Error Replicating DataSource to BW .....Urgent
Hi All,
During replication of DataSource from our CRM to BW we selected <b>Replicate as DataSource</b> somewhere and all the datasources except Hierarchies are save as DataSources and <b>not as DataDource 3.x</b>. Can someone tell me how to change all DS to DS 3.x, there are more then 600 of these so individually its impossible for us to do.
Thanks & Regards,
Vikas Sharma
Hi Vikas,
try:
( see chetan's reply).
/message/1870535#1870535 [original link is broken]
assign points if useful ***
Thanks,
Raj
Similar Messages
-
Hi All,
a job in a process chain was failed with this error message:
DataSource ZPRODUCT_STATUS_TEXT has to be replicated (time stamp, see long text) R3 16
our R/3 system it was upgraded one week ago for the ECC6 version and our BW version is still 3.0b, i don't know if because the upgrade processus i get this error and i have to do something in the BW system...
thanks for your help
BilalHI,
i tried to do what you said, from infosource: replicate datasources and after se38 and i have choice in the box the name of infosource and after execute
but i have get like a message: problem class important
message text: No transfer structure selected
Message Text
No Transfer Strcuture Selected....with this info
Technical data
Message type__________ I (Information)
Message class_________ RSAR (Data transfer and meta data maintenance)
Message number________ 051
Message variable 1____ No Transfer Strcuture Selected
Message variable 2____
Message variable 3____
Message variable 4____
Message attributes
Level of detail_______ 1 (Level of detail 1)
Problem class_________ 2 (important)
Sort criterion________
Number________________ 1
i have tried to load again but the same problem...any body have a plus info....
Thanks
Bilal -
What will Happen in R3 side while Replicating Datasource
Hi Friends,
what will happen in R3 side and BW side while replicating datasource in BW side
Thanks & Regards,
GowriHi Gowri,
Replication needs to be done only when you change the extract structure which in turn would change your datasource. The simplest way to know when replication needs to be done is each time you save you datasource in R/3. This causes the timestamp of the datasource to be changed and hence the timestamp of the datasource in R/3 and BW are not in sync. Replication would make the timestamp in sync in both R/3 and BW.
Hence you would notice the error "Timestamp error" when you do not replicate the datasource after changing it.
Also check this link:
Re: time stamp
Bye
Dinesh -
Error in Datasource 0FI_AP_51 in RSA3
Hello All,
I am Executing DataSource 0FI_AP_51 in RSA3, Getting message like Error in Datasource, I checked in Rsa2 there is no any error or warning, Kindly suggest
Thanks
ShaliniHi Shalini,
Is your issue resolved. I am facing the same issue. Please let me know the soultion.
Experts,
When I am trying to execute 0FI_AP_51 in RSA3, its popping up an information 'Errors occurred during the extraction'. Any solution for this?
thanks
AP -
ERROR: replicator: Job Failed :error retrieving site manifest exception
Hi all,
I have installed the Site Studio Publishing utility on content Server machine.
I have installed the site studio publishing client on my machine and I have configured successfully. I mean to say that I have configured the destination on Publishing Utility & Content Provider on Publishing Client.
I have created the publishing job on the the site. I could see the content delivered on my machine from the content server, successfully. Now i have updated the site in the Site designer. I have just added "Hi" in the site layout page in the site designer. I have saved it. Now I have given the publishing job again. While running the job, I am getting following Error:
WARNING: replicator: 401 response received from server
[Sep 13 18:11:49] ERROR: replicator: Job Failed :error retrieving site manifest exception:
com.kinecta.net.HttpIOException: HTTP 401 error received from server :http://10.16.21.124/idc/idcplg?IdcService=SS_GET_SITE_PUBLISH_REPORT&siteId=TestSite
at com.kinecta.replicator.SiteCrawler.openConnection(SiteCrawler.java:515)
at com.kinecta.replicator.SiteCrawler.openConnection(SiteCrawler.java:191)
at SiCloneSyndicator.SiCloneSiteStudioPackageGenerator.getSiteManifest(SiCloneSiteStudioPackageGenerator.java:452)
at SiCloneSyndicator.SiCloneSiteStudioPackageGenerator.onReplicationStart(SiCloneSiteStudioPackageGenerator.java:342)
at SiClone.SiCloneSiteReplicator.run(SiCloneSiteReplicator.java:534)
at SiClone.SiCloneIcePackageGenerator.run(SiCloneIcePackageGenerator.java:39)
at SiClone.SiCloneSiteReplicatorRunner.runJob(SiCloneSiteReplicatorRunner.java:308)
at SiClone.SiCloneSiteReplicatorRunner.run(SiCloneSiteReplicatorRunner.java:178)
at SiCloneSyndicator.SiCloneGenerator.doUpdate(SiCloneGenerator.java:516)
at SiCloneSyndicator.SiCloneGenerator$1.run(SiCloneGenerator.java:472)
First of all, May i ask you a question: What is the site manifest file?
