(Error RFC 00101) (Error: INF) Large DeskI reports in Infoview.

Hi,
I am getting error u2018No server was available to process the request. Please try again later. (Error RFC 00101) (Error: INF)" while opening a DeskI report in Infoview (BOXIR2 SP4).
Same error appears while viewing scheduled instances of this report. There are more than 1 million rows in the report. WebI report with same data runs properly. No issue in DeskI full client.
I applied the workarounds mentioned in the SAP notes 1199258, 1199491, etc. Also tried using dedicated servers for the report; no impact.
Please advice.
Regards,
Hitesh

Hi Hitestwar,
Try these notes as well
1363743 - '(DA0005)... no default driver specified state: IM002' and 'RFC 00101 Error INF' errors when refreshing a deskI report in InfoView
1202263 - Error: "No server was available to process request. Please try again later. (Error: RFC 00101) (Error: INF)"
1336210 - when refreshing Desktop Intelligence report in InfoView "No server was available to process request. Please try again later. (Error: RFC 00101) (Error: INF)"
1423194 - "No Server was available to process the request. Please try again later. (Error: RFC 00101) (Error: INF)" when refreshing a DeskI document in InfoView
1200315 - No server was available to process the request.Please try again later(Error:RFC 00101)(Error:INF)
You can do another thing in the "Help & Support" section on the http://service.sap.com/support/ search for "Error RFC 00101" you will get more references to this issue.
Or try to set logs on the server and check what is happening.
Thanks,
Vivek

Similar Messages

  • Large DeskI report in Infoview

    Hi,
    I am getting error u2018No server was available to process the request. Please try again later. (Error RFC 00101) (Error: INF)" while opening a DeskI report in Infoview (BOXIR2 SP4).
    Same error appears while viewing scheduled instances of this report. There are more than 1 million rows in the report. WebI report with same data runs properly. No issue in DeskI full client.
    I applied the workarounds mentioned in the SAP notes 1199258, 1199491, etc. Also tried using dedicated servers for the report; no impact.
    Please advice.
    Regards,
    Hitesh

    Hi Hitesh,
    Following information might help you to resolve the issue.
    Issue might be related to timeouts on the connection server.
                                                                                    Please login into CMC and go Home>servers , locate Input and Output File servers and modify timeout of each to be 60 minutes. Default is 10 mins                                                                               
    This 10min default value can be modified in the registry as well:                                                                  
    HKEY_LOCAL_MACHINE\SOFTWARE\Business Objects\Suit 11.5\File Server\Instances\input.<machine name>                                  
    There is a registry key called u201CServerMaxIdleTimeu201D. Modify it and change the decimal value to 90 (default is 10, max is 90).                                                                               
    After this change is made, please restart CMS and FRS servers and test same again. Please let me know the results.                                                                               
    Regards,                                                                               
    Sarbhjeet Kaur

  • Error encountered during DocumentInstance initialization, No server was available to process the request. Please try again later. (Error: RFC 00101)

    Post Author: usaitconsultant
    CA Forum: JAVA
    HiIm trying to initialize my deski document to pass parameter values in prompts. However, Im encountering this error message " No server was available to process the request. Please try again later. (Error: RFC 00101)". Codes below.Anybody encountered this already or know how to resolve this? Please help me, thank you. Source Code:ReportEngines reportEngines = (ReportEngines)enterpriseSession.getService("ReportEngines");ReportEngine reportEngine = reportEngines.getService(ReportEngines.ReportEngineType.FC_REPORT_ENGINE); //DeskiDocumentInstance documentInstance = reportEngine.openDocument(infoObject.getID()); //Error  hereError encountered:Entering getRASConnection()ExceptionError Message: No server was available to process the request. Please try again later. (Error: RFC 00101)

    Hi Prabhat,
    Following solution might be helpful in resolving the issue.
    To resolve the error message
    Log on to the Central Management Console as administrator.
    Click Servers > Desktop Intelligence Report Server.
    Increase the following time-out parameters to at least twice the current value:
    Minutes before Idle connection is closed
    Minutes before an idle report job is closed
    Click Update > Apply.
    The report opens successfully.
    Regards,
    Sarbhjeet Kaur

