Error with Technichal System Definition

Hi Everybody,
I've got like 20 systems connected to solman 7.1 sp10. All of them with their diagnostic agent and wily, all the wizards are green and everything looks good except for the "System Status" in solman_workcenter which is red. On the details i got the following error.
'DES~ABAP': Cannot get Technical System from ICM 'DES~ABAP~~ICM'
I haven't been able to find any log concerning to the error or anything that helps me to solve it.
Does anyone knows why is this happening or anoyone who have had this error?
Thanks in advance.
Rafael.

Hi
I know this thread here is some month old, But there might be others out there having the same problem, as I had. But I found the solution and here is what worked for me.
I opened the LMDB for this system, picked the line Technical instances in the navigation tree. I secured that the field" Technical Instance name" in the Section "Application Server ABAP"  was correct . Then I filled in the port informations for the icm/server_port_0 in the HTTP Port section. This was empty in my situation.  I compared with one of the other systems that were working.
The HTTP Port name I set to: icm/server_port_0 and the URL to HTTP://<hostname>:80<instno>
After this was saved the error was gone,
I also first checked that there was this entry in the instance profile
icm/server_port_0 = PROT=HTTP,PORT=80$$,TIMEOUT=600,PROCTIMEOUT=600
I was there, but I thing this will be a prerequisite for this to work.
Regards
Fritz Baunsgaard

Similar Messages

  • Communication error with external system ( VERTEX )

    Hi Folks,
    While creation the Credit memo request or Sales order /invoice system giving the error message " COmmunication error with external system ( VERTEX ) " and stopping to proceed further and even not able to post the accounting document.
    Please help  me out here.
    Answers will be appreciated and rewared.
    Regards,
    Ram.

    Hi,
    check this below thread
    Communication error with the external tax system (VERTEX_MS0018)
    OR
    Remove V from the Extrernal System at the location IMG->financial Accounting->Financial Accounting Global Settings->Tax on Sales/Purchases->Basic Settings->External Tax Calculation->Activate External Tax Calculation
    Reg,
    JJ
    Edited by: Jagsap on Mar 5, 2010 1:15 PM

  • Error with Logical System - Long SID - SOLAR01

    Hello,
    We are using Solman Ehp1, stack 25.  We have a problem in using Long SID (same SID) in Solar01
    We are creating a new system in the landscape of a project.  There was a copy of production system (called PCA) into a sandbox system keeping the same SID for both system PCA
    We define a new product system in SMSY and we use a new long SID so that it is called PCAP.  This new system recovered the logical system definition for each client which is the same for both PCA and PCAP system.  Then we create RFCs for the new PCAP long id, no problem.
    Finally we add the new system to the Logical Component Z_ERP with a new role 2 Sandbox system.
    We went to the project SOLAR_PROJECT_ADMIN and assign the new system role 2 so that is available to use it in some test.
    We go to transaction SOLAR01, switch to the new system role 2, and try to execute any transaction in the new server, it is saying that there is no logical system assigned to PCAP.... which is true, since the logical system is called PCAxxxxx.
    Can you help us with that?
    Regards
    Esteban Hartzstein

    Hello Fabricius,
    What I did is add the new PCAP system to the current Logical Component with the new system role Sandbox test  so that they can perfomed some tests on that role.  This system is a complete copy of the original PCA system, so internally everything is PCAP, and since I cannot have same SID in SMSY, I created as PCAP.  And that causes a problem with the Logical System definition.
    The actual error message is
    smsy_ppms_api044
    This error message was reported in another post back in 2009
    LIink: Error getting RFC destination for logical system SMD XXX
    Any ideas?? Help required
    Regards
    Esteban
    Edited by: Esteban Hartzstein on Oct 27, 2011 10:00 AM

  • ERROR with Source System in BI

    Hi,
    I replicated the datasources from DEV to BI. They replicated just fine. I can even see it in BI. I then tried to activate the datasource (i created the datasource from a view ) but it gave me a run time error :
    ASSIGN_LENGTH_0 Short dump has not been completely restored..too big.
    I then tried to go into the source system and tried to activate that and it said:
    Source System DEV300 is inactive
    BI Unknown in system
    BI IDoc type ZSBC019 is not the same as source system IDoc type
    The following errors occured in the source syaytem:
    Entry in inbound table not found
    Entry in outbound table not found
    Result of the destination check: No authorization to logon as trusted system
    What could have went wrong?
    Thanks

    Did you try activating the source system in RSA1 ..right click and choose active.
    if this doesnt work then you might want to check the inbound and outbound entries in we20 transaction code for the source system. If you have authorization. Or you need to check with your BASIS to set that up for you.

