Error in Web application designer in BI7.0

Hi,
If we try to create the template and save, it is showing the following error.
JAVA COMMUNICATION ERROR RFC_DESTINATION IS NOT CONFIGURED.
we tried some RFC connections in the backend . It is showing BI metadata for BSM is outdated. I checked the necessary settings according to note :888687.
But we are able to check the RFC connection between ABAP and portal.
But we are getting the same error. While saving the template which created. it showing the error and i am not able to save the template
Please help in this issue..
thanks in advance.
Regards,
Mohankumar.G

I was working on similar issue for 2 days & I am able to overcome the error mention by you related to WAD now I am able to execute the WAD application through portal.
Send me your mail Id I will fwd u the configuration steps
Meanwhile chk Trans: SM59 for RFC connection
IN Visual Admin check the JCo RFC Provider is properly configured with backend username.
Chk all the JCo related to BI are working properly either with SSO or User mapping
Chk in Table RSPOR_T_PORTAL the portal URL is proper or not
(transaction code SM30).
2. Enter RSPOR_T_PORTAL as the table.
3. Choose Maintain.
4. Choose New Entries to create a new entry.
5. Maintain the connected portal:
RFC destination: <RFC_DESTINATION>
System name: <SYSTEMALIAS>
Default: <DEFAULT>
Portal URL prefix: <PORTAL_URL_PREFIX>, for example, http://<portalserver><domain>:<port>
Prefix of RM for BW Metadata: <KM_RM_METADATA_PREFIX>, for example, /bw_metadata
KM service URL: <blank>
Referesh the MetaData Service in BI Web Application Designer under settings try to connect you SAPRFC.ini file set enviroment variables for the same.
Swapnil

Similar Messages

  • Error in Web Application Designer

    I hope that somebody can help me, we migrated the system BW of version 3.1 to 3.5, but when trying to enter the Web Application Designer throws the following error:
    you are logged on to application server that does not support HTTP  
    thank's

    Hi,
    Goto transaction SMICM and see if the ICM is active: Do you see a Red or Green light here? If Red, then use menu Administration > ICM > Restart > Yes
    Check the services (Shift+F1) and see if HTTP is active.
    Hope this helps...

  • Error run web application designer 3.X

    hello forum,
    When I run the tool designer of the web application version 3.x.
    jumps the following error:
    Run-time error "75"
    Path / file access error.
    I have installed the patch:
    gui710_7-10002995.exe: Patch Level 7 for SAP Logon.
    bi710sp05_500-10004472.exe: BI Add-on 7.x, Support Package 5, Patch Level 5.
    And he still does not work, you know if I need to install any more patch or perform some sort of setup?
    A greeting and thanks.

    Hi,
    You are talking in the query designer?
    But that will only appear the result (with value) red or green or yellow, correct?
    The idea is not to show the value, only the light.
    Example:
    I have the following:
    Client|Value|
    11    | 10eur
    12    | 12eur
    13    | -2eur|
    The idea is to have the following:
    Client|Alert|
    11    |  Green
    12    |  Green
    13    |  Red
    Green to positive, red to negative, but only a light, no values displayed.
    Thanks!
    Edited by: Pedro Taveira on Nov 3, 2011 2:03 PM

  • Run time error in Web Application design

    I have several run time errors whe I deal with big web templates in WAD. Sometimes the error raises when i try to move in html section of the web template (run time error 5: invalid procedure call or argument), some time when i try to open the template (run time error 9: subscript out of range).Did someone have the same problem? I saw a forum specking about librfc.dll file, but i couldn't find many details.
    Thanks.
    Valentina

    hi V.,
    support package level for front end 3.5 ?
    you can check in bex, 'business explorer'->help->about.
    the info version 3500.x.yy; x is the support package level.
    i have tried to use front end 3.5 to access bw 3.0, WAD open like to errors, after patch 7 applied, seems ok.
    you may try with front end 3.0b
    hope this helps.

