
Nvidia QUADRO 4000
The error we get is "Error -1074397153 occurred at IMAQ Grab Setup.vi / Cannot detect recognizable video source" when using the SUI image Analysis 3.1 software or MATLAB code. When we use the NI-IMAQ i/o 2.3.1- Measurement & Automation I can snap, grab and record without any error.
Any help on this would be great
ThanksHi,
Let us know which standard your camera is following (whether it is cameralink or ethernet).
Check this link for error info: http://digital.ni.com/public.nsf/allkb/3434173630CBC97686256F8000536593.
If at all it is cameralink camera make sure that you are following proper trigger sequence for your camera. As u are grabbing frames in MAX and not in other acquisition softwares it might be triggering issue or cables problem. -
Error 1074396024 occur at imaq usb snap.vi
hallo, ich habe labview 8.0 mit dem vision development modul und
benutze eine logitech webcam zur bilderfassung. ich habe ein vi
erstellt das im zeitraum von 1s ständig neue bilder macht und diese mit
einem referenzbild vergleicht. mein problem ist das so bei ungefähr
1000 vergleichen eines neuen bildes mit dem referenzbild der fehler
1074396024 occur at imaq usb snap.vi auftritt und ich aber nicht weiß
warum. würde mich freuen wenn mir jemand helfen kannPlease have a look at this thread which discusses similar issues in detail.
Best regards,
Jochen Klier
National Instruments Germany -
How to solve Error -1074396080 occurred at IMAQ array to color Image
Hello,
I am getting above mentioned error.
Here I have attached my screen shot of the error.
Could any one Please guide me how to solve this error.
I am using Kinesthesia kinect driver which generate U24 Bit RGB Image and I want to convert it in IMAQ Image type, But I am getting mentioned error.
But when I am not using the vision acquisition and vision assistant then every thing is fine means there is no any error which I have attached in attachment 2.
Please guide me how to solve this problem.
Thank you very much.
Solved!
Go to Solution.
Attachments:
invalid image type.png 251 KB
imaq2.png 56 KBThank you very much for quick reply.
I follow your instruction but it give me still same error.
here in attachment I have attache screen shot as well Vi so you have a look.
thank you very much once again for help and time.
Attachments:
Unbenannt.png 174 KB
kinect templet.vi 137 KB -
IError -1074395992 occurred at IMAQ ReadFile when processing batch via a vi
I have built a vi from a visoin assitant file via the automated vi creation under tools in vision assitant. The vi works fine on a single file but then the input control is changed to select an entire directory it crashed with
Error -1074395992 occurred at IMAQ ReadFile File access denied.
It reads all the files individually but won't run in the batch mode.
Attachments:
vitest.vi 164 KBHi Patrick,
Sorry it's taken so long to get back to you. The function you are trying to use doesn't actually support reading of many files at a time (batch processing), what you will have to do is extract all of the path names individually and then complete paralel processing on all of the images. (The image constant that is passed to each of the functions can only store one image at a time)
I have taken your vi and changed it slightly to allow for this functionality.
I hope this helps
AdamB
Applications Engineering Team Leader | National Instruments | UK & Ireland
Attachments:
vitest[1].vi 80 KB -
Error -1074396199 occurred at Invalid Coordinate System error is coming when i try to run the VI. i had used simple 3 things first is Orignal image than colour extract then pattren maching then coordinate system.
But it gives error during run time.
PLease solve...
Gagandeep sharmaThis could have any number of causes. Maybe the image size was changed, or the coordinate system did not carry over after an Image Copy, or Image save. More datails would be helpful to make a better determination.
Machine Vision, Robotics, Embedded Systems, Surveillance
www.movimed.com - Custom Imaging Solutions -
Error 42 occurred at ni_tagger_​lv_Write
I am trying to output an IMAQ Image to a network variable. However, when I run the VI I receive the error message "Error 42 occurred at ni_tagger_lv_Write", "Possible reason(s): LabVIEW: Generic error."
Is there some kind of setup I need to perform to get network variables working? All I did was add one to the project and configure it as a variant. As a side note, the program works fine using "single-process" variables as opposed to "network-published" variables.
edit: I am using LabVIEW 8.2.1
Message Edited by thorholiday on 06-25-2007 12:09 PMThere is a problem sending certain datatypes to network published Variant Shared Variables. This problem (Error 42) still exists as of LV 8.6.1. See my post here:
http://forums.ni.com/ni/board/message?board.id=170&thread.id=342875
-Jason
Certified LabVIEW Architect
Wait for Flag / Set Flag
Separate Views from Implementation for Strict Type Defs -
Error-1074360293 occured at IMAQdz GetImage.vi
At first, my Labview program acquired 1-5 images and then this error message would pop:
Error-1074360293 occured at IMAQdz GetImage.vi
Possible reasons(s):
NI-IMAQ-dx: (Hex 0xBFF6901B) Time Out
After reading a bit about that error on the forum, I turned down my firewall. Now it goes much better, but the error message still appears from time to time (every 10-200 images depending of the time).
Would someone have an idea to help?
Thank you!Since you mention the firewall, I am going to assume that you are using a GigE camera.
