Error In InfoObject Activation - Characterstic Blocked By Conversion

When I am going to Activate 0APO_PROD  the error message is
1. The SID table for 0APO_PROD cannot be filled
2. The InfoObject 0APO_PROD is Blocked by Conversion.

Hi
just on trial basis u can try tcode se14 delte the sid table recreate it and then activate the infoobject
thanks
puneet

Similar Messages

  • Characteristic Infoobject is blocked by conversion

    Dear All,
    Getting message as(Characteristic Infoobject is blocked by conversion).
    Unable to activate the infoobject.
    Does anybody faced the issue before.
    Thanks.

    Did you change the data type/DDIC for the info-objects. If yes, then delete the data first before acitvating it
    refer: info object  activation problem

  • Transport Error: Characteristic is blocked by conversion

    Hello Everyone,
    I had created an Info Object in my development system with some attributes and also compounded with certain other IO. After loading it, I transported it to Quality.
    Then I modified the Info Object in development system by adding some navigational attributes and some more compounding. I loaded it again, tested it and then transported it. But it is giving an error now. The log says " The conversion of master data tables from characteristic ZABC is not completed. Characteristic ZABC can not be changed until this conversion has been successfully carried out."
    Steps I did to resolve the issue:
    1) Deleted the data from Q. Adjusted the tables using SE14 in Q. Collected the object in a new request and transported it again. It dint work.
    2) I checked the consistency of tables for this Info Object using SE14. Everything was consistent. There is a SAP Note that talks about this issue: 1248769. But for that I need Basis support.
    Why am I facing this problem? Is there a consistent way to solve the issue because this might happen with any info object as we keep modifying the info object's over period of time.
    Regards,
    Abhishek

    It may be because of conversion lock in the characterstic. You can check it in "Extras --> Remove conversion lock" in the characterstic.

  • "Characteristic is blocked by conversion" -- "No Nametab Exist"

    Hi all,
    I have a serious problem. I have an infoobject with master data time dependent. I have switched one field from "Time-Dependent" to "not Time Dependent". In development environment no problem arises.
    When transporting in quality environment, the Change request goes in Red with following message:
    Table /BI0/PXXX: Error in creating index 0 (2)
    Characteristic 0XXX is blocked by conversion
    I check in quality and I see that the /BI0/QXXX table is not active. When I try to activate it, the following error message appears:
    No active nametab exists for /BI0/QXXX
    Termination due to inconsistencies
    Table /BI0/QXXX (Statements could not be generated)
    Any ideas?
    Thanks,
    Gianluca

    OSS Note 211492

  • Characteristic 0BPARTNER is blocked by conversion(Status 6)

    Hi
    I have added added 3 attributes to 0bparnter while activating error came.i removed 2 atributes and activated againg i got  error :Characteristic 0BPARTNER is blocked by conversion(Status 6) .infoobject has data which loading from crm.i found sapnote_0000325296 can i apply.do i need delete data or without also possible to apply this note.

    Hello,
    Adding an attribute should not be a problem in any infoobject.
    You can delete the data from the infoobject if its not used in any cube or if the cubes where its used are not loaded or contains no data.
    Otherwise you will have to delete the data from the cubes first and then from infoobject.
    This will allow you to change the infoobject.
    Even the OSS notes looks old one..so just do a verification if its already applied or not.
    Regards
    Ajeet

  • Characteristic 0TCTUSERNM is blocked by conversion

    Dear All,
    I am trying to activate the infoobject 0TCTUSERNM but it is giving error as below,
    Characteristic 0TCTUSERNM is blocked by conversion
    Message no. R7476
    Diagnosis
    The conversion of master data tables from characteristic 0TCTUSERNM is not completed.
    System Response
    Characteristic 0TCTUSERNM can not be changed until this conversion has been successfully carried out.
    Procedure
    Activate characteristic 0TCTUSERNM. The block will be removed following a successful activation.
    When I activate the infoobject, it is giving short dump.
    Does anyone have faced such issues?
    I tried force conversion in SE14 and also tried to activate and adjust tables in SE14 for this infoobject. It didn't helped.
    Any pointers to solve the issue will be helpful.
    Regards,
    Niraj

    Hi,
    I tried both the options suggested by you. Deleted the table from SE14 and adjust and activate. The issue did not resolved.
    i tried activation in background and job was getting cancelled.
    To solve the issue I went to infoobject> Extras>Remove conversion lock
    it gace a warning and then activated manually.
    Thanks for all the suggestions.
    Regards,
    Niraj

  • Characteristic is blocked by conversion (status 4)

