Hello,
when I try to overwrite an existing scale with the VI "DAQmx save scale.vi" I get an Error -200356. The parameter "Overwrite Existing Scale?" is set to "true".
I've create the scalinig before with the condition "Allow Interactive Deletion?".
Hello,
the Problem is solved:
Are you using the DAQmx Create Scale vi as well? It is actually not possible to create a scale with the same name as an existing scale. However, you can still modify and save an already existing scale. For an example of how to do this, check out the following link: http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=F38DB14830876FE6E0340003BA7CCD71&p_node=201209&p_source=External
Thanks a lot.
Similar Messages
-
Fehler "DAQmx Save scale.vi"
Guten Tag,
bei dem Versuch eine existierende Skalierung mit dem VI "DAQmx save scale.vi" zu ändern erhalte ich die Fehlermeldung -200356.
Der Parameter "Overwrite Existing Scale?" ist dabei auf "TRUE" gesetzt.Hello,
the Problem is solved:
Are you using the DAQmx Create Scale vi as well? It is actually not possible to create a scale with the same name as an existing scale. However, you can still modify and save an already existing scale. For an example of how to do this, check out the following link: http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=F38DB14830876FE6E0340003BA7CCD71&p_node=201209&p_source=External
Thanks a lot. -
I tried to increase the number of instances for an Azure WebApp (DNN website) from one to two.
I got the following error:
Failed to save scale setting. Not enough available reserved instance servers to satisfy this request. Currently 0 instances are available. If you are changing instance size you can reserve up to 0 instances at this moment. If you are increasing instance
count then you can add extra 0 instances at this moment.
Is this related to my configuration within Azure, or the Data Centre (we are using North Europe), or some other issue ?Hi EddyCromption,
What is the App Service plan pricing tier for the website ? If it is Free, recommend you to try upgrading it to Shared / Basic / Standard and try increasing the count.
You will not be able to increase the instance count for Free tier.
Please share the website url if you think, Pricing tier is not the issue.
Regards,
Shirisha Paderu -
A quick background, we are using create custome scale to convert bar to volts for the AO channel on a 6723 card. Which is working fine, we are able to set m and c values that convert nicely. An added 'feature' we are using is to be able to compensate for inaccuracies in the system (tolerences on transducers,wire resistences etc...) and hence claibrate the system by using a accurate sources/DVMS and again this is working well apart from one channel.
Due to the way the tolerences have worked out and the ranges are slightly different. i have 0-10bar and 0-10v, which in a perfect world would mean m=1 and c=0. using these values gives us ok (ish) readings. To bring the readings in I need m to be nearer 0.98 and the FSD to still be 10. If I set m to this value the FSD becomes 9.8. The post scaled min and max is calculated from m and c by using the pre scaled range.
this is giving a problem that once m<1 the daqmx scale becomes invalid and hence the channel is effectivly disabled. Any suggestions would be much appreciated
Sorry if the explaination is a bit vague ive only just got it straight in my head what is happening
Thanks in advance for any suggestions
Please remember to accept any solutions and give kudos, Thanks
LV 8.6.1, LV2010,LV2011SP1, FPGA, Win7Hello Akiel,
I have been looking at your problem and just want to clarify a couple of points.
From what you have said, I think you are using the DAQmx Create Scale VI in LabVIEW.
I believe you are using the linear scaling option. Is that right?
When you say it becomes invalid and hence the channel disabled, do you get a specific error message pop up? It seems strange to me that you are not able to use a value of m < 1 as an input to the function.
Thanks
Dom C -
When I try to export the file in word, I get the error "The Save as command has not been able to develop this document. Unable to create file".
Win7 Pro, 64bit
Acrobat XI Pro, tryalCreate a one word pdf file. Try converting to word. If that fails, try a complete uninstall, run the cleaner tool, then re-install.