1. If you are using a network adapter that supports Jumbo Packets, you will need to access the advanced properties tab of the adapter, and turn on Jumbo Packet support.
2. If you do not have a network adapter that supports Jumbo Packets, you will need to configure the camera in MAX to use a packet size <= 1024. 8000 is the default.
3. If you want to not turn off your firewall, and if the camera suports it, you can enable Firewall Traversal. You will need to click on "SHOW ALL ATTRIBUTES" in the Attributes tab, and look under the GeniCAM section.
4. Make sure that any devices between your PC and your camera support jumbo packets as well (routers, switches, etc.)
5. It would be best to use a CAT6 cable directly between the PC and the camera.
Machine Vision, Robotics, Embedded Systems, Surveillance
www.movimed.com - Custom Imaging Solutions -
I am attempting to open a vi for editing, and instead the vi is attempting to execute. I get the error:
"Error 7 occurred at Invoke Node in BuildTargetBuildSpecification.vi->BuildXFS.vi"
Possible reason(s): LabVIEW: File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on Linux. Verify that the path is correct using the command prompt or file explorer.
Method Name: Project: Open
When I close the Error Message dialog, Labview terminates.Hi R.Jay,
Error 7 generally occurs when trying to create an executable when there is an extra instance of a top-level vi. You may need to remove the file as a support file (but leave it as the top level vi).
Are you trying to run an executable that has already been created? Unless you have already built an executable, it should not automatically run when opened. Also, was it built in a previous version of LabVIEW? Sometimes this error can be seen when you upgrade to a newer version without compiling.
Regards,
Lauren
Applications Engineering
National Instruments -
Error 7 occurred at open vi reference in New Report.VI
Hello!
I use the report generation toolkit on LabView 7.0 to create a report in Excel. The program works fine until I make an executable version. I the get the error:
Error 7 occurred at open vi reference in New Report.VI
I use the New Report.VI, Bring Excel to front.VI and Save Report To File.vi
Can you pleace help me!!!Most likely, you did not include the required libraries in your build script. When building an executable in which you use the Report Generation Toolkit, you must include the _Word Dynamic VIs.vi from _wordsub.llb and _Excel Dynamic VIs.vi from _exclsub.llb as dynamic VIs on the Source Files tab.
Check this article for more info.
http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/86256a47004e16d186256a84004cb883?OpenDocument
Daniel L. Press
PrimeTest Corp.
www.primetest.com -
I'm using share point 2007 under windows server 2008 R2(one web server, another db server).When I publish a excel(*.xlsx) to report library or view it in web browser with the same error as bellows:
Excel Web Access
An error has occurred.
Please contact your system administrator if this problem persists.
Please kindly support to guide how to fix it with bellow information in details such as log.Many thanks!
1. The 12/logs file is as bellows:
10/10/2014 09:53:55.18 w3wp.exe (0x6528) 0x5C08 Excel Services
Excel Calculation Services 2u7d Medium ExcelServerSharedWebApplication.Local: An exception was thrown by configdb infrastructure: System.InvalidOperationException: ExcelServerSharedWebApplication.Local: Could
not get ServerContext.Current, which indicates that either SharePoint or the SSP infrastructure isn't provisioned correctly or that we're running outside of a web context. at Microsoft.Office.Excel.Server.ExcelServerSharedWebApplication.get_Local().
10/10/2014 09:53:55.18 w3wp.exe (0x6528) 0x5C08 Excel Services
Excel Services Administration 8tqh Critical Excel Services: Unexpected exception while trying to access Shared Services Database;. Error = ExcelServerSharedWebApplication.Local: Could not get ServerContext.Current, which indicates that
either SharePoint or the SSP infrastructure isn't provisioned correctly or that we're running outside of a web context..
10/10/2014 09:53:55.18 w3wp.exe (0x6528) 0x5C08 Excel Services
Excel Web Access 6nfi Unexpected InternalEwr.OpenWorkbook - An unexpected exception in the ECS Proxy occurred. Message: Microsoft.Office.Excel.Server.ExcelServerSettingException:
An error has occurred. ---> System.InvalidOperationException: ExcelServerSharedWebApplication.Local: Could not get ServerContext.Current, which indicates that either SharePoint or the SSP infrastructure isn't provisioned correctly or that we're running
outside of a web context. at Microsoft.Office.Excel.Server.ExcelServerSharedWebApplication.get_Local() --- End of inner exception stack trace --- at Microsoft.Office.Excel.Server.ExcelServerSharedWebApplication.get_Local()
at Microsoft.Office.Excel.Server.ExcelServerSettings.get_Settings() at Microsoft.Office.Excel.Server.ExcelServerSettings.get_EcsList() at Microsoft.Office...
2.the event in event viewer is:
Log Name: Security
Source: Microsoft-Windows-Security-Auditing
Date: 2014/10/10 9:49:43
Event ID: 4625
Task Category: Logon
Level: Information
Keywords: Audit Failure
User: N/A
Computer: ***.net
Description:
An account failed to log on.