  • Edit Chart error in web application designer

    Hello,
    Whenever I try to edit a chart in de WAD the edit popup window is empty (no edit fields). Does anyone know how to solve this error. BW is running on WAS 6.20 and I am running SAP GUI 6.40 patch 22.
    Kind regards,
    Raymond Does

    Problem solved!
    My graphics adapter was set to 128% DPI. This caused 2 errors:
    1. The tabs below the template window where "overwritten" by the template window.
    2. The "edit chart" popup window remained blank.
    After setting my graphics adaper to 96 dpi (default) everything worked fine.

  • Bex Web Application Designer issue: portal communication error

    hi experts,
    I am working with Bex Web Application Designer in BI7. we are using SP9. When i try to use the Web template its giving below error.
    The Requested operation could not be performed due to portal communication error.
    its message class is RSBOPLAP and message number is 018 and description is Java System error: An unknown error occured During portal communication.
    when i double click the below error details given.
    Diagnosis
    An error occurred in the BI components on the SAP J2EE Engine.
    System Response
    Procedure
    Contact your system administrator to have the error analyzed in detail.
    Procedure for System Administration
    Start the Visual Administrator, log on to the SAP J2EE Engine and choose "<J2EE_SID>" ->"Server" -> "Services" -> "Log Viewer".
    The file "defaultTrace.trc" includes detailed information about the error that occurred. In Windows, you can find this file in the Log Viewer under "Cluster <computer name>" -> "Server <server number>" -> "<drive>:\usr\sap\<SID>\JC<INSTANCE>\j2ee\cluster\server<NUMBER>\log". ". In Unix, the file is located under "/usr/sap/<SID>/JC<INSTANCE>/j2ee/cluster/server<NUMBER>/log".
    If the file does not include enough detail about the error, you can increase the log level to obtain more information. To do this, choose "<J2EE_SID>" -> "Server" -> "Services" -> "Log Configurator". On the "Locations" tab page, choose "com" -> "sap" -> "ip" -> "bi" -> "webapplications". Using the selection list on the right side of the screen, you can increase the log level, whereby "DEBUG" represents the log level with the most information. You can save your settings by choosing the "Save" icon. The change to the log level is active immediately. Once you have successfully analyzed the error, you should set the log level back to its default value using the appropriate pushbutton; continuous writing to the log file negatively affects the overall performance of the system.
    please give solutions to resolve the issue.
    regards
    vadlamudi

    hi shambhu,
    thanks for the reply, yes its related to basis but they are unable to trace it out. is SP9 support Bex Report Designer and Bex WAD??
    regards
    vadlamudi

  • Chart problems in Web-Application Designer

    Hello,
    I am trying to use CHART in Web Application Designer.
    But whatever TYPE I select in that (pie/stack/..),
    It shows the report with default chart type..
    Then after one /two trials, I have run time error. & Web application Designer crashes. In preview of that chart on template, it shows the chart type I have selected.
    What am I missing in my steps. Or is some library missing..
    Thanks for you suggestion.
    Is very urgent & as I need to show report tomorrow.
    Regards,
    Santosh

    Hi Santosh,
    <b>Defining the Width and Height of the Entire Chart</b>
    in the Properties
    Enter the desired values in fields Width and Height of the window in which you are editing the chart. The entries should be in pixels.
    Choose Apply.
    The size of the entire chart is changed according to your specifications.
    Changing the Size of the Entire Chart with the Mouse
    Point to the border of the preview window with the mouse.
    The cursor becomes a double arrow.
    Click on the border and pull the preview window to the required size.
    The size of the entire chart is changed when you let go of the mouse key.
    Changing the Size of the Plot Area or the Legend with the Mouse
    Click on the element whose size you want to change (plot area or legend).
    The element is enclosed in a move handle.
    Point to one of the move handles with the mouse.
    The cursor becomes a double arrow.
    If the cursor does not become a double arrow, you might not have selected the right element, for example the chart area instead of the plot area. In this case click again on the element whose size you want to change.
    Click on the move handle and keep the mouse key pressed.
    The cursor becomes a cross.
    Pull the element to the desired size.
    The size of the element is changed when you let go of the mouse key.
    Avoid stretching the plot area over the whole area of the chart. The outermost border of the plot area disappears from the visible area in this case and cannot be clicked on again. You cannot change the size of the plot area. If you made the plot area too large by accident, you can undo it with the menu option Undo in the context menu. You can reset the plot area to its original size with Reset, but you will lose all the changes you made to the chart.
    <i><u><b><b><b><b>
    It is simple issue D't worry..And one morething is  Check the <b>Specific Properties</b> of the Template</b></b></b></b></u></i> in Design of the web template.
    Thanks
    Bhima Chandra Sekhar

