Error:      Restrict variable to single value

Hi experts,
for key figure planning, I created a planning profile group, which contains 3 planning profiles. But when choosing the Planing Profile Group, I get the error message as follows:
Error:      Restrict variable 4MKTHI01 () (area 4CRM0001 (CRM Marketing Plan Values)) to single value
How can I fix the error? I appreciate any kind of help!
Thanks in advance,
Thorsten

Hello Ravi,
I really appreciate that you try to help me - but can you please be explain more in detail what to do?
What I did - and what did not work out:
In TX BPS0, I doubleclicked on Planning Area 4CRM0001, I clicked on the tab "Variables" and I doubleclicked on the relevant variable 4MKTHI01 of the Type Hierarchy. By doing so, I get the message "Hierarchy CRMMKTROOT does not exist". I also do not have the possibility to edit the variable by right-clicking; also the edit button is disabled.
Like described above: When I click on "Set Variables" and chose the variable, I am also not able to do any settings. So how?
Thanks,
Thorsten

Similar Messages

  • Variable multiple single value filled with customer exit used in FOX form.

    Hi guys, I definitly need your help in the following scenario:
    I have variable (multiple single value) filled in a customer exit and use it in web template. There it is used in the drop down box for selecting a special date in the analysis item. And there comes the first question:Why the results from the customer exit are written in the way "date1; date2; date3" in one line? They should appear line by line in rows. How can I influence that? I tried both data binding types, "variable" and "characteristic".
    Now a button raises a planning function with a fox formula which should write the selected date (from the drop down box) in a customer table using "call function".
    I always get the error, that I need to restrict the variable to "single value". Why do I have to do that and if necessary how can I do that? Other planning functions without the fox formula also work properly with using the selection from the drop down box.
    I appreciate you help.
    Kind regards, Anja.

    Hi Vamsi.,
    Try this code.
    WHEN 'PREVIOUS_YEAR_1'.
    IF I_STEP = 2. "after the popup of user entry
    LOOP AT I_T_VAR_RANGE INTO LOC_VAR_RANGE
    WHERE VNAM = 'ZCURRENT_YEAR_PERIOD'.
    break-point.
    IF SY-SUBRC EQ 0.
    WA_YEAR = LOC_VAR_RANGE-LOW+0(4). "Year
    WA_MONTH = LOC_VAR_RANGE-LOW+5(3). "Period
    WA_YEAR = WA_YEAR - 1.
    CONCATENATE WA_YEAR wa_month INTO WA_FISC_PERD .
    CONCATENATE WA_YEAR WA_MONTH1 INTO L_S_RANGE-HIGH .
    L_S_RANGE-SIGN = 'I'.
    L_S_RANGE-OPT = 'EQ'.
    APPEND L_S_RANGE TO E_T_RANGE.
    ENDIF.
    L_S_RANGE-SIGN = 'I'.
    L_S_RANGE-OPT = 'BT'.
    APPEND L_S_RANGE TO E_T_RANGE.
    ENDIF.
    ENDIF.
    ENDLOOP.
    endif.
    Assing points if it helps you.
    -- Selva

  • Creation of Variable with single values in BPS

    Dear All,
    I have a very basic requirement in creating variables that would accept single values from the user in BPS.
    Could anyone pls provide me the steps in doing so?
    I am able to create and use varibles with value ranges but could not find the option to create variables with  single values.
    Regards,
    Srini.

    Hi Raj,
    I have already been  thru SAP help file but,  though it says we can create variables with single values, it does not  provide any steps in creating it.
    Any suggestions?
    Regards,
    Srinivas Kamireddy.
    Edited by: Srinivas Kamireddy on Apr 25, 2008 7:59 PM

  • Error : Attribute pwdaccountlockedtime is single valued users try pwdchange

    Hi,
    I am using OID 90220 and the OS is Solaris 9. When the users try to change their passowrds from the application they are receiving an error : Attribute pwdaccountlockedtime is single valued. When I try to modify the password from OID as orcladmin it gives me :
    Attribute or value already exists.
    I have set password lockout if the users tries wrong password thrice and he cannot use the old password until the next 20 times and the password lockout duration to be 1 day.
    Any clue what the error is all about?? In the OID admin dco I have seen "pwdaccountlockedtime" is not be changed and I have never changed it.
    Any body if you can please help.
    Regards,
    Ramana

    Use "Create Like" to create a duplicate account with a new DN. Delete the original account. Use "Create Like" to create a new account the original DN from the duplicate. The new account should now work. Delete the duplicate.