Subject:
Security ID: NULL SID
Account Name: -
Account Domain: -
Logon ID: 0x0
Logon Type: 3
Account For Which Logon Failed:
Security ID: NULL SID
Account Name: ***
Account Domain: ***
Failure Information:
Failure Reason: An Error occured during Logon.
Status: 0xc000006d
Sub Status: 0x0
Process Information:
Caller Process ID: 0x0
Caller Process Name: -
Network Information:
Workstation Name: ***
Source Network Address: ***
Source Port: 63664
Detailed Authentication Information:
Logon Process:
Authentication Package: NTLM
Transited Services: -
Package Name (NTLM only): -
Key Length: 0
This event is generated when a logon request fails. It is generated on the computer where access was attempted.
The Subject fields indicate the account on the local system which requested the logon. This is most commonly a service such as the Server service, or a local process such as Winlogon.exe or Services.exe.
The Logon Type field indicates the kind of logon that was requested. The most common types are 2 (interactive) and 3 (network).
The Process Information fields indicate which account and process on the system requested the logon.
The Network Information fields indicate where a remote logon request originated. Workstation name is not always available and may be left blank in some cases.
The authentication information fields provide detailed information about this specific logon request.
- Transited services indicate which intermediate services have participated in this logon request.
- Package name indicates which sub-protocol was used among the NTLM protocols.
- Key length indicates the length of the generated session key. This will be 0 if no session key was requested.
Event Xml:
<Event xmlns="">
<System>
<Provider Name="Microsoft-Windows-Security-Auditing" Guid="{54849625-5478-4994-A5BA-3E3B0328C30D}" />
<EventID>4625</EventID>
<Version>0</Version>
<Level>0</Level>
<Task>12544</Task>
<Opcode>0</Opcode>
<Keywords>0x8010000000000000</Keywords>
<TimeCreated SystemTime="2014-10-10T01:49:43.563436300Z" />
<EventRecordID>37602685</EventRecordID>
<Correlation />
<Execution ProcessID="532" ThreadID="26096" />
<Channel>Security</Channel>
<Computer>***.net</Computer>
<Security />
</System>
<EventData>
<Data Name="SubjectUserSid">S-1-0-0</Data>
<Data Name="SubjectUserName">-</Data>
<Data Name="SubjectDomainName">-</Data>
<Data Name="SubjectLogonId">0x0</Data>
<Data Name="TargetUserSid">S-1-0-0</Data>
<Data Name="TargetUserName">***</Data>
<Data Name="TargetDomainName">***</Data>
<Data Name="Status">0xc000006d</Data>
<Data Name="FailureReason">%%2304</Data>
<Data Name="SubStatus">0x0</Data>
<Data Name="LogonType">3</Data>
<Data Name="LogonProcessName">
</Data>
<Data Name="AuthenticationPackageName">NTLM</Data>
<Data Name="WorkstationName">***</Data>
<Data Name="TransmittedServices">-</Data>
<Data Name="LmPackageName">-</Data>
<Data Name="KeyLength">0</Data>
<Data Name="ProcessId">0x0</Data>
<Data Name="ProcessName">-</Data>
<Data Name="IpAddress">***</Data>
<Data Name="IpPort">63664</Data>
</EventData>
</Event>Hi Tracy,
Have you changed something on your SharePoint 2007 environment recently before this issue occurred?
This issue may be related to Alternate Access Mappings settings like the following similar post, if you have configured AAM, you can check if this issue happened to some URLs, if it's the case, please add the problematic URLs as a Publish URLs for the default
zone for your web application, and also add these URLs as trusted locations, then check results again.
If above doesn't work, please enable ULS log on verbose level to get more useful log errors which time are corresponding to the errors occur.
https://social.technet.microsoft.com/Forums/en-US/c9ab4818-65c9-444d-be50-1bfed1f1509b/excel-web-access-web-part-works-on-intranet-but-not-internet?forum=sharepointgenerallegacy
http://blog.bugrapostaci.com/2011/09/08/how-to-enable-verbose-log-mode-on-moss-2007/
Thanks
Daniel Yang
TechNet Community Support
Maybe you are looking for
-
Error in starting WebLogic Server Process
Hi, I'm suffering a serious sproblem that results in failure in starting WebLogic Server Processes. What i'm trying is to use "PostBindUID" nad "PostBindGID" services that changes the processes owner from "root" to "somebody". However, once i set it
-
I need message to be displayed when certain key pressed. Why it's not working? import java.awt.*; import java.awt.event.*; import javax.swing.event.*; import javax.swing.JFrame; import javax.swing.JPanel; public class TestKey extends JPanel implement
-
How do I recover my Qosmio G20-118 without loosing data?
Hi there, I need to recover my system but have quite a lot of data in my D: HDD I would very much like to keep. In this forum, Gipsyman said that I should be able to use the dvd recovery disc selecting the advanced recovery mode, however there are a
-
How to use ipod mini calendar?
I own a ipod mini and i am not able to use the calendar. How can i create and delete events in the calendar? pentium 4 Windows XP
-
Hi experts, How to create tree node with folder symbol dynamically in alv tree control. Thanks Ramesh VR