Any help would be much appriciated.
Regards & thanks,
Nirmala Vijaya Sekhar varreHi Sreenath,
I am getting following error while publishing the microsite using Site Studio Publisher even I unchecked "Treat home page errors as critical" and "Treat manifest errors as critical" options, here is the log:
INFO 2012-02-14 07:35:11,794 - ----- Running Job
INFO 2012-02-14 07:35:11,794 - Output Path : /opt/ora/ucmdev/Middleware/domains/UCMDevDomain/ucm/cs/data/SiteStudioPublisher/output/MyBiopsy
INFO 2012-02-14 07:35:11,794 - Authentication : BasicAuth
INFO 2012-02-14 07:35:11,794 - Use Cache Control : false
INFO 2012-02-14 07:35:11,794 - Publish Now : false
INFO 2012-02-14 07:35:11,794 - Force Analyze : false
INFO 2012-02-14 07:35:11,794 - Force Download : false
INFO 2012-02-14 07:35:11,794 - Use LastModified : true
INFO 2012-02-14 07:35:11,794 - Use SSPETag : true
INFO 2012-02-14 07:35:11,794 - Treat home page errors as critical : true
INFO 2012-02-14 07:35:11,794 - Treat manifest errors as critical : true
INFO 2012-02-14 07:35:11,794 - Soft Error Threshold : 99
INFO 2012-02-14 07:35:11,794 - Soft Error Codes : 403,404
INFO 2012-02-14 07:35:11,794 - Hard Error Threshold : 99
INFO 2012-02-14 07:35:11,794 - Hard Error Codes : 501,502
INFO 2012-02-14 07:35:11,794 - Delete Threshold : -1
INFO 2012-02-14 07:35:11,794 - Friendly Url Parameters :
INFO 2012-02-14 07:35:11,794 - Dynamic Url Parameters :
INFO 2012-02-14 07:35:11,794 - Default Filename : index.html
INFO 2012-02-14 07:35:11,794 - Page Extension : html
INFO 2012-02-14 07:35:11,795 - ----- Connecting: http://dappucm07.cap.org:16200/cs/idcplg?IdcService=SS_GET_PAGE&siteId=MyBiopsy
INFO 2012-02-14 07:35:11,802 - Response: 301 Moved Permanently
INFO 2012-02-14 07:35:11,802 - http redirect found:http://dappucm07.cap.org:16200/MyBiopsy/index.html
FATAL 2012-02-14 07:35:11,840 - sitestudiopublisher.net.IOFailureException: error retrieving site manifest
INFO 2012-02-14 07:35:11,840 - Error threshold exceeded
INFO 2012-02-14 07:35:11,840 - Finishing...
INFO 2012-02-14 07:35:11,840 - ----- Job Summary
INFO 2012-02-14 07:35:11,840 - Source URL : http://dappucm07.cap.org:16200
INFO 2012-02-14 07:35:11,840 - Start time : Tue Feb 14 07:35:11 CST 2012
INFO 2012-02-14 07:35:11,840 - End time : Tue Feb 14 07:35:11 CST 2012
INFO 2012-02-14 07:35:11,840 - Duration : 0 hours 0 minutes 0 seconds 46 milliseconds
INFO 2012-02-14 07:35:11,840 - Connect Time : 0:00:00.046
INFO 2012-02-14 07:35:11,840 - ----- Links Summary
INFO 2012-02-14 07:35:11,840 - Total : 0
INFO 2012-02-14 07:35:11,840 - Modified : 0
INFO 2012-02-14 07:35:11,840 - Added : 0
INFO 2012-02-14 07:35:11,840 - Deleted : 0
INFO 2012-02-14 07:35:11,840 - Examined : 0
INFO 2012-02-14 07:35:11,840 - Redirected : 0
INFO 2012-02-14 07:35:11,840 - Downloaded : 0
INFO 2012-02-14 07:35:11,840 - Not Found : 0
INFO 2012-02-14 07:35:11,840 - ----- Job Failed
INFO 2012-02-14 07:35:11,840 - -
i can't download the apple ios 5 for the ipad. after downloading around 10 % an error no. 3259 occurs. it's a network error. please help . it's urgent. i am having apple ipad 2 3G wifi.
i switched off all the security settings and all the firewalls.
i m unable to install any of the app on the ipad
so i saw the apple support and it said to update the older version of my ipad.