  • Error: RFC 00101 during DocumentInstance initialization

    Post Author: usaitconsultant
    CA Forum: JAVA
    HiIm trying to initialize my deski document to pass
    parameter values in prompts. However, Im encountering this error
    message " No server was available to process the request. Please try
    again later. (Error: RFC 00101)". Codes below.Anybody encountered this already or know how to resolve this? Please help me, thank you. Source Code:ReportEngines reportEngines = (ReportEngines)enterpriseSession.getService("ReportEngines");ReportEngine reportEngine = reportEngines.getService(ReportEngines.ReportEngineType.FC_REPORT_ENGINE); //DeskiDocumentInstance documentInstance = reportEngine.openDocument(infoObject.getID()); //Error  hereError encountered:Entering getRASConnection()ExceptionError Message: No server was available to process the request. Please try again later. (Error: RFC 00101)

    Hi Tim ,
    If it is webi report . you need to  increse the Maximum connection perameter in Webi server. Default it 50 connects per one Webi Processing server. The best way to create the new webi processing server from the CMS.
    Edited by: Bhargavk on May 11, 2010 7:54 AM
    Edited by: Bhargavk on May 11, 2010 8:19 AM

  • Error  No server was available to process the request. (Error: RFC 00101)

    Hi,
    I am having this error when I try to refresh a report using SDK
    com.businessobjects.rebean.wi.ServerException: No server was available to process the request. Please try again later. (Error: RFC 00101)
            at com.businessobjects.rebean.fc.internal.ras21.RAS21CPIConnection.processRequest(RAS21CPIConnection.java:175)
            at com.businessobjects.rebean.fc.internal.ras21.XMLviaRAS21Encode.processRequestHelper(XMLviaRAS21Encode.java:680)
            at com.businessobjects.rebean.fc.internal.ras21.XMLviaRAS21Encode.openDocument(XMLviaRAS21Encode.java:1167)
            at com.businessobjects.rebean.fc.internal.ras21.RAS21DocumentComAdapter.openDocument(RAS21DocumentComAdapter.java:62)
            at com.businessobjects.rebean.fc.internal.ras21.RAS21ReportEngineComAdapter.openDocument(RAS21ReportEngineComAdapter.java:100)
            at com.businessobjects.rebean.fc.internal.ReportEngineImpl.openDocument(ReportEngineImpl.java:249)
    But all the servers are running....
    I think it could be a timeout problem or somethingelse. Could someone help me ?
    Do you have ever had this error ?
    Regards

    Error's happening on opening the Desktop Intelligence document - it's unable to connect to a Desktop Intelligence Cache Server.
    To check that the server is up - when the exception happens, are you able to refresh a Desktop Intelligence document in InfoView? 
    Any firewalls between your dev box and Enterprise box?
    Sincerely,
    Ted Ueda

  • DeskI report from Infoview - doc.zabo_fc

    Post Author: nagh
    CA Forum: Administration
    In BO XIR2, I tried to edit / create a DeskI report from Infoview on a PC, where no DeskI is installed. Then it prompted me to download a file doc.zabo_fc. I downloaded the file; but even then I could not create / edit a report. So is it correct that, even if we invoke Deski through Infoview (to create/edit a report), we should have a local installation of the DeskI ??  Please clarify.

    Hi nagh,
    Thats right. You need to have DeskI Client locally installed on your machine for the create/edit option from Infoview for deski reports. This is the difference from the earlier 6.5.
    Hope this helps,
    Rahul

  • Error while scheduling DESKI report in infoview

    I m scheduling a DESKI report to users enterprise inbox from infoview using a server group. This server group has DesktopIntelligence Job server, Destination Job server, Adaptive Job server and Program Job servers and all these servers are running.
    When I schedule the report to boldusers enterprise inboxbold it get failed and shows this error message
    bolddestination DLL disabled. []: [CrystalEnterprise.Smtp] bold
    I m wondering what has to be enabled for scheduling a report to infoview's own inbox.

    Abhilash
    You are correct that it shows all the prompts but only when we run the report either directly from the CR Designer or via View on Demand in Infoview/CMC.
    But if I try to schedule an instance of this report, I am getting a check box in the parameter section which says "Show unused parameters" to see this dyanamic prompt. And When I check that box in Infoview still I am not able to select any value for this prompt as it's greyed out.
    Hope I am able to explain my query to you.
    Also attached a screen shot of the scenario for your reference.