    Dear all,
    There is a infoobject had many nav attributes,and much data in master data table.
    And then,i change nav attributes from time-dependent to notime-dependent.
    when i active it, there was error,and is blocked by conversion.
    So, status of the char is inactive, not executable.
    I Delete lock in SM12 ,and it didn't help. Locks appear again.
    error message shows the following:
    Internal Activation (InfoObject )
    Preprocessing / Creation of DDIC Objects for InfoObject ZCO_ELMNT
    Characteristic ZCO_ELMNT : Converting the Master Data Tables
    Table /BIC/PZCO_ELMNT: Error in creating index 0 (2)
    Resetting of Incorrect Objects Back to the Active Version (InfoObject )
    Preprocessing / Creation of DDIC Objects for InfoObject ZCO_ELMNT
    Characteristic ZCO_ELMNT is blocked by conversion
    How to active the IO,or delete the block from IO?
    Best regards,
    Plato

    I was facing this problem in bi 7.0 . the object can be unlocked by using TCODE RSA1OLD.
    Go to RSA1OLD.
    Double click on the object.
    then from menu, choose EXTRAS->REMOVE CONVERSION LOCK.
    This will remove the lock and will allow you to change the object.
    Change, save and activate the object. (You can skip this and can do from RSA1 also, just remove lock in this case)
    Change and save the object from here and come out of your all transactions. (Log Off from system)
    Now, as you have changed the object from RSA1OLD T-Code , it might not be type compatible for RSA1.
    So, go to RSA1, you will find that object unlocked. Change the same object (For sake of formality) and save and activate the object.
    This will create the active version of object in RSA1.
    Your problem is solved now.
    Hope this will work for you.

  • Characteristic 0MATERIAL is blocked by conversion

    Hi experts,
    I am transporting the 0MATERIAL changes into production (after extra navigational attribute added), while importing into production system, its giving below error message.
    Characteristic 0MATERIAL is blocked by conversion
    the new navigational attribute is active in production system.
    how to resolve this issue?
    regards
    venuscm

    Hi,
    Kindly review this SAP Note 1177708 - CHECK: Change time-dependent attribute to time-independent
    For existing data, a time-dependent attribute can only be changed to time-independent if there is exactly one attribute value for each characteristic value in the existing data. Even though there are several attribute values, the check may in some cases report values to be unique. However, the characteristic activation terminates. The subsequent inconsistent state can be cleared only manually.
    Please also read & follow the recommendations in SAP Notes:
       325296   Conversion lock: Characteristics cannot be edited
       451773   Inactive characteristic cannot be activated (inact.
    Rgds,
    Colum

  • Characteristic ZEMPLYETD is blocked by conversion

    hi
    i am geting this error while activating of time depandant of employee. ple let em know
    Characteristic ZEMPLYETD is blocked by conversion

    Hi,
    check below link,
    R7476 - Characteristic OMATERIAL is blocked by conversion
    Regards,
    Viren

  • Characteristic USITMMPE is blocked by conversion

    I tried to activate an InfoObject and I got:
    Characteristic USITMMPE is blocked by conversion. Now I am unable to make any change to this InfoObject. How to unblocked it? Thanks.

    Did you change the data type/DDIC for the info-objects. If yes, then delete the data first before acitvating it
    refer: info object  activation problem

  • Characteristic 0EMPLOYEE is blocked by conversion

    Hi Gurus.
    I added 2 Attributes to 0EMPLOYEE infoobject and made them navigational. Now, when I try to activate 0EMPLOYEE it times out and I get this message when I come and try to enter edit mode for 0EMPLOYEE:
    Characteristic 0EMPLOYEE is blocked by conversion
    Message no. R7476
    Diagnosis
    The conversion of master data tables from characteristic 0EMPLOYEE is not completed.
    System Response
    Characteristic 0EMPLOYEE can not be changed until this conversion has been successfully carried out.
    Procedure
    Activate characteristic 0EMPLOYEE. The block will be removed following a successful activation.

    Hi Dinah,
    Yes, I was able to fix this.
    You need to do the following. In BW, go to tcode SE14 (ABAP Dictionary: Database Utility). Enter the table name that is causing the problem in the Obj. name field. In my case that was the SID table, e.g. /BIC/YEMPLOYEE. You can display all the infoobject tables by typing in EMPLOYEE  (your InfoObject name) and F4 for lookup.
    Once you type in the correct table name, click on Edit button. On another screen, click on Delete data radio button. Then do an Activate and adjust database. If that does not fix it ..also ..come back and click on Delete database table button.
    Hope this helps.
    Thanks

  • IPad+iMessage 'error occured during activation'

    hi there.
    i'm trying to connect my ipad to my imessage account which i have on my iphone.
    I've researched the problem and i have updated onto the latest iOS 7 update, reset network setting back to factory, put time to auto (everything short of wiping my ipad completely which im reluctant to do)
    can anyone help me as my iphone tends to run out of battery mid conversation and obviously that's inconvenient
    thank you!!! 

