Error when open search help

Hey,
I am getting the this error :- "Sending of dynpro SAPLHRBAS00SEARCH_INTERNAL 4100 not possible: No window system type specified" while using the search help PLOM.
Any info will be of great help!
Thanks
Salah Afia

Hi Salah Afia  ,
            Try using the search help KRED_C instead. please use and reply ..
Regards
Puneet

Similar Messages

  • Win32 exception error when opening file from RH6 in RH7

    I received the following error when opening a help file
    (.xpj) that was developed in RoboHelp 6 in RoboHelp 7:
    An unhandled win32 exception error occurred in RoboHTML.exe
    [4692].
    This occurred after receiving the notice to upgrade the
    project since it was created in an older version. After selecting
    Upgrade, I received a runtime error message prompt. After clicking
    OK, I received the message above.
    Does anyone know how to resolve this issue so that I can open
    the project without any problems in RH 7?

    Thanks a lot for replying.
    waldemar.hersacher wrote:
    I have Acrobat Reader 5.1 at home and 6 at work and both work fine with the LV 7.1.1 bookshelf and help file.
    Yep, I just uninstalled Adobe Reader 7.0 and installed version 6.0.1. The links now work perfectly, so evidently this is a problem with Adobe Reader 7.0. I'd still like to solve the problem, though, as I really like version 7.0. (Something has finally been done about the program's lengthy start-up time!)
    You can reach the PDF-Files also by using Help>>Search the LabVIEW Bookshelf. Does this link work for you?
    It works perfectly.
    javascript:AcrobatLink('../manuals/lvuser.pdf');
    This is a call to a java script function located in pdf.js.
    Other reasons:
    The Active-X control of Reader 7 has a bug.
    Your Internet security settings will not allow this operation. The Active-X will be loaded but will have no access to the file and yo get a wrong error message.
    Fair enough. If that is indeed the case, which Internet security setting should I try changing? I haven't done anything unusual to any of those settings. And where is pdf.js located? I tried searching for it but could not find it.
    Your advice is greatly apreciated.

  • Error when opening an RFC connection in IDT

    Hi Experts,
    I m trying to create a relational connection (JCO) from IDT to BW 7.4, and I m getting the following error:
    Error when opening an RFC connection (CPIC-CALL: ' ThSAPOCMINIT', communication
    I searched this error in Internet and I found many discussions about it ...And I think it's about autorizations in BW system that by default dosen't allow external servers to connect to it.
    So, I changed the values for the following parameters in RZ11 t-code:
    gw/acl_mode = 0
    gw/reg_no_conn_info = 0
    But I still get the same error ...When I checked the SM59 t-code I found that IDT create an entry in TCP/Ip connections ...
    Can you guide me to solve this issue...
    BW server is 7.4 version on AIX OS
    BO server is 4.1 SP05 on windows system
    Thank's a lot for your help.
    Abdess,

    Hi,
    test the RFC connection in sm59.If it is sussecfull then try to create conneciton otherwise see the error message.
    Amit

  • Error when opening document with ECL control: INVALID_DATA

    Hi Gurus,
    I've tried to search the net for this problem but could not find anything and I'm stuck now.
    Description:
    we're using ECL to view attached documents (to POs etc.) which are stored through ArchiveLink on the content repository.
    when we try to open this document, time-to-time we get following error:
    Error when opening document with ECL control: INVALID_DATA
    Message no. SDV004
    by time-to-time I mean that when we try to open same attachment again it opens successfully (sometimes we need to re-open it 3-4 times to get it)
    what we've tried is to enlarge timeout for HTTP protocol (tx SMICM, from former 30 to actual 60) but only effect we got is that we're waiting for the error longer time
    It will be really great if anybody of you guys can give me an advice where the problem can be or where should I look and what to check
    Thanks,
    David

