Error when activating an ODS

Hi,
I am trying to activate an ODS but I get the error message "Log  could not be written on output device T". If I check it I see that the ODS is consistent.
Thanks
Miguel

Hi,
Also Refer:
Re: How to activate InfoCube 0SD_C03
With rgds,
Anil Kumar Sharma .P
Assign the points,if it helps you.

Similar Messages

  • Errors when activating ODS

    Hello,
    i am trying to activate freshly installed ODS from business content.
    it gives following errors:
         RFC connection to source system BWDCLNT210 is damaged ==> no Metadata upload     
         Error when creating the export DataSource and dependent Objects     
    Please suggest...
    regards,

    hi Aby,
    try if right click source system BWDCLNT210 'restore'
    check threads
    RFC connection to source system Damaged
    check oss note 597326 - Activating ODS: Error when creating the export DataSource
    Symptom
    When you activate or transport ODS objects, the following errors appear in the log:
    "The creation of the export DataSource failed". Message number RSBM 035
    "Error &1 in function module &2". Message number RSBM 006
    "Error when creating the export DataSource and dependent Objects". Message number RSDODSO 169
    "Error when activating the ODS object &1". Message number RSDODSO 168
    Other terms
    RSBM 035, RSBM 006, RSDODSO 169, RSDODSO 168
    Reason and Prerequisites
    A characteristic involved is active but it is using new or inactive attributes.
    Characteristics involved are all characteristics used in the ODS object.
    Solution
    Check all characteristics involved as described in the following:
    Check the Compounding and Attributes tabs in the characteristics maintenance.
    All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.
    help.

  • "Error when activating update rule" after changing ODS key

    Hi Gurus,
    I have problem when transporting in productive system an existing ODS & the update rule linked. The message is  :  "Error when activating update rule".
    This is when i move one field from the key to a simple field of the ODS.
    Before transporting requests, i deleted data in the ODS by right-click on ODS --> Request tab --> select the request --> click on delete....
    I don't understand because i did the same in Qual environment and everything is OK : transport request & ODS loading...
    Please help.....

    Hello,
    Please try to check/perform the following steps:
    1- You must ensure for the update rule have mapping between infosources
       and ODS/CUBEs correct, this means that also these objects need
       to be of the same version in the source system of the transport as in
       target system.
    2- Please ensure all infoobjects in the cube are active.Please
       reactivate all the objects again in source system.
    3- Ensure all infoobjects are found in the communication structure.
    4- Please try to collect the update rule via BW transport connection
       with the grouping option "only necessary objects" and then transport
       those objects again.
    Could you please reactivate the infocube and its update rules again
    and then create a new transport for this infocube and transport it
    again.
    Best regards,
    Paula Csete

  • Facing error when activating ODS

    Hi All,
    i am facing error when activating ODS. THe load was succesfull. when i checked in RSMO detail screen all the data packets are green but under subsequent processing it shows following error message
    1.Activation of data records from ODS object ZOPA_8 terminated
    2.Error when assigning SID: Action VAL_SID_CONVERT table 0MATERIAL
    3.Error getting SID for ODS object ZOPA_8
    "And under others also it is showing same message.
    Can any one please suggest how to solve this issue. Its very urgent.
    Waiting for appropriate solution...
    thanks
    kamal

    Hi,
    Check the following.
    1.  0MATERIAL  might be the reference char for ZOPA_8.
    2.  If so, then need to check conversion routines are same for both.
    3.  Then check the data (In PSA) under ZOPA_8 and check if it has any special chars or failing due to conversion routine.
    4. Correct data and load it again.
    Hope it works.
    Regards,
    Aditya

  • Error when activating ODS

    Hi,
        I  am getting an error - Error during confirmation of process 000001
    Message no. RSODSO_TOOLS087 when activating a ODS in the process chain.
    The error also says - Activation of M records from DataStore object ZDISTSEC terminated
    Message no. RSM1102
    Can anyone help....
    Thanks  in advance,

    Hi Romina,
    have you run the report that comes with this note?
    No. 4) in the above mentioned note refers to not-write-optimized ODSs, but only if the database-system is ORACLE. It says if you have to do repartitioning in MSSQL, you'd have to post an OSS request.
    I'm actually having the same poblem, but with Oracle as the DB-system. I'm still experimenting with this note.
    ~ Barbara

  • Error when activating update rule after transporting to QA

    Hi,
    When we transport Info cubes and update rules along with Process chains. There are the following errors in Transport request(XXXXXXXX).
    1. Error when activating update rule 22HSFD3ZMALU46LS0R8PRF2MW
    IC=ZSDPCXY2 IS=2LIS_11_VAITM error when checking the update rules
    2. Error when activating update rule 7NT4WIDPDCN2ERFDRXIGH95PM
    IC=ZSDPCXY2 IS=2LIS_12_VCHDR error when checking the update rules
    and etc.
    Then we activated and saved all the erroneous update rules in another tranport request(YYYYYYYY) and again we transported alongwith the previous transport request(XXXXXXXX).
    The last request(YYYYYYYY)was successfully tranported and still there are same errors in TR(XXXXXXXX).
    Quick answers will be highly appreciated.
    Regards,
    Vijay

