Error: Control parameters are not maintained in the current client

Hi,
We have recently installed IDES IS-H 6.04 - HEALTH CARE. In the SAP easy access menu when I go to Hospital>>Basic data administration>>Hospital structure>>Organizational Structure>>Organizational Unit>>Create it throws the following error message
"Control parameters are not maintained in the current client"
Any help on this would be greatly appreciated. I can't move ahead without getting to create an OU.
Warm Regards,
Prasoon Singh

Hi Prasoon
Are you starting from scratch?
Was the client created after the activation of IS-H?
For new installation I always recommend to activate the industry solution in client 000 and then to create the new clients as copy of 000.  It will bring you the configuration of the Institution 0001. If not, it's very hard to do all the customizing, specially the SD ones.
It seams that you have nothing configured, try to do the copy, if not, probably an entry in transaction ON05 is missing.
I hope it helps
With best regards
Matías

Similar Messages

  • The MRP parameters are not maintained in plant JK01

    Good morning,
    t-code : md04 (stock req.list) but got an error.
    MRP parameters for plant 'JK01' have not been maintained
    Message no. 61273
    Diagnosis
    The MRP parameters are not maintained in plant JK01.
    Procedure
    Maintain MRP parameters in Customizing.
    how to maintained mrp parameter fro plant JK01 ?
    Thank you.

    Hi Robert,
    First maintain the plant parameter using  tcode OMI8 for the plant JK01.
    this will solve ur issue.
    hope it wud have answered ur question
    reward if useful
    shawn

  • After updating to Yosemite, my screen saver settings are not maintained.  The screen saver reverts to some Apple default.  There is no way to get my setting to be maintained.

    After updating to Yosemite, my screen saver settings are not maintained.  The screen saver reverts to some Apple default.  There is no way to get my setting to be maintained.

    Hi ..
    Might be corrupted preferences.
    Open the Finder. From the Finder menu bar click Go > Go to Folder
    Type or copy paste the following:
    ~/Library/Preferences/com.apple.screensaver.plist
    Click Go then move the com.apple.screensaver.plist file to the Trash.
    Restart your Mac then reset your screen saver.

  • The page parameters are not showing in the URL .

    I my appliaction all the pages have textboxes with some values . But the URL for none of the page shows the parameters like every page has url :
    http://127.0.0.1:8080/apex/f?p=105:8:598450314306501::NO:::
    but none of the page parameters are being shown . What is the problem here
    please help

    You can setup a page branch that responds to your specific button and within that branch definition you can specify page items and values to be set when that branch fires.
    Is there a specific reason that you want the values passed on the URL? That's not really required to make ApEx function properly.
    Earl

  • Images are not rendered on the PIE03 Client

    Hi Team,
    I have a specific scenario where the Web Dynpro JAVA applications are deployed on Symbol Handheld devices (9090). The applications run fine on majority of the devices, but we have two handhelds where the PIE version 03 client is installed (we are passing the sap-wd-client=Pie03Client parameter). On these devices, the standard images pertaining to the table control UI like the paginator etc are not rendered. We are getting an "X" on the placeholder instead. Has someone faced this problem?
    Can you please provide some pointers? I have no clue as to what is missing here. Any help would be appreciated please.
    Thank you

    Hi Oliver,
    This is the online Mobile solution called "Mobile Webdynpro Online", it supports three clients.
    1. Pie03Client - for Windows Mobile devices.
    2. NokiaS80Client - for Nokia devices
    3. WMLClient - for Blackberry devices
    @Sanjay: can you check on your network speed?
    Best Regards,
    Karthik

  • Imported Pictures are not showed in the current path

    Hello
    i am using elements organizer 10 to organize my pictures, about 100.000.
    All these pictures are in the location D:/pictures/privat pictures/2001/YYYYMMDD. Each year has a lot of folders oriented by date.
    All this pictures are a second time at my backup drive Z:/backup pictures/privat pictures/2001/................
    After creating a new catalog and start importing all files from D: it takes time till all pictures are imported.
    But then the failure happens if i click to any folder in D: i can not see any picture.
    If i start import i.e. for one single folder again i get the message" pictures are already imported..."
    If i click at  a bar in the timeline the pictures are shown and the path tree shows it at location Z....with the path name from D:
    I created more cataloges the last time to find a solution but nothing helps to fix this problem.
    I use Windows 7 ultimate
    Any idea?

