     We faced error an hierarchy load. Error records written to application log.The level of the node ID 000284 does not suit the lev. of the higher lev. node.
Help to solve this error.
Thanks,

Hi Hema latha...
Please find the below link this may helpful ........
http://help.sap.com/saphelp_nw04/helpdata/EN/80/1a6729e07211d2acb80000e829fbfe/frameset.htm
http://help.sap.com/saphelp_nw04s/helpdata/en/52/671595439b11d1896f0000e8322d00/frameset.htm
/people/kristoffer.engh2/blog/2007/04/03/roles-and-authorizations
Regards
Sudheer

Similar Messages

  • Error in the hierarchy structure - Data Load Failure

    Hi
    We are having a regular Master data hierarchy Full load: 0WBS_ELMT. This data load is from the SAP R/3 source system. It was failed today with following message:
    Error in the hierarchy structure     
    Node ID 00016749 does not exist.
    Node ID 00005867 starts an endless loop
    Node ID 00001367 has not been included in the hierarchy
    Can any one help me out to solve this issue?
    Best Regards,
    Venkata.

    hi,
    refer to this thread.
    No hierarchy displaying in the Maintain Hierarchies

  • Product :  Errors in attribute hierarchy structure SAP BCA   000164

    Hi All ,
    When ever i create /Display /Change Product in
    Financial Supply Chain Management --> In House Cash > Master Data>Product Definition--> Product --> Create /Change/Display
    system through below mentioned error .
    I tryed to resolve problem as per below mentioned program through se38 , but still getting same error
    Errors in attribute hierarchy structure SAP BCA   000164
    Message no. FIPR217
    System Response
    An error was found in the attribute hierarchy.
    In some cases, it is not possible to display the attribute hierarchy without having to correct the errors first.
    Procedure
    It is recommended that you run the FIPR_CLEAN_ATTRIBUTES (by using transaction SE38).  This report can recognize errors, and it attempts to correct them automatically.
    Caution: This report can change your table entries permanently.
    Once this report has run, you need to check the hierarchy structure, and make any necessary changes.
    Regards
    Prakash Sharma

    Hi,
    the realignment (KEND) does not change the line item tables (CE1***, CE2***), thats why they remain unchanged.
    The line items in CE1**** can not be changed. If you really want to have new line items (with the new prod. hierarchy) try in test-client if the use of report RKECADL1 and the new transfer to CO-PA for the deleted line items (KE4S, KE4SFI,...) can help you (SAPNET-note 69370 for details).
    CE2**** + SQL-error: As per now, I don't have an idea how to deal with that cases.
    best regards, Christian

  • Error in the Hierarachy structure

    Hi Gurus,,
    I got one error like Error in the Hierarach structure while daily loading from R/3 to BW , so pleace give me the solution for this error:,how to salve it
    Thanks& in advance
    Nave

    hi
    See the hierachy version or hierachy levels in both sides.
    Are they in same version and trying to upload data for the correct level
    Hope this helps
    Regards
    Ganesh N

  • How to create Formulas in the hierarchy structure

    Hi,
    Is it possible to create formula with in the hierarchy structure, so that the both hierarchy drill down and the created formulas can be displayed at the query output. Please give the valued suggestions.
    Thanks
    VEERU.

    Hello
    You have in this case to create a structure and select the node concerned in your hierarchy.
    Then create a new formula based on your previous selection for example.
    Rgds

  • How to understand the hierarchy structure of 0PLANT io?

    how to understand the hierarchy structure of 0PLANT io ?
    i can understand the hierarchy structure of PRODUCT io,
    well, i hope someone could explain the hierarchy structure of 0PLANT io
    thanks.