Download Adobe Reader and Acrobat Cleaner Tool - Adobe Labs -
How to use DAQmx Create Scale Linear
Hello. I have an output from an amplifier that is 10mV/V, that is being read by an USB-6002. The voltage range for this amplifier is 0-200 volts. I have been testing the DAQmx Create Scale Vi but do not understand how it works. I have looked at other posts here for answers but am still not clear how this works. To begin with, it says it uses the y=mx+b equation for it. I don't know what the slope is referring to unless it is the angle of the line. If someone might have an example that explains how this works, that would be awesome. I also tried looking at an example but couldn't find one. Thank you
Here's a "seat-of-the-pants" explanation of y = mx + b. If you think of "x" as the input, and "y" as the output, then you can consider "m" as the gain, and "b" is the offset, the output that you would read with zero input.
If you think about this equation with respect to an amplifier, many are designed to have zero output when there is no input. This means b = 0. If you have a gain of 10mV/V (which I assume means that a 1V input would give a 10mV output, then m, usually called "the slope" (which is the slope of the input/output curve), would be .010/1 = 0.01.
Note you describe the range of your amplifier as 0-200V, so the output will be 0-2V, well within the ±10V of the USB-6002.
Bob Schor -
Hello Colleagues, I am creating an analysis in build 576, everything goes well, the algorithm calculates the needed values, but when I try to save the analysis, I receive the following error message: "An error occurred: Save document failed / An error occurred while saving the document: <PATH> (HDB 00055)".
Does anyone know what could cause this error message?
Thanks a lot for any hint.
SergeyHi Henry,
I am using PA 1.0.11 and received this error; any update on this fix for SAP PA. Does this happen for a particular data source.
I am currently using Excel as source and whenever I try to use this data; I get this even if I move the data to a new file or rename a file. I tried to check the same issue with a different file and it works fine. This file worked fine a day back.
Please let me know if this is unusual for this version.
Regards,
Arvind E -
Error: Excel encountered errors during save. However, Excel was able to minimally save your file to c:\users\*****\appdata\roaming\microsoft\excel\***.xlsb.
Basically, these are multiple macro enabled spreadsheets from one client. It happens with no other clients who also use macros. They are all saved to our network, which has plenty of space. Any of our users that access these files have the same issue.
Hi
Take following steps to troubleshoot the issue:
Check the Macro and File Blocker settings in the Trust Center.(File>Option>Trust center>Trust center settings)
Then we suggest to perform a clean startup to determine whether background programs are interfering with your Office program.
http://support.microsoft.com/kb/331796
It is recommended that you disable Antivirus application while checking the issue.
Regards
Tylor Wang
TechNet Community Support -
Why do I receive Error 200378 "Custom scale specified does not exist"?
I am trying to perform offset nulling using an NI-9237. I receive and error in regards to the custom scale even though I programmatically create the scale prior to the task. I am experiencing the erro whne using LV8.2.1 but with LV8.6 the problem disappears (same code, just open in LV8.6 and run)
The error is the following:
Error 200378 "Custom scale specified does not exist"
Possible reason(s):
Measurements: Custom scale specified does not exist. Custom Scale: test
Channel Name: LoadCell_StrainGage_Sim/ai0
Task Name: _unnamedTask<F>
I have attached the code in LV8.2.1
Thanks
Dan
Attachments:
test.vi 38 KBDan,
I tried your VI and it worked for me after I changed the channel from "LoadCell_StrainGage_Sim/ai0" to something that was on my system. Before that, I got the same error. So...are you sure that there is LoadCell_StrainGage_Sim/ai0 configured in MAX? Stupid question, I know, but it was the only thing I changed.
-Matt
-Matt Bradley
************ kudos always appreciated, but only when deserved ************************** -
Access Privileges error, cannot save library
I have had my iPod for 4+ years but after upgrading software about a year ago, I repeatedly get the error "Cannot save Library. You do not have enough access privileges." I have followed recommendations in previous threads to unmark the read-only button but to no avail. Very frustrating. Please help before I switch to a Zune.