  • Error with Transport system not configured that may be related to CHaRM

    Who has in depth knowledge on setting up SAP Solution Manager CHaRM. Had an odd problem with the transport system failing when the QA system was shut down for maintenance. Transports were not able to be created or save to.  Error message was Transport System not configured.  Brought up QA and re-distributed system and Transport group and transport requests started working again.

    Hello,
    if a system, e.g. QA system, will not be available due to a maintenance task,
    we set the status of this system to "temporarily inactive" (see header data in transaction SMSY).
    This status allows us, to create new transport requests in DEV-System although consolidation system QA is not available.
    (Of course you have to reset the status, when QA-system ist started again.)
    Hint: it is not possible to release or to import a transport request, when consolidation system is shut down.
    Therefore the developer should pay attention to the messages, which raise in urgent corrections.
    best regards
    Horst

  • Error with "File System" destination only in a Publication

    Hello,
    I am able to have individual reports run & refresh to a File System destination, but when I attempt to have the same reports, as part of a Publication, save to a File System destination, I receive this error in the log:
    ERROR PublishingService:HandlerPool-32 BusinessObjects_PublicationAdminLog_Instance_15516 - Publication ID # 15516 - Distribution to destination CrystalEnterprise.DiskUnmanaged ... destination DLL disabled. [http://CrystalEnterprise.DiskUnmanaged ([1]/1])]: [ (FBE60013)
    If I use Email instead of File System in this Publication, the Publication runs fine, no issues.
    Thanks for any help.

    Let's start with proper terminology
    You're not sending report to unmanaged disk, you're scheduling it there.
    When you use publication - you're publising it there.
    2 different worflows, that use 2 different servers. Each server has to be configured for this functionality.
    It is done in CMC in servers properties.
    Admin guide will give you information on what each server in BO architecture is responcible for and what are the parameters that needs to be set for various workflows.

  • Error  with source system

    hi alll,
       I am working with BI.In that i am getting the following  error while scheduling
         "Job terminated in source system --> Request set to red"     
    no other error messages are displayed.any one know the reason why i am getting like this plz post reply..
    thanks in advance
    Naga

    Hi,
    The job has been been terminated in the source system.
    Go to the source system sm37 and see the cancelled job list for the user name remote user name, 
    when we run an infopackage in the bw it will trigger a collection job in the source sytem so that collection job has been terminted in the source sytem
    kindly c the job log and also the short dumps in st22.
    Kindly tel us the message in that short dump r reason for cancellation int he job log
    so that we can comment on that
    Hope this helps
    Janardhan Kumar

  • OVM Manager 2.2.2: server pool error with file system type

    I'm just getting started with OVM. I've installed OVM on one machine and the manager on another.
    I created a server pool, which seemed to work OK but shows "Error" in the table under the "Server Pools" tab in the manager interface
    When I edit it I see
    Error: OVM-1011 OVM Manager communication with NNN.NNN.NN.NNN for operation Pre-check cluster root for Server Pool failed: <Exception: SR '/dev/sda3' not supported: type 'ocfs2.local' not in ['nfs', 'ocfs2.cluster']>
    Can anyone explain this? Does this mean I can't use a local file system in OVM 2.2.2? I understood this was the case with OVM 3, which is why I went with 2.2.2.
    Thanks.

    Roger Ford wrote:
    Error: OVM-1011 OVM Manager communication with NNN.NNN.NN.NNN for operation Pre-check cluster root for Server Pool failed: <Exception: SR '/dev/sda3' not supported: type 'ocfs2.local' not in ['nfs', 'ocfs2.cluster']>
    Can anyone explain this? Does this mean I can't use a local file system in OVM 2.2.2? I understood this was the case with OVM 3, which is why I went with 2.2.2.You can't created a clustered pool with a local filesystem. You need to format the filesystem with ocfs2 in clustered mode.

