hi alll,
   I am working with BI.In that i am getting the following  error while scheduling
     "Job terminated in source system --> Request set to red"     
no other error messages are displayed.any one know the reason why i am getting like this plz post reply..
thanks in advance
Naga

Hi,
The job has been been terminated in the source system.
Go to the source system sm37 and see the cancelled job list for the user name remote user name, 
when we run an infopackage in the bw it will trigger a collection job in the source sytem so that collection job has been terminted in the source sytem
kindly c the job log and also the short dumps in st22.
Kindly tel us the message in that short dump r reason for cancellation int he job log
so that we can comment on that
Hope this helps
Janardhan Kumar

Similar Messages

  • ERROR with Source System in BI

    Hi,
    I replicated the datasources from DEV to BI. They replicated just fine. I can even see it in BI. I then tried to activate the datasource (i created the datasource from a view ) but it gave me a run time error :
    ASSIGN_LENGTH_0 Short dump has not been completely restored..too big.
    I then tried to go into the source system and tried to activate that and it said:
    Source System DEV300 is inactive
    BI Unknown in system
    BI IDoc type ZSBC019 is not the same as source system IDoc type
    The following errors occured in the source syaytem:
    Entry in inbound table not found
    Entry in outbound table not found
    Result of the destination check: No authorization to logon as trusted system
    What could have went wrong?
    Thanks

    Did you try activating the source system in RSA1 ..right click and choose active.
    if this doesnt work then you might want to check the inbound and outbound entries in we20 transaction code for the source system. If you have authorization. Or you need to check with your BASIS to set that up for you.

  • Delta Loads failling after system copy with error in source system(RSM340)

    Hi Guru's
    We recently performed system copy in BI side.I am facing same issue in couple of chains.Process chains are failing at delta loads with error in source system(ERROR IN SOURCE SYSTEM-message no-RSM340 ).When I go for repeat option ,delta loads are running fine.I did some research regarding RSM340 and I found note:1576331.
    But my system is not showing any 'Time Inconsistencies'.So.I was not able to find any clue about it.
    Could anybody help  me out in this aspect.
    Thanks!!!
    Kuldeep

    Hi,
    Check whether the profiles that ran in background have the following authorizations.
      The RFC user on BW, receiving data from OLTP system, should have  S_BI-WHM_RFC and S_RS_ALL in the user profile.
    The RFC user on OLTP, receiving request from BW system, should have  S_BI-WX_RFC, S_IDOC_ALL, and, B_ALE_ALL in the user profile.
    Regards .

  • Error deleting source system with error message: "incorrect input for....."

    Hi,
    I'm trying to delete the source system using tcode RSA1 => Source systems => select the 'source system' and delete, but I got an error message as follows:
    "incorrect input for activating transported shadow IPacks"
    Fyi, I have opened up the client configuration (SCC4) prior to delete this source system but the source system still cannot be deleted and I receive the above error message.
    Please let me know what is the caused of the error and how to solve the problem.
    Thanks for your kind help.
    Regards,
    Mark

    Hi Mark,
    Which version of BW are you in?
    check this thread and also the note 709581
    Error Deleting Source system connection
    Thanks,
    Raj

  • Error in source system in BI 7.0...

    Hi,
         When creating a source system in Bi 7.0, when i am going to t code- rsa1- client-right click and then check,it's giving an error like:
    EDI-  partner profile not available and then detail for this error is-- a partner profile cannot be found with this key- /DBICLNT300/LS
    THIS INVLOVES THE KEY FIELD OF THE TABLE EDPP1-
    PARNUM-PARTNER NUMBER
    PARTYP-PARTNER TYPE
    Please help me in solving this. Thank You.