    Hi
    You can use following hierarchy tables
    RSTHIERNODE - Texts of Non-Postable Hierarchy Nodes
    RSEHIERNODE - Master Data: Hierarchy Nodes that Cannot Be Posted To
    RSMHIERNODE - Master data: Hierarchy nodes that cannot be posted to
    RSHIEDIR - Hierarchy Catalog
    RSHIEDIRT - Hierarchy directory texts
    RSREQHIER - Data Request hierarchy
    RSROLEHIERARCHY - Role hierarchy
    In addition to these have a look at K table & I table for 0PLANT.
    K table - Hierarchy SID table
    I table - Hierarchy structure table
    Hope this will help..!!
    Thanks,
    Vikrant

  • How to create the Hierarchy Structure in BeX

    Hi,
    We have a cost center IOBJ MD, and our source system does not have the feasibility to create hierarchy to load it. But the business gave a hiearchy structure in flat file, and want to get the cost center hierarchy in bex.
    How do we do that ? Please suggest.
    Thanks
    RK

    Hi,
    A hierarchy can be created in the system by two ways:
    By hand:
         I would recomend to create by hand if the hierarchy has a few nodes or if the hierarchy will stay without changes for long.
         RSA1 --> Look for your infoobject and "create hierarchy". Then, you can create the folders and nodes that you need and dont forget activate it
    This option is the quickest and easier, if you could go for it.
    Loaded by flat file.
         If the hierarchy has many many nodes or if it will change its values quite often, it will be a good idea to develop stractors, infopackage and so on for loading the information from file file.
    There are plenty of information of the Internet about how to do it.
    From my own experience, it would be easier to build the extractor in the old version (rsa1old).
    I hope that it helps!

  • The row structure of the table BANFTAB is incorrect

    Dear Experts,
    I get right here the error message
    The row structure of the table BANFTAB is incorrect
    ZBANFN is a table type and has the line tab BANFN.
    Can you pls tell me what is wrong here ?
    FUNCTION Z_CHANGE_EBAKZ_FLAG.
    *"*"Lokale Schnittstelle:
    *"  CHANGING
    *"     VALUE(BANFTAB) TYPE  ZBANFN
      data lt_eban type table of eban.
      data ls_eban type eban.
      SELECT * FROM eban into table lt_eban where BANFN IN BANFTAB AND EBAKZ EQ 'X'.
      IF SY-SUBRC IS INITIAL.
        LOOP AT lt_eban INTO ls_eban .
          ls_eban-EBAKZ = ' '.
          modify eban from ls_eban.
        ENDLOOP.
      ENDIF.
    ENDFUNCTION.

    Hello,
    You have to use a ranges table in this case.
    FUNCTION Z_CHANGE_EBAKZ_FLAG.
    *"*"Lokale Schnittstelle:
    *"  CHANGING
    *"     VALUE(BANFTAB) TYPE  ZBANFN
      data:lt_eban type table of eban.
      data:ls_eban type eban.
    data:
    l_r_banfn type range of banfn,
    l_wa_banfn like line of l_r_banfn,
    l_wa_banftab like likne of BANFTAB.
    loop at banftab into l_wa_banftab.
    l_wa_banfn-sign = 'I'.
    l_wa_banfn-option = 'EQ'.
    l_wa_banfn-low = l_wa_banftab-banfn.
    append l_wa_banfn into l_r_banfn.
    clear l_wa_banfn.
    endloop.
      SELECT * FROM eban into table lt_eban
      where
      BANFN IN L_R_BANFN "BANFN IN BANFTAB
    AND EBAKZ EQ 'X'.
      IF SY-SUBRC IS INITIAL.
        LOOP AT lt_eban INTO ls_eban .
          ls_eban-EBAKZ = ' '.
          modify eban from ls_eban.
        ENDLOOP.
      ENDIF.
    ENDFUNCTION.
    or you can use FOR ALL ENTRIES :
    FUNCTION Z_CHANGE_EBAKZ_FLAG.
    *"*"Lokale Schnittstelle:
    *"  CHANGING
    *"     VALUE(BANFTAB) TYPE  ZBANFN
      data lt_eban type table of eban.
      data ls_eban type eban.
      SELECT * FROM eban into table lt_eban
      FOR ALL ENTRIES IN BANFTAB "--> Add this
      where BANFN = BANFTAB-BANFN
      AND EBAKZ EQ 'X'.
      IF SY-SUBRC IS INITIAL.
        LOOP AT lt_eban INTO ls_eban .
          ls_eban-EBAKZ = ' '.
          modify eban from ls_eban.
        ENDLOOP.
      ENDIF.
    ENDFUNCTION.
    Try this & let me know in case of any issues.
    BR,
    Suhas
    Edited by: Suhas Saha on Feb 10, 2009 5:43 PM