    Hi Vijay,
    Next time you would have transport only (YYYYYYYY). Transport Request (XXXXXXX) was not required to be moved.
    Normally Update Rule gets deactivated in QA when any changes to the CUbe/ODS are moved.
    Thus either you can transport transport request for only active update rule to QA or activate your UR directly in QA system in case you have authorization to do that.
    Regards,
    Rohini

  • Error while activating 0FIGL_O02 ODS

    Hi ,
    It showing error while activating 0FIGL_O02 ODS .I have already allowed all special character "ALL_CAPITAL,.<>?/:;"{}[]||=-)(*&^%$#@!~`"'-_,ALL_CAPITAL_PLUS_HEX",but it's still showing error in particular field  0DOC_HD_TXT .
    Errror:Value 'AMITBHANDARKAR          ' (hex. '41004D00490054004200480041004E004400410052004B0041
    Error when assigning SID: Action VAL_SID_CONVERT InfoObject 0DOC_HD_TXT
    What is the error in this name.

    Hi rajesh ,
    While activation and creating the SIDs the system will perform the sanity check which will ensure to throgh th error if u trying to load some lower cse letter to IO which doent have the u lowercase check box as checked. You can edit the IO then and also proceed with saveen suggested by processing all capital.
    Thanks,
    Deepak

  • Error when activating DataStore Object

    Hello,
    We have an ODS object which is in avtive stage in ECC DEV system. When
    we transport it to ECC QA system it can not be activated and shows
    follwoing errors :
    1) Internal error occurred when writing
    Message no. D0054
    2) Error while saving change log for DataStore object DSO_PL
    Message no. RSDODSO196
    3) Error during creation of DDIC sources of DataStore Object DSO_PL
    Message no. RSO435
    4) Error when activating DataStore Object DSO_PL
    Message no. RSO404
    We also observe that even we create new ODS object in ECC QA system,
    still it give the same errors while activating.
    Note - ECC QA is a system copy of ECC PROD.
    Please suggest.

    Hi,
    I believe the problem is with the Myself connection (the BW source system connection to itself) in the QA system.
    Please goto RSA1, 'source systems', right click on the myself system and click on 'check', if there are errors you
    maybe able to correct them by right clicking on the myself connection and click on 'restore'. If there are no
    errors for the myself connection you should go to sm59 and do the connection and authorization test for the
    RFC connection for the myself connection.
    Best Regards,
    Des.

  • Error when activating DTP  in

    hi  guys
    I am trying load one ods to another ods . and when I create DTP and try to activate it throwing some weird message like
    Creation of PSA /BIC/B0003852 failed
    Error during creation of DDIC sources of Data Transfer Process DTP_4B6GPTZCLXHMKF405417M6KEX
    Error when activating Data Transfer Process DTP_4B6GPTZCLXHMKF405417M6KEX
    I donu2019t know what is this Causing error ..my source dso is correct has data ..but unable activate this  ..
    Any clue ?

    Hi,
    I think you have to create export datasource for the first DSO and then check creating the DTP.
    Hope this helps..........
    Rgs,
    Ravikanth.

  • Error when activating update rule

    HI BI Expert,
    The original transfer rule for 2LIS_11_VAITM was deleted accidently and I created new one and mapped with the existing infosource. The system always generates the following error at the time of transport to another client.
    Error when activating update rule D1GOAPD9O0P9CFOY8KBSOUDFA
    Activation of the update rules for ZO_SOP_1 ZT_SOP_SALO_ITM
    IC=ZO_SOP_1 IS=ZT_SOP_SALO_ITM error when checking the update rules.
    Would you kindly be able to suggest me what steps I need to take so as to correct this issue?
    Thanks.

    Hi,
    When you say that update rule was accidently deleted, was that attached to transport request and transported to your QA & PRD at that time.
    Because it may happen that, your old rules are still there in QA & PRD and the new rules are failing to overwrite that.
    If it is the case, then you may have to open the client for QA & PRD and delete the existing update rule (doesnt sound good practice though), and then create a fresh update rule and transport.
    Rgds,
    Vikram.
    Rgds,
    Vikram.

