Error Code = 1970, Error Source = SVL Power in Band (1 Ch).vi

What does error code 1970 signify when using the SVL Power in Band (1 Ch).vi?  Error status is false but error code is not 0.  Does this signify that the frequency range was coerced? 
Thanks

Hello eja,
You are correct about that code.  Because the Error status is false, that is a warning as opposed to an error.  You can look up the text that goes with the different codes in LabVIEW by going to Help >> Explain Error:
Please let us know if you have additional questions.
Regards,
Laura
Message Edited by Laura F. on 09-11-2006 10:40 AM
Attachments:
svcode.JPG ‏26 KB

Similar Messages

  • How do I make my error source look like standard LabVIEW codes?

    I have my error codes stored in an *-error.txt file.  I'd like to format the error source so it looks like a typical LV error source.  I've tried using an error code to error cluster and then either a simple or general error handler and I only get the error code, but the message has all the stuff I need.  I don't want to wire the message to the source, because that's not how LV error codes are normally displayed.  Am I making sense?  LV 7.1.
    Bill
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

    Yeah, I understand.  I have a vague question and I have to have help from you guys to even formulate it correctly.  Thanks, I will get back here soon!
    Bill
    (Mid-Level minion.)
    My support system ensures that I don't look totally incompetent.
    Proud to say that I've progressed beyond knowing just enough to be dangerous. I now know enough to know that I have no clue about anything at all.

  • How to resolve Error source: prompt.dll  Error code: 0x8004380D

    We have recently migrated from BOXI R2 to R3. All the Crystal Reports are working except the one which have dynamic filters. Whenever we refresh/view the report we get following error message:
    *Prompting failed with the following error message: 'List of Values failure: fail to get values. Cause of error: Failed to open the connection.
    Error source: prompt.dll  Error code: 0x8004380D
    The BOXI R2 server was 32 bit and the Crystal Report version was 11.0.0.1282. After searching here we upgraded the CR version on our R3 server to 11.5.8.826. The BOXI R3 server is Windows 2003 Enterprise x64 edition.
    This is the only roadblock we are facing for our successful migration.
    help!
    Edited by: daves11 on Jun 3, 2011 8:10 AM

    Moved to BOE Admin forum.
    CR and BOE should be the same version.

  • Transports while importing  DS error "Source system QAS does not exit "

    Hi Experts,
          For a specific reason we are importing a DS from quality to development.While importing DS in Development side we are getting an error " Source system QAS does not exist".Error message as  below:
       Start of the after-import method RS_ISMP_AFTER_IMPORT for object type(s) ISMP (Activation Mode)
       Source system QAS does not exist
       Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Activation Mode)
       There is no DataSource with these attributes
       Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Delete Mode)
       Start of the after-import method RS_ISMP_AFTER_IMPORT for object type(s) ISMP (Delete Mode)
       Start of the after-import method RS_ISCS_AFTER_IMPORT for object type(s) ISCS (Delete Mode)
       Start of the after-import method RS_ISTD_AFTER_IMPORT for object type(s) ISTD (Delete Mode)
       Start of the after-import method RS_ROUT_AFTER_IMPORT for object type(s) ROUT (Delete Mode)
       Errors occurred during post-handling RS_AFTER_IMPORT for ISCS L
       The errors affect the following components:
          BW-WHM (Warehouse Management)
       Post-import methods of change/transport request CXCK900023 completed
            Start of subsequent processing ... 20090306024549
            End of subsequent processing... 20090306024550
       Execute reports for change/transport request: CXCK900023
       Reports for change/transport request CXCK900023 have been executed
            Start of................ 20090306024550
            End of.................. 20090306024550
       Execution of programs after import (XPRA)
       End date and time : 20090306024550
       Ended with return code:  ===> 8 <===
    Our system sap bi is not new system, we are using from long time.Transports are working while moving dev to quality and quality to prod.
    Can any body suggest on this.
    Regards
    Vinod

    Hi vinod kumar,
    i hope you need to map source system From QAS to DEV system,
    genereally from DEV to QAS configuration will be there, but here request is moving from QAS to DEV so i think this should be configured.
    RSA1-> Tools -> conversion of logical system names -> maintain original system and target system name for both BI and ECC systems.
    Regards
    Daya Sagar

  • Error: Source system already exists. Message no. RSAR201. Points rewarded.