    Hi Christoph,
    thanks for tip, unfortunately this was already flagged, currently settings are:
    for Display Settings:
    yes - include ECL control
    use HTML control
    empty - maximum viewer wait time
    (do you think that setting some value for this could help)
    yes - deactivate generic object services in viewer
    no - doc display as dialog box
    yes - deactivate data provider cache
    Storage Settings:
    yes - always copy document class from document type
    yes - permit multiple assignment
    Thanks,
    David

  • Error When Opening Any Form

    Hi All.,
    Im facing some issue while opening any form..its stuck in below mention file while opening any form i tried all the ways still im not able to fix the issue.
    Application:11.5.10.2
    OS-----------HP-UX
    DB-----------10.2.0.4.0
    File Name:
    oracle/forms/ui/FLWTextArea
    Work Around
    Relink the all the files
    Regenerated the jar files
    Regenerated the forms
    f60gen help=y
    Forms 6.0 (Form Compiler) Version 6.0.8.28.0 (Production)
    Forms 6.0 (Form Compiler): Release - Production
    (c) Copyright 1999 Oracle Corporation. All rights reserved.
    PL/SQL Version 8.0.6.3.0 (Production)
    Oracle Procedure Builder V6.0.8.21.0 Build #0 - Production
    Oracle Virtual Graphics System Version 6.0.5.39.0 (Production)
    Oracle Multimedia Version 6.0.8.25.0 (Production)
    Oracle Tools Integration Version 6.0.8.17.0 (Production)
    Oracle Tools Common Area Version 6.0.5.32.0
    Oracle CORE Version 4.0.6.0.0 - Production
    Metalink Doc id
    java.lang.NoClassDefFoundError: oracle/forms/ui/FLWTextArea Error When Opening Any Form [ID 1219663.1]

    Thanks,
    From the below doc id we are currently in patch set 19 but im not able see that in ad_bugs.,
    Note: 232313.1 - Information on Previous Versions of Developer 6i Patchsets
    https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=232313.1
    Here is an example:
    If you have Forms: 6.0.8.27.x --> You are on Developer 6i Patch 18
    If you have Forms: 6.0.8.26.x --> You are on Developer 6i Patch 17
    If you have Forms: 6.0.8.25.x --> You are on Developer 6i Patch 16
    If you have Forms: 6.0.8.24.x --> You are on Developer 6i Patch 15
    SQL> select bug_number from ad_bugs where bug_number='&BUG_NUMBER';
    Enter value for bug_number: 9935935
    old 1: select bug_number from ad_bugs where bug_number='&BUG_NUMBER'
    new 1: select bug_number from ad_bugs where bug_number='9935935'
    no rows selected
    SQL>

  • Error when opening an RFC connection (LB : Hostname or service of the messa

    Hi All,
    Im trying to transport datasources in BW, they are 7.x  RSDS datasources. but we did not change the source system, it was existing and we are using the same source for older BW version. we now installing new BW 7.x system.
    These  transports went fine in BQ system but failing in BP system with the below error :
    Error when opening an RFC connection (LB : Hostname or service of the message ser
    Error when activating DataSource 2LIS_17_I0NOTIF RP1CLT100
    Error when opening an RFC connection (LB : Hostname or service of the message ser
    Error when resetting DataSource 2LIS_17_I0NOTIF RP1CLT100 to the active version
    the datasource 2LIS_17_I0NOTIF is active in RP1CLT100 system. when this transport goes to prod it tries to overwrite the existing one, as there are no changes to the datasource the structure will be the same.
    but after that it cant able to activate that datasource.
    so my question is can we able to activate this datasource in RP rather than doing transport again from R/3 Dev---R/3 PRD.
    i tried RSDS_DATASOURCE_ACTIVATE_ALL but it doesn't help.
    another question is when we migrate from 3.x datasource to 7.x, does this change any metadata in R/3 system as well.
    Best Regards
    Robyn.

    Hi Rizwan,
    Looking at the error message it seems like there is some issue with RFC connection and whatever objects you are trying to move are not reaching to target system. Just have a check with basis team.
    Once you migrate DS from 3.x to 7.0 yes there will be some meta data changes e.g. the DS type will be changed from ISFS to RSDS. You will have to send the migration along with current data source.
    Regards,
    Durgesh.

