Error importing SFTP Send ports!

Hi all,
While importing a binding i got this error :
Error validating property "Transport Log": Unknown Event Log name : Biztalk Marina
Should i create a special EventLog ? If yes how can i do that ?
Thank's in advance for your help :)

After a bit of googling [https://www.nsoftware.com/kb/tutorials/biztalksftpadapter.aspx] I found the property "Transport Log" associated with the /n Software Inc. SFTP Adapter.
Are you sure that this is the same adapter installed on the source and destination systems? If the destination system has a different SFTP Adapter then even though the protocol in question is SFTP, due to different implementations it would NOT be possible
for you to import the bindings across the two systems.
Regards.

Similar Messages

  • BizTalk 2013 SFTP Adapter Dynamic SFTP send port exception: Open remote file for write error

    I am using BizTalk 2013 SFTP adapter. I defined a Dynamic One-Way
    send port on BizTalk server administration.
    Below is the error I'm getting on BizTalk while trying to write files to a designated folder on a client's SFTP server.
    When defining the same path and properties on a Static One-Way send port everything works properly and the files are being saved on the SFTP server.
    A message sent to adapter "SFTP" on send port "ComverseSFTP_1.0.0.0_ComverseSFTP.SendFileToSFTP_SendFileToSFTPServer_f6b86b86a22079f8" with URI "SFTP://abc.xyz.com:22/upload/%SourceFileName%"
    is suspended.
    Error details: Microsoft.BizTalk.Adapter.SftpInvoker.SftpException: Open remote file for write error.
     Server stack trace:
       at Microsoft.BizTalk.Adapter.SftpInvoker.SftpInvoker.OpenRemoteFileWrite(String fileName, Int32 fileOffset)
       at Microsoft.BizTalk.Adapter.SftpInvoker.SftpFileWriterStream.Write(Byte[] buffer, Int32 offset, Int32 count)
       at Microsoft.BizTalk.Adapter.Sftp.SftpOutputChannel.Send(Message message, TimeSpan timeOut)
       at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
       at System.Runtime.Remoting.Messaging.StackBuilderSink.AsyncProcessMessage(IMessage msg, IMessageSink replySink)
     Exception rethrown at [0]:
       at System.Runtime.AsyncResult.End[TAsyncResult](IAsyncResult result)
       at System.ServiceModel.Channels.ServiceChannel.SendAsyncResult.End(SendAsyncResult result)
       at System.ServiceModel.Channels.ServiceChannel.EndCall(String action, Object[] outs, IAsyncResult result)
     Exception rethrown at [1]:
       at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
       at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
       at System.ServiceModel.Channels.IOutputChannel.EndSend(IAsyncResult result)
       at Microsoft.BizTalk.Adapter.Wcf.Runtime.WcfClient`2.SendCallback(IAsyncResult result)
    MessageId:  {926F44F2-9180-4B33-96FF-9E4CBC459382}
    InstanceID: {36A50A7F-63C4-48D9-903D-A33C85DDAE36}
    Can you please assist with explaining why are we getting this exception?
    Thank you for your help.

    Below is the error I'm getting on BizTalk while trying to write files to a designated folder on a client's SFTP server.
    When defining the same path and properties on a Static One-Way send port everything works properly and the files are being saved on the SFTP server.
    A message sent to adapter "SFTP" on send port "ComverseSFTP_1.0.0.0_ComverseSFTP.SendFileToSFTP_SendFileToSFTPServer_f6b86b86a22079f8" with URI "SFTP://abc.xyz.com:22/upload/%SourceFileName%"
    is suspended.
    Error details: Microsoft.BizTalk.Adapter.SftpInvoker.SftpException: Open remote file for write error.
    Hi Yaeli1,
    From the error message above,  please check the permission for file writing , it seems that this issue is related to access permission.
    Best regards,
    Angie
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • ACK/NACK Handling In Biztalk 2010 Orchestration - SFTP send port