  • "The Dictionary structure or table "*C865" is either not active or does"

    Hello experts,
    I have a transaction - VKOA. I get the following error on executing this t-code. The program used by this t code is SAPL089C.
    The error is
    Runtime errors         SYNTAX_ERROR
    Occurred on     11/23/2009 at   05:12:58                                                                               
    Syntax error in program "SAPL089C ".                                                                               
    What happened?                                                                               
    The following syntax error occurred in the program SAPL089C :                                  
    "The Dictionary structure or table "*C865" is either not active or does not exist."                       
    Error in ABAP application program.                                                                               
    The current ABAP program "SAPLSVIM" had to be terminated because one of the                    
    statements could not be executed.                                                                               
    This is probably due to an error in the ABAP program.          
    Error analysis             
    The following syntax error was found in the program SAPL089C :                       
    The Dictionary structure or table *C865 is either not active or does not exist.
    Please suggest a suitable solution to this problem...
    Many Thanks in adv.
    Kunal
    Edited by: kunal kotak on Nov 23, 2009 6:53 PM

    Hi ,
    I will try the solution propesed by Max.
    In the meantime, I would like to confirm if there is something related to SAP Note # SAP Note 72121. Refer the following details from the note.
    Symptom
    When you maintain account determination (FI or SD), you get the error
    message:
    The DDIC structure or table "*C400" is not active or does not exist.
    OR
    The system writes a dump with DBIF_NTAB_TABLE_NOT_FOUND, C400 was not
    found.
    C401 can also appear instead of C400.
    Additional key words
    Tables C400, C401.
    Program: SAPL089C, L089CT00
    Transaction: VKOA
    Solution as per the note
    1. Execute the program RV12A002. On the selection screen, enter Usage C,
    Tables 400 to 401.
    WARNING: Make sure that you only delete C400 and C401!
    Execute the program.
    2. Execute program RV12A001. On the selection screen, enter Usage C and
    mark 'Reports & Screens'.
    Can there be sometihing similar to this for C865 table as well. Just a thought.

  • Creation of hierarchy structure

    Hi all,
    I need help bulding a hierarchy structure which is time dependent (hierarchy structure time dependent). I want to know if the hierarchy structure only depends on the NodeID and ParentID or if the time information is (date from and date to) is also taken in concern?
    I made a test and it seems that the hierarchy structure only depends on the node id and the parent id information.
    Please confirm.
    Points will be assigned.
    Cheers,
    Marco

    Hi guys,
    here is an example from the data that is passed to the transfer structure:
    NODEID
    INFOOBJECT
    NODENAME
    PARENTID
    DATETO
    DATEFROM
    TXTSH
    TXTMD
    TXTLG
    1009920
    FACILITY
    1009920
    1
    99991231
    10000101
    1009921
    FACILITY
    1009921
    1009920
    20080630
    10000101
    1009922
    FACILITY
    1009922
    1009921
    20080630
    10000101
    1009925 |FACILITY                |1009921                          |1009920   |99991231|20080701| |                    |                                        |                                                            |
    1009926
    FACILITY
    1009922
    1009921
    99991231
    20080701
    The result in the BW is that
    1009920 has the children 1009921 with 1.1 - 30.06.2008 and 1009921 1.7. - end
    the children 1009922 are both added to 1009921 1.1 - 30.06.2008!
    Correct would be that 1009922 1.7. - end is linked to 1009921 1.7. - end
    Regards,
    Marco

