Error generating form on Designer 6i
Hi folks:
I got a new PC.
It comes with a AMD Atholon Processor.
I am trying to test all the Oracle Products.
But I am getting a Designer error, related with a forms generation:
CDR-21605: Failed while processing.........
I was looking on these forum but I can not find any solution to my problem.
Few months ago, my currect PC needs to be re-format to installed all the Oracle products.
All the installation was sucesfully installed and not even one product failed.
I don't know what could be the reason of the erro i mentioned before.
My PC has 2Gb of RAM.
Some friend told me something about the pagging file size......
I don0t know.
Best regards.
Abdel Miranda
Hello there:
The full error message is this:
CDR-21605: Failed while processing in function InitGlobals BOF
Reported Messages:
CDR-21605: Failed while processing in function InitGlobals BOF
Cause: The generator failed due to an unexpected error - the error indicates the object the generator was processing when it failed.
Action:
The message on Designer Message Windows is:
Form Generator (Windows 98/NT/2000/XP) : Version 6.5.93.2.9 - Production on Wed Jan 28 08:11:59 2009
Copyright (c) 1995, 2003 Oracle Corporation. All rights reserved
An internal error has occurred, context and traceback follows...
Last CV function: InitGlobals
Current preference object: Application System BLD1_PROD (1)
Generation Complete
Not a clue about which is the real message or which action can we take to resolve.
Any ideas.
Abdel Miranda
Panama
Similar Messages
-
Generating forms from Designer... bug?
Sorry for offtopic....
I'm trying to generate form from designer. The form has 1 data module with base table & one lookup table usages. One field from lookup table is displayable. When I set "Display type" property of this field "Text" disigner says: "CDI-21600: A running utility.. etc." BUT when I set "Display type" property of this field "PopList" - everything goes well! I don`t even need to restart designer. This is .log from designer
Form Generator (Windows 95/NT) : Version 5.0.24.13.0 - Production on Wed Apr 25 10:14:34 2001
Copyright (c) 1995, 1998 Oracle Corporation. All rights reserved
Generating Module 'Q20010' (1 of 1)
Loading form template from file system (d:\work\libs\tpl_lov.fmb)
Loading object library from file system (d:\work\libs\dob_olb1.olb)
Block NE based on table
6 row(s) automatically chosen
-- (Error happens at this stage) --
Generation Complete
All fields from base table are binded.
Sysinfo:
WinNT 4.0.WS Rus SP6a HE
Oracle Designer (rel. 2.1.2) 7.0.24.2.0
Developer/2000 Forms 5.0.6.14.2
GUI Common files 6.0.8.12.1
Form Generator 5.0.24.13.0
P.S. I hope i've explained my problem clearly. If somethig is not clear, pls e-mail me.This is from http://metalink.oracle.com/ site - Technical libraries - Oracle Designer - Collected CDI-21600 errors,fixes and workarounds:
The CDI-21600 error message means that the generator is hitting an unhandled
exception, also known as a GPF (general protection fault). The CDI-21600 error
masks the underlying exception error. To see the real error do the following:
1. Go into the Registry Editor (REGEDIT).
2. Navigate to HKEY_LOCAL_MACHINE\software\oracle\des2_70
3. Set EXCEPT_HANDLING to 0 (by default it is 1).
Repeat the action that resulted in the error.
I have read this article and it seems that there is not such bug, but ... ?
Maybe this will be a little help for you.
Helena -
Error while generating forms from Designer 2000
Hi,
The following error was encountered while trying to generate forms from the Designer ( using Design Editor ) .
CDI-23564 : "C:\ORAWIN95\BIN\CF50G32.DLL" could not be loaded or does not exist . Please check that the product has been installed correctly .
But the specified dll actually exists in the specified path .
Pls clarify ( send mail to [email protected])
Thanks
Eugene Xavier
nullThis is from http://metalink.oracle.com/ site - Technical libraries - Oracle Designer - Collected CDI-21600 errors,fixes and workarounds:
The CDI-21600 error message means that the generator is hitting an unhandled
exception, also known as a GPF (general protection fault). The CDI-21600 error
masks the underlying exception error. To see the real error do the following:
1. Go into the Registry Editor (REGEDIT).
2. Navigate to HKEY_LOCAL_MACHINE\software\oracle\des2_70
3. Set EXCEPT_HANDLING to 0 (by default it is 1).
Repeat the action that resulted in the error.