  • WEB APPLICATION DESIGNER - ERROR

    Hello
    We're getting an error when we try to save an item in BEx Web Application Designer:
    RSBOLAP 018 Java system error: An Unknown Error Occured During Portal Communication
    RSBOLAP 018 Java system error: Excepction in method processFunction
    Has anyone experienced and solved this issue?
    Thanks in advance, kind regards!
    Jon

    Hello,
    Have a look at these Notes
    SAP Note 988484 RC=12 in after import method for objects BTMP and BITM
    SAP Note 916090 RFC-error messages in Web Application Designer 2004s
    Thanks
    Chandran

  • Web Application Designer -Unknown Error Occured during Portal Communication

    we are getting the below error while using the Web Application Designer .
    "Unknown Error Occured during Portal Communication"
    Vesrion
    SAPBW 700 SP14 on ABAP & SP12 on JAVA.
    Found the below error in the default trace
    Error 1
    Exception thrown Fri Aug 15 11:29:15,070:Exception thrown by application running in JCo Server
    java.lang.RuntimeException: Bean RSWR_PREEXECUTION_PROXYnot found on host smy14sap99, ProgId =SMY14SAP99_PORTAL_BD1: Object not found in lookup of RSWR_PREEXECUTION_PROXY.
    Error 2
    Error> occured >Fri Aug 15 11:29:12,413<
    RfcException:
    message: 'ashost' is missing
    Return code: RFC_INVALID_PARAMETER(19)
    error group: 101
    key: RFC_ERROR_PROGRAM

    Hello,
    Have a look at these Notes
    SAP Note 988484 RC=12 in after import method for objects BTMP and BITM
    SAP Note 916090 RFC-error messages in Web Application Designer 2004s
    Thanks
    Chandran

  • RSBOLAP 018  Java system error in BEx Web Application Designer

    Hello,
    while doing inside BEX Web Application Designer "validation of webtemplate" with
    command "validate on server"  I get following error message of WAD  :
    " Message RSBOLAP 018   description : Java system error : an Unknow Error occured during portal communication"
    My procedure till now was ( please see results as screenshots in attachment) :
    a) ckecking prerequisites for "Java template installer'" --> result "prerequisites.jng"
    b) running "Java template installer" ->  " result templateInstaller.jpg"
    c) running Bex Web Application Designer as mentioned above results in error
       message as mentioned above
    d) running Diagnostic & Support Desktop Tool  --> "result Diagnostic support desktop tool.jpg"
    It says that something is wrong with "BI Mastersystem" because of failed connect to
    message server.
    Please advice me what I should do.
    Thanks in advance
    Regards,
    Oscar