  • Subject: BW Query Variable – Multiple Single Values

    I have set a characteristic variable on process chain id. In General tab, Variable is u201Cprocess by manual inputu201D.
    In Details tab, I set:
    Variable represents Multiple Single Values, Variable is ready for Input
    When I run my query, I can select multiple process chain ids. Problem is query returns process chain information for only one value (first value entered for process chain id in multiple selections. I have verified process chain information exists for all the multiple values.
    Appreciate any feedback.

    Thanks, I do not find any other restrictions. If I simply remove the variable which lets me spacify multiple single values, I see
    all the process chains. When I  add this variable to query under retsriction and run the query, I see pop-up and I can enter multiple values, but only first one is being searched. There is probably some setting in variable definition somewhere that it only processes first value.
    Is there a way in RSRT to show me entire ABAP code of the query. 
    I ran RSRT set some break points but it is kind hard to troubleshoot. If I had the entire code, I can try to understand what is being done.

  • SAP Web-BEx: Variable "Multiple single values" and Excludes

    Dear experts,
    I got a "ultiple single values"variable and use excludes to avoid cetrain data to be shown. Sofar thats all workin quite well.
    But.. if I want to use this variable during navigation,  the variable values are not shown.. why is that?
    It seems the system does not know how to handle the exclude combined with the variable value.
    Does anyone have a solution for this?
    Thanks
    Oliver

    Hi,
    In BEx Web, it makes a big difference: with multiple values you can only fill a list of different values.
    WIth selection option, you can do basically what you want (as the typical GUI selection screen in the Excel BEx): enter a single and an interval including or excluding values, use the LIKE (contains pattern, *) etc....
    hope this shed light
    Olivier.

  • IP: Exit-variable multiple single values

    Hello,
    I have a question to Exit-Variables in IP. I'd like to fill an Exit-variable with several single values, e.g. A, D, G. At the moment I could transfer only one single value, e.g. A, with following coding:
      l_example TYPE CHAR VALUE 'A'.
      l_s_range-low = l_example.
      l_s_range-sign = 'I'.
      l_s_range-opt  = 'EQ'.
      APPEND l_s_range TO p_t_range.
    How could I change the coding for transferring several single values?
    Many thanks for your help.
    Friedrich

    Hi,
      take whatever values you want to populate into one internal table l_example. Then loop over this internal table.
    Loop at l_example into wa_example.
    l_s_range-low = wa_example-value.
    l_s_seqno = sy-tabix.
    l_s_range-sign = 'I'.
    l_s_range-opt = 'EQ'.
    insert l_s_range INTO TABLE p_t_range.
    clear wa_example.
    Endloop.
    Hope this works.
    Regards,
    Bindu

  • How can we Restict the Char single value Variables with , , =

    Hi Experts,
    How can we Restict the Char value Variables with <, >, <=  (without selecting Inverval or only passing single value)
    For Example
    We have a standard Query 0FIAR_C03_Q1005, in this
    New Selection
    "1 - 15 Days, Posting Date<=Key Date, Clearing Date>Key Date"
    This is restricted  with the
    Clearing(0CLEAR_DATE)
    <Clearing key date(0P_KEYD3)  It is a single value SAP Exit Varible
    PostingDate(0PSTNG_DATE)
      <= Posting keydate(0P_KEYD3)  It is a single value SAP Exit Varible
    When seeing these 0P_KEYD3, 0P_KEYD3 variables in the New selection screen they looks like  >0P_KEYD3, <=0PSTNG_DATE
    if you define any custom variables these are looks like =ZV_DATE.
    to enable < , >, <= symbols for variables what we need to do.
    In other way
    Say we created one variable ZV_DATE single value, processing type as customer exit.
    for this we populated current day,
    Now Requirement is we need to display the all the records which are <= current date,
    instead of passing low and high values, i want to restrict the calday <=ZV_DATE
    New selection
    0calday
      <=ZV_DATE
    How can we achive this, this is how the business content report having the restrictions
    Please sugget me.
    Thanks
    Chandra
    Edited by: Chandra Gandla on Jun 18, 2010 11:01 AM
    Edited by: Chandra Gandla on Jun 18, 2010 11:01 AM