    Your description suggests you are facing the folder view bug in versions before PSE11.
    - In that situation you have no 'missing files' but the files appear in the wrong folder in folder view. Everything seems normal in thumbnail view and you can't reimport files because they are already in the catalog.
    For the confusion for the drive letter, it would be useful if you could check the serial numbers of both of your drives.
    In Windows, open a DOS command 'Vol D:' and 'Vol Z:' and compare the results. Are D: and Z: two physically different drives or different logical partitions ?

  • Server 2010 SP2 - New values in lookup table are not updated in the user client

    Hello,
    I added a value to a lookup table in the PWA.
    Most users see the new value in the field based on this lookup table.
    One user doesn't see the update for 2 weeks now. He did close and opened the application over these 2 weeks.
    Any Idea?
    Thanks,
    Barak

    Hi Barak,
    I am assuming the issue is with PWA? Has the user tried to access PWA from a different machine/browser?Other things you can try are:
    - Reset IE settings
    - CTRL+F5 (on the page)
    If it is MS Project that doesn't have the new value, try closing MS Project and re-open it
    Hope this helps
    Paul

  • Clearing Accounts are not maintained error during CAT7

    Hi All,
    I have got query related to CATS posting to CO i.e. CAT7.
    We are doing inter company CATS. While transferring data to CO, we are getting error that clearing accounts are not maintained for the set of company codes and posting key is not defined.
    We have maintained ZERO rate in KP26 for the year for which we are posting timesheet.
    My questions are:
    Can we post CATS to CO with ZERO rates maintained in KP26 for that year??
    When rates maintained in KP26 is ZERO then do we need to have clearing accounts maintained thorugh OBYA??
    Please reply with your expert comments.
    regards
    Nishith

    I think, i have posted in the right forum. I have seen similar kind of tread. CATS is considered under PS only.
    Please suggest if still i need to post in CO forum.
    regards
    Nishith

  • You are not connected to the internet error

    Recently, my old Apple iMac 9.1 - OS X V10.5.8 - stopped connecting to the internet with error message "You are not connected to the Internet".
    Having checked all other devices on the WIFI network, there seems to be is no reason for issue.
    Now utilising ethernet cable, but with same error message.
    Is there any I am missing or a possible virus closing out all connections ...
    Can someone please provide any guidance ...

    The rule is, your Mac will try to send packets bound for the Internet to the Topmost Interface on
    System Preference > Network
    Be sure to re-order them so that Ethernet is on top if that is what  you intend to use:

  • Parameters are not Passed in a Struts(JPDK) Portlet

    Dear All,
    I am getting below problem in Oracle Portal Environment(10.1.2)
    I am passing news_id parameter along with title from one page to another page like below code
    In CompanyNewsShowPage.jsp
    <tr>
    <td class="desc">
    <%
    page_url ="/showpageNews.do?news_id="+com_events[0];
    // System.out.println("value of page url : "+ page_url);
    %>
    <input type="hidden" value="<%=page_url%>" id="hdnpageurl"/>
    <pdk-html:link page="<%=page_url%>" styleClass="desc">
    <%
    String obj_title= com_events[1];
    if((obj_title.length())>30)
    out.println(obj_title= obj_title.substring(0,15)+ "...");
    else
    out.println(com_events[1]);
    %>
    </pdk-html:link>
    </td>
    TO passing
    shownews.jsp
    The code for accepting parameter is below
    <%
    System.out.println("value of newsid :"+ newsid);
    String news_id=request.getParameter("news_id");
    if(news_id !=null)
    newsid= Integer.parseInt(news_id);
    System.out.println("value of newsid :"+ newsid);
    %>
    Kindly any one help me how to pass the parameter from one page to another page above problem, because our go live date is very close.
    But same code it is works in IE browser, but not working after deployed in Oracle Portal Environment.
    However, the
    parameters are not passed from the form to the Struts action. When retrieving the parameters, then
    a null value is retrieved, even when the parameter was specified in the form.
    Regards,
    Chandrashekhara
    Message was edited by:
    user487286
    Message was edited by:
    user487286