    Error: Source system already exists. Message no. RSAR201
    We have installed a BI 7.0 system recently and I am setting up the server to connect to SAP ERP.
    In TA SM59 a connection to the SAP ERP has been established. The “Remote Logon” is OK, (meaning clicking it nothing happens). The “Connection Test” is OK.
    According to the Best Practices paper: “B84: BI Connectivity” (B84)
    http://help.sap.com/bp_biv170/BBLibrary/documentation/B84_BB_ConfigGuide_EN_DE.doc
    I have done the following:
    In TA RSA1
    1.     Choose Modeling.
    2.     Choose Source Systems.
    3.     Select SAP in the window on the right.
    4.     Choose the Context menu (right mouse click).
    5.     Choose Create.
    6.     Make the following entries:
    Available destination: (The above tested connection)
    Background user in source system: RFCUSER (I created the user in ERP according to step 1.4 in “B84”)
    Password for source system: *****
    Background user in BI: RFCUSER (I created the user in BI according to step 1.4 in “B84”)
    Password for BI user: *****
    8.     In the dialog box Please log on as an administrator in the following screen choose Continue.
    9.     Log on to the Source System with your administrator user. Choose the correct client.
    10.     On the dialog box New Source System Connection choose Continue.
    THEN I GET THE ERROR:
    Source system already exists.
    Message no. RSAR201
    What is wrong? I cannot locate any SAP notes to help on this problem.
    Best regards,
    Carsten Pold

    Hello Carsten,
    just some guessing at this point...
    a)
    Is the connection really new? For example, was there another system connected to that ERP, maybe with the same logical name? Or was any of the two systems copied from another system?
    b)
    Authorisations issues in this process may result in strange error messages. Make sure that the admin user in step 9 really has SAP_ALL. There are a lot of complex activities that this user must be able to do (ALE management, RFC access etc.). To exclude issues with the RFCUSER users: If possible, give them SAP_ALL, too. Of course only temporarily for testing.
    c)
    I normally don't use existing RFC destinations. Usually, I let the system create those, too. So maybe it makes a difference if you remove the RFC destinations on both sides and try again. In that case, you will of course have to provide the RFC details when creating the source system connection...
    I hope this brings you forward a little...
    Regards,
    Christian!

  • Error 41 - Kernel Power in event log after clean shutdown - Windows 8.0

    HP Envy H9-1405A - 16MB RAM,  Windows 8.0, and up to date with updates. (16 months old but under extended h/w warranty).  All user data backed-up daily.
    After problems earlier today I noticed that after a controlled shutdown and start from cool (ie on/off button on PC, not mains power at the wall) the startup took over 10 minutes.  Event browser showed error 41 - Kernel Power - "after system crash or lost power unexpectedly",  which it definitely hadn't as I was testing a controlled shutdown.
    When starting from overnight sleep mode this morning it came up with  blue screen and an error mssage something like 'hard disk driver error', or similar (before first coffee so I wasn't really awake).  PC wouldn't restart in anything like reasonable time until powered off at wall, after which it struggled up and ran normally for a while.  Went out for a couple of hours and on return again the PC wouldn't re-start from sleep mode.  Again used the wall power switch to effect the restart and PC and after very slow restart it ran normally.  Event log showed Startup Repair ran due to a corrupted registry hive, and reboot used an earlier version.
    Checkdisk ran clean and the HP Support Assistant diags just looped for ever.
    I then tried a system restart, which worked but took a long time, and then a controlled power down and start from cool which also took a long time as described above.  I've temporarily turned off sleep mode so as to keep working.
    Question - do I have a transient software problem which might be fixable with Recovery, or failing hardware that should be covered by warranty, and where might I find some hardware diagnostics to show to the supplier?  Thanks.