    Hello
    It is obvious that the connection between the ABAP and the Java is not working.
    There should be a JCo RFC from the portal side to the ABAP stack set up and an RFC from the ABAP stack to the portal.
    Check the entries of the table RSPOR_T_PORTAL
    The RFC specified here should be the one mentioned above (ABAP - Java)
    Check the name of the system should be SAP_BW
    Is the parameter icm/host_name_full set on the ABAP stack with the domain name ?
    Connect to the BI portal:
    http://FQDN:5NN00/irj/portal
    Navigate to system administration -> system configuration -> system landscape -> expand "portal content" -> systemlandscape -> SAP_BW
    Right click on SAP_BW - Open - Object
    Here you need to maintain these:
    ITS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
    ITS Host Name  - FQDN_OF_BW_ABAP:port - You can use the value of icm/host_name_full parameter and retrieve port number from Tx SMICM - Services
    ITS Path - /sap/bc/gui/sap/its/webgui
    ITS Protocol  - Select http
    Logical System Name  - BW ABAP Logical System Name - Tx SCC4 or BD54
    Logon Method  -SAPLOGONTICKET
    Message server - BW ABAP FQDN
    SAP Client - BW ABAP Client Number
    SAP System ID (SID) - BW ABAP SID
    Server Port - 39NN
    Web AS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
    Web AS Host Name - FQDN_OF_BW_ABAP:port - icm/host_name_full and retrieve port number from Tx SMICM - Services
    Web AS Path - /sap/bw/BEx
    If everything is set properly then do a test connection.
    Good Luck
    RB

  • BEX Web application Designer displaying Java Communication Error

    Hi,
    When we are using the BEX Web application Designer to create new web template, it throws error saying "Java Communication Error: An UnKnown Error Occured During Portal Communication."
    ====================================================
    Diagnosis
    An error occurred during communication with the BI components on the SAP J2EE Engine.
    System Response
    Procedure
    Contact your system administrator to have the error analyzed in detail.
    ====================================================
    Kindly help to resolve this issue.
    Regards, Krish

    Hi,
    Please check below document for connection between BI and Portal
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/d082fe32-5037-2b10-3288-fd009f695c74
    You might be doing something wrong in any of these steps.
    Regards,
    Kams

  • BEx Web Application Designer Execution Errors

    Hi there,
    When I execute report via BEx Web Application Designer, the error message is shown as 
         The metadata of "ITE" "CHART_ITEM" are incorrect for parameter "LEGEND_POSITION"
         The metadata of "ITE" "CHART_ITEM" are incorrect for parameter "LEGEND_POSITION"
    I can not get the review form.
    Did anyone meet this problem? How to resolve it?
    Thanks in advance
    Edited by: Jonas Sun on Oct 2, 2008 12:40 PM
    Edited by: Jonas Sun on Oct 2, 2008 12:41 PM

    Hi
    In the XHTML code for the web template check the value being assigned to LEGEND_POSITION . If its some worng value assigned then please chnage it and execute the web template.

  • Bex Web application designer error

    Hi experts,
    I am getting an error when selecting F4 for FROM and TO in FIscalyear/period in WAD report
    FisaclYear/period->F4
    Then I go to Slect values for FiscalYear/period where I have
    FROM ->F4 and
    TO->F4
    On clicking F4 for FROM and TO value ranges I am getting this error.
    Please sugggest how to solve this error.
    500 Internal Server Error
    BEx Web Application
    Failed to process request; contact your system administrator
    Information for Administrator
    To avoid this exception see the steps below. To help SAP better investigate this issue, you will need to provide the diagnostic information from these steps.
    1. Most likely, the issue you are experiencing has already been corrected. Please make sure that the most recent patch level is deployed on your system according to notes 1033246 and 1011241. Starting with Support Package Stack 16 patch level 30, BI Java is delivered according to the synchronized delivery process described in the note 1033246.
    2. Please ensure that NetWeaver Business Intelligence Diagnostics & Support Desktop Tool does not report any issues on your server according to note 937697. You can start it by clicking here (administrator permissions are required).
    3. When opening any customer message on this issue, please attach:
    Support Desktop Tool support info ZIP file according to note 937697,
    Required information for reproduction according to note 948490.
    Error Summary
    Exception occured while processing the current request; this exception cannot be handled by the application or framework
    If the information on this page does not help you locate and correct the cause of the problem, contact your system administrator
    To facilitate analysis of the problem, keep a copy of this error page Hint: Most Web browsers allow you to select all content, and copy and paste it into an empty document (such as in an email or simple text file)
    Root Cause
    The initial exception that caused the request to fail was:
    Invalid program status: Duplicate member created: 0FISCPER3: 2009001, Sids: 182009001 & 92009001
    com.sap.ip.bi.bics.exceptions.BicsProgrammErrorException
    at com.sap.ip.bi.bics.dataaccess.resource.impl.bi.selector.ProviderInfoObject.addMember(ProviderInfoObject.java:308)
    at com.sap.ip.bi.bics.dataaccess.resource.impl.bi.selector.ProviderAttribute.addMember(ProviderAttribute.java:120)
    at com.sap.ip.bi.bics.dataaccess.resource.impl.bi.selector.ProviderInfoObject.retrievePresentations(ProviderInfoObject.java:804)
    at com.sap.ip.bi.bics.dataaccess.resource.impl.bi.selector.ProviderInfoObjectMember.getValue(ProviderInfoObjectMember.java:64)
    at com.sap.ip.bi.bics.dataaccess.consumer.impl.selector.InfoObjectMember.getBaseValue(InfoObjectMember.java:89)
    Edited by: hema.t on Nov 15, 2011 10:35 AM