    Hi,
    I am using SFTP adapter and wants to get ACK/NACK in orchestration. I have implemented all the required steps mentioned in the below blog:
    http://blogs.msdn.com/b/kevinsmi/archive/2004/07/03/172574.aspx
    I am getting the ACKs, but in case of failure I do not get any NACK. Does anyone know how to get it ?
    Thanks,
    Iqra 

    SFTP adapter doesn't have any configuration property to get the acknowledgement.
    To get the ack/nack you have to let the BizTalk engine with the property “BTS.AckRequired”
    set to true. With Orchestration this property can be set by enabling Delivery Notification
    to Transmitted.
    The DeliveryFailureNotification is typically only used for one-way send port not for solicit-response port. Following article can guide you on Delivery notification
    in Orchestration.
    http://kentweare.blogspot.co.uk/2007/11/biztalk-delivery-notification.html
    Along with the other obviously settings for delivery notifications in orchestration, also set the
    Send-Port’s retry to zero (0). This setting is most overseen by many.
    If this answers your question please mark it accordingly. If this post is helpful, please vote as helpful by clicking the upward arrow mark next to my reply.

  • Sender Port Invalid.

    Hi Experts,
    We have pre-prod system(MR0) and Production System(MP0). recently our MR0 is refreshed and copy MP0 to MR0.
    Now when i am trying to process any IDOC it is giving me the error like 'EDI: Sender port in control record is invalid'.
    So if i want to change the sender port how can i change it?
    Thanks in Advance,
    Abhishek.

    >
    abhishek ingole wrote:
    > Hi Experts,
    >
    > We have pre-prod system(MR0) and Production System(MP0). recently our MR0 is refreshed and copy MP0 to MR0.
    > Now when i am trying to process any IDOC it is giving me the error like 'EDI: Sender port in control record is invalid'.
    > So if i want to change the sender port how can i change it?
    >
    > Thanks in Advance,
    > Abhishek.
    I think you are trying process a IDoc in system MR0 which was created in system MP0.
    Sender port for outbound Idoc should be SAP<sys-id>, in your case in system MRO it should be SAPMR0 but it is SAPMP0. If this is the case then you can process those Idocs by changing port to SAPMR0 using transaction WE19.
    Edited by: Pawan Kesari on Dec 23, 2009 9:50 PM

  • Dynamic Send Port : The FILE send adapter cannot open file C:\Temp for writing. Details: Access is denied.

    Hi All,
    We have requirement of using ESB toolkit and transforming incoming xml file to edi format. So, we are using ItinerarySelectReceiveXML pipeline for receiving the input from the input location and "EDISend" pipeline for transforming it into EDI and
    send it to destination.
    Now, the receive pipeline is picking up the file, but it is not processed and sent to destination.
    And, we are getting an Access Denied error from Dynamic send port.
    Error Description : 
    The FILE send adapter cannot open file C:\Users\Public\Temp for writing.
     Details: Access is denied.
    Any Immediate solutions/suggestions are appreciated...Thanks.
    Anand

    The difference between dynamic and static port would be send handler. For dynamic port, default send handler will be used and for static port the one configured on the port will be used, could you validate this configuration.
    Also sometimes, administrative privileges are not "real" administrative privileges and company admins will have limited permissions on C Drive folders. Try writing to some other folder to isolate the issue.
    Regards, Ajeet Kumar MCTS Biztalk Server

  • Error when using 64-bit host in send port

    Guys,
    I am trying out a simple message routing scenario. I have created a send pipeline and have used the MIME/SMIME component in the encoding stage of the pipeline. My application has a receive and a send port with receive port configured to receive *.xml documents
    and is using XMLReceive pipeline. My send port uses the pipeline I have explained above and contains a filter to BTS.ReceivePortName=="[receive port in the application]". The send port is also configured to use a certificate. The send handler is the 64-bit
    BizTalk host. When I drop a message in the receive port, message in the send port gets suspended with error "Retrieving the COM class factory for component with CLSID {254B4003-2AA7-4C82-BB2E-18BA7F22DCD2} failed due to the following error: 80040154
    Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)).
    " However when I use a 32-bit host message on the send port gets encrypted as I expect. Has anyone faced this issue before and found a solution? BTW I am using BTS 2010 on 64-bit machine

