Error in Creating Source System

Hi,
I have a freshly installed BW System here .... I noticed when I tried to create a new source system .... There is a message " No entry for BW_USER in the RSADMIN available"
Please assist
Thx

Hi SNK,
where are you getting this message??
when adding the user to RSDADMINA?
or when creating it in SU01 ?
or when creating the connection with the source system?
try creating ALEREMOTE as a dialog user. this is possible.
and you must have administrator rights (sap_all, SAP_new or similar) in the source system for BW to be able to create the necessary connections.
so as a recap;
1st create the user in Su01
add the user in RSDAMINA
create the source system, and logon to the R/ when asker as an administrator (i am not sure if you also have to log on in client 000)
good luck

Similar Messages

  • Error while creating SOURCE SYSTEM

    Hi All,
    I have a problem while creating Source System to a Solman syatem configured with BW content. I have configured few some source systems already in the same Solman System.The system shows the following error, previous to this i get the message a "generating connection to the source system"
    <b>Error in source system RXX_100
    Message no. RSAR502
    Diagnosis
    With Remote Function Call to system RXX_100 error Screen output without connection to user.  ccurred.
    Procedure
    Remove the cause of the error.</b>
    Kindly provide me suggestions and DOCS related to the same.
    Suitable points will be awarded for replies.
    Expecting your kind reply,
    Vineeth

    Hi ,
    In SCC4 the source client should not set as production when creating the source system connection between two systems.Please check below SAP note
    973555 - System must be open for creating/connecting source systems
    Thanks,
    Shanaka

  • Error while creating source system entry in SAP BW system

    Hi,
    I am creating source system entry in SAP BW system for ECC system.In T-Code RSA1 i entered all the details of source system and BW system like RFC destination of source system and RFC user passowrd.
    After clicking on enter system is promting me to enter into the souce system using administrator user.but i don't have admin user with SAP_ALL and SAP_NEW profiles because in my organisation they don't assign these profiles to any user.
    So can you please update me what are the authorization required for dialog user in source system.
    Regards,
    Gaurav

    I would recommend to create a USER ID as COMMUNICATION type and assign SAP_ALL for it... this way, it can never be misused..
    This will ensure that the user ID will have correct authorization in the source system and will not face any authorization related errors later on

  • Error while creating source system in BI: Modification not possible

    Hi All,
    We are about to move to production, and therefore it's necessary to create in BI the source system related to our ECC (R/3). While trying to perform this action from BI side we received the error message:
    SAP system has status 'not modifiable'. Because of this, and following with known consultants practices we've changed the client to customazing but it still not working although the message at this time is: Changes to repository or cross-client Customazing are not permitted. We have also verified transaction SE06 but it's not possible to change the Cross-Application Component to Modifiable. 
    Did someone face with this same problem before?
    Thanks to all in advance,
    Regards,
    José.-

    Hi Rick,
    I really appreciate your quick response. We followed your recommendation and could create the source system without problems. Thanks once again!
    Best Regards,
    José.-

  • Error when creating source system

    Hi,
    Could someone help me to solve this issue :When I want to create a source system D99100  in BI , I get the following message:
    the test and remore connection via sm59 in BI are OK.
    Source system cannot use any of the proposed connection names
    Message no. RSAR362
    Diagnosis
    Every connection to a source system is named using a unique two-digit identifier. Source system D99100 does not accept any of the proposed values.
    The last proposed value was B9.
    System Response
    Source system has not been connected.
    Procedure
    If you want to recreate the source system from BI information, then you can only use a single value, namely B9, because the connection already has this name in BI.
    Delete the existing connections in the source system or contact a BI consultant.

    Hello,
    By this time your issue might be resolved.
    When you are trying to Connect or Reactivate source systems you might get this error. In the source system (R/3) check the table entries RSBASIDOC. Some reason after system copy, these entries should correct if you run BDLS and some time it mess up.
    Go the table and go to the edit mode and change the entrie for that RFC destination. Change the filed TSPREFIX to some thing else and save it. Go back to BW and try to reconnect and you will be able to connect it.
    Hope this helps in the future for this thread.
    PREDDY.