  • Execute C# in PowerShell: errors with " using System.XML "

    Hi , I'm trying to execute C# code in Power Shell 2.0 .
    My problem is for the references  at the beginning of the code:
    $code = @"
    using System;
    using System.Collections;
    using System.IO;
    using System.Linq;
    using System.Xml;
    using System.Xml.Linq;
       public class Program
            static void Main()
            {  /* the code wich works*/
    Add-Type  -TypeDefinition $code -Language "CSharpVersion3"
    Powershell give me an error saying that " The type or namespace Linq doesn't exist" , and the same for Xml. I have Visual studio express 2013 .
    How can add or import correctly those references? or what is my error?

    Hi Rebegg,
    As this issue is related to Visual Studio, I suggest you create a new thread on Visual Studio forum, more experts will assist you with this issue.
    Visual Studio forum:
    http://social.msdn.microsoft.com/Forums/en-US/home?category=visualstudio
    In addition, about this issue, you have to add your  assemblies to your PowerShellsession before you can reference them to you C# Code, you can use the script like:
    $Assem = (
    ...add referenced assemblies here...
    $Source = @"
    ...add C# source code here...
    Add-Type -ReferencedAssemblies $Assem -TypeDefinition $Source -Language CSharp
    Here are some similar posts for your reference:
    http://ruudvanderlinden.com/2010/10/19/running-inline-c-with-custom-assemblies-in-powershell-2-0/
    http://powershell.com/cs/media/p/133.aspx
    http://blogs.technet.com/b/stefan_gossner/archive/2010/05/07/using-csharp-c-code-in-powershell-scripts.aspx
    I hope this helps.
    Thanks,
    Wendy
    Wendy Li
    TechNet Community Support

  • Error with Business systems

    Hi Gurus,
    I created the SC, for that SC i created the TS,BS.
    I finished all things in IR, tested it, working fine.
    In ID which 'Assisgning Business system' i am not get any BS in the list.
    will u plz guide me in this.
    Thanks & Regards,
    Lakshmi..

    lashmi,
    you need to import  the business system from SLD into ID.Right click on Buiness System in ID it will get assign business system option from that select next unitl you slect BS and choose the BS you created in SLD and import it.

  • Tips for blue screen (BSOD) errors with Windows Vista and Intel Turbo Memory on T61/T61p

    Important note: The symptoms and solutions described below address only a small subset of the possible causes for blue screen errors, aka BSOD. This information can help address blue screen errors specifically related to Turbo Memory, but may not solve errors related to other issues. Please read through the instructions completely, make sure they apply to your system, and after attempting the solutions please post back with your feedback for the community.
    Some users may experience random blue screen errors with ThinkPad
    systems running Windows Vista with Intel Turbo Memory hardware. These
    blue screens may occur during normal usage on the system or they may
    occur when booting into Windows Vista. Blue screens related to the
    Intel Turbo Memory hardware may reference a stop code of 8086 with
    memory address locations of {0, 0, 0, 0}.
    There are two main steps that you can take to help resolve blue screen issues related to Intel Turbo Memory.
    Step 1: Update Intel Turbo Memory Driver
    If the driver version is before version 1.0.1.1004-7.0.3.1001, please
    update to this version.
    To determine what version of the Intel Turbo Memory driver is installed:
    1.    Click Start, then click Control Panel.
    2.    Click System and Maintenance.
    3.    Click System.
    4.    Click Device Manager.
    5.    Expand the Storage controllers category.
    6.    Double-click Intel Flash Cache Logic Chip.
    7.    Click the Driver tab. Then you will see the driver version (for example, 1.0.1.1004).
    The new driver and installation instructions can be found here.
    Note: The Intel Matrix Storage Driver is updated with this package.
    Step 2: BIOS version
    If your BIOS version is older than those listed below, please update to the version listed.
    How to check your BIOS version:
    Turn off the system.
    Turn on the system.
    While the To interrupt normal startup, press the blue ThinkVantage button message is displayed at the lower-left area of the screen, press the F1 key.
    The
    BIOS Setup Utility menu will be displayed. If you have set a supervisor
    password, the BIOS Setup Utility menu appears after you enter the
    password.
    Check BIOS Version and Embedded Controller Version.
    Turn off the system.
    System BIOS versions:
    ThinkPad T61/T61p (14.1 inch widescreen with IEEE 1394 model) - BIOS version 1.22 (7LET52WW)
    Please
    remember that these updates do not solve every possible system blue
    screen, but they do resolve several problems related to the Intel Turbo
    Memory driver.
    Message Edited by Tim_Lenovo on 11-30-2007 07:03 PM
    Tim Supples
    Lenovo Social Media
    Got a question? Don't PM me, post it on the forum!
    Lenovo Blogs
    X60 Tablet SXGA+ primary, Z61p fully loaded workhorse