  • 0FIA_DS11:Error when activating DataStore Object

    Hi,
    We have activated the datasources related FI_AA and replicated in to a new BI 7 system.
    Currently we are able to activate the asset accounting related targets like 0FIAA_C11, 0FIAA_c12 and 0FIAA_C13
    however not able to activate DSO's 0FI_DS11, 0FI_DS12 and 0FI_DS13.
    We have replicated the datasources 0FI_AA_11 and 0FI_AA_12  in 3.x but while installing the DSO 0FI_DS11 and 0FI_DS12, facing below given  error.
    " DataSource 80FIA_DS11 does not exist in source system BIDCLNT600 of version A     
    Error when creating the export DataSource and dependent Objects
    Error when activating DataStore Object 0FIA_DS11 "
    We have checked the mysource system settings and activated the Data Marts respectively but still we are not able to activate.
    System is BI 7 with EHP4 ehanced packege.
    Please suggest.
    Thanks & Regards,
    SMS

    Hi Jonas,
    I understand the procedures and had followed all the procedures.
    We had resolved the issue and issue was with the IP in sm59.
    It is cleared.
    Thanks for the reply.
    Regards,
    S M S

  • Error when activating Real Time Data Source

    Hi..
    I created a generic datasource in R/3 system via RSO2, with the Real-time check box enabled in the settings for Generic Delta. I saved the datasource. Replicated it into BW System.
    I tried to activate this Real time Data Source in BW, it says "Error when activating Data Source".
    I am on BI 7.0, with PI_BASIS: 2005_1_700.
    Please let me know if you need any further information.
    Thanks,
    Sai.

    Hi sai,
    Can you specify from where you have created your geneic data source like by using DB tabl/view/infoset query.
    am

  • Error when activating an R/3 generic datasource in BW

    Hi
    I've created a generic datasource in R/3 4.6C system using a table view over R/3 standard Project System tables with joins.  This datasource has been activated. I then replicated this generic datasource in BI7 datawarehousing environment.  The replication went ok and I could see the R/3 generic datasource in RSA1.  When I tried to activate this datasource I received this error message:
    Error when activating DataSource ZPROJECT_ATTR Message no. RSO404
    I didnt have similar problem with the other generic datasources.
    I'm currently working on Netweaver 2004s BI support pack 10 environment.
    Please let me know how to fix this problem.
    Many thanks,
    Anthony

    Hi Anthony,
    Do go through the note's detailed text and do listen to this advice from an old man.  Do read the section below in the note and do assign some points to this geezer "lying" on his deathbed.
    Quote from the note (this one rhymes..yaa):
    Source system = R/3 Release 4.0B ff (all subsequent releases including 4.7 and so on)
                = BW Datamart 2.0B, 2.1C, 3.0B, 3.10, 3.50, 7.00 ff
                = CRM release 2.0, 3.0, 4.0 ff
    unquote...
    Cheers
    Neeraj

  • Error during activation of ODS data

    Hi all,
    I am getting error during activation of ODS data.
    Error: Error occur during activation.
    How to check , where that error exactly occurs.
    Appreciating any response.

    Hi Santosh,
    SM37 is mainly for monitoring the back ground jobs...... both in R/3 side and BW side this is same.. just for monitoring the background jobs... fisrt by using SM36 basis people will schedule in background.. and we just identify.. which are completed and which are not completed... in SM37.
    there are various status they are
    PLANNED
    RELEASED
    CANCELLED
    ACTIVE
    FINISHED
    READY
    Check this link
    http://help.sap.com/saphelp_nw04/helpdata/en/c4/3a8016505211d189550000e829fbbd/frameset.htm
    In Sm37 u can see the different options for background jobs, like Scheduled, released, ready,active, finished, canceled.. If u want to know the Status of the current running job, U just type the job name, user name then click execute(F8).
    hope this helps
    regards
    Karthik
    Assign points if helpful

  • Error when activating the master data

    Hi
    I am getting the following error when activating the master data. when using IDOC as transfer method in transfer rules
    <b>Error while creating table 'EDISEGMENT' entry '/BIC/CIRB0CLASS_NUM_TEXT'</b>
    If anyone came across this kind of problem plz share the solution.
    Regards
    Annie

    Hi
    I solved the problem. AFter changing from PSA to IDOC, i just saved first and activated. it got activated. But thanks for the response.
    There are no short dumps in ST22
    Regards
    Annie

Maybe you are looking for

  • How to store an image into MySQL db using BlazeDS and Hibernate?

    Hi! I am using Flash Builder 4.6, BlazeDS, and Hibernate. How to store a webcam snapshot into the MySql Database. I stored Form Items by using RemoteObject into the database. But I failed to store webcam snapshot. I captured that image on Panel compo

  • I wish:  Sequential (non-synchronous) loading of tabs . . .

    What I would like as an option in Preferences ( Safari ), is the ability to select "one tab at a time" tab loading when doing a multiple tab selection in any particular window. In other words, load one tab at a time successfully, and then load the ne

  • How do i install face time on imac os x 10.5.8

    how do i install facetime on imac os x 10.5.8

  • Need help on this program

    Hi all, The purpose of this program is listed in here: // Inputs the miles driven and gallons used (both integers) for each tankful. // Calculates and displays miles per gallon obtained for each tankful and print // the combined miles per gallon obta

  • How to config movement type 261?