I have read this article and it seems that there is not such bug, but ... ?
Maybe this will be a little help for you.
Helena -
Cfg61.dll - Cannot generate forms from Designer
Hi
When I try and generate a form from Designer 6i (i am using the tutorial app) i get the following error message :- CDD-23564 : The file "g:\orant\BIN\cfg61.dll" could not be loaded or does not exist. However the file does exist in the specified location. Ive looked thru the on-line documentation and checked the registry but cant see anything obvious. Ive got the following configuration on my machine :-
Windows NT 4 (service pack 3)
Oracle 8i (version 8.1.6)
Designer 6i (version 6.5.28.8.0)
Any advice would be welcome.
Thanks
nullThe configuration looks ok except for Th eService Pack. Designer requires Service Pack 5 or 6 or Wondows 2000 Service Pack 1. Try changing the Service Pack.
All the best -
Hi, Everybody
I’m new in designer
I finished my first ERD and convert it to physical tables and
indexes By (database design transformer) that’s OK , and when I
entered Design Editor I found those tables Ok ,
My problem: I want Designer to generate forms for this tables ,
I entered Navigator Window then I choosed Modules tab and then
Reusable Module Components and I lunched it Ok to select all
items to be displayed BUT I COUNDN’T FIND ANY FORMS WAS
GENERATED
HOW CAN I GENERATE FORMS ?
By the way: I don’t want to generate any Functions in designer,
I have developer2000 on my machine , and I use Designer 6I Ver
6.5.4
THANKSIt is difficult from your question to understand exactly what you
have done. I will attempt to outline the general process. All the
steps listed will be done from the Design Editor.
1. Assuming you have your data model defined in Designer
including primary keys, foreign keys, domains etc.
2. Use the server generator to create you data model in your
target database
3. Create a module for each form
4. Create a module component for each block you want to generate
(note for more advanced generation you may have sub module
components)
5. For each of the module components you need to define the
tables the block is based on and the items required. Each item
will either be bound to a column or be un-bound, i.e. non db item
6. The next step requires a reasonable degree of knowledge, I
suggest you read the help or a good Designer book. To get the
layout and functionality you require you need to use a
combination of the layout properties, preferences, templates,
application logic and layout tab editor settings.
7. Once you have done this you run the forms generator for your
module and unless you get generation errors you will end up with
a .fmb. (Make sure that the version of Forms you have is
compatible with the version of Designer)
8. You should expect to repeat steps 6 and 7 a number of times to
get the form you want.
I hope this helps
Regards
Mark -
CDG-03516 ERROR: While generating form in Designer 10g
Hi Gurus,
We have recently migrated from 9i to 10g. We are not able to generate few forms and getting the below error message:
"CDG-03516 ERROR: Module NSP0070: This module contains or references an object outside of the current workarea"
We found that for one of the table there is an entity which is shared from another container which was excluded in the workarea.
We have the same entity in a different container that exists in the workarea.
Any idea how to change the reference of the entity from the old excluded container to the current container that exists in the workare without much impact.
Thanks in advance for your solution.
Regards,
VinodhAn Entity should not matter.
You need to have the tables generated before you can generate a form.
If you are now missing a table then that will stop the form generation.
Michael -
Error Generating Form against external application database
I'm hoping the answer to this is simple, as others in the office can do this without any trouble, but can't remember how they made it work...
My client has their repository and application schemas in separate databases. When I try and generate a form from the Design Editor, I get the following error:
CDG-01281 ERROR: Module OASF95110: Oracle Forms binary file for MAINTAIN TARIFF AGREEMENT has NOT been created
CDG-03418 WARNING: Module Component OASF95110.TARIFF_AGREEMENT: Missing action item to navigate to 'TARIFF_AGREEMENT_PARTNER'
CDG-03400 WARNING: Module Component Table Usage OASF95110.TARIFF_AGREEMENT.TARIFF_AGREEMENT.TARIFF_AGREEMENT: 'Closed loop' of mandatory foreign keys found
CDG-01263 ERROR: Module Component Table Usage OASF95110.TARIFF_AGREEMENT.TARIFF_AGREEMENT.TARIFF_AGREEMENT: User-defined condition (Table level Check Constraint TARIFF_AGREEMENT.TRFA_CK1) has an error: PL/SQL: ORA-00942: table or view does not exist
What I seem to be missing, and have not been able to locate in any documentation, is how to tell Designer to look in a different database for the (already generated) schema objects.