    Thanks Tim,
    I do have my T61p fully up-to-date to the latest drivers and updates (via System Update and the Drivers&Software web page when the former is not that up-to-date).
    At the moment the most recurrent problem is this:
    http://forum.lenovo.com/lnv/board/message?board.id=T_Series_Thinkpads&thread.id=55
    which has been longly speculated here:
    http://forum.thinkpads.com/viewtopic.php?t=47755
    My other angst is the boot-time chkdsk hang-up problem:
    http://forum.thinkpads.com/viewtopic.php?t=52765&highlight=chkdsk
    I just wonder if this purely a Vista issue when using NV cache, the disk spinning down at almost exactly 1 hour from the beginning of the chdsk operation seems too much of a coincidence.
    This is my T61p configuration:
    Intel Core 2 Duo T7700 2.4GHz
    BIOS version 1.26-1.06
    4GB RAM 2 SO-DIMMs
    nVidia Quadro FX 570m with 512MB VRAM
    WUXGA LCD
    Seagate 7200.2 160 GB
    4GB RAM 2 SO-DIMMs
    Windows Vista Ultimate 32bit (waiting to move to 64bit)
    thanks,
    andrea
    Message Edited by abarbieri on 12-05-2007 03:48 PM
    T61p - 15.4" - T7700 - FX 570M 256MB - 4GB RAM - ST916023AS - 4965AGN - BT - FPR - 9 cell - Vista Ult. x86
    T21p - 14" - PIII 850MHz - S3 Savage/IX 8MB - 512MB RAM - 100GB 7200rpm - WinXP x86

  • Tips for blue screen (BSOD) errors with Windows Vista and Intel Turbo Memory on X61/X61s

    Important note: The symptoms and solutions described below address only a small subset of the possible causes for blue screen errors, aka BSOD.
    This information can help address blue screen errors specifically
    related to Turbo Memory, but may not solve errors related to other
    issues. Please read through the instructions completely, make sure they
    apply to your system, and after attempting the solutions please post
    back with your feedback for the community.
    Some users may experience random blue screen errors with ThinkPad
    systems running Windows Vista with Intel Turbo Memory hardware. These
    blue screens may occur during normal usage on the system or they may
    occur when booting into Windows Vista. Blue screens related to the
    Intel Turbo Memory hardware may reference a stop code of 8086 with
    memory address locations of {0, 0, 0, 0}.
    There are two main steps that you can take to help resolve blue screen issues related to Intel Turbo Memory.
    Step 1: Update Intel Turbo Memory Driver
    If the driver version is before version 1.0.1.1004-7.0.3.1001, please
    update to this version.
    To determine what version of the Intel Turbo Memory driver is installed:
    1.    Click Start, then click Control Panel.
    2.    Click System and Maintenance.
    3.    Click System.
    4.    Click Device Manager.
    5.    Expand the Storage controllers category.
    6.    Double-click Intel Flash Cache Logic Chip.
    7.    Click the Driver tab. Then you will see the driver version (for example, 1.0.1.1004).
    The new driver and installation instructions can be found here.
    Note: The Intel Matrix Storage Driver is updated with this package.
    Step 2: BIOS version
    If your BIOS version is older than those listed below, please update to the version listed.
    How to check your BIOS version:
    Turn off the system.
    Turn on the system.
    While the To interrupt normal startup, press the blue ThinkVantage button message is displayed at the lower-left area of the screen, press the F1 key.
    The
    BIOS Setup Utility menu will be displayed. If you have set a supervisor
    password, the BIOS Setup Utility menu appears after you enter the
    password.
    Check BIOS Version and Embedded Controller Version.
    Turn off the system.
    System BIOS versions:
    ThinkPad X61 or X61s - BIOS version 1.06 (7NET25WW)
    Please
    remember that these updates do not solve every possible system blue
    screen, but they do resolve several problems related to the Intel Turbo
    Memory driver.
    Tim Supples
    Lenovo Social Media
    Got a question? Don't PM me, post it on the forum!
    Lenovo Blogs
    X60 Tablet SXGA+ primary, Z61p fully loaded workhorse