  • Err:INF - access to the deski reports by InfoView

    Hi,
    If user do not have rights to the deski application,
    when trying to view the report deski by InfoView - receives an error ERR:INF.
    When you get right to the application deski this is ok.
    I can not find a solution to the problem.
    regards
    Krys
    PS.
    BOXI R2 SP4, Win2003, Apache/Tomcat
    Edited by: Krzysztof Nowicki on Nov 3, 2009 10:31 AM

    We had a similar problem when opening a deskI report with the pdf-viewer. It was solved by the following:
    DesktopIntelligenceProcessingServer : at the end of the textbox Command Line Parameters, change -allowSilentRefresh false in -allowSilentRefresh true
    DesktopIntelligenceCacheServer : at the end of the textbox Command Line Parameters, change -allowSilentRefresh false in -allowSilentRefresh true

  • Unable to run Store Procedure based deski report in Infoview

    Hi All,
    I have a Deski report which is created using Store Procedure. I am able to run report in Full Client Deski. But I am unable to run / schedule same report thorough infoview.
    More details about report
    - Report uses 3 store procedures. When I ran report in infovew I get error message as "SP2 Dataprovider did not refresh properly".  -- SP2 is Dataprovider name.
    - Same report I am able to run in Dev environment. After migration to Model, report fails to run in model infoview.
    - I am able to Run report only for 1st. When I refresh and run with same parameter report shows error.
    Any input will be great help.
    Thanks,
    NV

    Hi,
    Could you please test the following solutions to resolve the issue.
    Solution1:
    Test the issue by inserting the following parameter in .SBO file.
    <Parameter Name="Force SQLExecute">Always</Parameter> .
    Solution2
    Just put SET NOCOUNT OFF in the end of the stored procedure SQL.
    If the above doesnu2019t works then please try the following solution.
    Solution3
    Make the new connection from the scratch using ODBC connection and test the issue.
    I hope this will help you.
    Regards,
    Sarbhjeet Kaur

  • Red Blue issue with published DeskI Report in InfoView

    Hi everyone,
    i'm expieriencing a strange behaviour with my published DeskI Reports.
    I'm using logos in my report and they work just fine... in my full client. As soon as I publish them to InfoView and open them up in the browser, then somehow the color red and blue interchange. Red becomes blue and vice versa...
    My System consists of:
    BOE R 3.1 SP2
    Win Server 2008
    DeskI and WebI
    Has anyone expirienced the same issues?
    Thanks and kr,
    Nils

    Hi Stratos,
    so far everything is just fine. Hope you are doing great too.
    my IE version is: 7.0.5730.13
    Tomcat version: 5.5.20
    If I click on the logos in InfoView, nothing happens.
    I tested 3 different ways to implement them:
    1) via link; pictures shows up, but again with the red blue issue
    2) as an object; pictures shows up; also w/ the red blue issue
    3) inserted a cell, and pasted the picture in it, pictures shows up; also w/ the red blue issue
    The strange thing is, that this issue only appears in the browser.
    Thanks,
    Nils

  • IDES Installation error (RFC connection error)

    Hi
    Would someone help me?
    I have a problem while installing the IDES ,ECC 6.0 with MaxDB. (Linux)
    The installaiton of CI is holding in the phase " Checking the DDIC password "  and it seems a loop.
    Looking through sapinst.log ,  there is some messages.
    These messages are showing as a loop.
    INFO 2008-06-25 13:46:09
    RFC connection information checked successfully.
    ERROR 2008-06-25 13:47:10
    FRF-00007  Unable to open RFC connection.
    ERROR 2008-06-25 13:47:10
    MUT-03025  Caught ERfcExcept in Modulecall: Timeout.
    And I tried to logon ,but I didn't  because of the timeout.
    The window says "waiting for response" and the logon is over with a error,timeout.
    Any hints and advice would be helpful for me ,thanks.

