Error in ODS Activation

Hi Friends,
I got error when the ODS activating in Process Chain.
The Error Messages are
1. Inconsistent aggregation behavior - activation will be terminated.
2 Activation of M records from DataStore object 0PUR_DS03 terminated
in the data target (ODS) the request are in Red but activated as it is showing Request For Reporting Available flag having Query symbol..means the requests are available for reporting.
What should be the possible reason
How should i rectify it.
Thanks&Regards
Anand

hi,
I have activated ODS manually yesterday. the chain ran today.
But today i got the below error while data is loading into ODS.
Error Message Below.
Runtime Errors         RAISE_EXCEPTION
Date and Time          07.04.2009 03:43:06
Short text
     Exception condition "NOT_EXIST" raised.
What happened?
     The current ABAP/4 program encountered an unexpected
     situation.
What can you do?
     Note down which actions and inputs caused the error.
     To process the problem further, contact you SAP system
     administrator.
     Using Transaction ST22 for ABAP Dump Analysis, you can look
     at and manage termination messages, and you can also
     keep them for a long time.
Error analysis
     A RAISE statement in the program "SAPLRSSM" raised the exception
     condition "NOT_EXIST".
     Since the exception was not intercepted by a superior
     program, processing was terminated.
     Short description of exception condition:
For detailed documentation of the exception condition, use
Transaction SE37 (Function Library). You can take the called
function module from the display of active calls.
Please sugeest to resolve the problem
Regards
Anand

Similar Messages

  • Error in ODS activation due to # character

    For last two days I have been getting the error in the process chain. The process chain stops at ODS activation because the data contains '#'. I have gone SAP Note 173241, which says that # value is allowed in data. Is there any way to remove # from the data. Thanks in advance

    It could be hexadecimal char in the load it would display as '#' but actually it would be some hexa char.
    Either you can track it based on the log and edit in PSA and see if you can correct it in R3 as well.
    We do have some of those come in our various desc fields, just modified a simple FM to strip our the not allowable char that are not in RSKC.
    let me know if u need the FM i'm using to strip out hexa
    Mayil

  • ABAP/4 processor: RAISE_EXCEPTION error while ODS Activation

    Hi all,
    We are facing the problem with ODS Activation.
    While ODS activation, we are getting error - "ABAP/4 processor: RAISE_EXCEPTION" very frequently .
    Could anybody please guide me why this error happened and how we can recover this error and is there any precautions to avoid this error.
    Thanks & Regards,
    Sudharsan

    Hi Sunil,
    Thanks for your reply.
    I dont have much knowledge on ABAP and how can you please let me know how this error resolved by your ADMIN team.
    Since we are facing this problem frequently, anybody tell me atleast, why this error happened?
    Regards & Thanks
    Sudharsan

  • Error during ODS activation- request deletion

    Hello Gurus,
    We had a problem during ODS activation, could you please help?
    We are on BW 3.1
    Activation of an ODS failed with the message, "Fiscal year variant MC is not maintained for calendar year 2009u201D, u201CError getting SID for ODS object ZODS_O02u201D and u201CError when assigning SID: Action VAL_SID_CONVERT table 0FISCPER."
    The expected data for 2009 didn't arrive, so the activation step in the proces chain has failed.
    What I've done is, just deleted the request from the ODS.
    But while this job was running, there was a short dump, and the same job was shown as cancalled under SM37. Though the request was successfully deleted from the ODS, it is showing as cancelled in SM37.
    I've given below the log details of the job.
    Job started
    Step 001 started (program RSDELPART1, variant &0000000003334, user ID ABCD)
    Delete running: ODS object ZODS_O02, from 310,818 to 310,818
    Delete is scheduled; Selection conditions were substituted
    Request REQU_4AZBURUGR09EXTAS8A9IRZUI4 successfully deleted from ODS object ZODS_O02
    ABAP/4 processor: MESSAGE_TYPE_X
    Job cancelled.
    Could you please clarify the reason for the short dump and for the job getting cancelled?
    thanks in advance,
    Raj