    Hi Anton,
    I make some tests and it appeared that it's only the output parameter which is not passed through the step (why ?).
    I get this output parameter by a post-running action which parse the joblog and retrieve the sequence number at the line with the pattern  "vendor" (hereunder) :
    100601 20091008 00 516 Job started  0       
    100601 20091008 00 550 Step 001 started (program ZCO_MANAGE_FILE, variant ECLO2, user ID ABAPUSER)  0 001 ZCO_MANAGE_FILE ECLO2 ABAPUSER   
    100601 20091008 00 001 No vendor specified  0 00233      
    100602 20091008 00 517 Job finished  0
    Here is the postrunning action script wich was working before we upgrade :
      JobFile log = jcsJob.getJobFileByName("log");
      if (log != null)
        com.redwood.scheduler.api.search.SearchResultSet myResultSet = log.search("No vendor specified");
        com.redwood.scheduler.api.search.SearchResult myResult = null;
        while (myResultSet.next())
          myResult = myResultSet.getSearchResult();
          String [] line = myResult.getLineText().split(" ");
          JobParameter jp = jcsJob.getJobParameterByName("VendorCode");
          if (jp != null)
            jp.setOutValueString(line[line.length-1]);

  • T-Code J1INCERT:Acknowledgement number is not maintained for the quarter

    Hi Gurus
    While executing the T-Code J1INCERT, the system throws the following error:
    Acknowledgement number is not maintained for the quarter
    Message no. J1IN016
    But we have maintained the Acknowledgement number in Table: J_1IEWT_ACKN,
    Please throw some lights on it.

    Hi....
    You have to update to this table : J_1IEWT_ACKN_NUM or J_1IEWT_ACKN_N at quater level (Q1,Q2,Q3) ,after that you have maintain the number ranges  based on the Object name : J_1ICERT,J_1ICHLNNO, in SNRO t.code
    I hope will get solution...
    Regards
    vamsi

  • Node id does not exist for the current application server id

    Hi gurus,
    when i start application services (adstrtal.sh) i encounter the following error: Node id does not exist for the current application server id.
    i executed the command select server_id from fnd_nodes and had the following output
    SERVER_ID
    991D192B1CFC10F2E043C0A8645210F226563381082071204628231314463687
    i also checked the .dbc files under $FND_TOP/secure, there were two HOSTNAME_SID.dbc files (IPPDDVP_VIS.dbc and ippddvp_vis.dbc) with different APPL_SERVER_ID
    ippddvp_vis.dbc == 9827D18C8C2E8816E043C0A86452881611641850934523625093287478849136
    IPPDDVP_VIS.dbc == 991D192B1CFC10F2E043C0A8645210F226563381082071204628231314463687
    Please help me out.
    thanks.

    i cleaned the FND_NODES TABLE as per metalink note 260887.1. i run autoconfig on db/apps tier. Now when i start the application, i encounter the following error:
    applmgr >./adstrtal.sh apps/apps
    You are running adstrtal.sh version 115.19
    Executing service control script:
    /dvp2/product/viscomn/admin/scripts/VIS_ippddvp/adapcctl.sh start
    script returned:
    adapcctl.sh version 115.55
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Apache Web Server Listener is not running.
    Starting Apache Web Server Listener (dedicated HTTP) ...
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    Apache Web Server Listener (PLSQL) is not running.
    Starting Apache Web Server Listener (dedicated PLSQL) ...
    Cannot reconnect to gateway
    Cause: Application Object Library is unable to reconnect to your gateway ORACLE account after you unsuccessfully attempted to sign-on.
    Action: Check that your gateway environment variable is set correctly.
    adapcctl.sh: exiting with status 0
    .end std out.
    .end err out.
    please what should i do next to resolve this problem.
    thanks

  • SFLIGHT is NOT defined for the current logical database.

    I have just started learning ABAP and bought an ABAP Objects book by Horst Keller. I have installed 4.6d mini sap and SAP GUI 6.4 on win XP Prof. I executed S_FLIGHT_MODEL_DATA_GENERATOR to load DB tables.
    (1). When I tried to check a sample program, I get an error message SFLIGHT is not defined for the current logical database.
    Here is the partial code:
    REPORT zbcb01f1 .
    TABLES: sflight, sbook.
    DATA: BEGIN OF sr OCCURS 100,
          carrid LIKE sbook-carrid,
          connid LIKE sbook-connid,
          fldate LIKE sbook-fldate,
          bookid LIKE sbook-bookid,
          order_date LIKE sbook-order_date,
          loccuram LIKE sbook-loccuram,
          END OF sr.
    GET sflight.   <---- Error is pointed here
    (2). I am also not getting Graphical Screen Painter when selecting Layout for a screen. Instead, I am getting alphanumeric editor.
    Someone please help me.  
    Raizak.