and niether am i able to download the update nor am i able to download any app and install it in my ipad2
i also tried to download an .ipsw file (ios5 update) from torrentz bt i am also unable to install from that as itunes rjects that file and gives an error. and also tries to delete that file. plz anyone help urgently. -
I recently found out that crawler suddenly stopped working. so I went ahead and restarted subscriber, syndicator and the content server and found out the database password has expired so I reset the password and updated the connection string accordingly to start the content server now I'm getting the following errors when I run the crawler. Any idea? The permission on both idcplg and idcplg.kold are ( -rw-r--r-- 1 stellent wcms 226689 Feb 18 14:51 index.html )
ERROR
[Feb 18 16:46:49] INFO: replicator: opened connection http://editinsideolgc/wcms
/idcplg?IdcService=CAL_JAVASCRIPT_SERVICE_EX in 0:00:00.022
[Feb 18 16:46:49] INFO: replicator: analyzing : http://editinsideolgc/wcms/idcpl
g?IdcService=CAL_JAVASCRIPT_SERVICE_EX
[Feb 18 16:46:49] ERROR: replicator: Could not move /app_vendor/stellent/sspu/of
fers/89718/wcms/idcplg to /app_vendor/stellent/sspu/offers/89718/wcms/idcplg.kol
d
[Feb 18 16:46:49] ERROR: replicator: ContentSink reported failure to add item.
[Feb 18 16:46:50] ERROR: replicator: crawl failed
[Feb 18 16:51:38] INFO: ice: request: ice-get-status, request-id: 60014998233198
39930, response: ice-code, uuid: ffb73892-0102-0008-80c4-00096B4E3594, package-i
d: null, subscription-id: null, state: null, ice-code: 200 kinecta-code: -1
______________________________________________Hi we are having the same problem and are wondering how you were able to resolve this problem. Thanks in advance, joe
-
Replicated datasources transportation
i have created TR for all the datasources (3 generic and 1std(3.5)) in ecc DEV.I ahve also created TR for replicated datasources for the above in BWDev.
so, once the ECC DEV to ECCQA moves , DO I NEED TO REPLICATE THE DATA SOURCES AS I HAVE GOT REPLICATED DATAOUSRCES IN BWD ev?
2. what would happen if i manually replicate the datas soruces in BWQA, then transport replicated datasources from BWD evto BWQA
3. if i need not activate manually the datasoruce in ECCQA, then i should wait for the replicated datasources to reach BWQA, and then only transport other request?
4. how to transport ONLY PSA? what are the necessary steps to be taken?Hello,
There is no harm in replicating the datasource in BI QA box...once you replicate them to get them activated you can send the transport request...
ARE u saying that after manually replicating in BIQA, the replicated datasources request from BIDEV to BIQA would activate the dataosources in BIQA?
Even if you dont replicate and send the replicated request it will do.
What i understand is that i can simply transport the ECC request to ECCQA , then just transport the replicated datasources from BIDEV t BIQA for replicating the datasources and then after this all the other BI requests should be imported?
my concern is that if i manually replicate the datasources in BIQ, then start importing all the BI request and i ahve got first 3 replicated datasources followed by other requests. so ,after the manual activation, once these replicated datasources moves, should i wait for reactivation of all the datasources and only then transport request of the transports? -
Urgent!!Error While replicating Datasources!!
Hi BW experts!
Could any help me how to resolve the the datasource replications error if it exceed length the field name & data length of the field..??
<b>Error: Fieldlength too long for PSA fields
Error Field QUEST_RATINGFACTOR ( Position 24 ): Field name is longer than 16 characters</b>
Thnx in advanceHi,
Are you working on SRM as source, if the name length is more than 16 characters it is not required....you can reduce the characters in the backend SRM and again reload.
For invalid character you can go to RSMO and get into details tab to find out the actual invalid character. Sometimes small cap and capital can reasult in this issue.
Thanks
Abhi -
Error while Replicating Datasource from R/3
In R/3 extraction, after activating the datasource in R/3 and replicating the datasource in BI, I received an error saying that 'SQL error occured when accessing a table' with Message no. RSAR051... Help me in this.
I checked in ST22. But there is no problem in it. Pls give me the solution..
-
Hi All
We have BI system connected to R/3 system. Now our Qual R/3 system is upgraded from 4.6c to ECC 6.0. Now the BASIS is trying to connect Qual R3 and Qual BI system. When we rt. click on source system in RSA1, it says at the end: datasource cant be saved to the datasource : 3.x 0material_attr. whats this mean ? It says with the same name, RSDS datasource exists.
What steps we have to do immdly when a R/3 system is upgraded ?
1) do we have to do something in R3 also with the DSs ?
2) If the replication on Rt. click on Source system fails with the above error, what should i do ?
can i manually replicate that datasource in RSDS ? I dont see that DS too in my BI. So why it says to be replicated ? Should i restore it as 3.x or RSDS ds ?
Thanks
venkatHi,
There may be some data sources missing after R/3 upgrade to ECC6.
Search OSS notes for the same.
See Note: 735646 for missing FI Data Sources.