  • Initialize Orgchart with expanded right leaf of the Hierarchy Tree

    Hello dear all,
    our client has set a requirement, that I will try to describe and ask for your help . Before that, I would like to mention two things .
    First, we are using Nakisa Live 2.0 and we cannot change it .
    Second, the client considers this feature as an absolute requirement for the project to go live, so we have to come up with a solution .
    No, the problem .
    When the OrgChart is loaded, by default it shows the first two levels of the Hierarchy structure .
    What the client needs, is that we have on side of the tree expanded in four levels, and the other side, expanded in two .
    So this is the Default .
    _________ 80000001
    80000002_________ 80000003
    And this is what our client needs .
    _________________ 80000001
    ________ 80000002________ 80000003
    ________________80000004__________80000005
    _________80000006___80000007__80000008___80000009
    What we have managed to come up is the following .
    First, we set up AppResources, to expand the tree up to the fourth level, for all the branches .
    Then we have enhanced the abap function HCM_GET_ORGSTRUCTURE_AS_XML_IN that returns the xml tree structure, removing all the leaves of the left branch ( which in our example is everything that is under 80000002 )  .
    The idea is, that when the OrgChart Initializes, the function is called with OBJID = 80000001 (the root) while each time we click on the expand button of a subsequent  orgunit, it is called using this units value, eg 80000003 . At that point, our enhancement allows the function to retrieve all the necessary data .
    When we first tried this solution, we noticed that the orgunit 80000002 comes without expand buttons, but we managed to overcome this by editing some XML files (OrgChartBoxControlsXSL.xsl, OrgChartBoxPresentationXSL.xsl, NodeDetailXSL.xsl)
    But, the problem is that when we click on 80000002, the function is still not called so no data is fetched .
    We did check the html code produced and it seems ok (the expand button has the following onclick attribute : Javascript:TriggerEvent('expandNode', this, '50019824', 'de93808cb2074b7eb435cc95c2e954c0');  )
    So what we need is either an answer on why the function is not called, or a totally new way to implement this feature .
    Thank you all for your patience and your help .

    In the function module, what i did is the following. The FM HCM_GET_ORGSTRUCTURE_AS_XML calls the FM ZCM_GET_ORGSTRUCTURE_AS_XML_IN. There we call HRWPC_RFC_GET_COL_CONTENT, which returns two structures
    tempobjecttable   and structuretable .
    What we do there is this .
    If objid = 80000001,
          if znakisalog-active = 'Y' .
            loop at structuretable where seqnr eq 4 .
              clear structuretable-pdown .
              modify structuretable .
            endloop .
          endif .
    endif
    where the line with seqnr = 4 is the objid 80000002 . By clearing the field pdown, we remove any reference to subsequent orgunits .
    Now it is supposed that when we click on Orgchart box for 8000002 the above function will be called again, but the above code will not run and we should get the data we need .
    As for the XML files, i commented out some code like that :
    <!--<xsl:if test="$expand = 'True'">
         <xsl:if test="$expanded != 'True'"> -->
    in order to make the expand buttons show in every case .

  • Service hierarchy structure

    Hi all,
    We are upgrading from SRM 5 to SRM 7.0 EHP1 with ECS.
    When a service shopping cart is created in SRM 5,a hiererachy structure is created for each item i.e. PARENT and then ITEM .
    We want to create service carts and PO's w/o the hierarchy structure.Is that possible in SRM 7?
    Pls advise.

    Hi Ranjan,
    I'm talking about service PO's which are created using the link "ORDER" in SHOP ONE screen.
    WHen service PO's are created using this link,each service item has 2 nodes:
    1 parent and other with the actiual item details.
    E.g. SC with 2 items in SRM will actually have 4 line item structure. will also have the same structure.when the PO for this cart replicates to ECC,in ECC thre will be only 2 item structure.
    Is there a way to create service PO's in SRM 5  and SRM 7 w/o the hierarchy structure?