In a copy of the repository where I have generated the necessary objects into the same database as the repository, the form generates flawlessly...Tried that... Turns out the system uses the "Compiler" tab for validation, not for "Form Options" tab - It took a while, but one of the other developers finally remembered what they did and actually compared the screen prints I was providing with what they had in their environment...
Thanks :) -
hi all,
i try to generate forms from designer and i have the following error
CDG-01338 ERROR: Module test: Failed to load form F:\Ora9iDSHome\CGENF61\ADMIN\ofgwebt.fmb
i verify that the form ofgwebt.fmb exists in the directory F:\Ora9iDSHome\CGENF61\ADMIN. i don't know why it doesn't load this form
i need help
thanks in advanceThere may be some problems with your template. For example your template has a PL/SQL library or an Object library wich cannot be found. Therefore open the template in Forms Builder.
Regards,
Harm -
Generated Forms does not compile - NEXT ITEM and PREVIOUS ITEM procedure not found
I tried to generate forms using Designer 6i.
FMB was created, but there are compilation errors.
The Compiler can not found procedures called CGNEXTITEM and CGPREVIOUSITEM.
Judging by the names, those procedures are supposed to be generated by designer as well,
but there are no codes with the names.
Any idea?
YusanIs your temporary table created with the clause "on commit preserve rows" or "on commit delete rows"?
If it's the latter then try changing to the former as you have a commit in the middle of your code, doing this will keep the data in the table for the duration of the session.
If you need to clear the table of data within your session, you'll have to do an explicit delete.
Ady -
Generating forms.... bug?
I'm trying to generate form from designer. The form has 1 data module with base table & one lookup table usages. One field from lookup table is displayable. When I set "Display type" property of this field "Text" disigner says: "CDI-21600: A running utility.. etc." BUT when I set "Display type" property of this field "PopList" - everything goes well! I don`t even need to restart designer. This is .log from designer
Form Generator (Windows 95/NT) : Version 5.0.24.13.0 - Production on Wed Apr 25 10:14:34 2001
Copyright (c) 1995, 1998 Oracle Corporation. All rights reserved
Generating Module 'Q20010' (1 of 1)
Loading form template from file system (d:\work\libs\tpl_lov.fmb)
Loading object library from file system (d:\work\libs\dob_olb1.olb)
Block NE based on table
6 row(s) automatically chosen
-- (Error happens at this stage) --
Generation Complete
All fields from base table are binded.
Sysinfo:
WinNT 4.0.WS Rus SP6a HE
Oracle Designer (rel. 2.1.2) 7.0.24.2.0
Developer/2000 Forms 5.0.6.14.2
GUI Common files 6.0.8.12.1
Form Generator 5.0.24.13.0
nullThis is from http://metalink.oracle.com/ site - Technical libraries - Oracle Designer - Collected CDI-21600 errors,fixes and workarounds:
The CDI-21600 error message means that the generator is hitting an unhandled
exception, also known as a GPF (general protection fault). The CDI-21600 error
masks the underlying exception error. To see the real error do the following:
1. Go into the Registry Editor (REGEDIT).
2. Navigate to HKEY_LOCAL_MACHINE\software\oracle\des2_70
3. Set EXCEPT_HANDLING to 0 (by default it is 1).
Repeat the action that resulted in the error.
I have read this article and it seems that there is not such bug, but ... ?
Maybe this will be a little help for you.
Helena -
R 6018 unexpected heap error when generating a form in Designer
When generating a form in Designer i get the following error:
r 6018 unexpected heap error
Has anyone else encountered it before with forms?
Kind Regards
Maurice NiezenYou put the question to wrong forum. If it is regarding to Oracle Forms, then post to Oracle Forms forum. If it is regarding to Oracle Designer, then post to Designer Forum. This is the forum for Oracle Reports.