    Hello @mikerb,
    I have read your post on how your desktop computer is displaying an error message in regards to a Kernel event log, and I would be happy to assist you in this matter!
    To further diagnose this issue, I recommend following the steps in this document on Windows Kernel event ID 41 error "The system has rebooted without cleanly shutting down first". This should help to resolve the critical error message.
    Just to be on the safe side, I also suggest following this resource on Testing for Hardware Failures (Windows 8); which should help determine if there is a hardware defect with one or multiple hardware components on your computer.
    Please re-post with the results of your troubleshooting, and I look forward to your reply!
    Regards
    MechPilot
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the right to say “Thanks” for helping!

  • When i download any file it start in a second but when i pause the downloading file & after some time when i open it amessage flash 'download error' source file could not be read please try again later or contact the server administrator.

    when i download any file it works frequently and downloading start in a second but when i pause the downloading file & after some time when i open it,The downloading not start proper and after some time a message flash 'download error' source file could not be read please try again later or contact the server administrator.

    I downloaded the Microsoft Autoruns package and ran it.  There are no programs in the LSA Providers tab, and Apple's Bonjour is the only program in the Winsock Providers tab.  I also did the "netsh winsock reset" and rebooted.  It didn't fix the problem.  Any more ideas?

  • Dell e6420 win 7 ent 64 bit - error source corrected machine check event id 19

    I have a user that is getting this error before it BSOD
    any help would be great
    Log Name:      System
    Source:        Microsoft-Windows-WHEA-Logger
    Date:          1/23/2014 10:33:22 AM
    Event ID:      19
    Task Category: None
    Level:         Warning
    Keywords:     
    User:          LOCAL SERVICE
    Computer:      EEXO1209.ga.local
    Description:
    A corrected hardware error has occurred.
    Reported by component: Processor Core
    Error Source: Corrected Machine Check
    Error Type: Internal parity error
    Processor ID: 0
    The details view of this entry contains further information.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-Windows-WHEA-Logger" Guid="{C26C4F3C-3F66-4E99-8F8A-39405CFED220}" />
        <EventID>19</EventID>
        <Version>0</Version>
        <Level>3</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
        <Keywords>0x8000000000000000</Keywords>
        <TimeCreated SystemTime="2014-01-23T15:33:22.370702000Z" />
        <EventRecordID>48325</EventRecordID>
        <Correlation ActivityID="{E060A63B-4EF5-45A1-9890-F70EF86F85EF}" />
        <Execution ProcessID="1544" ThreadID="5756" />
        <Channel>System</Channel>
        <Computer>EEXO1209.ga.local</Computer>
        <Security UserID="S-1-5-19" />
      </System>
      <EventData>
        <Data Name="ErrorSource">1</Data>
        <Data Name="ApicId">0</Data>
        <Data Name="MCABank">0</Data>
        <Data Name="MciStat">0xd000070000010005</Data>
        <Data Name="MciAddr">0x0</Data>
        <Data Name="MciMisc">0x0</Data>
        <Data Name="ErrorType">12</Data>
        <Data Name="TransactionType">256</Data>
        <Data Name="Participation">256</Data>
        <Data Name="RequestType">256</Data>
        <Data Name="MemorIO">256</Data>
        <Data Name="MemHierarchyLvl">256</Data>
        <Data Name="Timeout">256</Data>
        <Data Name="OperationType">256</Data>
        <Data Name="Channel">256</Data>
        <Data Name="Length">864</Data>
        <Data Name="RawData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ata>
      </EventData>
    </Event>
    Log Name:      System
    Source:        Microsoft-Windows-WER-SystemErrorReporting
    Date:          1/23/2014 10:36:44 AM
    Event ID:      1001
    Task Category: None
    Level:         Error
    Keywords:      Classic
    User:          N/A
    Computer:      EEXO1209
    Description:
    The computer has rebooted from a bugcheck.  The bugcheck was: 0x0000003b (0x00000000c0000005, 0x0000000000000000, 0xfffff88009795e40, 0x0000000000000000). A dump was saved in: C:\windows\MEMORY.DMP. Report Id: 012314-28516-01.
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-Windows-WER-SystemErrorReporting" Guid="{ABCE23E7-DE45-4366-8631-84FA6C525952}" EventSourceName="BugCheck" />
        <EventID Qualifiers="16384">1001</EventID>
        <Version>0</Version>
        <Level>2</Level>
        <Task>0</Task>
        <Opcode>0</Opcode>
        <Keywords>0x80000000000000</Keywords>
        <TimeCreated SystemTime="2014-01-23T15:36:44.000000000Z" />
        <EventRecordID>48342</EventRecordID>
        <Correlation />
        <Execution ProcessID="0" ThreadID="0" />
        <Channel>System</Channel>
        <Computer>EEXO1209</Computer>
        <Security />
      </System>
      <EventData>
        <Data Name="param1">0x0000003b (0x00000000c0000005, 0x0000000000000000, 0xfffff88009795e40, 0x0000000000000000)</Data>
        <Data Name="param2">C:\windows\MEMORY.DMP</Data>
        <Data Name="param3">012314-28516-01</Data>
      </EventData>
    </Event>