  • Error msg RSAR502,while creating source system?

    Hello Gurus,
    when i am creating source system i got error msg called RSAR502,can any one solve this issue..
    Thanks in Advance

    Hi,
    Check the OSS note : 184586,493422.
    Take the help of ur Basis support.
    Hope it helps-
    MM

  • Create Source System - Error

    Hi Gurus,
    I have to create a conexion with R3 so i did :
    1)Create RFC Conexion in SM59
    2)Create Source System in RSA1
    But in the last step of the creation Source System in RSA1 shows up the following Error Message:
    "The source system already exists"
    So i checked in the source system list, and it does not exists.
    Can anyone help me about this?
    THANKS A LOT !!!

    Hmm.. not very good over here.. but can you dubleclick and see if they are leading to different clients or not?
    I think they are 2 different clients of the R3's .. so this should be posible..
    Did you created a new logical system and new RFC destinations for this new one?
    May be that it is pointing out to the existing destination..
    regards,
    Hari

  • Error creating source systems

    Hi,
    We have R/3 4.6C and BI7.0 in our landscape.
    When i tried to create source system in BI to R.3 4.6C, its not able to create.
    It giving error "RFC user logon failed". But all the RFC users password is correct and i have tested it.
    I have created successfully with the same RFC user between BI and SRM.
    Can anyone tell me what the problem could be and guide be in this regard.
    Thanks and Regards,
    Sailesh K

    Problem solved.
    R/3 4.6C was sending the password in upper case, despite entering it in lower case.
    Solution: changed the ALEREMOTE password in BI to be uppercase.
    "Message "Name or password is incorrect (repeat logon)" appears when trying to log on to an SAP system, even when the password is known to be correct.       You are trying to log on to an ERP2005 or higher using a set of SAPGui controls that cannot handle case-sensitive passwords. The SAPGui controls are converting the password you type to upper-case, even when the password is lower-case.       
    Change the user password to upper-case (from the initial SAPGui screen or from transaction SU01)."
    Thanks anyway.

  • How can i create source system in BI

    Hi gurus,
      I am using BI 7.0, its SRM addon.
    in that i used source sytem sub functional for creating flatfile.
    there i got folder like BI, SAP, EXTERNAL SYSTEM, FILE, DB CONNECT, UD CONNECT, WEBSERVICE.
    so i trying to create PC souce sytem by right click on FILE folder,
    it popups window with
    Logical system nae---i have given current client
    type and release---What is that?? which one i have to select...it shows as ORA, TLF, XPD.
    I dont know for flat file source sytem why they are asking the above stuff, even we select ORA it shows error as <b>"source system has same name as BI"</b>
    pls hep me out on creation of the source system'
    pls reply as early as possible
    <b>if anyone unable to understand pls tell me</b>
    Thanks in Advance

    Hi Dae,
    Thanks for reply, i will give points tp you, before that let me know the below one.
    I am trying to load master data then Transaction data to cube from flat file.
    For that I have created infoObjects, insource with those objects, and infocube.
    now how can i give the connections in between them like as 3.X, let me know with steps for loading Master and transaction data to Cube.
    Thanks in advance

  • Creating source system in BW3.5

    Hi all,
             I create a source system connection using automatic method and fill up all entry in create source system window in next screen  i give user name and password then these errors are shows
    <b>Changes to Repository or cross-client Customizing are not permitted Choose 'Display object' or 'Cancel'</b>.
    when i am going in help of that error it shows this information  In this logon client any changes to repository and to crossclient customizing objects are prohibited
    can anybody tell me why these errors are occur.
    thx.

    Hi Ankit,
    As you posted yourself this message is appearing because your system is locked for any kind of editing. You need to open it to create this source system. This is generally done by a BASIS consultant.
    You can go to SCC4 as mentioned above by Pankaj and open the client to create this.
    Regards,
    Sumit

  • Create source system in bw

    hi all,
             i am working on bw 7.0 its totally different from bw 3.5 in bw 7.0 i create
             info area , info object , and info cube when i am moving next step create source system ,info source , and assigning data source its totally different from bw 3.5 how can i create these three  can any body send any document or any link or any pdf files realated to bw 7.0.
    mail id : [email protected]
    thanks.