Cheers
Praveen -
OATS: Error Creating datasource client connection
Hi All
When i try to add montiors in the OATS controller machine i am getting the following error .
Error while creating datasource client connection.
i am trying to monitor a linux machine. I am able to ping that machine from controller.
when i tried to do
plink.exe username@hostname i am getting the following error ...
FATAL error : Network error : Connection timed out..
Can anyone please help me on this??
ThanksI'm not sure if this is the same problem but the following thread may help (mentioning the ports that may need opening on your firewalls)...
Re: What are the various ports used by OLT?
oracle.port.rmi=4444
oracle.port.http=8088
oracle.port.empstart=9001
oracle.port.uil2=7071
oracle.port.dataCollector=7073
oracle.port.webservice=8083
oracle.port.jndi.rmi=1098
oracle.port.jndi=1099
oracle.port.https=8433
* 9001 (Agent Comunication Port)
* 1099 (Datacollector Comunication Port)
* 8088 (for running OpenScript scripts) -
Create Request Error in BI 7.0 - URGENT
Hi Team,
I'm collecting the objects for the cube using the data flow before and collect automatically mode.
When I create a request I'm getting the below error message.
Error MEssage
Changes cannot be made, display user only
Object IOBJ ZAPSAFETY couldn't be saved to order
Object IOBJ ZAPSAFTY couldn't be save to order
Pl advise it very URGENT need to move the object to Test Box for UAT.
We have upgarde the system from 3.x to BI 7.0 and this is the first request i'm creating in BI 7.0.
Regards,
SenthilHi,
I'm having trouble with my infosource.
I've created a separate request for the info source but the problem is couldn't find the separate objects there. after that planning to create separate request for cube.
will it work ?? pl advise. Thanks.
Regards,
Senthil -
Impdp error while attaching the job - Urgent - Prod batches are stopped
I am getting following error, when I invoke the following command.
impdp "'/ as sysdba'" attach ="SYS"."SYS_IMPORT_TABLE_01"
Connected to: Oracle Database 10g Enterprise Edition Release 10.2.0.2.0 - 64bit Production
With the Partitioning, OLAP and Data Mining options
ORA-39006: internal error
ORA-39065: unexpected master process exception in DISPATCH
ORA-44003: invalid SQL name
ORA-39097: Data Pump job encountered unexpected error -44003
The actual import job was stopped with stop_job in impdp> prompt.
DB Version: 10.2.0.2.
Please throw some lights to fix this issue. Production batches are already on hold. It is very urgent.I can't remember the number of the bug sorry, but i haven't the same issue and I had to update to 10.2.0.3.0 (I opened a SR before in my previous company when i worked)
-
Error while extraction from R3 : URGENT
While extracting from R/3 generic datasource(extracted through function module ) i am getting error as :
<b>Error message from the source system
Diagnosis
An error occurred in the source system.
System response
Caller 09 contains an error message.
Further analysis:
The error occurred in Extractor .
Refer to the error message.
Procedure
How you remove the error depends on the error message.
Note
If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the</b>
<u>But when I am running the FM or the extractor checker it is giving actual records with our any error</u>
Could you please help me what to do ?
No job log in job overview , only it is given <b>Cancelled</b>.Some possibilities:
1. Replicate the data source and then try loading.
2. Check the RFC connection ; may be it is broken.
3. Check the update rules to see it is active.
Ravi Thothadri
Maybe you are looking for
-
My external hard drive will not mount with my mac?
Okay so everything was working out great till the new OS came out. Then i ran into some problems. I can no longer back up anything i have on my laptop anymore because my external will not pick up in finder-desktop-etc. I need help as fast as i can be
-
I am having trouble connecting IPAD1 to wireless any suggestions?
I am having trouble connecting my IPad1 to Belkin Wireless Router. It was working fine until a couple of days ago. I can use my IMAC okay via wireless. I can see my network on the IPad, but message comes up "unable to join the network XXXX". I have r
-
How do I get MIDI to work with individual plug-ins?
I'm using Logic Studio/Pro 8.02. I have Guitar Rig 4 loaded as an AUi, mono audio input, stereo output & MIDI on Channel 16. I'm using a Behringer FCB1010 as my MIDI controller. I can't seem to figure out how to (of if I can) get the FCB to control t
-
Behaviour of default value of METHOD_OPT
Hello, I was trying to test the impact of extended statistics feature of 11g when I was puzzled by another observation. I created a table (from ALL_OBJECTS view). The data in this table was such that it had lots of rows where OWNER = 'PUBLIC' and lot
-
Premiere CC audio crackle and non-playback
Has anyone else seen in 7.2.1 and 7.2.0 when scrubbing or stopping and starting, the audio will either crackle or just not playback at all? It's not consistent but fairly easy for us to recreate. We're playing out of a Mac Pro (early 2012) 40Gb of