    hello, i have similar problem.
    I've created simple Web template, which shows text "test template", but when i try to open it from the portal I get the error:
    ""500 Internal Server Error
      BEx Web Application
    Failed to process request; contact your system administrator
    Error Summary
    Exception occured while processing the current request; this exception cannot be handled by the application or framework
    If the information on this page does not help you locate and correct the cause of the problem, contact your system administrator
    To facilitate analysis of the problem, keep a copy of this error page Hint: Most Web browsers allow you to select all content, and copy and paste it into an empty document (such as in an email or simple text file)
    Root Cause
    The initial exception that caused the request to fail was:
    Error: Internal error. No esid found.
    Log ID 984BE15B700A006C0000029000000E880004BAA5DE640345
    Does someone know how to solve this problem?

  • To use Web Application Designer release 2004s do we need to have portals???

    Hi
    I would like some clarity regarding whther we need a portal or not.
    If you use Web Application Designer (SAP BW 3.x) it works fine, you can create reports and then it shows in SAP Easy Access under favourites. Executes fine, no portal is used.
    Now when I want to use the new Web Application Designer I can not execute the reports. Gives me error
    "Java communication error: RFC destination NOT_CONFIGURED does not exist", the window it appears in has a text saying it can't conect to the portal. Then notes that I look at regarding this seems that the connection between SAP BW and Portal must be set up.
    So can please someone tell me whether you need the portal to use the new Web Application Designer release 2004s
    Thanks in advance

    YOu neeed BI Java configured
    If you do not use any new BEx Web functions, do you have to install the usage types BI Java and EP?
    answer -SAP EP 6.0 Portals could be integrated into a federated portal system landscape using URL iViews.
    For more insights - FAQ
    Pls read carefuly should answer all your current and future questions.
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/webcontent/uuid/43008b6a-0901-0010-90af-c848d878bac3?rid=/library/uuid/a5067965-0901-0010-6f8a-bbf0b7424283
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/webcontent/uuid/43008b6a-0901-0010-90af-c848d878bac3?rid=/library/uuid/cea68c65-0901-0010-f5a4-fd34189d8078
    Hope it Helps
    Chetan
    @CP..

  • Unable to open WAD (web application designer) in BW 3.5!

    Hi,
    when i open WAD through menu path (start->programs       
    ->Business explorer->Web application designer), i am getting the following error!
    WADConst
    Please log on to a Netweaver BI 7.x system. System J2E does not have the minimum version required 70005.
    I just can`t understand from where i got this BI 7.x system, when my system is BW 3.5 (NW04 platform).
    can any one expalin me what is this problem? and suggest me to over come this problem?
    Thanks,
    Ravi

    Hi Ravi!
    I assume that you installed the SAP GUI 6.40 with BI Addin (which contains the BI Frontend for SAP NetWeaver 2004s BI).
    In this case, you have a sub folder underneath "Business Explorer" in your startmenu named "Business Explorer (SAP BW 3.x)".
    You have to use this version of the BEx Web Application Designer.
    If this is not the case, please create a Support Message with all detailed information (backend and frontend versions).
    Thank you,
       Tobias