    Hi Ankit,
    To Load Master data
    Creation Of DataSource.
    • In the left panel select DataSource
    • Create application component (AC)
    • Right click AC and create DataSource
    • Specify data source name, source system, and data type (master data attributes / text / hierarchies)
    • In general tab give short, medium, and long description.
    • In extraction tab specify file path, header rows to be ignored, data format  (csv) and data separator( , )
    • In proposal tab click load example data and verify it.
    • In field tab you can you can give the technical name of info objects in the template and you not have to map during the transformation the server will automatically map accordingly. If you are not mapping in this field tab you have to manually map during creation of the transformation in InfoProviders.
    • Activate DataSource and click “read preview” data under preview tab to see DATA.
    • Create InfoPackage by right clicking DataSource and in “schedule” tab click “start” to load data to PSA.( make sure to close the flat file during loading )
    4) Creation of data targets
    • In left panel select InfoProvider
    • Select created InfoArea and right click to select “Insert Characteristics as info provider”
    • Select required InfoObject
    • Under that InfoObject select subtype as attributes / Text / Hierarchies
    • Right click on attributes / Text / Hierarchies and select create transformation.
    • In source of transformation, select object type ( DataSource ) and specify its name and source system ( Note: Source system will be a temporary folder or package into which data is getting stored. )
    • Activate created transformation
    • Create Data transfer process (DTP) by right clicking the master data attributes
    • In extraction tab specify extraction mode ( full /delta )
    • In update tab specify error handling ( request green/request green/ Deactivated/ No update No reporting )
    • Activate DTP and in execute tab click execute button to load data in data targets. Monitor the request
    •  Go to InfoProvider and right click the InfoObject  and select “Maintain master data” tab to see whether data has been uploaded or not.
    To Load transaction Data
    Creation of DataSource (PSA)
    ·     In the left panel select DataSource. 
    ·     Create application component (AC).
    ·     Right click AC and create DataSource.
    ·     Specify DataSource name, source system, and data type (Transaction data).
    ·     In general tab give short, medium, and long description.
    ·     In extraction tab specify file path, header rows to be ignored, data format (csv) and data separator ( , ).
    ·     In proposal tab load example data and verify it.
    ·     In field tab you can you can give the technical name of info objects in the template and you not have to map during the transformation the server will automatically map accordingly. If you are not mapping in this field tab you have to manually map during the transformation in InfoProviders.
    ·     Activate data source and click “read preview data” under preview tab.
    Create info package by right clicking data source and in schedule tab click “start” to load data to PSA.( make sure to close the flat file during loading )
    Creation of data targets
    ·     Right click on ODS or InfoCube and select “create transformation”.
    In source of transformation, select object type (DataSource) and specify its name and source system (Note: Source system will be a temporary folder or package into which data is getting stored.)
    Creation of data targets
    ·     Right click on ODS or InfoCube and select “create transformation”.
    In source of transformation, select object type (DataSource) and specify its name and source system (Note: Source system will be a temporary folder or package into which data is getting stored.)
    ·     Activate created transformation.
    ·     Create Data Transfer Process (DTP) by right clicking the InfoCube.
    ·     Specify Source Of DTP (i.e. Object type: DataSource, DataSource: Name of DataSource, Source System: File.).
    ·     In extraction tab specify extraction mode (full).
    ·     In update tab specify error handling.
    ·     Activate DTP and in execute tab click execute button to load data in data targets.
    Regards,
    khyati.