    Dear Tim,
    First off, many thanks for the tips for resolving BSOD with Vista + Turbo Memory on X61.  I've been suffering from this BSOD for countless times since I bought in my X61 7673-CW9 in April 2008.
    Even prior to having the pleasure to visit this wonderful forum, I followed both steps as indicated, and updated my Intel Turbo Memory driver to 1.5.0.1013 and my BIOS to 7NETB4WW (2.14).  However, the BSOD recurrs.
    For the past two months, I've recovered my system to factory default settings using Rescue and Recovery for over twenty times, each time with the latest Intel Turbo Memory driver and BIOS.  Notwithstanding that, BSOD recurrs.
    During these painful experiences, I tried two options: 1) making my X61 up-to-date by using System Update and Windows Update (including Vista SP1 or excluding Vista SP1); 2) keeping my X61 the status as factory default (i.e. without updating through either System Update or Windows Update (the automatic/scheduled update function of both is turned off)).  In either case, BSOD recurrs.
    I'm 100% positive that the BSOD does not arise from any hardware or software/firmware I install.  I never install any hardware (e.g. RAM).  And, it is not caused by any software/firmware I install: the clear and unequivocal evidence is that at one time,I encountered BSOD while having restored back to factory setting and booting for the first time.
    I live in Taiwan, and I seldom heard this BSOD here.  All of my friends (as most of Taiwan residents) using X61 operate in Traditional Chinese environment, whereas I operate in English environment.  In Taiwan, when booting for the first time after purchase/recovery, the Windows Vista Business system provides for lanuage choice (Traditional Chinese or English), and, once chosen, the language cannot be altered later on (unless, of course, the system is restored back to factory default settings).
    My system specs are the same as the day I purchased it and are listed below (as I'm not sure if my machine type X61 7673-CW9 is applicable outside Taiwan):
    Processor: Intel(R) Core(TM)2 Duo CPU T8300 @ 2.4GHz
    Memory: 1.00 G.B.
    System: Windows Vista Business (32-bit)
    Hard Drive: 160 G.B. @ 7,200 r.p.m.
    And, of course, with Intel Turbo Memory 1 G.B.
    I contacted the Lenovo support staff here in Taiwan for countless times, but they seem to be clueless.  I learned that some friends at this forum downgraded their OS back to Windows XP, but I chose not to.  The reason is simple: my purchase price for X61 7673-CW9 includes the Intel Turbo Memory, which cannot function under Windows XP (at least so far).
    Therefore, I just wish to share my experience here and perhaps I can get some advice from you and other friends here.  Any advice will be tremendously and enormously appreciated.
    Kevin Chen @ Taiwan

  • Printing error with t-code j1inmis: Can not find PDL type for output device

    Hi,
    When using tr.code j1inmis,when we seeing the print preview iam getting below error.
    The error with my system show the details as follow :
    Cannot find PDL type for output device LP01.
    My system is only abap stack.Guide me for the same how to resolve this.
    Thanku

    Hi,
       When i submit the test through URL its working fine(http://192.17.0.12/AdobeDocumentServices/Config).In SM59 Both sides are working.
    When I check The Test : FP_TEST_00 iam getting below error
    ADS: com.adobe.ProcessingException: com.adobe.Processin(200101)
    But
    When I check The Test : FP_PDF_TEST_00 its working fine.
    And When I check this test : FP_CHECK_DESTINATION_SERVICE without destination its working fine.
    When i check with destination iam getting error :  SYSTEM ERROR:com.adobe.ProcessingException:Problem accessing data from Destination:dest:FP_ICF_DATA_SMN//sap/bc/fp/form/layout/FP_FORM_SECURITY_TEST.XDP?fp-language=DE.
    Guide me for the same two tests are working fine other two are getting error,guide me for the same to solve this,appreciate ur help.
    Thanku