    Hi Raizak,
    the easiest way is to go to service.sap.com/notes and enter the note number. For this time I've copied the 2 notes below.
    Best regards,
    Christian
    Symptom
    The Graphical Layout Editor of the Screen Painter either does not start or terminates.Error message 37527 is displayed in the session in which the call was made (Graphical Layout Editor not available.
    Additional key words
    () EUNOTE, EUSCREENPAINTER, 37 527
    Cause and prerequisites
    This note comprises all the common causes for error message 37527 and provides you with information on how to systematically trouble shoot the problem.
    1. Windows32 or UNIX/motif?
    As of Release 4.6B there is only the program version for 32bit Windows (NT, 95, 98, 2000 ff.).Up to Release 4.6A there was also a version for UNIX/Motif.All of the more current notes (with the exception of Note 45490) refer only to the Windows version.
    2. Termination at the start or during use?
    The following diagnostic steps refer to the causes of the errors which prevent the Graphical Layout Editor from starting. However, there are also known error causes, which result in the program terminating when the application is being used and which also produce the 37527 error message. This affects -
    Rel.4.6C/D: Termination when attempting to read texts in the logon language -> Note 375494
    Crash after transferring program and dictionary fields. Termination after transferring program and dictionary fields -> Note 189245
    Release 3.1I: Termination after inputting field text -> Note 113318
    3. Is the SAPGUI installation correct?
    The Graphical Layout Editor is automatically installed during the standard installation of the SAPGUI.If you chose a non-standard installation, then you should have explicitely selected its installation (component "Development Tools - Graphical Screen Painter").
    The program executable is called gneux.exe.During the SAPGUI installation it is placed in the same directory as the SAPGUI programms (for example, front.exe) (usually C:\Program Files\SAPpc\sapgui). The following belong to the program:
    - An additonal executable gnetx.exe (RFC starter program)
    - the DLL eumfcdll.dll
    - various eusp* data files (that is, the names all begin with eusp.)
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.
    4. System link defined and okay?
    The Graphical Layout Editor is a separate program which is started by the Screen Painter Transaction (SE51) on the Frontend machine.
    Up to Release 3.0F, the programs communicated with each other via the graphics log of the SAPGUIs (gmux).The definition of the environment variable SAPGRAPH may be the cause for the program not being being found where it is.
    As of Release 3.1 G, the programs use a separate RFC link which is set up in addition to the SAPGUI's RFC link.Missing or incorrect definitions of the RFC destination EU_SCRP_WN32 or problems with the creation of the RFC link are the most frequent causes for error message 37527 being displayed.Below you can find the correct settings for the RFC destination EU_SCRP_WN32 (under "Solution").Note 101971 lists all the possible causes for problems with the RFC link set-up. Attention:The Graphical Layout Editor may not be operated through a firewall (for example between the SAP and the customer system) because this does not allow an additional RFC connection in addition to the SAPGUI.
    Solution
    ad 1 UNIX/Motif
    Note 45490 describes possible errors resulting from an incorrect program installation under UNIX/Motif (up to Release 4.6A).
    ad 2 Termination when using
    The above-mentioned notes may contain options for solving individual problems.However, you usually have to replace the program with an corrected version.You can do this either by downloading a patch from sapservX or by installing a more current SAPGUI.The patch is mentioned in the respective note.
    ad 3 Installation
    You either need to reinstall the SAPGUI or manually copy the missing file into the SAPGUI directory.In both cases you should make sure beforehand that a Graphical Layout Editor is no longer running.To do this you can either remove all processes gneux.exe from the process list by using a tool such as Task Manager (on WindowsNT) or exit the Graphical Layout Editor from the Screen Painter Transaction menu via Edit -> Cancel Graphical Screen Painter). Attention:For each session or system an individial Layout Editor process may exist so that, if need be, several processes should be cancelled.
    ad 4 System link
    Up to Release 3.0F:you can either delete the environment variable SAPGRAPH or copy all the files of the Graphical Layout Editor into the directory which is specified by SAPGRAPH.
    As of Release 3.1G:you can use Transaction SM59 to check the RFC destination EU_SCRP_WN32 (expand the TCP/IP connections, select destination EU_SCRP_WN32).If the destination is missing, then you should create it with the following settings:
    - Connection type "T" (start of an external program via ...)
    - Activation type "Start"
    - Start on "Front-end workstation"
    - Front-end workstation program "gnetx.exe" (caution! NOT gneux.exe)
    - Description (optional) "Graph. Screen Painter (Windows32)
      Start Program gneux.exe using the gnetx.exe starter program."
    If you want to start the program from a different directory than the SAPGUI standard directory, then replace the default value under Frontend work station by the complete path name for program gnetx.exe.Transaction SM59 also allows you to check the RFC connection via the pushbutton "Test connection").In this case the system attempts to localize and start the program gnetx.exe.If there are errors, a message is displayed regarding the possible causes (for example, gateway problem, timeout problem or the like).Note 101971 provides a detailed explanation of the problems involved with an RFC connection set-up.As the Graphical Screen Painter requires a functional RFC connection as of Release 3.1G, contact the System Administrator or create an message on the topic Middleware (BC-MID-RFC) if you encounter RFC problems.