Thanks,
-Shaun -
Error in generating form with 6i
I have installed designer 6i rel 2 with form developer 6i on NT
4.0.
When in design editor, I want to generate the form with generate
module, the system generate "CDR-21600: A running Generator or
Utility has failed."
Also in action column writes: " It is possible that the internal
cache is now in an inconsistent state. You are therefore
recommended to close and restart the application."
Could anyone tell me what is the problem and how to solve it.
thanksHere is an document which describes some known causes of CDR-
21600 errors. I hope it will help you.
PURPOSE
To describe some known causes of CDI-21600 errors and to
suggest possible solutions and workarounds.
SCOPE & APPLICATION
This note was written for users of Oracle Designer releases 2.1.x
and 6.0.
CDI-21600 errors occur most frequently during Design Capture and
when generating forms with the Forms and WebServer generators.
Investigating CDI-21600 errors
In Oracle Designer Release 2.1.2 and Release 6.0, this error has
the form:
CDI-21600 'A running generator or utility has failed'
The Release 2.1.1 error message was: 'Generator or Utility throw
an Exception'
The CDI-21600 error message means that the generator is hitting
an unhandled exception, also known as a GPF (general protection
fault). The CDI-21600 error masks the underlying exception error.
To see the real error do the following:
1. Go into the Registry Editor (REGEDIT).
2. Navigate to HKEY_LOCAL_MACHINE\software\oracle\des2_70
3. Set EXCEPT_HANDLING to 0 (by default it is 1).
Repeat the action that resulted in the error.
Known Causes of CDI-21600 Errors and Possible Solutions
Some of the reasons why CDI-21600 errors occur are listed below.
1. A common cause of CDI-21600 errors is failure to install the
necessary
Developer patches.
See [NOTE:64630.1] Developer Patches required to run
Designer with Developer
2. Check that Designer is running on a supported database. Also
check that the
TNS connection is correct.
See [NOTE:60705.1] Designer Certification Matrix (HTML)
3. Check for 'dangling' foreign keys, in other words FKs no longer
owned by any
table in the repository. Delete all invalid constraints.
Invalid constraints may be created if you use the repository
dump utility to
dump and restore external foreign keys referencing tables
shared into the
application system, without dumping and restoring the tables
that own them.
If you restore a complete dump (rather than a 'skeleton' one),
and then use
the 'Reconnect Share Links' option when restoring, you may be
able to
resolve this problem.
To get a complete list of 'dangling' constraints in your
repository, connect
using SQL*Plus and use the following query:
SELECT app.name, key.name
FROM ci_application_systems app, ci_constraints key
WHERE key.table_reference IS NULL
AND key.application_system_owned_by = app.id;
You can also run CKAZANAL.ANAL_REFERENCES on your
repository and delete all
the invalid constraints that it finds. You can run the Repository
Analyzer
from: Front Panel -> Repository Administration Utility -> Utilities.
NOTE: There may be inconsistencies in the repository that the
Repository
Analyzer cannot fix. You might solve such problems by
dropping all the
tables of your application, recreate them from the ERD,
then use the
DDT and recreate your modules.
[BUG:847190] CDI-21600 during forms generation: 'dangling'
foreign key
"Since the generator is running on a repository that contains
invalid
constraints and the Repository Analyzer solves the problem,
bug closed as
unfeasible to fix."
4. Check your modules for invalid or missing references such as
missing window
placements.
5. Try generating your module against default templates and
object libraries.
6. When capturing forms or libraries, try capturing the form or
library without
application logic, then capture the application logic on its own.
See [NOTE:1064690.6] CDI-21600 when capturing design of
form with
application logic
[BUG:757541] DESCAP: CDI-21600 error reported when
capturing with
application logic
Fixed In Ver: 6.0
[BUG:926383] Duplicate of [BUG:757541] This has been fixed in
2.1.2 patch
779559. However you would be advised to apply a later patch
such as 855635
which fixes more bugs in this area.
7. Make sure that all objects that are referenced by the form have
been
captured into the repository before capturing the form.
8. A CDI-21600 will occur if a lookup usage displays only one
column of
datatype DATE or if the column of datatype DATE is displayed
as the first
item in the block.