    Hi,
    1. Check dailog work processes through OS level
    2. Check all profile parameters through OS level and change it according.
    3. Then try for sap logon with 000 client and password.
    After login into sap, check RFC connection within the system. using by tcode sm59.
    4. Finally you can check also MaxDB services at OS level.
    Regards,
    Srini Nookala
    Edited by: Srini Nookala on Jun 28, 2008 6:11 AM

  • How Can I Schedule a Deski Report in Infoview that has a VBA Macro

    Hi experts,
    i've made a report that has a vba Macro. I published it in infoview. If I launch it manually (clicking on the refresh button) the macro works normaly. If I schedule it the macro doesn't work.
    What can I do?
    Is it possible to make a program that simulate the opening and click on the refresh button?
    Or i there is another solution?
    Here is my Macro:
    Private Sub Document_AfterRefresh()
    Dim filtervar As Variant
    Dim filterText, Filter As Long
    Dim DocName, NewName As String
    Dim Pathing, TodaysDate As String
    Dim folderName As String
    TodaysDate = Format(Date, "DDMMYYYY")
    Pathing = "
    Ktsdwh0\c$\OutputBO\"
    DocName = ThisDocument.Name
    filterText = "Dpre Cod Produttore"
    filtervar = ThisDocument.Evaluate("=<" & filterText & ">", boUniqueValues)
    For Each sepval In filtervar
        Filter = sepval
        For n = 1 To ThisDocument.Reports.Count
            Call ThisDocument.Reports(n).AddComplexFilter(filterText, "=<" & filterText & "> = " & Filter)
            ThisDocument.Reports(n).ForceCompute
        Next n
            MkDir (Pathing & Filter & "\")
            NewName = Pathing & Filter & "\" & Filter & "-" & TodaysDate & "-" & DocName   'for Prova_Prod.rep
    '        NewName = Pathing & Filter & "-" & TodaysDate & "-" & DocName   'for Prova_Prod.rep
            ThisDocument.ExportAsPDF (NewName)           'to Save as PDF
    Next
        For n = 1 To ThisDocument.Reports.Count
          Call ActiveReport.AddComplexFilter(filterText, "=<" & filterText & "> = <" & filterText & ">")
            ' To delete a Complex Filter, you set it equal to itself...
          ActiveReport.ForceCompute
        Next n
    End Sub
    Please Help!
    Best regards
    Camillo

    Hi Philippe,
    If you are using Windows 2003 with SP2 then it might be the issue as already logged for BOXIR2.
    You can test the issue by using only Windows 2003 without SP2.
    In case your operating system is only windows 2003 then following information and code might be helpful for you to resolve the issue.
    There are a number of things to check when setting up a macro to work through Infoview or scheduled. The first thing is that the macro needs to be triggered to run. This is done by putting a call to the macro in the Document_BeforeRefresh or the Document_AfterRefresh event handler.
    The report server and job server are designed to process one report at a time. Through a macro it is possible to open more than one report, and do various processing with those additional reports. Since the report and job servers are not designed to process more than one report, your macro should not open an additional report.
    The fact that only one report is processed at a time also affects the syntax you should use when referring to a document or report object. In the DeskI client you can use the ThisDocument object to refer to the report which is running the macro. You can also use the ActiveDocument object to refer to the report that is currently displayed. Most of the time these two objects will point to the same report. When the report server or job server process a report there would never be the possibility for a different report to be active, so the ActiveDocument object does not exist. This also applies to the ActiveReport object. Instead of using ActiveDocument your macro code should use the ThisDocument object. Instead of using the ActiveReport object you should use ThisDocument.Reports.Item(1) to refer to this first report tab in a report.
    These items are the most common issues that will cause a macro not to run through Infoview or when scheduled. The best way to debug a macro which is not working in either of those places is to include code which will log the macro's progress to a file. This makes it easy to determine exactly which line of code is causing issues so that it can potentially be corrected.
    #Region u201CWeb Form Designer Generated Code "
    'This call is required by the Web Form Designer.
    <System.Diagnostics.DebuggerStepThrough()> Private Sub InitializeComponent()
    End Sub
    Private Sub Page_Init(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Init
    'CODEGEN: This method call is required by the Web Form Designer
    'Do not modify it using the code editor.
    InitializeComponent()
    End Sub
    #End Region
    Private Sub Page_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load
    Dim myInfoStore As InfoStore
    Dim myEnterpriseSession As EnterpriseSession
    myInfoStore = CType(Session("InfoStore"), InfoStore)
    myEnterpriseSession = CType(Session("EnterpriseSession"), EnterpriseSession)
    Dim DOCUMENT_NAME As String = "document_name"
    Dim query As String = "Select SI_ID, SI_NAME, SI_SUBJECT, " _
    & "SI_COMMENTS, SI_OWNER From CI_INFOOBJECTS Where SI_KIND = 'FullClient' " _
    & "AND SI_INSTANCE=0 AND SI_NAME='" + DOCUMENT_NAME + "'"
    Dim myInfoObjects As InfoObjects = myInfoStore.Query(query)
    Dim myInfoObject As InfoObject = myInfoObjects(1)
    Dim myDeskiDoc As FullClient = CType(myInfoObject, FullClient)
    Dim mySchedulingInfo As SchedulingInfo = myDeskiDoc.SchedulingInfo
    mySchedulingInfo.Type = CeScheduleType.ceScheduleTypeOnce
    mySchedulingInfo.RightNow = True
    Dim myFullClientFormatOptions As FullClientFormatOptions = myDeskiDoc.FullClientFormatOptions
    myFullClientFormatOptions.Format = BusinessObjects.Enterprise.Desktop.CeFullClientFormat.ceFullClientFormatFullClient
    myInfoStore.Schedule(myInfoObjects)
    End Sub
    End Class
    I hope this will help you.
    Regards,
    Sarbhjeet Kaur