  • Error when opening table container file keydb read only

    Hi Guys,
    We are installing solution manager 4.0 on windows/sql but we are getting following error and couldnt continue the installation
    FKD-00070  Error when opening table container file C:\PROGRA1\SAPINS1\SOLMAN\SYSTEM\MSS\CENTRAL\AS\keydb.xml for writing. Possible reason: "read-only"
    ERROR 2008-06-04 20:10:56.843
    FKD-00049  XML - Parser error: error: no DTD specified, can't validate in line 1, 1
    in file C:\Program Files\sapinst_instdir\SOLMAN\SYSTEM\MSS\CENTRAL\AS\keydb.xml.
    Please help
    Regards,
    Santosh

    Further info
    keydb.xml is empty and the directory has got write access for everyone
    regards
    Edited by: Santosh Keerti on Jun 4, 2008 1:29 PM

  • Error When Opening Document

    I receive the following error when opening a Web Intelligence Document, no matter the user.
    C​a​n​n​o​t​ ​i​n​i​t​i​a​l​i​z​e​ ​R​e​p​o​r​t​ ​E​n​g​i​n​e​ ​s​e​r​v​e​r​.​ ​(​E​r​r​o​r​:​ ​R​W​I​ ​0​0​2​2​6​)​ ​(​E​r​r​o​r​:​ ​I​N​F​ ​)
    I also cannot run any reports. Anyone have an idea? I cannot seem to find any information in the knowledgebase on that error.

    Phasenjager,
    It appears that in the past few days you have not received a response to your
    posting. That concerns us, and has triggered this automated reply.
    Has your problem been resolved? If not, you might try one of the following options:
    - Visit http://support.novell.com and search the knowledgebase and/or check all
    the other self support options and support programs available.
    - You could also try posting your message again. Make sure it is posted in the
    correct newsgroup. (http://forums.novell.com)
    Be sure to read the forum FAQ about what to expect in the way of responses:
    http://forums.novell.com/faq.php
    If this is a reply to a duplicate posting, please ignore and accept our apologies
    and rest assured we will issue a stern reprimand to our posting bot.
    Good luck!
    Your Novell Product Support Forums Team
    http://forums.novell.com/

  • Error when opening User and Group Preferences

    After upgrading to Lion there is an error when opening User and Group Preferences.
    I´ve repaired permissions but the problem is still there...
    Thanks...

    Hi,
    Double click on ur webdynpro application.Go to application properties tab.create new application property,select predefined property->browse->it will open a popup->select expiration time->give the value for expiration time.
    or
    Refer the note : [842635|https://websmp230.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=842635&nlang=EN&smpsrv=https%3a%2f%2fwebsmp206%2esap-ag%2ede]
    Hope it helps,
    Reward points if helpful.
    Regards,
    Shailesh Nagar

  • Error When Opening the Transactions/Transactions Window

    Hi All,
    in Oracle E-Business Suite R12 Version
    Error When Opening the Transactions/Transactions Window
    ORA-06502: PL/SQL: numeric or value error
    ORA-06512: at "APPS.AR_MO_GLOBAL_CACHE", line 55
    ORA-06512: at "APPS.ARP_STANDARD", line 2912
    ORA-06512: at "APPS.ARP_GLOBAL", line 282
    FRM-40735: PRE-FORM trigger raised unhandled exception ORA-06502
    Can any body help about the error
    Thanks in advance.

    Did you go through the below notes:
    Note:125204.1, Note:153207.1 and Note:191306.1.