Workaround
Add more column usages to the lookup block and do not
display the DATE data
type column usage as the first item in the block.
9. [BUG:810472] CDI-21600 when 'Argument in Caller' is set
Fixed In Ver: 6.5.3.0
Workaround
Make sure that you have an argument in the called module that
is mapped to
the "Argument Passed Value" in the calling module. The only
way to get this
mapping back once the APV has the <Module Argument> label
is to delete it
and recreate it.
10. [BUG:801736] CDI-21600 on design capture of a form with
subclassed object
Fixed In Ver: 6.0.3.1.0 (backport)
Fixed In Ver: 6.5
You have an item that has been subclassed to an object.
Checking the Design
Capture option 'Capture Control Blocks' causes the CDI-21600
error. Uncheck
'Capture Control Blocks' and the problem does not occur. Open
the FMB in
Forms*Builder and look at Data Blocks -> Items. Break the link
to the
object, save the FMB, and the form will capture (similar to
[BUG:794872]).
Alternatively, ensure the link can be established.
11. [BUG:850436] CDI-21600 on generation of a form with template
having
subclassed object group
You try to generate a form out of Designer that uses a user-
defined
template. If a collection of objects in the template is grouped
into an
object group, dragged into the object library and then either
copied or
subclassed into a form, when the form is generated you get a
CDI-21600
error.
12. [BUG:822659] Module generation fails (CDI-21600) with multi-
column PK having
long prompt text
Fixed In Ver: 6.5.3.2
Module generation with multi-column primary key having long
prompt text
causes CDI-21600 with preference MSGSFT set.
Workaround
Shorten the prompt text of PKs may not be not applicable. You
may loose end
user information.
You may have the same problem with a mandatory compound
FK. CASEOFG tries to
generate a message '<P1> must be entered', where <P1>
contains all the
prompts of the bound items from the FK. If you reduce the
length of the
prompts, or set MSGSFT = NULL or WEDI = S or property
Mandatory?=No, it
works correctly.
13. [BUG:792542] Capturing application logic causes CDI-21600
(V2 style
triggers)
Fixed In Ver: 6.5.5
After removal of the v2 triggers, the form captures/merges OK
on 5.0.24.8,
provided patch 875027 has not been applied.
14. [BUG:790877] CDI-21600 if the primary/foreign keys have no
key components
Fixed In Ver: 6.5.11
Generating a module with tables having a primary key not
correctly defined
(no PK component) will cause a CDI-21600 error. This can
occur when
unloading a module from the RON. If you pick up the module
(and only the
module) in the unload set, the table and its PK are unloaded as
a skeleton.
Loading the .DAT file into a new application will create a PK
without a
component.
15. [BUG:771549] CDI-21600 if cannot connect to the DB with
connect string in
Options (Compile)
Fixed In Ver: 6.5.13
If you cannot connect to the DB with the connect string
specified in options
(Compile), the forms generator will fail with CDI-21600.
This problem occurs when you cannot connect to the DB
because:
- the username or password is wrong;
- or the SQL*Net alias is not defined in the TNSNAMES.ORA
file;
- or the SQL*Net listener is not started;
- or the DB is down.
16. [BUG:785106] CDI-21600 when generate master detail form
with preserve layout
[BUG:855812] is a duplicate of this bug.
Fixed In Ver: 5.0.24.6.0 (Bug:860426 Backport request for 2.1.2)
Fixed In Ver: 6.0
Fixed In Ver: 6.5.3
You have a master-detail Form with the Master having items
partly on a TAB
Canvas. Generate Module works OK. You enter Forms Builder
and move some
items on the tabs (just small changes, items are still on the
same tabs).
You change the look of the Detail and change Records
Displayed. Now in
Designer you generate the Module with Preserve Layout. You
get a CDI-21600
error. The problem might reproduce without doing any changes
in Forms
Builder, just by generating with Preserve Layout.
17. [BUG:891306] If primary key column of lookup in check
constraint comment of
base table
Fixed In Ver: 6.5.5
Workaround
Do not use the name of the bound item that is based on the
primary key
column of the lookup table in a check constraint comment of
the base table.
