Error in activating Info source
Hi All;
It gives me warning log, but where to see it.
View the log for the function 'Show log for the node' in the Administrator Workbench.
Thanks,
Manasa.
Hai Manasa....
please to see the Step By Step BW Guide....
It will Clarifies all your Pratical Doubt in BW...
BalajeeKannan
Similar Messages
-
Error while activating info sourcce
hi all,
I am trying to load flat file data to Bw.
I assigned data source for my info source, and when i am activating info source ,it is giving the folowing error.
" Table /BIC/B0002019000 must be created in the database ".
Can any one help me out on this please.
karunakar redyHi,
The table you are refering is the Transfer Structure table. Do the following:
When you are doing a flat file load you need to add all the info-objects in the Communication structure and click the "Transfer" button in the Comm Structure. Now all the info-objects would be available in the transfer structure. Now click on the "Propose Transfer Rule" button in the Transfer rules area. Now activate the Info-source. Hopefully everything would be fine.
Bye
Dinesh -
Error while activating Data source
Hi,
I hit an error while activating data source with adapter 'WEB_PUSH web service'.
The error message is 'Generation of conversion exists and PSA update ...' with details 'Error generating Web service /BIC/CZZZ_0010000100 ...' and 'Error when activating DataSource ZZZ_001'.
I can't find much detail on this error.
Has anyone hit this error before and if you did can you please let me know what to check?
Thks & Regards,
BbeeHi,
I am having the same problem. Have you been able to solve the issue since you posted this last year?
Thanks,
TCT -
Error while activating data source in BI
Hello Team
I am facing issues while activating data source. I followed following steps .
a)First i created my target
b)Then i made my Primary key as info provider
c)Then i created one source system under file.
d)Then i went to data source and created one application component
e)In this application component i created my data source
f)In this data source i imported my file and all the settings. Now when i am checking then it is not giving any error . But when i am trying to activate it it is giving error . Please find the supporting screesnhots . Can anyone please suggest me as to what is going wrong .Hi,
Check the gateway settings for
Gateway Host
Gateway service
Also check the UDC connection information.
Check these links:
1 - http://help.sap.com/saphelp_nw04/helpdata/en/78/ef1441a509064abee6ffd6f38278fd/content.htm
2 - http://help.sap.com/saphelp_srm40/helpdata/es/54/ddfb3ff778ed28e10000000a1550b0/content.htm
3 - https://encrypted.google.com/url?sa=t&source=web&cd=7&ved=0CCwQFjAG&url=http%3A%2F%2Fwww.bi-
expertonline.com%2Fdownloads%2FSchroeder0604.doc&rct=j&q=ud%20connection%20in%20sap%20bi&ei=WMDnTdm_E4ruvQOEzZWcDg&usg=AFQjCNGvqKuoTq9kypNMNGhis8WrZ-gFCg&cad=rja
Let us know in case the issue still persists.
Debanshu -
Error in activating data source
Hi Gurus,
I'm facing error when generating data source stating "THE OLTP SOURCE STILL HAS ERRORS"
when i activate my structure in "se11" it is activating .
could you tell me how to get rid of this error............
Regards,
Vijay.HI Siva,
I faced this problem with refernce fields...........
I've given wrong refernce so this was encountered......
Check u'r refenc fields..................
regards,
Vijay. -
Error when acivating Info Source
Hi
I get an error when I try to activate an info source 0TRANSTYPE. It activates fine on BW dev. Transports fine to BW QA, but gives an error on BW prod.
The error it gives me is :
u2022 Error when creating transfer structure /BIC/CCLC0TRANSTYPE_ATTR in source system 90
I did try to reactivate the DataSource on the source system.
I also replicated the DataSource in the BW system and ran RS_transtru_activate_all after the transport to our BW Production system. But no luck.
The thing is, it works fine on the Development and QA servers.
Do you have any suggestions on what else I can do?
Much appreciated.Hi Arun
Thanks for getting back to me.