    Hello,
    Try a restore on your source system (rightclick -> restore) This way idoc ports and agreements are regenerated between BW and R/3. If this does not solve the problem ceck this:
    Hi,
    Did you do a system copy for BW ?
    Try a restore (rightclick on your source system) in most cases this will solve the problem.
    If not check the notes below:
    184322 Procedure after DB copy of BW source systems
    886102 System Landscape Copy for SAP BW 2.X, 3.X and NW2004s BI
    325470 Activities after client copy in BW source systems
    325525 Copying and renaming systems in a BW environment
    184754 Procedure after BW database copy
    184447 Building a BW-system landscape
    184971 Notes on BW source system connections
    140276 Error in source system assignment
    524554 Storing destinations in the BW environment
    538052 Maintenance of Myself destination in BW
    Regards, Patrick Rieken

  • "Error in source system" while creating source system

    Hello,
    I don't know what's our general problem (I suppose that it's ageneral problem) but we always have the following eror while creating a source system:
    When we want to create a source system on BI, we first get an error "No connection to source system possible". After checking the RFC connection and correct the password of the remote user on the automatically created _DIALOG RFC connection the exception changes to "Error in source system".
    The error occurs after the information "Please log on as an administrator in the following screen".
    The remote user on R/3 side has got profiles S_BI-WHM_RFC and S_BI-WX_RFC (found two conflicting statements regarding this profiles), on BI side it has got SAP_ALL and some more profiles
    What else could be the problem?
    Greetings & Thanks
    Bettina

    Hello,
    now we know that
    1. the remote user needs profiles SAP_ALL and SAP_NEW and has to be dialog user with a password unequal that password it should have in the future (otherwise you don't see the error messages that appear during the login process)
    2. the system has to be changeable (scc4 and se03)
    After the source system is created the changeability can be changed to the original values and the remote user can be changed to a communication user again.
    Thanks for the tip regarding the authorizations.
    Greetings
    Bettina

  • Error in Source System, Time series does not exist

    Hi Guys,
    I am loading the data from APO system and i am getting the below error after scheduling the info Packs.. can you analyze and let me know your suggestions
    Error Message : Time series does not exist,
    Error in Source System
    I have pasted the ststus message below
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.
    Procedure
    How you remove the error depends on the error message.
    Note
    If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the request.
    Thanks,
    YJ

    Hi,
    You better search for the notes with the message ""Time series does not exist". You will get nearly 18 notes. Go through each note and see the relevence to your problem and do the needful as it is mentioned in the note .
    Few notes are:
    528028,542946,367951,391403,362386.
    With rgds,
    Anil Kumar Sharma .P

  • Error while source system creation/Source system transport

    Hi,
         In our BW implementation, the system landscape is only 2 servers. One is BW Dev, another is BW Prd. All configurations are done in BW Dev and I extracted the data from QAS for this BW Dev system.
         Since we can’t create the source systems in the BW Production system, I tried to create the source system for the SAP R3 Production system in BW Dev and trying to transport this to BW Production Instance.
         I have two queries.
    1.  Is this way is correct for creating the Source System for BW Production system?
    2. When I tried to activate the source system I am getting the following error messages. (I tested the RFC Destinations. There is no problem, I also done the configurations for logical system creation and client assignment in both the systems).
    Error in source system GWPCLNT900
         Message no. RSAR502
    Diagnosis
         With Remote Function Call to system GWPCLNT900 error connection closed
         (no data)  ccurred.
    Procedure
         Remove the cause of the error.
    When tried again I got the following error message
    Basic type ZSBB030 doesn’t exist. EA 447
    Result of the destination check: Timeout RSAR 375.
    Could anyone throw some light on these errors?
    Thanks in advance.
    Krishna

    Hi,
    you need to maintain the logical systems on both R/3 and BW. You also need to set up the RFC connection with users that can log in to the other system. The R/3 system must be open for customizing in scc4.
    In transaction se03 the system change options for 'Business Information Warehouse: SAP Namespace' and 'Business Information Warehouse: Customer Namespace' may need to be modifiable. I am not completely sure about this.
    The last thing I will mention is that I have seen source system creation fail when the RFC-users are system users, and the source system creation worked if the RFC-users was display user while creating the source system. The RFC-users must be changed back to system user later...
    Please look at best practice documents on a more step-by-step guide...
    Best regards,
    Christian Frier

  • Urgent Help! Errors in source system(RSM     340)

    Need urgent help. Issue in production.
    I added fields to the COPA datasource, by changing the operating concern. I recreated the datasource with the same name replicated into BW & ran delta again. The whole procedure worked fine in Dev & Quality but in production it gives me the below error. I thought its a delta issue so I deleted the data & try reload but still same issue. Below is the error. I checked the connection with R3. its an ok. All other loads work fine. Before deleting delta, it gives below error & when you rerun, it finishes with zero records. I also tried activating update, transfer & ods & cube in BW. I also asked functional guy to check operating concern & its active. kindly help
    Errors in source system     RSM     340
    Error message from the source system
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.