    Hi,
    As an help i suggest you can first check the corresponding message for the "Message type X" in transaction se91.
    Follow the below procedure for the same :
    1.Execute ST22 > Double click on any entries
    2.Go to Source Code Extract
    3.Locate u201C>>>>u201D and you will see Message
    i.e Message X041 (XX) in this example.
    - XX is the message class
    - 041 is the message class no. in the example above.
    4.Now open SE91.Enter the details we found from Source
    Code extract in ST22.Click Display
    5.Find the corresponding message.
    May be the message could much more elaborate your problem so it could be handeled properly.
    Thax & Regards
    Vaibhave Sharma

  • Invalid characters error while ODS activation

    I have 2 queries regarding Invalid characters
    1) I got following error while activating ODS.
    Value 'HYDERABAD - IV  COMMISSIONERATE ' (hex. '48594445524142414420<b>2D</b>204956A020434F4D4D495353494F') of characteristic ZEXCRG contains     invalid characters
       I added space (ALT+255) in RSKC as suggested in other threads and activated the ODS.('-' is already there in RSKC).
    Above record did not give any error but got the same error for another record.
    Value 'SURAT – II ' (hex. '535552415420<b>96</b>204949 ') of characteristic ZEXCRG contains invalid characters     
       Can anybody tell me why there is difference between in representation(HEX) of same char and which char should I add to RSKC to solve the error?
    2) RSKC_ALLOWED_CHAR_GET lists the space as default allowed char, so why do I need to add the same again?

    Hi Vikram:
    go to RSKC: do a ALL_CAPITAL. then do the permitted charcters in BW(do a F1 and copy all and paste). also, please be advised that add <b>~</b> (tilda) and take a closer look at the error you got and insert that there.
    hope it should fix the issue.
    assign points if helpful
    kalyan

  • SID Error while ODS activation

    Hi,
    I am getting the Invalid charcterisitc error while Activating ODS. This ODS consists 0vendor as attribute of 0material.
    Now I have checked the entires for this 0vendor with respective 0material and there is no entires found for Vendor. Then where should I change invalid char for vendor.
    regards,
    Venkat

    Hi Harish,
    I am getting the following error while activating the DSO (we are using BI 7.0).
    Value 're1090' (hex. '007200650031003000390030') of characteristic 0VENDOR contains invalid characters
    I could not find Invalid char in PSA  as 0Vendor is an attribute for 0material.
    My concerns are:
    1) If 0vendor is having Invalid Char the load should fail when we are loading data for 0Material.
    2) As per the error message I could not find any Invalid char to find out.
    3) Where should I change this Invalid char (0Vendor / 0materail).
    Regards,
    Venkat

  • Error while ODS activation

    Hi Every body,
              I got this error while activation of data in an ODS. The data is avaliable in the New dta atable , but while activation it is giving the errors of Invalid characters and error when assigning SID. Can anyone help.
    Thnaks in advance,
    Raj.

    I am facing similar problem in the 0FIAP_O03 ODS.
    One particular value 'CC ·µÐ¼þ' for field 0REF_DOC_NO gives error in Activation.0REF_DOC_NUM does not have any masterdata but the SID table is exists. We have ALL_CAPITAL in RSKC.
    One strage observation was when I tried loading this value[value copied from the error message in a PSA] in Developement Box it was successfull.
    I Do not understand if I am missing some setting in Production.
    The Errors are
    BRAIN 60  Value 'CC ·µÐ¼þ' (hex. '434320B7B5D0ADBCFE') of characteristic 0REF_DOC_NO contains invalid charact
    RSDRO 303 Error when assigning SID (details in long text) 
    The SID did not get created in Prod but was created in Dev. ODS is available for reporting and it has to remain such.
    If you have any Insights please help me as well.