    If the program gnetx.exe can be found and started, the banner dialog box with logo, release data and version number is displayed briefly.As the Layout Editor itself is not started, the error cause must be in the installation of the Layout Editor program gneux.exe if the connection test was successful.
    Release 4.5A to 4.6B: Use with Releases <3.1G>.
    The Graphical Layout Editor is downward-compatible as regards the system connection, that is, an RFC-based Layout Editor for example from Release 4.6C can also be used on a non-RFC-based Screen Painter, for example of Release 3.0F.However, the releases mentioned above have a program error which causes a crash due to memory violation in the start phase of the program.Note 197328 describes the solution by installation of the corrected program version.
    Important: Trace file dev_euspNNN!
    If none of the diagnosis steps leads to the cause of the error and to the solution of the problem via the corresponding note, then you should add the contents of the trace files dev_euspNNN (NNN = process number) to the message for SAP, if possible.You can find this file in the current directory of the SAP System, for example under Windows NT in C:\Winnt\Profiles\<user>\SAPworkdir.If several such trace files can be found there, make sure that you use the file which matches the termination time with respect to date and time of creation.In most cases the ERROR message in the last lines of this trace file provides an important note on the cause of the error.
    Source code corrections
    Symptom
    The graphic layout editor of the Screen Painter cannot be started (RFC version).
    Other terms
    () EUNOTE, EUSCREENPAINTER
    Reason and Prerequisites
    This is generally caused by the fact that the RFC connection between the frontend graphics layout editor and the calling screen painter program at the backend cannot be set up.
    Possibility 1: Route permission denied
    In the trace file dev_eusp<Process Id> of the graphics layout editor you find the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR route permission denied (<Front-Id> to <BackId>,<Service>)".
    If there is a firewall between frontend computer and application
    server, you need to decide whether the port for the RFC of the graphical layout editor can be released here (see Solution 1 below).
    In case no firewall exists between the frontend computer and the application server, in its route permission table, the SAProuter contains either no entry for the frontend computer, on which the graphics layout editor is started, or the entry says that the link is saved by a password.Since the connection is denied, the graphics editor processes exits again, and the screen painter switches to the alphanumeric layout editor.
    Possibility 2: Service 'sapgw<ServiceId>' unknown
    In the trace file dev_eusp<ProzessId> of the graphics layout editor you have the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR service 'sapgw<ServiceId>' unknown".
    The service sapgw<ServiceId> (for example, sapgw00) is not known on one of the computers participating in the RFC communication because the corresponding entry is missing in its service file. The affected computer can be the frontend computer or the gateway computer.
    Possibility 3: The system parameter gw/cpic_timeout value is too low
    This system parameter determines how many seconds the gateway is waiting for the RFC connection to be set up.In case of a high network load, the default value of 20 seconds is too small with the result that the connection cannot be created on time.Here the graphics layout editor process also exits with the trace file entry "ERROR in RFCMgr_accept: not accepted".
    Possibility 4: System parameter abap/no_sapgui_rfc set
    The profile parameter abap/no_sapgui_rfc of the system is set (that is, it has a value not equal to space or 0).This prevents the program of the graphics layout editor from being started with RFC at the frontend.
    Possibility 5: Unnecessary authorization check
    The error message "No RFC authorization for user xxxxxx" is generated although the check of the RFC authorization was deactivated by profile parameter auth/rfc_authority_check (value = space or 0). The problem is caused by a program error, that ignores the value of the profile parameter let during the call of the RFC authorization check (see Note 93254). This error can occur as of Release 4.5.
    Solution
    ad 1) If a Firewall is installed between frontend computer and the application server, you need to decide whether the port for the RFC link of the graphical layout editor shall be released in the firewall. This is port 33nn, where nn is the 2-digit system number of the SAP application server. As of Release 3.1G, the graphical layout editor needs an RFC link for communication with the application server in addition to the already existing linkof the SAP GUIs. Such a second link is not allowed by the firewall in general because it would contradict the security concept (password protection, logging of the connection).
    If no firewall exists, you should check whether the frontend computer can be added to the route permission table or whether the password option can be removed from out of the available entry.
    For details refer to chapter 4.4 of the attached Note 30289.
    ad 2) Include service sapgw<ServiceId> in the service file.
    Refer to Note 52959 for details.
    ad 3) Increase value for system parameter gw/cpic_timeout. 60 seconds should be sufficent as a timeout limit.
    ad 4) Set the system parameter abap/no_sapgui_rfc to space or 0
    Start the application server so that the new parameter value comes into effect.
    ad 5) Import the Support Package specified in the attachment for the release in question or implement the advance correction in the source code as described in the attached correction instructions.
    As a workaround, assign RFC authorizations as described in Note 93254.