  • Error while loading the Hierarchy to 0GLACCEXT

    Dear all ,
    I am trying to load a hierarchy ZEM 1 that is manually created in R/3. when I am executing the Infopackage its showing an Error that
    1.Record 8 :Node characteristic 0GL_ACCOUNT is not entered as hierarchy characteristic for 0GLACCEXT
    2.Too many error records - update terminated
    and what is the the concept of 0BAL_DPEND to be added as attribute to OGLACCEXT.
    Thanks

    Hi Dash ,
    I am providing the long test for the error ...Also can you tell me how I should use 0BAL_DPEND field as an attribute of Hieararchy of 0GLACCEXT. Coz i am supposed to do this
    <u>Hierarchy for Characteristic 0GLACCEXT with Attribute 0BAL_DEPEND
    The hierarchy for characteristic 0GLACCEXT is used as the financial statement version in BW queries. To technically enable the particular exception aggregation for contra items, the hierarchy table of characteristic 0GLACCEXT contains the attribute Balance-Dependency of a Hierarchy Node (technical name 0BAL_DEPEND).</u>
    The Long Error Message
    Diagnosis
        The nodes NODEID = [00000194, 00001627 ] have the same node names
        NODENAME = '10000000950090 '. This is not allowed because neither node
        is a leaf and both nodes are assigned to the same characteristic
        0GL_ACCOUNT .
        Note that a maximum of 50 characters is available for message variables.
        The node name NODENAME = '10000000950090 ' might not be displayed in its
        full length.
    System Response
    Procedure
        Try to localize the problem. If the hierarchy is loaded from an SAP
        source system, you can check whether the extracted data is correct by
    executing transaction RSA3 in the source system. If necessary, check if
    the data is modified with a user exit. If the hierarchy is loaded from a
    file, check the contents of this file. The problem might also be due to
    an error in the transfer rules or in the transformation.
    You can identify the two duplicate nodes from the values for the node ID
    NODEID = [00000194, 00001627 ].
    The problem can be caused by identical nodes delivered more than once
    from the source. It is also possible that incorrect values for
    parameters such as the node name NODENAME or validity period [DATEFROM,
    DATETO] are the cause of the problem.
    First check if the value for node name NODENAME = '10000000950090 ' is
    correct. The node name consists of the characteristic value for the
    hierarchy basic characteristic and the characteristic values of all the
    characteristics compounded to this characteristic. Errors creating the
    node name often result in duplicate nodes. This problem also occurs if
    the node names of all nodes are initial.
    If the structure of the hierarchy is defined as time-dependent, the time
    validity of a node can be restricted with the fields DATEFROM and
    DATETO. Duplicate nodes generally do not occur if the validity intervals
    of two nodes do not overlap in time. In this case check if the fields
    DATEFROM and DATETO are correctly filled.
    In this case the duplicate nodes are not leaves. If you want to reuse an
    existing subtree at another location in the hierarchy, you can refer to
    this subtree with a link node. Possibly one of the two duplicate nodes
    were incorrectly not marked as link nodes.
    please Suggest What to do

  • Report designer error for hierarchial structure on Columns

    Hello,
    I have a query with a structure in rows and another one in columns. I also have a 0COMPANY hierarchy Dimension within the Columns.
    When I insert the data provider into a report designer report, I receive the following error:
    "Query contains a hierarchial structure on Column(s)..."
    Has any one encountered this issue before? Is there a note or workaround available?
    Thank you.
    Sri Yalla

    Hi,
    the report designer need to have a fixed number of columns. If you have a Hierarchical Structure in the Columns, the number of columns can change. Therefore Report designer does not allow to use this DP in this drill down. You should place the Row structure to the columns and the hier-structure to the rows. then it should work.
    best regards,
    kai

  • Error in Transporting the Transfer structure

    Hi can any body tell me . Iam getting this error  while transporting from BW System the transfer structure for 0HR_PY_1_CE.
      1. Transfer structure 0HR_PY_1_CE_LA does not exist.
      2. Error RSAR 440 during after import handling of objects with type(s) ISTS
      3. Errors occurred during post-handling RS_AFTER_IMPORT for ISCS L
    I have  activated the transfer structure  through this programme - program RS_TRANSTRU_ACTIVATE_ALL.

    Check the below notes:
    Note 1009638 - RSAR 440 when you activate transfer rules    applicable for BI7.0 Less than SP12.
    Note 736668 - RSAR 440: Transfer structure & does not exist   Applicable for 3.x system.
    Please check the above Notes and based on your system patch level and issue you need to choose the right one. Second one deals with the Hierarchy.
    Hope this helps..
    Murali