  • Error During ODS activation

    Hi Experts:
                    I am loading data to ODS. From R/3 to Data Source (PSA) data gets loaded without any problem at all. But during activation in ODS, it fails.
    I am getting the following error:
    Error when assigning SID: Action VAL_SID_CONVERT table 0POSTXT  Message no. RSDRO302
    Value '#' (hex. '23') of characteristic 0POSTXT contains invalid characters Message no. BRAIN059
    Process 000046 returned with errors Message no. RSODSO_PROCESSING006
    Now I checked in PSA, I did not see any # sign any where. Plz help me with this.

    Hi,
    Try writing following code in the udpate routine of 0postxt.
    replace all occurence of '#' in 0postxt with '-'.
    Also , some logic like following can be built for entries which have blank line item text .
       if 0postxt = space .
                  0postxt = ' -' .
               endif.
    Check out and let us know .
    Hope that helps.
    Regards
    Mr Kapadia

  • Error in ODS activation/export datasource

    Hello Gurus,
    When I am activating an ODS 0CFM_O01, it gives the foll error. can u pls guide. thanks in advance
    DataSource 80CFM_O01 does not exist in source system BWCLNT700 of version A     
    Error when creating the export DataSource and dependent
    Error when activating ODS Object 0CFM_O01
    rgds

    hi,
    take a look oss note 597326-Activating ODS: Error when creating the export DataSource.
    base on that note, the activation error coz dependent object(s)-infoobjects not active, to eliminate the error we have to first have all the objects active. you may try in business content installation, collection mode 'manual', put 0CFM_O01, grouping 'only necessary objects', right click 0CFM_O01 and choose 'install all below' then 'install'. hope this helps.
    note 597326
    Activating ODS: Error when creating the export DataSource
    Symptom
    When you activate or transport ODS objects, the following errors appear in the log:
    "The creation of the export DataSource failed". Message number RSBM 035
    "Error &1 in function module &2". Message number RSBM 006
    "Error when creating the export DataSource and dependent Objects". Message number RSDODSO 169
    "Error when activating the ODS object &1". Message number RSDODSO 168
    Other terms
    RSBM 035, RSBM 006, RSDODSO 169, RSDODSO 168
    Reason and Prerequisites
    A characteristic involved is active but it is using new or inactive attributes.
    Characteristics involved are all characteristics used in the ODS object.
    Solution
    Check all characteristics involved as described in the following:
    Check the Compounding and Attributes tabs in the characteristics maintenance.
    All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.

  • Error in ODS activation in process chain

    I am getting errors when activating request using process chains.
    Error message is Message No. RSM1102.
    Please suggest if any notes apply for this.
    Regards,
    Nitin

    Hi,
    This happens when data is not acceptable to ODS  definition. Data need to be corrected in PSA.
    Check  for Infoobject which has caused this problem in the monitor details tabstrip. Delete request from datatarget after changing QM status to red. Correct data in PSA and update data back to datatarget from PSA.
    Cheers
    Raj

  • Runtime Error during ODS Activation: UNCAUGHT_EXCEPTION, Exception - CX_PARAMETER_INVALID_RANGE

    Hi,
    I was trying to activate an ODS while loading the data from a FlatFile using SAP BW 7.4.
    The Data was loaded completely in correct format in the PSA and also into the New Data and Change log tables in the ODS.
    But when trying to activate the ODS, it shows me an error.
    The description of the RunTime exception is :
    "An exception has occurred which is explained in more detail below. The exception is assigned to class 'CX_PARAMETER_INVALID_RANGE' and was not caught
    in procedure "GET_NEXT_PACKAGE" "(METHOD)", nor was it propagated by a RAISING clause. Since the caller of the procedure could not have anticipated this exception, the current program was terminated.
    The reason for the exception is: Parameter has invalid value: Parameter IM_TEMPERATURE has invalid value 01011900."
    Can you please help me solving this issue?
    Thanks,
    Bhaskar

    Hi Bhaskar,
        The message seems to be soft clear, and near of a bad value format, a parameter bad informed.
    "Parameter has invalid value: Parameter IM_TEMPERATURE has invalid value01011900" Try to pass a "0" in order to know if this is the parameter or field. And check the Data Type spected.
    Regards

  • Error in ods activation due to lack of roles

    Hi Experts,
    When i am trying to actvate ods its failed due to lack of roles in my server so which role i need to create for this?
    David

    activate ods  may cause to create new master data , so I think you may need to check sm37 and st22  to check which infoObject cause this error.
    RL

  • No sid found error in ods activation

    Hi,
    i got error like no sid found while loading data from one ods to another ods,any one give solution.
    Regards
    k.satish

    Can you paste more details of issue log
    see if there is any special character which is causing the SID failure...