    I assume that you saw this troubleshooting article, but did you see that you should toggle the settings on and off for Messages after each attempt?
    If you see "Waiting for Activation", "Activation unsuccessful", or "An error occurred during activation"
    These messages occur when your iPhone is trying to activate your phone number with iMessage or FaceTime.
    To resolve these status messages, follow these steps. After each step, turn FaceTime and iMessage off and on again in Settings > Messages and Settings > FaceTime.
    Update to the latest version of iOS.
    Make sure that you have a cellular network connection with your cellular provider. You need a cellular network connection to activate iMessage and FaceTime with your iPhone phone number.
    Go to www.apple.com in Safari to make sure that you have a data connection. You need a data connection to activate iMessage and FaceTime with your iPhone phone number.
    Make sure that you can send and receive SMS. You need a valid SMS messaging plan to activate FaceTime and iMessage.
    Make sure that FaceTime hasn't been restricted: tap Settings > General > Restrictions > FaceTime.
    Set iPhone to the correct time zone: tap Settings > General > Date & Time.
    Note: If Set Automatically is on but the incorrect time zone appears, turn Set Automatically off and choose the correct time zone, date, and time.
    Contact your carrier to verify that there are no restrictions, blocks, or filters on text messages. Restrictions, blocks, or filters on text messaging will prevent iMessage and FaceTime registration from completing.
    If "Waiting for Activation" still appears after you perform these steps, turn FaceTime and iMessage off and on in Settings > Messages and Settings > FaceTime. You may need to wait up to 24 hours to complete activation. Most attempts will take less than an hour, but some attempts may take up to 24 hours. If your issue isn't resolved after 24 hours, please contact Apple for assistance. If you've recently performed a remote wipe on your iPhone, wait 24 hours from the time you performed the remote wipe, and then turn iMessage off then back on.You can still activate iMessage and FaceTime with your Apple ID when these status messages appear. You can see that you've activated FaceTime and iMessage with your Apple ID by tapping:
    Settings > FaceTime > You can be reached by FaceTime at:
    Settings > Messages > Send & Receive > You can be reached by iMessage at:

  • Error occurs while activating a 'Write Optimized' DSO.

    I am getting error " There is no PSA for infosource 'XXXX'  and source system 'XXX' while activating a newly defined DSO object.
    I am able to activate a Standard DSOs, however the error occurs while activating a 'Write Optimized' DSO

    Hi,
    For write optimised DSO, check if you have tick the uniqueness of the records. If you check that and if there are two same records coming from source in one go, then you will get error
    From SAP help
    You can specify that you do not want to run a check to ensure that the data is unique. If you do not check the uniqueness of the data, the DataStore object table may contain several records with the same key. If you do not set this indicator, and you do check the uniqueness of the data, the system generates a unique index in the semantic key of the InfoObject. This index has the technical name "KEY". Since write-optimized DataStore objects do not have a change log, the system does not create delta (in the sense of a before image and an after image). When you update data into the connected InfoProviders, the system only updates the requests that have not yet been posted.
    Thanks
    Srikanth

  • How to handle the plsql error occuring in the exception block

    We know how to handle exceptins which occur in BEGIN block.
    But am unable to catch the exception in the exception block. Am writing an erroeneous code so that the control will go to exception block and there is also one plsql error, but am unable to handle that error, it's returning the error to the calling environment.
    DECLARE
    cnt NUMBER(5):=0;
    BEGIN
    select 'debalina' INTO cnt from dual;
    DBMS_OUTPUT.PUT_LINE(to_char(cnt));
    EXCEPTION
    WHEN invalid_number THEN
    DBMS_OUTPUT.PUT_LINE('error has occured inside begin block');
    cnt:='deba';
    WHEN OTHERS THEN
    DBMS_OUTPUT.PUT_LINE('error has occured inside begin block');
    END;
    please suggest me how to catch this exception?