  • Creating source system PC Files on productive system

    Hi,
    I have a problem, i need to create source system PC Files on productive system.
    I tried to do it in RSA1 - source systems.
    I could not create any source system - error message :
    "No entry for BW_USER in table RSADMIN available"
    Where should be problem?
    Thanks for help
       Radka

    Hi Radka,
    You have two options to do that:
    1. Write an ABAP program or use an Infohub to download the data on to your Prod Application server.
    2. Download the data to your PC and then FTP to your Prod App server. You can speak to your BASIS on this.
    Bye
    Dinesh

  • Creating source system: No entry for BW_USER in table RSADMIN available

    Hi,
    When i try to create source system in RSA1, when I choose SAP system from Release 3.0E (Automatic creation), I get this message:
    No entry for BW_USER in table RSADMIN available.
    What do I have to do to create source system.
    RFC connection are already made.
    Best regards,
    Uros

    hi Uros,
    you need to maintain ale user,
    rsa1->settings->global settings->glob settings
    enter bw user ale. normally ALEREMOTE is used.
    oss note 410952
    Symptom
    You receive the error message when trying to connect a source system to the Admininistrator Workbench:
    "No entry for BW_USER in table RSADMIN exists" (message number RSAR 059).
    Additional key words
    RSAR059, APO, RSADMINA
    Cause and prerequisites
    In table RSADMINA, the BW user is not maintained for ALE.
    Solution
    Maintain the entry using the following path:
    Call Administrator workbench (transaction RSA1).
    From the 'Settings' menu, select Global Settings'.
    If an entry already exists in the field "BW user for ALE", delete this.
    Enter the correct names for the BW users in this field.
    Save the entry.
    You must restart the Administrator Workbench (RSA1) now.
    The source system can now be linked without errors.
    hope this helps.

  • Portal Runtime Error while creating  new system in portal content

    Hi
      Can anyone  solve my problem, i am geting error while creating new system in p ortal content
    Portal Runtime Error
    An exception occurred while processing a request for :
    iView : pcd:portal_content/com.sap.pct/admin.templates/iviews/editors/com.sap.portal.templateSelection
    Component Name : com.sap.portal.admin.templateselectionwizard.default
    com/sap/portal/iviewserver/cache/OClass.
    Exception id: 11:29_26/12/06_0014_5891950
    See the details for the exception ID in the log file

    Hi,
    Check this link for creating system object
    http://help.sap.com/bp_epv260/EP_EN/documentation/EP/N03_BB_InstallGuide_EN_US.doc
    Regards
    Arun

  • RUNTIME ERROR WHILE CREATING NEW SYSTEM IN EP6

    Hi
    Can anyone solve my problem, i am geting error while creating new system PORTAL FOR to connect biw 3.5 system
    Portal Runtime Error
    An exception occurred while processing a request for :
    iView : pcd:portal_content/com.sap.pct/admin.templates/iviews/editors/com.sap.portal.templateSelection
    Component Name : com.sap.portal.admin.templateselectionwizard.default
    com/sap/portal/iviewserver/cache/OClass.
    Exception id: 11:29_26/12/06_0014_5891950
    See the details for the exception ID in the log file
    thanks in advance
    Rock

    hi,
    check the log file and let me the the error.
    manish

Maybe you are looking for

  • Unable to open the detail report in the same page/window

    When i use the "Navigate to Web Page" action link to navigate to the detail report, the detail report is opening in new window. Is there any way that the detail report can be opened in the same page/window.

  • How do I list all of the table names in my excel database

    I am writing code for an electronic sales board display in my office. unfortunatly the datasource that is available to me is an excel file that is updated by the sales manager every day. each sales persons information is listed in a different tab and

  • Any idea why InDesign CS5 doesn't open fully in Windows XP?

    When I try to open an InDesign CS5 file in Windows XP, the application appears in the task bar but does not open in the window. I tried right-clicking the icon in the task bar to "maximize" the window but this has no effect.  This problem seems to ha

  • I cant get my apple tv to see my ipad

    How do I get my apple tv to see my I pad?  I want to stream my slingbox

  • Help! How do I get rid of 10,000 duplicates???

    PLEASE can anybody help me? Whenever I change computer, reload the operating system or load itunes updates I end up with SEVERAL THOUSAND duplicated items. Sometimes it is just two tracks per album, sometimes up to TWENTY or so. I have to go through