    http://msdn.microsoft.com/en-us/library/aa559177(BTS.10).aspx
    This occurs because the MIME pipeline component is not supported in a 64-bit host instance. To resolve this, the host associated with the send and receive handler for the file adapter must be configured as a 32-bit only host. For more information on this
    see How to Modify Host Properties. If you already have a 32-bit only host configured on the system and want to use it see Configuring the File Adapter for instructions on configuring the host(s) associated to the file adapter’s send and receive handler.
    The following is signature, not part of post
    Please mark the post answered your question as the answer, and mark other helpful posts as helpful, so they will appear differently to other users who are visiting your thread for the same problem.
    Visual C++ MVP

  • Sender Port Error in SAP ECC for IDoc

    Hi,
    I am creating scenario IDOC -> XI -> JDBC with Customer Master IDoc.
    After sending it with we19 he said "IDoc sent to SAP system or external program".
    In we02 and we05 the IDOC it says "Data passed to port OK".
    But in SM58, the IDoc ends in error saying
    Transaction IDX1: Port SAPIDST100, client 600, RFC destination contains error.
    What I identified that the port SAPIDST100 is the sender port in the IDoc being send. However, for PI we do not need to maintain sender port.
    Business Systems:
    Sender : SAP ECC
    Receiver: SAPPID
    Kindly provide your inputs.
    Thanks
    Rahul

    Hi Rahul,
    thanks for the information that your scenario is working fine.
    But i want to clarify some points:
       - If you send out an IDoc from an ECC system, the senderport is filled with SAP+<system-id> by the SAP IDOC API,
         i.e.  if your system id is "ABC", the senderport is "SAPABC"
          => your senderport SAPIDST does not match this template, so i assume you entered the value for the senderport
         manually in the idoc test utility WE19
       - if you send out an idoc, only the receiver port must be created in transaction WE21, it is not necessary to create
         the senderport in WE21, this is not necessary and did not solve your problem
      - the idoc was send from ECC (application system with application IDoc metadata) to an XI/PI system (basis system      
        without application idoc metadata
       The IDoc adapter on the pi system must analyze the IDoc segments and must know the idoc application metadata,
       but this is not known. So the idoc adapter on PI side looks at the senderport to identify the sender.
       In transaction IDX1 an rfc-destination can be configured to point to the sendersystem with that senderport
       With this rfc-destination  the IDoc adapter tries to read the idoc aplication metadata from the ECC system and stores it on PI side.
       If there is no rfc-destination configured in transaction IDX1 on PI side you get the error mentioned in your request.
       I assume that in transaction IDX1 somebody configured the correct RFC-Destination.
    I hope this clarification helps you to understand the error and the solution.
    Kind regards,
    Andreas Dahl

  • Outbound IDoc Error: Status Code 37  'Sender Port' is invalid

    Hi
    I have an Error when the Outbound IDoc is triggered.
    It shows that 'Sender Port in Control Record is invalid'.
    Status Code: 37.
    I know that there are some issues with the Sender Port Definition.
    Please help me out to solve this problem using some checkpoints at each and every step.
    Reward Points Assured.
    Regards,
    Baburaj