    Hi PK,
    caller 09 error mainly because of source(target system) and destination(bw system) not configured correctly.
    i think you get the error message as follows. file is in the client workstation as like.
    better you contact basis people. they will resolve this.
    hope this help you
    Regards
    Harikrishna N

  • Time series does not exist, Error in Source System

    Hi friends,
    I am loading the data from APO system and i am getting the below error after scheduling the info Packs.. can you analyze and let me know your suggestions
    Error Message : Time series does not exist,
                             Error in Source System
    I have pasted the ststus message below
    Diagnosis
    An error occurred in the source system.
    System Response
    Caller 09 contains an error message.
    Further analysis:
    The error occurred in Extractor .
    Refer to the error message.
    Procedure
    How you remove the error depends on the error message.
    Note
    If the source system is a Client Workstation, then it is possible that the file that you wanted to load was being edited at the time of the data request. Make sure that the file is in the specified directory, that it is not being processed at the moment, and restart the request.
    Thanks,
    YJ

    Hi,
    You better search for the notes with the message ""Time series does not exist". You will get nearly 18 notes. Go through each note and see the relevence to your problem and do the needful as it is mentioned in the note .
    Few notes are:
    528028,542946,367951,391403,362386.
    With rgds,
    Anil Kumar Sharma .P

  • Error in the Data Selection - Errors in Source System RSM 340

    Hey Everyone,
    I'm having an issue with loading a Delta for 0MAT_PLANT_ATTR.  This is the second night it has happened, where I get the error "Error in the Data Selection".  This error happens in the EXTRACTION part of the Monitor.  And, we cannot run another Delta to see if it'll work, we have to delete the old Delta Init, and run a new one.  The other error is "Errors in Source System - RSM340".  That's as much it gives.
    Could anyone suggest why this would be happening?  I checked RSA3 in R/3, and no errors on the extraction.  I also checked sm37 against the job that loads that data, and it completed successfully.  I honestly don't think there's an issue with the data.  We cannot have this happen often, and I just need to know if this is something that can be corrected.
    Thanks,
    John

    There is nothing wrong with the TID's or anything like that.  There is also no selection criteria in the infopackage.
    When the Delta fails, the error occurs under EXTRACTION in the monitor.  It seems to be successful under TRANSFER and PROCESSING in the monitor, which I find strange.  Also, I run a new Delta Init with Data Transfer, and that works just fine.
    So, I'm not sure what it could be?

  • Failure of infopackage step in process chain - Error in source system.

    Hello Experts,
    We are experiencing this during the execution of process chain.
    All the step for data loads within BW(DSO to DSO, DSO to cube) are failing with error -
    - Error in source system
    - Error during data selection
    Please note that we are 3.5 data flow and thus, data load within BW is through emulated data source and the infopackage. Steps running such  infopackages for emulated data source are failing in process chain with error above.
    Surprisingly, when I run the infopackage manually out of process chain it runs successful without any error. But when I run through process chain it fails.
    Any clue or suggestion? We have already tried doing re-initialization for infopackage.
    Appreciate your inputs.
    Regards,
    PK.