  • Requested query does not exist on the current server.

    Hi All,
    I am facing a problem in BI 7.0 related to query view.I am able to create a view on a query and can successfully save it .But when I am trying to open it using Bex Analyzer, it throws an error that query does not exist on the current server.
    Please find the steps below which I did to create a query view in BI 7.0.
    1.Executed query and then clicked on save from the tool bar.It asks me to save as workbook or save as view.I clicked on save as view and gave some name to view.It saved successfully.
    2.Now when in Bex I am trying to open the view , it gives the message 'The requested query does not exist on the current server'.
    Please help me in solving the issue.
    Regards,
    Phani.

    Hi,
    I am facing the same problem, though some others of my views can be opened.
    We had an upgrade of the system to Support Package stack 13. Maybe this caused problems.
    My BEx Analyzer Version is:
    Support Package 14, Patch 3, Revision 811
    Philipp

  • Error Message : Condition type is not maintained in the schema RM0002

    HI Gurus,
    I have created a new purchasing procedure as follows.
    ZVATV : <b>Condition Schema</b>
    VATV  : <b>Condition Type</b>
    VA : <b>Sch.Grp Vndr</b>
    When I create the Purchase order, the above mentioned schema, ZVATV is automatically determined.
    But when I create Contract, system throws an error message saying condition type VATV is not maintained in the schema RM0002.
    I am very new to SAP, Kindly explain in very detail about this error message and ways to get rid of it.
    If u have got any <b>very detailed material</b> about pricing kindly forward it to my mail id: [email protected]
    Thanks in advance.
    ~Gokul.

    Hi,
    The new condition type you are specifing is the gross price condition (PB00). for PB00 condition type a supplementary pricing procedure is assigned as RM0002. u may have copied the PB00 and changed it to VATV, but with out changing the RM0002. copy the RM0002 and in that also change the PB00 to VATV. after this go to VATV condition type control data (M/06) and assign the new supplementary pricing procedure instead of RM0002.
    The supplementary pricing procedure is required to have the condition types for which no access seqeunce is mentioned. All the condition types in main pricing procedure with out access sequence needs to be mentioned in supplementary pricing procedure.therefore all these condition types will have the same validity periods as PB00.
    Regards,
    Ramakrishna

Maybe you are looking for

  • MDM iviews in Portal throws error in key Mapping

    Hi, I have EP7 with SP15 and MDM 6.0, recently upgraded. Before upgrade we have an application which uses the MDM iviews and maps the fields of one table to other and displays in some other iview. The application was working fine before upgrade of MD

  • Movies on networked server stuttering on playback

    I'm using Mac Mini with a Core Solo processor as a media center. I have all my movies stored on a PowerMac G4 in another location in the house. Both systems have Gigabit ethernet ports and are connected with Cat 5e cable using a Gigabit switch. I hav

  • Desktop folders + icons moving after startup

    Some (but not all) folders and icons on my desktop change position each time I start-up. It is always the same folders & icons and they always move to top right of my screen. How can I stop this? It make no difference I use sort by > align to grid or

  • HT1349 Connect AP express to excisting wifi networkrouter? How?

    When I try to connect the AP express to my excisting network I get the folowwing message: can't detect airport base. What should I do?

  • Install Java Add-in for ABAP BW 3.5

    I have a System on which we have 3 SAP Instances 2 Instances of SAP R/3 4.6D 1 instance of SAP BW 3.5 I want to add a New Java Instance for BW and it is giving error during the installtion that Collation needs to be CP850_BIN2 I will appreciate if an