    Hi Baburaj Manickam
    Good
    Follow this simple procedure
    1) Send an outbound IDOC data(MATMAS) to a flat file on client1(SENDER).
    -  Create File Port (WE21) for outbound file.
    -  Maintain Distribution Model (BD64) for sender ->receiver system.
    -  Create Partner Profile (WE20) for logical system.
    -  You can use this program RBDSEMAT (t/code BD10) to generate IDoc MATMAS file(s). 
    _  Then you can FTP the file(s) to receiver system.
    2) Upload the flat file as an IDOC on the inbound sytem
    which is Client2(RECIEVER).
    -  Create File Port (WE21) for inbound file.
    -  Maintain Distribution Model (BD64) for receiver -> sender system.
    -  Create Partner Profile (WE20) for logical system.
    -  You can use this program RSEINB00 to upload IDoc MATMAS file(s). 
    INBOUND IDOC PROCESSING:
    Firstly attach your idoc to a process code.
    In the process cod you can tell the system that the specified program should be triggered whenever an idoc of that type comes to the system.
    Then you want to have a Z-function module for your idoc processing, if I understand correctly.The steps should be:
    1. Create a z function module for idoc inbound posting (copy from a function module idoc_input_*).
    2. Set Function Modules as Inbound: - Transaction BD51
    3. Assign Function Modules to Logical Messages and Idoc types:- Transaction WE57
    4. Create process codes : Transaction WE42, and link the z-function module.
    5. Create partner profile: transaction WE20 and attach the message type and process code.
    6. In the Z- function module, extract data from the idoc segments, do whatever processing you want to do, and then call BAPI_CREATE_SALES_ORDER_FROMDAT2.
    Try the Trasaction WE19 for testing your inbound and outbound IDOCs
    Good Luck and Reward me for the same
    Thanks
    Ashok.N

  • Error in send port executed procedure in Biztalk and SQL Server

    Hi,
    I have a send port which call the below stored procedure
    USE
    GO
    SET
    ANSI_NULLS
    ON
    GO
    SET
    QUOTED_IDENTIFIER
    ON
    GO
    ALTER
    @ProcessId
    VARCHAR
    (100),
    @FilePath
    we are revieving the Error as below and the send port is getting suspended
    System.Data.SqlClient.SqlException: Transaction count after EXECUTE indicates a mismatching number of BEGIN and COMMIT statements. Previous count = 1, current count = 2.
    can anyone just help me with this?

    Begin TRANSACTION
    END TRY
    BEGIN CATCH
    BEGIN
    ROLLBACK TRANSACTION ;
    END
    Exactly, you have a BEGIN TRANSACTION and a ROLLBACK in error case, but no COMMIT at all.
    Olaf Helper
    [ Blog] [ Xing] [ MVP]

  • MSDTC Error on Send Port

    Running BizTalk Server 2010, we've two identical Send Ports in two different BizTalk applications, both calling same stored procedure with same properties but one works and the other fails with the following error.
    An error occurred while processing the message, refer to the details section for more information Message ID: {B44DCA75-BC09-40AA-99A3-09A6A9BC5CBB} Instance ID: {1074A172-0ADB-4045-A27D-EE6FC94D285A}
    Error Description: System.Transactions.TransactionManagerCommunicationException: Communication with the underlying transaction manager has failed. ---> System.Runtime.InteropServices.COMException: The MSDTC transaction manager was unable to push the transaction
    to the destination transaction manager due to communication problems. Possible causes are: a firewall is present and it doesn't have an exception for the MSDTC process, the two machines cannot find each other by their NetBIOS names, or the support for network
    transactions is not enabled for one of the two transaction managers. (Exception from HRESULT: 0x8004D02A) at System.Transactions.Oletx.ITransactionShim.Export(UInt32 whereaboutsSize, Byte[] whereabouts, Int32& cookieIndex, UInt32& cookieSize, CoTaskMemHandle&
    cookieBuffer) at System.Transactions.TransactionInterop.GetExportCookie(Transaction transaction, Byte[] whereabouts) --- End of inner exception stack trace --- Server stack trace: at System.Runtime.AsyncResult.End[TAsyncResult](IAsyncResult result) at System.ServiceModel.Channels.ServiceChannel.SendAsyncResult.End(SendAsyncResult
    result) at System.ServiceModel.Channels.ServiceChannel.EndCall(String action, Object[] outs, IAsyncResult result) at System.ServiceModel.Channels.ServiceChannel.EndRequest(IAsyncResult result) Exception rethrown at [0]: at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage
    reqMsg, IMessage retMsg) at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type) at System.ServiceModel.Channels.IRequestChannel.EndRequest(IAsyncResult result) at Microsoft.BizTalk.Adapter.Wcf.Runtime.WcfClient`2.RequestCallback(IAsyncResult
    result)
    If it's a problem with the MS DTC or the stored procedure permissions, it should not work for both of these but it is working for one of them, which means the access and permissions
    are fine, really bowled over this, any idea, what could be wrong?
    Thanks
    Syed