  • Regarding error in ODS' activation.

    Dear All,
    Could you help me to solve this case please..
    I've problem like this,, so when i'm trying to load data from CRM i get the strange error.
    1. If i get into the monitoring (icon)/tcode : RSRQ. The status is green.
    2. BUT, If i manage the ODS (RSA1 - Manage ODS), the status there is red .
    3. The error is like this:
    Error when assigning SID: Action VAL_SID_CONVERT table ZTPROBDES.
    What i've done for solving :
    1. delete then reconstruct.
    2. re-fetch data from PSA to ods.
    But, the outcome is still same.
    Btw, i'm using Delta & BI. 7.0. for it.
    Could somebody here help me what to do ..
    Tks a lot .
    Regards,
    Niel.

    This error came due to master data porblem, that ODS  required master data, that master data is not avalible.
    procedure:
    Delete that record from ODS new tabel and activate. Before doing this inform to further people
    OR
    Edit PSA data for ZTPROBDES infoobject(field) give some existing value (ie ZTPROBDES value already in master data)and note the which record ur chaning  than reload to ODS before to this inform to next level person.
    OR
    This is the program for repair sid numbers(i.e it will asgin the temp. sid number to that)the try this RSDMD_CHECKPRG_ALL for repairing the SID numbers
    i hope this will be help
    Message was edited by:
            Soma Venkateshwarlu

  • Error in ODS activation : URGENT

    Hi !
    <b>ODS object 0FIAP_O03 was built incorrectly. Cannot update request REQU_CAZ1PIIRCEYV2WX9Z3H7MIZBU</b>
    <i><b>Diagnosis
        The data request was a delta update, meaning, the data basis in the
        source system has not changed since the last update.
    System response
        Info IDoc received with status 8.
    Procedure
        Check the data basis in the source system.</b></i>
    Could any body suggest what should I do ?

    Servus,
    try to delete the first initialization and then load it again. After this delta upload will function. I had the same trouble.
    please change this post as "answered".
    regards
    Standa

Maybe you are looking for

  • Adobe Bridge & Raw in Mac

    I have downloaded Ps(The latest)and tryed to download Br,but i can´t find it in Ps.I dont find Raw either,so how to do this in my macbook pro. mvh oddvar knutsen

  • Help Installing Forms 11G on Windows 7 64 Bit

    I am trying to install. I installed 64 bit Java JDK, Weblogic generic server, and finally Portal, Forms, Reports and Discoverer (11.1.1.2.0). When the Portal, Forms, Reports, and Discover install get to step 6 of 16, it reports: INST-07408: Unable to

  • Has anyone had issues with putting a 1TB hard drive into an early 2008 20 inch iMac?

    I have been trying to upgrade my 250GB hard to a 1TB Western Digital Blue hard drive.  So far I have tried the following... * CCC clone * Super Duper clone * Disk Utility clone * Fresh install of Mavericks and Migration Assistant Each time I do these

  • Problem with Adhoc Query

    Hi I am trying to take out a report on employee's education through Adhoc query. When I am taking the report for all employees it is coming out perfectly. But when I am giving some selection conditions it is showing me blank fields. Suppose I want se

  • Regarding AUFK, AUAK / COSB tables

    Hi all, I am working on WIP Aging Report and for this, i need to extract the data from the AUFK and COSB tables. I was told to get all the AUFNR values from AUFK table and then the values of AUFK-AUFNR will match with COSB-OBJNR values excluding the