    Hi,
    DECLARE
    cnt NUMBER(5):=0;
    BEGIN
    select 'debalina' INTO cnt from dual;
    DBMS_OUTPUT.PUT_LINE(to_char(cnt));
    EXCEPTION
    WHEN invalid_number THEN
    DBMS_OUTPUT.PUT_LINE('error has occured inside begin block');
    cnt:='deba';
    WHEN OTHERS THEN
    DBMS_OUTPUT.PUT_LINE('error has occured inside begin block');
    END;
    First of all your namee exception which you have posted i.e invalid_number itself is wrong.
    You need to use named exception VALUE_ERROR for catching the exception in the main block.
    SQL> DECLARE
      2  cnt NUMBER(5):=0;
      3  BEGIN
      4  select 'debalina' INTO cnt from dual;
      5  DBMS_OUTPUT.PUT_LINE(to_char(cnt));
      6  EXCEPTION
      7  WHEN Invalid_number THEN
      8  DBMS_OUTPUT.PUT_LINE('error has occured inside main block');
      9  end;
    10  /
    DECLARE
    ERROR at line 1:
    ORA-06502: PL/SQL: numeric or value error: character to number conversion error
    ORA-06512: at line 4
    SQL>  DECLARE
      2   cnt NUMBER(5):=0;
      3  BEGIN
      4  select 'debalina' INTO cnt from dual;
      5  DBMS_OUTPUT.PUT_LINE(to_char(cnt));
      6  EXCEPTION
      7  WHEN VALUE_ERROR THEN
      8  DBMS_OUTPUT.PUT_LINE('error has occured inside main block');
      9  end;
    10  /
    error has occured inside main block
    PL/SQL procedure successfully completed.Your doubt regarding catching the exception in exception block, you can execute as below, by nesting a Begin block inside the exception block itself.
    SQL> DECLARE
      2  cnt NUMBER(35):=0;
      3  BEGIN
      4  select 'debalina' INTO cnt from dual;
      5  DBMS_OUTPUT.PUT_LINE(to_char(cnt));
      6  EXCEPTION
      7  WHEN Value_error THEN
      8  DBMS_OUTPUT.PUT_LINE('error has occured inside main block');
      9  Begin
    10  cnt:='deba';
    11  Exception
    12  WHEN OTHERS THEN
    13  DBMS_OUTPUT.PUT_LINE('error has occured inside exception block');
    14  End;
    15  END;
    16  /
    error has occured inside main block
    error has occured inside exception block
    PL/SQL procedure successfully completed.Hope your doubt is clear.
    Twinkle

  • Error in Hierarchy activation

    Hello Experts
    I re loaded hierachy for 0material, infopackage failed with error "Error arose when activating the hierarchy; Hierarchy not active
    I tried activating using FM RRHI_HIERARCHY_ACTIVATE got error "There is no modified version for this hierarchy"
    I am able to see M and A versions of hierachy in hierarchy maintenance.
    but when i mannually try to activate hierarchy i get short dump with message 
    Short text
        Message type " " is unknown.
    What happened?
        Error in the ABAP Application Program
        The current ABAP program "CL_RSSH_MESSAGE_HANDLER=======CP" had to be
         terminated because it has
        come across a statement that unfortunately cannot be executed.
    Please help.
    Regards
    Sudeep

    Hi sudep,
                     did u done the attribute change run for hierarchy after loading the hierarchy?.....
    try the below steps
    1) Load Hierarchy
    2) Save Hierarchy
    3) Attribute CHange Run on the InfoObject.
    Run these in the same sequence and see if it solves the problem.
    Make sure that you have this Checkbox on:
    1) In Infopackage, in tab Hierarchy Selection, there is a small checkbox for 'Flag for Activation'. Make sure its ON.
    2) In Save Hierarchy Process Type, the same check box should be ON.
    Harikrishna N

Maybe you are looking for

  • Mavericks slow login/erratic performance

    I am having trouble with Mavericks on my Mac Mini.  I have eight user accounts (1 administrator, 1 guest, 2 regular users, and 4 managed with parental controls) and when logging in to any user it takes several minutes before everything is running at

  • Overprint Preview and Workspace are set to the same, but look different

    I'm working for something to be viewed on a screen, so I work in the sRGB IEC61966-2.1 (Edit > Color Setting > Working Spaces - RGB: sRGB IEC61966-2.1 ). I have set the Overprint Preview to the sRGB IEC61966-2.1 as well (View > Proof Setup > Device t

  • HTML Link ( a href)- wrong behaviour

    Hello, This simple code <a href="javascript:$('.div-feedback').fadeIn();"> doesn't work in my newest version of firefox 29.0.1. it works on chrome just fine as it should. rather than interpret as javascript, it reads as an url (opens the page "javasc

  • Cannot find the hana output adapter, please help me.

    I have downloaded the latest version of ESP in SAP software  Download center, here is the screenshot However, when I try to install the hana output adapter in the custom installation process, I couldn't find it. Here is the screenshot: please help me

  • Email Sapscript with an individual mail body

    Hi we are sending Sales documents via NAST and SCOT as email to our customer. Currently the document is converted into Pdf and added as attachment to the mail. We can only change the subject line. It is not possible for us to fill the mail body. The