    Hi Syed,
    Your problem lies with  firewall blocking your SQL outbound call .You need to Open the Ports to do the communication 
    Error ":Possible causes are: a firewall is present and it doesn't have an exception for the MSDTC process, the two machines cannot
    find each other by their NetBIOS names, or the support for network transactions is not enabled for one of the two transaction managers."
    Thanks
    Abhisek

  • Mac book pro (2008)will not start up,command-v gives (error) Import:Importer start failed for 89(kr:268435459)invalid destination port)

    will not start up.
    tried Command-v
    message reads
    (error) Import:Importer start failed for 89 (kr:268435459)invalid destination port)

    First, uninstall "SuperTV" (whatever that is) according to the developer's instructions. It isn't working and it's filling the log with noise.
    If you have more than one user account, these instructions must be carried out as an administrator.
    Launch the Console application.
    Step 1
    Make sure the title of the Console window is All Messages. If it isn't, select All Messages from the SYSTEM LOG QUERIES menu on the left.
    Enter "BOOT_TIME" (without the quotes) in the search box. Note the timestamps of those log messages, which refer to the times when the system was booted. Now clear the search box and scroll back in the log to the last boot time when you had the problem. Post the messages logged before the boot, while the system was unresponsive or was failing to shut down. Please include the BOOT_TIME message at the end of the log extract.
    Post the log text, please, not a screenshot. If there are runs of repeated messages, post only one example of each. Don’t post many repetitions of the same message. When posting a log extract, be selective. In most cases, a few dozen lines are more than enough.
    PLEASE DO NOT INDISCRIMINATELY DUMP THOUSANDS OF LINES FROM THE LOG INTO A MESSAGE. If you do that, I will not respond.
    Important: Some private information, such as your name, may appear in the log. Edit it out by search-and-replace in a text editor before posting.
    Step 2
    Still in Console, look under System Diagnostic Reports for crash or panic logs, and post the most recent one, if any. In the interest of privacy, I suggest you edit out the “Anonymous UUID,” a long string of letters, numbers, and dashes in the header of the report, if present (it may not be.) Please don’t post shutdownStall, spin, or hang logs — they're very long and not helpful.

  • BizTalk Send Port Error

    We are getting error on send port after some changes in the map, but there is no change in the map which is throwing error -
    Event Type: Error
    Event Source: BizTalk Server 2009
    Event Category: (1)
    Event ID: 5754
    Date:  11/26/2013
    Time:  1:14:22 PM
    User:  N/A
    Computer: XXXX
    Description:
    A message sent to adapter "WCF-Custom" on send port "SndABCD" with URI "mssql://ABCDSQLDB/INSTANCE/ABCDReport?" is suspended.
     Error details: The system cannot find the file specified. (Exception from HRESULT: 0x80070002)
     MessageId:  {A79F62AD-3C63-4543-9FEF-2682CF83106A}
     InstanceID: {941EBEF7-7008-451C-AEBE-C7407462F943}
    For more information, see Help and Support Center at
    http://go.microsoft.com/fwlink/events.asp.

    I have checked below links already which suggest, gac the DLL, but did not work for me -->
    http://social.msdn.microsoft.com/Forums/en-US/01791899-a0bf-451d-9004-fe8b696a9270/custom-functoid-the-system-cannot-find-the-file-specified?forum=biztalkediandas2
    http://blogs.eliasen.dk/Technical/post/2010/01/17/TheSystemCannotFindTheFileSpecified.aspx
    http://stevestechnotes.blogspot.com/2008_02_01_archive.html

  • Error on Send Port configured using HTTP adapter

    Hi All,
    For Load balancing purpose we have created new host and host instance and changed send handler for send port configured using 
    plain HTTP adapter.
    We are getting below error after change:
    A password is mandatory if UserName is specified
    Parameter name: Password
    Please advice.
    Thanks
    Pooja Jagtap Software Engineer KPIT Cummins

    Have you updated the password for your Host instance . Try restarting your host instance once .
    Thanks
    Abhishek

  • Getting error - A message going to a one-way send port is being suspended.