  • RFC system error for destination GTADIR_SERVER

    I just installed trial version 7.0 ABAP SP12. I started the learning path displayed in SE80, create a table and some class for working with it.
    When trying to create a data-element I get the error "RFC system error for destination GTADIR_SERVER". Any hints about what this server is and how to set it up?

    This message is not supposed to appear for customers, but it doesn't cause any harm either.  You can click through and ignore it. 
    The message is removed for customers in SP13.  Check OSS Note 1063482.

  • RFC system error

    Hello friends,
          During Table and structure creation i am getting error "RFC system error for destination GTADIR_SERVER" while i am creating domain and data element for that perticular table/structure. Please give me some information about GTADIR_SERVER and also provide information to rectify this error.
    Thanx & Regards,
    Rahul Talele

    Hi,
    In this case please contact your basis. Because it's due to wrong patch. Please install recent patch.
    Best regards,
    Wojciech

  • Webi and Deski report engine ports

    We're having problems connecting to the webi or deski report engines through a firewall with BO XI R2 Java SDK. We've followed this document extensively :
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/0047e5f4-3140-2b10-1bae-de175e4c741c
    We've set the -port and -requestport switches but the opendocument call always hangs and eventually gives out the error :
    No server was available to process the request. Please try again later. (Error: RFC 00101)
    Its definitely a firewall issue - I can turn off the firewall to solve it, but obviously that's not a long term solution.
    I believe we have configured the servers correctly according to that document given we managed to successfully connect to the CMS through a firewall following the same procedure.
    If anyone has any experience connecting to the RAS webi / deski servers through a firewall via the Java SDK, please let me know.
    Greg.

    You should only be getting the getRASConnection() method log with Desktop Intelligence, since the internal server name is RAS21.  It's distinct from the public server name RAS (Report Application Server) that's specific to Crystal Reports.  Not trying to harp on this, just an FYI when posting.
    How about the Desktop Intelligence Cache Server?  All communications to the Desktop Intelligence Report Server goes through the Cache Server.  So it's SDK <-> DeskI Cache <-> DeskI Report Server.
    Sincerely, 
    Ted Ueda

Maybe you are looking for

  • Problems Camera Raw in Trial-PS CC

    Hi folks, just downloaded a trial-version of PS CC and wanted to use the new perspective-straighten-feature of camera raw on a jpg but sadly this feature does not show up. What am I doing wrong? Best, Robert

  • Issue with OLEDB Source in BIML

    Hi all, I am trying to automate a data flow with BIML. I am using an expression to build my SQL dynamically based on input parameter. Sparing details of the use case, I need this flexibility in my project. I am having 1 master table which consists of

  • Optimization Help ?? Pl/sql procedure

    Hi people, I have 2 procedure and they are taking forever to complete. I need your help in optimizing those procedures to finish my task. My task is data migration. I am using Oracle 11g , DQL Dev 3.0 I have to migrate about 2 million records. I woul

  • When I print a PDF it always prints as a booklet, how can I print 1 full page?

    When I print a PDF it always prints as a booklet, how do I print a full page?

  • Created a technical sys. & a buss system,but its nt visible in Integrtn dir

    Hello friends, I am following "Configuring IDOC-XI-IDOC Scenarios.pdf guide". It says we have to maintain System Landscape Directory(SLD), where we have to create a technical System and a bussiness system. I have done that . Then it says In the Integ