  • Printing error  with t-code FBCJ: Can not find PDL for output device prtloc

    Hello , folks ,
    The error with my system show the details as follow :
    Cannot find PDL type for output device prtlocal
    Message no. FPRUNX113
    Diagnosis
    No PDL type has been found for the specified output device.
    System Response
    Error message
    Procedure
    Contact your system administrator.
    Procedure for System Administration
    For more information, see SAP Note 685571.
    Our Basis can not solve the problems .
    anybody know what's wrong with it ? 
    Thanks a lot .

    other problems could be:
    C drive is full
    ADS folder under C:\Temp are write protected

  • Error while executing SAP E-Commerce Application with UME system

    When attempting to login to the B2B application (http://hostname:port/b2b/init.do), we receive the following error:
    Error while executing SAP E-Commerce Application with UME system; try again to log on. If the problem persists, call our hotline.
    I checked the defaultTrace log and every time the login page is called the following messages are displayed:
    #System.err#sap.com/crm~b2b#System.err#Guest#0##n/a##70cf2ba0756b11df86050003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Error##Plain###com.sap.engine.services.servlets_jsp.server.exceptions.WebIllegalStateException: The output is committed.
    #System.err#sap.com/crm~b2b#System.err#Guest#0##n/a##70cf2ba0756b11df86050003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Error##Plain###  at com.sap.engine.services.servlets_jsp.server.runtime.RequestDispatcherImpl.forward(RequestDispatcherImpl.java:354)#
    another 40 lines of similar text
    When a login is attempted, the following messages are appended to the trace file:
    #tracing.isa.runtime#sap.com/crm~b2b#tracing.isa.runtime#Guest#0##n/a##f6384ec0756b11df81380003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Debug##Plain###[actionxecution]='begin' [actionclass]='com.sap.isa.user.action.PrepareLoginBaseAction' [path]='/preparelogin'#
    tracing.isa.runtime#sap.com/crm~b2b#tracing.isa.runtime#USER1#7439##n/a##f6384ec0756b11df81380003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Debug##Plain###[actionxecution]='end' [actionclass]='com.sap.isa.user.action.PrepareLoginBaseAction' [path]='/preparelogin' [forward]='/login.do' [exectime]='42'#
    #tracing.isa.runtime#sap.com/crm~b2b#tracing.isa.runtime#USER1#7439##n/a##f6384ec0756b11df81380003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Debug##Plain###[jcofuncionexecution]='begin' [funcname]='CRM_ISA_SSO_LOGIN_CHECKS' [ashost]='<hostname>' [sysid]='CRM'#
    #tracing.isa.runtime#sap.com/crm~b2b#tracing.isa.runtime#USER1#7439##<hostname>_CJM_678801250#USER1#f6384ec0756b11df81380003ba827311#SAPEngine_Application_Thread[impl:3]_0##0#0#Debug##Plain###[jcofunctionexecution]='end' [funcname]='CRM_ISA_SSO_LOGIN_CHECKS' [ashost]='<hostname>' [sysid]='CRM' [exectime]='12'#
    I have modified the userid and hostname in the above trace output.
    Does anyone know how we can debug this issue further?
    Thanks,
    Setu

    Hi,
    Are you using UME login type for your B2B Scenario?
    In your B2B XCM setting have you selected UME related login type?
    eCommerce Developer

Maybe you are looking for

  • Acrobat 7 stops working, asked for reinstall

    I ran Clean My Mac, and after, Acrobat and Distiller (7) refused to load, saying I should reinstall from my original CDs. Well, I didn't originally load them from CDs, but via download. How do I reinstall without resorting to CDs. (Yes, my prior back

  • Wiring for a Symbol SPT17xx RJ45 to DB9 or where to find

    I have (as I have mentioned) the Symbol SPT1700 and SPT1740 with the charging cradle. I was able to repair the charging cradle (blown input capacitor and shorted voltage regulator), but I still need a cable to connect the RJ45 on the cradle to a DB9

  • Leave

    Hi All,    We have recently migraded from 4.6 C to ECC 6.0. Previously we were using WS2000081 for leave workflow and now wee are using WS12300011 for same.    New workflow works but I'm not able to read as it does not contain the container elements

  • Workflow with IFS

    Will it be possible to handle workflow in the up and coming releases? Regards Jacq

  • JFileChooser - Thumbnail View

    Hi, I have found that the standard JFileChooser component does not support thumbnail view :( I have implemented a work around, such that the image preview can be seen on the left side when an image is selected. But, can any one guide me whether we ca