  • Error in Local Message System: Error when opening an RFC connection Message

    Hi Gurus,
    We are not able to create support messages in our ECC production system but it can created in Development and Quality. Support message created appears in solution manager system. ECC System displays error message as
    Error in Local Message System: Error when opening
    an RFC connection Message was Not Created
    I have checked RFC connection between ECC and Solution Manager which displays following message
    Logon     Connection Error
    Error Details     Error when opening an RFC connection
    Error Details     ERROR: partner "local:sapgw00' not reached
    Error Details     LOCATION: SAP-Gateway on host local / sapgw05
    Error Details     DETAIL: NiPConnect2
    Error Details     CALL: connect
    Error Details     COMPONENT: NI (network interface)
    Error Details     COUNTER: 40142
    Error Details     ERROR NUMBER: 10060
    Error Details     ERROR TEXT: WSAETIMEDOUT: Connection timed out
    Error Details     MODULE: nixxi.cpp
    Error Details     LINE: 2835
    Error Details     RETURN CODE: -10
    Error Details     SUBRC: 0
    Error Details     RELEASE: 701
    Error Details     TIME: Wed Jan 11 23:26:54 2012
    Error Details     VERSION: 38
    Kindly Help.....

    Hi
    Based on the instance number of the servers, you can determine the gateway to be used.
    IF your ECC instance number is , 01 then gateway would be , sapgw01 (in ECC system)
    So check and change the settings accordingly, in the RFC connection. Also check, if this entry sapgw01 is made in /etc/service file. Also check, in transaction smgw for gateway parameters.
    Hope this info helps,
    ~ Raj

  • Java Error When opening ER Model in Jdev 11g release 2

    Dear All,
    I m getting below error when opening my ER model in jDev
    java.lang.IllegalArgumentException: Ref is null
         at oracle.modeler.dif.ModelerGraphicBridge.findBridgeFromRef(ModelerGraphicBridge.java:343)
         at oracle.modeler.dif.ModelerGraphicBridge.createEdgeGraphic(ModelerGraphicBridge.java:267)
         at oracle.modeler.dif.ModelerGraphicBridge.createEdgeGraphic(ModelerGraphicBridge.java:86)
         at oracle.diagram.dif.GraphEdge.createGraphic(GraphEdge.java:152)
         at oracle.diagram.dif.GraphElement.createContainedGraphics(GraphElement.java:213)
         at oracle.modeler.shape.config.DefaultDiagramGraphicBridge.createDiagramGraphic(DefaultDiagramGraphicBridge.java:122)
         at oracle.modeler.dif.ModelerGraphicBridge.createDiagramGraphic(ModelerGraphicBridge.java:250)
         at oracle.modeler.dif.ModelerGraphicBridge.createDiagramGraphic(ModelerGraphicBridge.java:86)
         at oracle.diagram.dif.Diagram.createGraphic(Diagram.java:152)
         at oracle.diagram.dif.Diagram.createGraphic(Diagram.java:141)
         at oracle.modeler.dif.ModelerGraphicBridge.getGrapher(ModelerGraphicBridge.java:426)
         at oracle.modeler.dif.ModelerGraphicBridge.getGrapher(ModelerGraphicBridge.java:367)
         at oracle.modeler.addin.ModelerNode.findOrCreateManager(ModelerNode.java:252)
         at oracle.modeler.addin.ModelerDiagram.findOrCreateGraphSystemFromContext(ModelerDiagram.java:358)
         at oracle.diagram.framework.editor.CommonDiagram.open(CommonDiagram.java:231)
         at oracle.modeler.addin.ModelerDiagram.open(ModelerDiagram.java:111)
         at oracle.diagram.framework.editor.IdeDiagramEditor.openDiagram(IdeDiagramEditor.java:323)
         at oracle.diagram.framework.editor.IdeDiagramEditor.openImpl(IdeDiagramEditor.java:273)
         at oracle.modeler.addin.ModelerEditor.openImpl(ModelerEditor.java:79)
         at oracle.ide.editor.AsynchronousEditor.contextAvailable(AsynchronousEditor.java:427)
         at oracle.ide.editor.AsynchronousEditor.updateContextImpl(AsynchronousEditor.java:411)
         at oracle.ide.editor.AsynchronousEditor.setDelayedContext(AsynchronousEditor.java:395)
         at oracle.ide.editor.AsynchronousEditor$3$1.run(AsynchronousEditor.java:362)
         at oracle.bali.ewt.util.PaintUtils.invokeAfterRepaint(PaintUtils.java:53)
         at oracle.javatools.util.SwingUtils.invokeAfterRepaint(SwingUtils.java:607)
         at oracle.ide.editor.AsynchronousEditor$7.run(AsynchronousEditor.java:563)
         at java.awt.event.InvocationEvent.dispatch(InvocationEvent.java:209)
         at java.awt.EventQueue.dispatchEventImpl(EventQueue.java:642)
         at java.awt.EventQueue.access$000(EventQueue.java:85)
         at java.awt.EventQueue$1.run(EventQueue.java:603)
         at java.awt.EventQueue$1.run(EventQueue.java:601)
         at java.security.AccessController.doPrivileged(Native Method)
         at java.security.AccessControlContext$1.doIntersectionPrivilege(AccessControlContext.java:87)
         at java.awt.EventQueue.dispatchEvent(EventQueue.java:612)
         at oracle.javatools.internal.ui.EventQueueWrapper._dispatchEvent(EventQueueWrapper.java:169)
         at oracle.javatools.internal.ui.EventQueueWrapper.dispatchEvent(EventQueueWrapper.java:151)
         at java.awt.EventDispatchThread.pumpOneEventForFilters(EventDispatchThread.java:269)
         at java.awt.EventDispatchThread.pumpEventsForFilter(EventDispatchThread.java:184)
         at java.awt.EventDispatchThread.pumpEventsForHierarchy(EventDispatchThread.java:174)
         at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:169)
         at java.awt.EventDispatchThread.pumpEvents(EventDispatchThread.java:161)
         at java.awt.EventDispatchThread.run(EventDispatchThread.java:122)
    Thanks