    Hi,
    When we run data loads thru process chain it will run in background. as per the available background application servers your request will be processed.
    as my your during your load time server will be on high load.
    please check your system busy schedule and schedule your process chains.
    Check Tx - SM50, if you have less application servers, then ask basis to create few more to application servers to process the request at busiest time.
    check about increasing parallel processing and default data transfer settings.
    go to info package---> menu scheduler--> data settings for default data transfer.
    Thanks

  • Errors in source system

    Hi  Friends,
                      I got an failure with a data load... The data was loading into ODS from r/3. The data source name 2lis_03_bf... I got an error like this in status Tab -
    <b>Error message from the source system</b>
    <b>Diagnosis</b>
    An error occurred in the source system.
    <b>System response</b>
    An error occurred in Extractor .
    Check the error message.
    Procedure
    The procedure for removing errors takes place depending on
    <b>the error message:</b>
    Note
    If the source system is a Client Workstation, then it is possible that the file that was to be loaded was being edited at the time of the data request. Make sure that the file is in the specified directory and is not being edited, and restart the request.
    And when we click on the error message push button... we are having the following errors : -
    <u><b>Message Type </b></u>    <u><b>Message Class</b></u>   <u><b>Message Class </b></u>
    Errors in source system                                             RSM         340
    Queue 2LIS_03_BF is not available in the source system      RSQU         9
    Activation of data records from ODS object terminated             RSM1       102     
    Answering Getz appreciated,
    Thanks & Regardz,
    <i><b>Aluri</b></i>

    Hi,
    On BW go to SE16. Look at RSSDLINIT table. Match up the LOGSYS with your OLTPSOURCE (for the infopackage that is causing the problem).
    Delete that line
    Now you can open the infopackage. (be sure to delete the initialization) before you run the info pack again.)
    Regards
    Srini

  • Get Error in source system when loading flatfile from application server

    Hi
    I'm loading data from flatfiles on the application server. In the datasource if I display the sample data. It shows fine.
    But when I execute the infopackage I get an error when it is loading the data to PSA.
    The error is
    Error in source system
    Message no. RSM340
    There is no further information
    But if I load from my machine it works fine.
    Any help will be great

    Hi,
    As you can view display the sample data. It shows fine.
    It mean there is no issues in BW (File path is correct, Data in Flat file is correct).
    Then definetely its with the source system, which is resisting to pass IDOC to BW.
    Now.we need to know the its problem with File on App serv or App serv itself?
    Just check trying to Load another  Flatfile in App serv.
    Let me know.
    Regards
    Hari

  • Delta loading master data errors in source system Message RSM340 quality

    Hi,
    I'm trying to load with delta  master data for standard data sources.
    In dev, everything seems fine.
    I' ve transported the same elements to QA. I've done init, it is ok. I do delta, I get red status: Errors in source system, message no. RSM340. I've tried to put my delta on green, I've remade my init, I've reloading with delta, and I get the same problem.
    I have this problem for all master data loading.
    Should I install some infoobject from Bi Content?
    Thanks a lot !

    Hi,
    Check following threads
    [3003 + R3299 + RSM340] error messages loading an ODS
    Extraction failed with error Message no. RSM340
    BW Data Loading - Delta Processes
    Thanks and regards
    Kiran

Maybe you are looking for

  • Blue bounding box - Can't Remove

    www.cfhda.com/menu.html In Firefox and Navigfator, but "not Safari or Explore," there is a blue bounding box around a link (pricing) at the bottom. It shows up in the DW doc, but I can't get rid of it. The link is a png in a table cell but there are

  • No hardware acceleration

    I now have Dx Diag reporting that my Sb Fatalty XFi does not support hardware sound acceleration. The card is also not being seen as an XFi by Fear and Fear expansion pack! The XFi setup choices are greyed out! All this since running the autoupdate w

  • Mac mini dilemma! Dont know which to buy..

    I was wondering what you guys think, i am thinking of getting a mac mini to use as a "media center" sorta pc because their small quite and the software seems to be alot more stable then vista. I saw one on amazon for $450 that has a 1.66 core duo pro

  • Scroll bar not appeared

    Hello, I used the following command to view documents and scroll to view contents: window.open("\\server\doc\example.doc","","Width=780,Height=520,help=yes,border=thin,status=no,toolbar=no;menubar=no;scrollbar=yes;scrolling=yes"); There is no problem

  • I bought photoshop elements, the serial number comes up as invalid. I know its right. .what do i do?

    I am having trouble installing Photoshop Elements 12.  I get to the screen where I can input my serial number and it says it is invalid.  in fact the number on the box and the receipt which also has the serial number on it match perfectly but they se