    Ok,
    In the InfoObject 0calday in the query designer under the filter area, under characteristic restrictions right-click over that InfoObject (0calday).
    In the next window (select Values for [0CALDAY]  Calendar Day in the dropdown box for "Show" choose Value Ranges. Under the word "Between"  dropdown box select "Less than or equal to"
    Below that word click on the button of the dropdown box Select from list.
    In the new window select instead of History Variables and double-click on your variable ZV_DATE.
    Click on the right blue arrow to move it to the right.
    And there you go.
    Tip: It exists a SAP standard variable named 0DAT which is exactly the current date (don't need to use ZV_DATE variable).
    Diogo.

  • BPS: Possible to limit a variable to a single value?

    Hello,
    I have a BPS variable which is available in the planning folders so the user can change the value himself.
    For a planning layout, one and only one value is required, as the system otherwise wouldn't know which value to use when saving data. It is possible though for the user to select both a mix of values and ranges. I see the lowest value is always used. Consequently this is not technically a problem.
    I would like to limit the variable to a single value only, in order to not confuse the users. Is this possible?
    Best regards,
    Christoffer Owe

    Hi,
    The following link tells you about the variable type ;
    http://help.sap.com/saphelp_nw70/helpdata/EN/ac/789b3c4d4d8d15e10000000a114084/content.htm
    http://help.sap.com/saphelp_nw70/helpdata/EN/22/1e9b3c334d8c15e10000000a114084/content.htm
    1. create variables with single values
    2.while creating variable tick the setting 'Restriction of values required by user'
    I think that will suffice your requirement .
    Thanks
    Pratyush

  • Crystal Reports prompt single value variable from BEX

    Hi,
    after upgrade to BO 4.1 SP2 Patch 3 the prompt from BEX variable in CR doesn't work.
    After investigation the issue is happened for variables containing more than 9 values.
    Bex Setting: Variable -> Details -> Variable Represents -> Single value
    Variable which shows Jan-Dec
    The issue happens only on CR file stored in BO server in Cr design time it works fine.
    Is the bug known? Is there any solution?
    Harald

    Yep.
    Now tell me how you want to show that Prompt @ WebI report level.
    My problem is that in WebI selection screen we get list of date values from the info provider instead of Calendar prompt
    where user can enter the values directly. Exactly, i didn't get this??
    @Prompt:
    You have flexibility to show options like:
    Mono/Multi: User can select Single value or Multiple.
    BW Variable: Same we have (Single/Multiple)
    Free/Constrained: User can Enter his/her value directly or No change option.
    BW Variable: By defalut you will get this, once you made it to Optional input.
    Persistent/Not_Persistent: Refreshed report has to show last selected value means use Persistent otherwise Not_P.
    By seeing the Prompt syntax , I can say your Variable is after Customer Exit, Correct??
    Workaround for your Problem is:
    <FILTER KEY="ZV_DATE"><CONDITION OPERATORCONDITION="Equal"><CONSTANT TECH_NAME="@Prompt('Date (Previous Day)','A','Date\LovDate (Previous Day)Base',mono,primary_key)"/></CONDITION></FILTER>
    You have to remove that Date class and objects from prompt syntax. Because of that it showing up LOV's not calendar.
    Like:
    <FILTER KEY="ZV_DATE"><CONDITION OPERATORCONDITION="Equal"><CONSTANT TECH_NAME="@Prompt('Date (Previous Day)','A',',mono,primary_key)"/></CONDITION></FILTER>
    Why, It should be blank??
    Because Date needs no class\object to show up, by default you will get Calendar on the fly.
    Hope you got my point.
    Thank You!!