    User,
    As you did not give any other information other then the stack trace it's heard to help. Does this error show a dialog box which asks you if want to save your work and exit or save and continue?
    Where was the ER diagram created?
    Timo
    Edited by: Timo Hahn on 20.05.2012 17:10

  • STMS: RFC error: Error when opening an RFC connection

    Hello ,
    I was wondering if you could help me with this TMS issue.
    The transport system is not working properly.
    The fallowing error is shown:
    Could not start transport control program tp
    RFC error: Error when opening an RFC connection
    There was an attempt to start the transport control program tp using the local RFC interface. An error occurred here.
      Error code: 3
      RFC error text: Error when opening an RFC connection
    Meaning of the error codes:
      03  RFC system failure
      04  RFC communication failure
    System Response
    The function terminates. Details about the error can be found in the trace file of the Gateway Monitor (SMGW).
    Procedure
    Contact your system administrator or use report RSTPTEST to localize the error. You can then execute the command again.
    When I test the tp tools:
    tp Call and RFC Ping: Error when opening an RFC connection
    Another thing would be that when testing the RFC connection CALLTP_Linux I have the error:
    ERROR: user XXX  is not authorized to start TP /usr/sap/SID/DVEBMGS53/exe
    And I have to say that the user has maximum authorizations.
    I also checked the permissions of the tp at OS level but everything seems to be ok.
    Can you help me with this?
    BR,
    Manoliv

    Dear Manoliv,
    Firstly please check if you have enough space in /usr/sap/trans file system.
    If OK, please run RSTPTEST report from SE38 and check the log file in SMGW => Goto => Trace => Gateways => Display file
    and paste the log here.
    Also, I assume filesystem permissions are OK.
    Regards,
    Sujit.

  • FM GUI_UPLOAD gives PC036 "Error when opening the download file".