    Hi,
    I am getting the following error message (in the BizTalk administration console), on my Production servers, upon testing one of my BizTalk Interfaces, deployed on the same :-
    A message going to a one-way send port is being suspended. Reason: The send port configuration corresponding to the message was not found.
    This usually happens when a send port was deleted while it still had some active messages.
    The same application is working fine on the Test environment.
    Please note
    à This is a clustered BizTalk environment.
    I have checked, both the Host Instances are running properly, on the same environment.
    I am also able to connect to the SQL database (Msgbox) server, that the BizTalk servers are pointing to.
    Can you kindly guide on the same.

    Hi Shalini,
    This very well could be an SSO issue.  Are you getting any SSO errors in the event log?  Intermittent SSO issues could cause the
    inconsistent results you are seeing.   
    Of course, as the port configuration is stored in the SSODB, if access to this database is restricted port configuration cannot be accessed
    and so the message could not be delivered.
    Refer: http://blog.sabratech.co.uk/2007/02/send-port-configuration-corresponding.html
    Also, try changing the send handler to run under different host instance.
    Rachit
    Please mark as answer or vote as helpful if my reply does

  • No Service for System SAPECC(Sender Port), Client800(R/3 system client 800)

    Hi friends,
    I am new to XI/PI I am working with IDOC to Flat file scenario I am facing the folllowing error.
    No Service for System SAPECC(Sender Port), Client800(R/3 system client 800) in integration Directory.
    can any one tell what was the reason for this error.
    Thanks in Advance,
    Ravi Yasoda.

    Hi Ravi,
    Have you imported the Business System in Integration Directory?
    Check whether  you see the logical system name in adapter specific identifiers or not...
    Also check from integration directory that cache notification was done and also check SXI_CACHE in the abap stack.
    See this thread...
    No service for system SAP***, client 001 in Integration Directory
    Please go through below content from sap note  for your issue...
    Error message: No service for system SAPABC client 123 in the integration directory
    Solution:
    You send IDocs from system ABC to XI. In the control record of the IDoc,the SNDPOR field contains the value "SAPABC". The client of the sending system is determined by the MANDT field of the control record. The system ID and client are then used to determine a service without party of the
    type (business-system/business-service):
    Business system
    -> Activities in the System Landscape Directory (SLD)(Create technical
    system):
    Create a technical system for system ABC in the SLD, and create the client for this. Do not forget to assign an "ALE logical system" (for example, "ABCCLNT123") to this technical system.
    SLD (Business system):
    You can now explicitly assign a business system to this client. For more details, refer to the SLD documentation.
    Activities in system ABC (self-registration in the SLD):
    Alternatively, you can register the system in the SLD in system ABC with Transaction RZ70. You will find detailed information about the SLD registration of systems on the SAP Service Marketplace for the
    "Exchange Infrastructure" in the document "Exchange_Installation_Guide.pdf".
    In system ABC, you can check your configuration with Transaction SLDCHECK.
    Activities in Integration Directory (import business system from SLD):
    You will find the business systems under Services Without Party in the Integration Services. In the Service menu, you will find the system identifiers, the client, and the corresponding ALE logical
    system under "Objects"->"Adapter-specific identifiers". Use the Import/Update button to copy the data from the SLD, to create business systems, or to update their identifiers.
    Business service
    -> Activities in the Integration Builder directory:
    You want to create a service without party that is not part of your system infrastructure and is therefore not maintained in the SLD. In the Integration Builder directory, you will find the "Business-Services" under Services Without Party. In the Service menu, you will find the system identifiers, the client, and the corresponding ALE logical system under "Objects"->"Adapter-specific
    identifiers".
    Activate the change list in Integration Directory.
    In system ABC, you can restart the incorrect entry from Transaction SM58 .
    Regds,
    Pinangshuk.

Maybe you are looking for