    Hi,
    To find the culprit, we need to analysis the dumpfile (C:\Windows\Minidump folder ).
    Please use Windows Live SkyDrive (http://www.skydrive.live.com/) to upload the dump files to a public folder and share the URLs with us.
    If you want to debug dump files by yourself, refer to that:
    http://support.microsoft.com/kb/315263
    For WHEA error 19 and 1001, please refer the links below:
    Event ID: 19 occurs on Windows Server 2008 or Windows Vista Service Pack 1-based computers that use Intel Nehalem processors
    http://support.microsoft.com/kb/961080
    That should apply to Windows 7 too.
    "0x0000003B" Stop error occurs in Windows Server 2008 R2 and in Windows 7 when an application or a service performs a GUI-related operation
    http://support.microsoft.com/kb/2359223/en-us
    Also the links below about error 19 and 1001 may be helpful to you:
    http://www.eventid.net/display.asp?eventid=19&eventno=9845&source=Microsoft-Windows-WHEA-Logger&phase=1
    http://www.eventid.net/display-eventid-1001-source-Microsoft-Windows-WER-SystemErrorReporting-eventno-10481-phase-1.htm
    Please Note: Since the website is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Please also update the BIOS and the display card driver to check the issue first.
    Then check the memory.
    Diagnosing memory problems on your computer
    http://windows.microsoft.com/en-us/windows7/Diagnosing-memory-problems-on-your-computer
    Hope it helps.
    Regards,
    Blair Deng
    Blair Deng
    TechNet Community Support

  • Transporting Process Chain - error  Source system does not exist

    Hi,
    I tried to transport a local PC by itself (not including its main meta chain) since I have only done modifications in the local PC only. In the PC, there are PSA Processing, ODS Processing, ODS Activation, ABAP Program w/ variants and Infocube Rollup.
    However, I got the following transport error: Source system does not exist
    =======
    Diagnosis
    Source system  is not known.
    System Response
    The imported data for DataSource  was deleted again because the referenced source system does not exist and no mapping is defined in table RSLOGSYSMAP on an existing productive source system.
    Procedure
    Create the referenced source system in the Data Warehousing Workbench or define mapping to a known source system in table RSLOGSYSMAP.
    You get to maintenance using Tools -> Conversion of the logical system names.
    ============
    I have checked at the table RSLOGSYSMAP and all source system mappings are in order.
    And the weird thing is, upon checking the PC itself in the transport-to box, I can activate it without any error.
    FYI, we are currently upgrading to BI Accelerator. Am not sure if this could be one of the reasons.
    Any inputs and tips are highly appreciated and will be rewarded with points accordingly.
    Thanks

    Hi,
    This error is due to the fact that the
    mapping table for the after import (RSLOGSYSMAP) is not correct maintained in PB7 system.
    You need to maintain table RSLOGSYSMAP in each system
    You can find the steps to do it in the attached note 127326:
    o  Maintain table 'RSLOGSYSMAP' in the target BW with view
       'V_RSLOGSYSMAP' and enter as 'original source system' the logical name of the source system in the source BW and as 'target source system' the logical name of the source system in the target BW.
       This maintenance is required since it allows the correct source system reference of the InfoSources to be transported.
    This source system reference in turn is absolutely necessary to activate the transfer structure.
       Example:
       Source BW with source system AAA.
       Target BW with source system BBB where the source system AAA
       corresponds to the source system BBB.
       Entry in RSLOGSYSMAP in the target BW:
       Original source system: AAA, target source system: BBB.
       Give the DDIC user in the source BW in client 000 the
       authorization profile S_RS_ALL to create BW objects.
    Cheers
    Rajesh