1) Both the QA and Prod system changeability is the same( This is the only infosource that I get this message with).
2) I also did a replicate an the source is visible for that source.
3) the error I get is R1304 - Error when creating transfer structure /BIC/CCLC0TRANSTYPE_ATTR in source system 90
Regards
Mervyn -
Error while activating info objects.
Hi,
After activating the data in ECC rsa5 and replicating it in BW rsa1, when i am trying to activate the infoobjects in object types i get the following error.
*DataSource 0RF_ARTHIER_ACT does not exist in source system DVMCLNT110 of version A *
kindly help me.
thanks.
- rohit mulayHi Rohit,
you can activate the datasource by using 'RSDS_DATASOURCE_ACTIVATE_ALL'program
Please follow bellow steps:
1.Goto SE38>give the Program>click on Execute.
2. Give the technical name of Datasource and Execute.
Note: there is one check box, first execute with that checkbox checked and see, if that didnt work, uncheck the checkbox and execute, hope this should solve your problem.
3. Replicate the Datasouce in BI side.
4. Activate the relavent Objects indevedulally.
Regareds,
Suman -
ERROR IN ACTIVATING INFO OBJECT
GETTING AN ERROR WHEN I TRIED ACTIVATING THE INFOOBJECT. ERROR I GOT IS,
" ERROR GENERATING MASTER DATA ROUTINES."This is an ABAP report which can be used to check the consistency of the Objects related to SID values, Nav attribute, Object versions, values check for MD attributes,,,etc...
In case of any errors, you can see the detailed log here and repair as well...
Pls use this to identify the errors in your IOBJ and correct accordingly!
Hope this helps.
-VA -
Error while activating info package.
Dear all,
While creating and activating the infopackage, system throws the message"Table /BIC/B0001524000 is too long (>004030)"
What could be cause for this error.How to analyse and correct the error.
Your experts solution would be highly appreciated.
Regards,
M.MIf your infosource is too long containing too many infoobjects or lengthy infoobjects you will get this error. To correct this you have to reduce the length of infoobjects used in the infosource or remove unwanted infoobjects in the infosource.
Then this error will not appear.This is a SAP standard restriction -
Error when activating Real Time Data Source
Hi..
I created a generic datasource in R/3 system via RSO2, with the Real-time check box enabled in the settings for Generic Delta. I saved the datasource. Replicated it into BW System.
I tried to activate this Real time Data Source in BW, it says "Error when activating Data Source".
I am on BI 7.0, with PI_BASIS: 2005_1_700.
Please let me know if you need any further information.
Thanks,
Sai.Hi sai,
Can you specify from where you have created your geneic data source like by using DB tabl/view/infoset query.
am -
Error when activating Datasource in Source System
Dear All,
I am gettting this error when activating data source in source system(RSA5).
1)DataSource 0NETWORK_CUST_ATTR; switch to package PS_IS_EHP3_SFWS_SC is off.
2) The extract structure DTTV_REC_53 of the DataSource 0TV_REC_531 is invalid
Message no. R8444
Diagnosis
An invalid extract structure has been assigned to the DataSource. An extract structure has to be active in the DDIC. It cannot be a view, since the customer is not able to add append fields for filling in the customer exits to a view.Hi
To use this datasource, you need to install EHP3 package.
http://help.sap.com/saphelp_nw70/helpdata/EN/b0/7b6c759c494ffcbf821d2442687888/frameset.htm
Chandu. -
Error While activating 0Material(BI7)
Dear Gurus,
I am trying to Activate 0Material Infoobject after deleting a Navigation attribute(Classification characteristics) ,the system throws a error " Error while activating Type Info object".And when i navigated to the Detailed error message it says " error : Internal Activation(info object) - error while converting master data tables .Can anyone help me out with this.
manythanks
arunDear gurus,
We posted the error message to SAP and they have replied " while we deleted the attributes from the Info object(0material) it broke the D-Version of the Object and so to Transport the Info object from another Working system to the Problem(Dev)system ,Install and then activate".