    Dear all
    I'm having a problem with a particular PC.
    A program which calls FM GUI_UPLOAD gives the error PC036 "Error when opening the download file".
    The file we are trying to upload is a text file, with tab delimiter.
    If the same user executes the same program from another PCs, it works fine.
    If another user executes the program in the "problematic" PC, it gives the error.
    So, the problem is PC-related.
    I checked SAP GUI Codepage, and was the same as other PCs.
    I cheched regional configuration, and was also the same as other PCs.
    The operating  system is Windows XP, and the SAP GUI version is 7.10,  File version 7100.2.7.3077, Build 967944 , Patch level 7.
    SAP version is ECC6.
    I searched across forums, SAP note, and the web, but I couldn't find anything.
    I would be grateful if someone could give me ideas.
    Thanks in advance
    Jordi

    Hello. The user accounts are have same privilegies (like both are "Power users")? Also the file system are the same in both PC NTFS or FAT32 (today i'm find FAT32 in enterprise ) If NTFS may be some Domain politics are not allow to save file correctly, or space are not enough....Try check this first...Regards.

  • WORKLOAD ANALYSIS (INTROSCOPE DATA) - Error when opening an RFC connection

    Hi all SDNers,
    Help is needed on error "WORKLOAD ANALYSIS (INTROSCOPE DATA) - Error when opening an RFC connection".
    This error occured on RCA -> Extractor FWK administration and go to managed system (PI) and from the log, i can see some extraction failed due to error message " Error when opening an RFC connection"
    consequently, JAVA performance data is not appearing in RCA -> workload analysis but work fine for ABAP and adapter engine.
    I've followed below notes and perform the troubleshooting step by step by still to no avail:
    Note 1332428 - Missing data in service sessions from BI/CCDB
    Note 1257308 - FAQ: Using EarlyWatch Alert
    Note 1274287 - End-to-End Diagnostics 7.0 EHP1 SP18 to SP27
    Note 1265070 - Diagnostics - Setup of Managed Systems
    Note 1010428 - End-to-End Diagnostics
    http://wiki.sdn.sap.com/wiki/display/SMSETUP/WorkloadAnalysis-Noapplicabledatafound
    steps that have performed:
    restarted agent
    enlarge RFC resource cap for solmandiag and none
    delete entire SID in SMSY and pull again from SLD, re-setup managed system
    restart PI system
    i've spent 2 days on troubleshooting this issue but lack of information in SMP and SDN, even in google.
    in table E2E_EFWK_STATUS and extractor E2E_JAVA_EXTRACTOR_IF, i see all WLI_ID ended with RC 96, MESSAGE = Error when  opening an RFC connection and LASTRECORDS = 0
    I strongly believe this is the issue that causing no applicable data found for JAVA data.
    fyi, we are on SOLMAN EHP1 SPS27.
    Any kind advise is most welcome.
    Thanks,
    Nicholas Chang

    Gosh! at last i found the solution!!
    I appreciate those who tried to help and i''m sharing the solution as i believe this is the purpose of SDN Forum and help others Netweaver Chap who facing the same problem:
    Problem faced:
    Extractor failed intermittently for WORKLOAD ANALYSIS (Introscope Data) due to error message "Error when opening an RFC connection"
    Due to the above error, performance data is not available in RCA workload analysis for J2EE engine.
    Possible Solution:
    1) Ensure both webadmin & SOLMANDIAG RFC working fine -> SM59 -> TCP/IP
    2) go to SE16 -> E2E_RESOURCES and change the resourcecap to 10 for SOLMANDIAG
    3) go to /smd/services -> Diagnostic System -> Advanced Setup -> Abap connectivity -> Connection Configuration and change server count to 10
    4) Restart webadmin (step 3 & 4 can perform in VA too)
    5) set gw/keepalive &  gw/reg_keepalive to value 0 in RZ11 (without reboot of instance)
    5) again go to SM59 -> TCP/IP -> SOLMANDIAG and put in the gateway host and gateway service correctly, don't leave this empty!!!! -
    > This is the main solution to solve intermittent failed RFC for extractor.
    Now, go back and monitor the extractor log and you should see no RFC error anymore and wait for 1 hour for the data to populate.
    Thanks!
    Nicholas Chang,

Maybe you are looking for