That error is referring to the iTunes Library.itl or .xml file, as explained in this article:
http://docs.info.apple.com/article.html?artnum=93732
WHen are you seeing this error, when you try to close itunes?
Can you rename that file? Because if you can't, the operating system is confused and thinks something has a lock on it. Restarting your PC should clear that situation. -
Error while save framework purchase order.
dear all
i am working SAP R/3 4.7 ides while creating framework po, i input all the data field correctly , but when i am going to save the purchase order, it given the error Massages " Indicator for invoice receipt used not allowed
Message no. MEPO026"
then i tell me how i save the po. i request to all the expertsDear,
What account assignment you are using?
Use account assignment category as K and item category as B Also do not enter material ID.
Now try.
Regards
Utsav -
Workbook error 310 - save not possible
Hi,
when I want to save a workbook I receive error message 310 - saving not possible. Nothing in my authorizations where changed. In sdn I found also no hint.
Any idea?Hi,
Please check out the SAP Notes in the link:----
Error 310 when creating an workbook
REgards,
Suman -
Error When Save Message Mapping
Hi evreybody,
I try to save my mapping. I did the test to check to know if everything is ok. The test is executed succesfully but when I try to save, I receive the following error message:
Internal error: Unable to transfer changes for object Message Mapping MM_Order_Idoc | http://accenture.com/PI01/Idoc to change list "Standard Change List" (348cd3a0-f384-11dd-c70e-003005989c0a) since object still in change list "Standard Change List" (faa66160-f699-11dd-8a1b-003005989c0a)
Thank you for your support,
Mohamed.Release the lock by going to XI Admin page and check Integration repository and lock tab where you can see the objects locked ,release the lock and you can do the needed.
Rajesh -
Automater error using Save as Adobe PDF w/ Acrobat 9 on OS 10.7
Hello,
Do you use 10.7 or do you use 10.6?
In my situation, save as Adobe PDF (Acrobat Pro 9) worked perfectly in 10.6 but gives an Automator error under 10.7.[Something went wrong: my post was a question to WLV_Jim2 (jun 21, 10:56 AM)]
I started all over again:
I erased my hard disk. I installed Lion (again). I installed Acrobat (again). I did all the 19 updates, one by one (agian).
Now it works. Ouf. -
ERROR for save a form created in XML Form Builder
Hello everyone:
I am having an error message when I try to save a form in the XML form builder and I donk know what I need to do for fix it.
Warning:
An error occurred when copying temporary files. The saved project state can be opened in the XML Form Builder, but the old state will be generated. The error was: An unexpected error occurred: null.
If anyone knows how to fix it I'll thanks your help!
TzitziHi, someone can help me with this?
Maybe you are looking for
-
Migration Assistant has been running since yesterday evening. My Dell is now telling me that its trying to reconnect to my Mac and to ensure they are both using the same network. I have an Ethernet cable plugged in them and they are both on the sam
-
My computer can't start the AMD due to error message 1053.
This started after I tried to install the new update that came today. I uninstalled iTunes and when attempting to install it again, it failed. The icon is there but when I try to open it a message comes up saying that it can't find it.
-
Purchasing price variance report
dear all, I have to generate the purchasing price variance report... Report to analyze and compare the following data elements from the invoice and standard cost:Period Actual average price per unit.YTD actual average price per unit o current year.YT
-
Error con el DTW en SQL Server 2008
Buenas tardes... Bueno, la cuestion es la siguiente, estoy intentando de realizar una subida de plantillas por el DTW, a SAP 2007 SP 01 PL 10 pero cada vez que le doy a "run simulation" o a "importar" simplemente se pone la pantalla del DTW mas clara
-
How to improve signal strength of TC ?
I have replaced my Linksys WRT54G Router yesterday with my TC 1TB. Setup was a little bit confusing and not Apple like as i expected. However i got TC running with the following setup: -) the TC is connected to my broadband modem and my main imac via