1). Does it mean we can install them object in PRODUCTION Server and then transport to the Development.???
2). Now i tried installing 0Material in RSORBCT in Produciton,but gets a message "Cant make any changes in the repository-changes in this client prohibited". Guys could u help us with this??
manythanks
arun -
Info Source 80FIGL_O06 is not defined in source system
Hi BW Experts,
When I am trying load data from ODS to Cube, I am getting a error messgae stating:
Info Source 80FIGL_O06 is not defined in source system
Error in Source system
This is an urgent issue. Please let me know if you have any suggestions...
Regards,
Reddy.You can do this 2 ways. Right click on the ODS and say generate export datasource. The datasource will start with 8... and you can find that under Datamarts in RSA1-> Infosource. You can then create an infopackage and load from ODS through the update rules. You have the option of full load or delta load.
The other way you can go about this is again right click on the ODS and say update to data targets and just follow from there.
Did you follow the above steps? Where exactly is your problem? -
Error while activating the data source.
Dear all,
We are using the BI version 7.00 - i have a problem i.e., while creating the infopackage for the data source
0PM_OM_OPA_2 the following error is displayed.
"No active transfer rule for DS 0PM_OM_OPA_2 and ....source system CLNTDEV400; create first..."
Moreover the data source is found to be in version "M" - while activating the same when in click on the display/change icon , the following error is popped up.
"You can only edit 3.x DataSources using transfer rule
maintenance Do you want to create the transfer rules now?"
What could be the reason for this error. What are the things that are to be done to replicate the data and pull data?
Valid experts comment is expected in this regard.
Regards,
M.MHi Magesh,
Replicate your data source in BW and then right click onit and choose Assign Info source, it may take you to BC wherein you may need to install the Transfer Rules and related info objects etc.... Once you maintain this data source in the source system then you can create an info pack withput any extra effort.
Hope it helps.. -
While creating Update rules -"Error Info source does not exist"
While creating an update rule I am getting an error that Info source doesnot exist though the inf source is active.
here is error:
No communication structure exists in version abc... A
Message no. RSAU251
Diagnosis
In order to be able to maintain the update rules an active communication structure must be available.
Procedure
This error message can have two causes.
No active communication structure exists.
Activate the communication structure in the Data Warehousing Workbench.
No communication structure exists for the InfoSource.
Create a communication structure in the Data Warehousing Workbench for the InfoSource.
<<text removed>>
Thanks,
Vasu
Edited by: Matt on Apr 26, 2010 9:31 AMHi Vasu,
as it clearly shows below message
No communication structure exists for the InfoSource.
Create a communication structure in the Data Warehousing Workbench for the InfoSource.
Create an info source first and assign it to your datasource and map the fileds in transfer rules and activate it.
Then try to create the update rules between your target and info source.
Hope this helps.
Regards,
Reddy
Maybe you are looking for
-
Iphoto 11 installation can't find some of my pics; can't get past errors without crashing
Back in 2009 when I got my Mac I made a big mistake: I had iPhoto reference my external hard drive for some of my older photos (was trying to save space at the time). I had all new photos going directly to iPhoto (the correct, recommended way). In 20
-
Clicking on the Back button in web browser does not take you back properly
When using Info View and drilling down through reports (using the InfoView Portal in the "View my documents" settings of User Preferences), if you have drilled down through several reports and then want to go back to the page you were viewing before
-
Change Header Banner with transitions within Dreamweaver CS4
Is it possible to have a looping banner with several graphics and transitions within Dreamweaver
-
Open file limit in limits.conf not being enforced
So I am running a Arch installation without a graphical UI and Im running elasticsearch on it as its own user (elasticsearch). Since elasticsearch needs to be able to handle more than the 4066 files that seems to the be the default, I edit /etc/secur
-
Switching Phone Providers Back.
Hi, My Dad is 86 and Verizon was provideing the phone in his home. However, he somehow got switched over to a service called Full Service Network, that is now apparenlty providing his service on the Verizon lines. I'm sure that it was something that