  • Copy using Variables with multiple single values in BEX

    Hi,
    I have a requirement wherein on executing the planning function, the system should take the FROM and TO values of 0FISCPER and copy the data accordingly.
    Source variable is 'Single Value'.
    Target variable is 'Multiple Single Value'.
    I tried to give the Command Range as below:
    $A$30:$C$31.
    The button sequence is as below:
    VAR_NAME_1      0         ZFISCPER
    VAR_VALUE_1     0
    VAR_NAME_2      1         ZFISCPER_M
    VAR_VALUE_2     1
    In the Analyzer, I entered the values as
    In A30, VAR_NAME_1     0     =C20
    In A31, VAR_NAME_2     1     =C21:C24
    The values that I entered are as below:
    C20 =   2007001 - Source value
    C21 =   2007002 - Target values
    C22 =   2007003
    C23 =   2007004
    C24 =   2007005.
    The problem that Im facing is the system is unable to identify the multiple values that I enter for Target Fiscper and it displays as :#VALUE!
    How to enter multiple single values and reference them accordingly?
    Rgds,
    Shyam

    Hi,
    I have tried to enter multiple single values as below:
    VAR_VALUE_1     0     000  - Source
    VAR_VALUE_1     1     003  -  Target
    VAR_VALUE_2     1     010
    VAR_VALUE_3     1     080
    VAR_VALUE_4     1     099
    When I tried to execute the planning function, the system copies the data from version 000 to ALL versions irrespective of values entered above.ie:
    1
    2
    3
    10
    80
    99
    100
    110
    Rgds
    Shyam

  • Multiple single values variables in cockpit not possible ??

    Hi,
    I'm trying to create a variable in SEM-CPM-MC, but no matter what I do, I'm only able to create a runtime variable with selection type P - Variable for single value. I can select the other values, but when I save the variable, SAP automatically corrects it to P - Singe value again. I can also create a design variable with the other types, but not a runtime variable. How do I create a variable for which you can enter an interval/multiple single values?
    In the documentation it also says, that you should be able to create variables on a frame level. I don't see any button where I can create a variable on a frame level. I've done exactly as it says on help.sap.com, but I don't have a button to create a new variable on a frame level. How do I do that?
    Any help is appreciated and will be rewarded generously :o)
    Thanks,
    ramesh

    Hi Goutham R,
    As of 4.0. it was by a limitation.
    I have read some where that some users were able to meet the requirement by putting a semi colon at the end of each value in a excel and feeding it to the prompt but seems like you have already tried that.
    Please see if you put a vote here in this link:
    Selection option variable not behaving the same way in WebI : View Idea
    But I think this requirement can be met in Analysis edition for OLAP.
    BR
    Prabhith

  • Restrict condition type for single value of Kvgr1 of customer

    Hi Guru,
    I have a requirement in which few condiition should be picked for single value of customer group say(kvgr1-20).
    I know we can create condition table and  assign that field but how i can restrict it for single value.
    Thabk you in advance.

    Hi,
    Kindly do provide some more clarity in your requirement.
    Few condition to be picked based on an single customer group value?
    If possible give an example for our understanding.
    Regards,
    SRK

  • BPS-dynamic columns-single value in the planning level.

    Hello, we would like to use a compound characteristic in dynamic colums.
    Based on test and documentation we already know that we can use compound characteristics in dynamic columns only if the higher-level characteristic is restricted to a single value in the planning level.
    If we use a variable restricted to a singel value per user it does not work. Does it mean in general that a varibel cannot be used in that case and that we have to create about 30 planning packages with a fixed value for the higher level charactersictic?
    Thanks for help.

    This is solved now with support package 12

  • Exit variable with multiple values or with ranges

    Dear Experts,
    I have a date exit variable used in a planning level. If the variable has a single value, I am able to execute the planning function. But if the exit is populated with a range or multiple single values, I am unable to execute the planning function. I get this message 'Variable "ZXPRDATE" is not restricted to a single value'.
    I should be able to read all records from the cube in date range of one week for repost. Please advice if this is possible.
    Thanks,
    Gnana

    Hi Mayank,
    Yes, I am using the same variable for repost function also.
    Let me explain in detial.
    Req: I have a planning level with product, effective date and count(keyfigure). I want all products that has a count keyfigure value for the last one week.
    If my effective date is a single value, I get all the list of products on that particular day. But, if my effective date has multiple dates or a date range, nothing is read from the data base.
    Please advice.
    Thanks,
    Gnana

Maybe you are looking for