18. [BUG:896026] Forms gen throws assertion failure in
CVINI/BUILDACTIONITEM@/CV/CVI/CVIBNI.CPP
Fixed In Ver: 6.5.7
A problem is caused by a PL/SQL definition (function, package,
procedure)
being defined as a called module for the module you are trying
to generate.
To resolve the problem and enable the module to be generated,
remove all
Called Modules that are PL/SQL definitions (functions,
procedures or
packages).
See [NOTE:2107207.6] CDI-21600 during generation of module
or Assertion
Failure \cv\cvi\cvibni.cpp
19. [BUG:812333] CDI-21600 generating a web module after
adding an unbound item
Fixed In Ver: 6.5.3.0
Backport [BUG:1280667] raised to fix by 6.0.3.9
You add an unbound item (SQL expression) to a Web module.
When you try to
generate the module you get a CDI-21600 error. If you delete the
unbound
item the Web module generates correctly.
In a test case the problem occurred during validation of the
derivation
text, if the master module component was in a different module.
A workaround
was to rearrange module components so that this was not the
case.
20. [BUG:1627963] CCVDIAG::TRACEGENERATORMESSAGE
WHEN GENERATING INCORRECT
DERIVATION EXPRESSION
Message
CDR-21605: Failed while processing Module <mod> in function
CCVDiag::TraceGeneratorMessage BOF
Cause
The generator failed due to an unexpected error - the
error indicates the object the generator was processing
when it failed.
Helena -
Error Generating the Task Form
While publishing a new SharePoint Designer 2010 List Workflow I get an Error:
SharePoint Designer encountered an error generating the task form. Server was unable to process request.--->Activation could not be completed because the InfoPath Forms Services support feature is not present.
I was able to publish SPD Workflows until a couple of days ago. Existing ones can be republished but not new ones.Try running the following cmdlets.
Disable-SPFeature "IPFSSiteFeatures" - URL "Path"
Enable-SPFeature "IPFSSiteFeatures" -URL "Path"
These cmds will restart the Infopath Forms Services support features, which is responsible for supporting publishing Infopath Forms.
Hope this works for you. -
R 6018 unexpected heap error when generating forms
When generating a form in Designer i get the following error:
r 6018 unexpected heap error
Has anyone else encountered it before with forms?
Kind Regards
Maurice NiezenYou put the question to wrong forum. If it is regarding to Oracle Forms, then post to Oracle Forms forum. If it is regarding to Oracle Designer, then post to Designer Forum. This is the forum for Oracle Reports.
Thanks,
-Shaun -
CDI-23564 error when generating FORM.
Hi,
After installing Designer 6.0 and Patchset 1 (6.0.3.5) ,when generating FORM , system always prompt that it could not load CFG60.DLL. Had check that CFG60.DLL exists in orant/BIN and also in Window registry. Reformatted hard disk, change hard disk, tried on WIN98 and WIN2000, still the same result.
Thanks in advance!!!The error message is misleading.
Install Developer2000 appropiate version.
Designer install only some report and graphics run time file.
It solved me the problem.
Regards,
Otto Bertalan
Otto Bertalan
null
Maybe you are looking for
-
How to hide a window in smartforms
Hi experts, How to hide a window in smartforms depends on the conditions. The condition is the window how a hard coded values + fields. if the condition satisfies i want to display in form if its fails no need to display in the form... plz,
-
Remove leading space(blank) REGUH-RWBTR in script
hi, i am now dealing with cheque priting in word issue. the output format should be : <b>USD 111,000 AND CENT 45 ONLY.</b> the amount field i use is REGUH-RWBTR in script. but the output come with leading of space. <b>which is as : USD 111,00
-
Reply arrow in message status missing
When you reply a message an arrow appears next to the message indicating mail has not only been read, but replied and if you click that arrow you can view your response. This usually works fine, but I wrote an e-mail yesterday responding to one I had
-
OWA - Bulk Import of Contacts into Group
What is an option for importing a list of email addresses into OWA Contact Group/creating OWA Contact Group and pasting members' mail addresses into it? Similarly, if I create a new folder in My Contacts, how I can bulk import into this new folder? W
-
Grey scren after MacBook Pro Update 2.0
I downloaded the last update but my Mac is still With a grey screen 1 hour after the restart... so... what can i do ?