  • After transporting I get error "source system does not exist"

    Hello all,
    I have transported my objetcs to BW quality system and transported the data sources to r/3 quality and everything went fine. But now when I am trying to go through everything my update rules are inactive and when I get to infosource it gives me this error
    "Source system ERJ100 does not exist."
    Is there any importamnt step that I am missing why are the objects not recognizing the source system?
    Thanks,

    hi,
    check the system mapping in rsal tools system mapping tab as lilly mention. check if the mapping is defined correct. see the link below
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/e883de94-0501-0010-7d95-de5ffa503a86
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/3010ba90-0201-0010-2896-e58547c6757e
    Might help
    Thank you
    Qandeel

  • Error SOURCE IS the same as the target Task name Clear Cube Data

    Hi,
    When I am trying to use the Clear Package I am getting an error -
    "Source is the same as the Target"
    Any help with how to resolve this ?
    thx

    Hi,
    Please check if the Clear DM package is linked with the Process chain for Clearing the Data.
    We usually get the error you are mentioning in Copy Function when we have same source and Destination members.
    Hope this helps,
    Regards,
    G.Vijaya Kumar

  • How to remove the HTML formatting from error sources

    Does anybody have a good way to strip the HTML mark-up that often shows up in the source field of an error cluster.  I would like to log the error source to a text file, and display the error source in a text control, without the HTML mark-up.
    I'm using LabView 8.5, but I'm sure a solution for an older version of LabVIEW can be easily adapted to the latest version.
    Thanks,
    Mark Moss

    smercurio_fc,
    that is what I get on my system (Win XP Pro SP2, LV 8.0.1 and newer). If you see it different there must be something different between my and your system.
    Message Edited by waldemar.hersacher on 03-10-2008 12:45 PM
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions
    Attachments:
    HMTLinSimpleErrorHandler.png ‏11 KB

  • TO Error: Source HU ******* is not contained in Source storage unit *******

    Dear All,
    Our warehouse Handling Unit managed. I have created a delivery which is partially picked.
    After that when I am trying to create Transfer Order, I am getting an error "*Source HU ******* is not contained in Source storage unit ******"
    I am getting a pop up window in the name of "Enter withdrawal of Handling Units", and it is asking me to enter the Quantity to be repacked.
    I am getting this error only when I am doing Partial picking.
    How to get rid of this error. Kindly suggest.
    Regards,
    Mullairaja
    Edited by: MullaiRaja on May 26, 2011 10:47 AM

    Hello
    This can be the whole pallet have to be withdrawn from the source (flag LTAP-HOMVE is set on, 'X'), but HU picking control does not propose the source HU as the destination HU (flag LTAP-HUPIK is clear, ' '). Kindly check.
    If that is not the case then, for your reference refer following SAP notes:
    - 662020:      Processing of TO with different storage types
    - 514604:      Storage unit is not deleted when posting goods issue
    - 721901:      Errors LF-064, L3-848 while picking w/o pick-HU
    - 552073:      Message L3222 when creating transfer order with LT09
    - 505542:      Incomplete TO confirmation in Transaction LT0H & LT0I
    Thanks & Regards
    JP

  • HT201263 Error: source not supported. Why do I get this message when I try to play a video?

    Error: source not supported. Why do I get this message when I try to play a video?

    Did you copy the songs directly from a CD or did you download the files from a website?
    You can use a different player than the Windows Media Player to play the songs if you copied them from a CD to avoid that.

  • [E039(R9E)] Errors: Source 0P_RMA_CPER is not a permitted variable for targ

    Hi,gurus here.
    When I saved Query, it reported an error:
    [E039(R9E)] Errors: Source 0P_RMA_CPER is not a permitted variable for target Current Year Period.
    I never used 0P_RMA_CPER in query. How to find it and make it up?
    Thanks.

    Hi,
    Please log out  and login again.
    I had the same issue. above solution worked for me.

Maybe you are looking for