Essbase Smart view installation error

Getting error while installing the smart view on windows operating system
The error is "Please exist all microsoft office applications to proceed with the installation "
I have not opened any excel ,so donot understand whats this errir for and how to solve it.
Please help Essbase gurus .

You probably have one of the other Office applications running - remember, Office is not just Excel and Smart View works with those other applications too - and / or it's open invisibly.  If you open task manager and look at Processes you may see an instance of EXCEL.EXE (for example) even though Excel isn't visible as an application on your desktop.

Similar Messages

  • Smart View installation error with windows 7

    Hi,
    We're running into an error when trying to install Smart view client (v11.1.1.2) on Window 7 PCs (32bit, w/ Office 32bit) which states the following:
    "This installation package could not be opened. Contact the application vendor to verify that this is a valid Windows Installer package."
    We've been getting this since a recent MS security update (We want to say June's), any one else getting these or know a way around it?
    Thanks,
    James

    Hi,
    Please check the version of client installer(smart view).Is it 32 bit or not?
    Thanks
    RP

  • Essbase Smart View & Office 2007 Add-In

    Hi
    I am currently using Hyperion Essbase version 9.3.1. How do I install Smart View as I believe it comes with this version and also lso how do I install the Hyperion Add-in for Excel 2007 in the ribbon.
    Regards
    Tom

    Hi,
    Go to http://edelivery.oracle.com/
    Log in
    Hyperion Performance Management and BI
    Hyperion Performance Management and BI (9.3.1) Media Pack for Microsoft Windows (32-bit) Download
    Hyperion Smart View for Office Release 9.3.1.2 Microsoft Windows x86 Installer
    Hyperion Essbase - System 9 Release 9.3.1.3 Client Windows Installer
    They are standard executable installation files that you just double click and follow the instructions.
    If you want later 9.3.1 patch versions of the client, then log into MyOracle support
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • How I start smart view without error message?

    Hello,
    we use Oracle Smart View 11.1.2.5.215 and Office Professional Plus 2010 SP 2.
    The installation run in an AppV 4.5 SP 2 Environment.
    Smart View starts with the following error message:
    Failed to create Smart View Extension Activator object. Verifiy that it is registered properly (-2147221164)
    We have the newest .NET installation and install the excel shared features.
    Directly of the server Smart View starts correctly.
    The message just appears when Smart View starts over the NetMan Applications Link (Citrix + AppV).
    Please help!
    Thx, John

    Hello,
    now its several months ago that we post our Smart View problem.
    Till now we have no solution. The oracle support can't help us
    because we use AppV .
    Use someone else Smart View in an AppV environment?
    We want to go live soon and must handle the error message.
    Thank you for your Support

  • Smart View compile error on startup

    Hi
    Just installed the following components:
    - Windows 2008R2
    - Office 2010 x64 with SP2
    - Smart View 11.1.2.5.210 (x64)
    When I start and close Excel I get the following:
    Microsoft Visual Basic for Applications
    Compile error in hidden module: HsTBarPublic.  This error commonly occurs when code is incompatible with the version, platform, or architecture of this application.
    The same software version works fine on 32bit versions of Office 2010 + Smart View.  Any ideas for troubleshooting 64bit Applications of Office and Smart View?
    Thanks
    Anthony

    Had the same problem with conflict between CS6 (Photoshop, Premier, After Effects, etc.] and Net Nanny.  Solution was as follows:
    1. Log onto Net Nanny Admin Tools
    2. Click on Application Exceptions
    3. Click Add
    4. Browse to folder containing "dynamiclinkmanager.exe".  On my computer (Windows 7 Pro) it was located in
         C:\Program Files (x86)\Common Files\Adobe\dynamiclink\CS6
         [I do have dynamiclinkmanager.exe elsewhere, but Net Nanny only allows you to identify a given file name once]
    5.  Select dynamiclinkmanger.exe, Open, OK
    6.  Repeat steps 3 to 5 but this time for "dynamiclinkmediaserver.exe" which I found in
         C:\Program Files (x86)\Common Files\Adobe\dynamiclinkmediaserver\1.0
    7. Click OK to accept application exceptions
    8.  Exit Net Nanny Admin Tools
    7.  On my computer Photoshop would now load without incident, but if necessary reboot.
    NOTE:  Once I solved the dynamiclinkmanager stopped problem I then encountered an Adobe Media Core stopped problem when I started After Effects and Premier.  To resolve this second problem with Net Nanny I repeated the above steps adding the following application exception:
         "Adobe QT32 Server.exe"
         which I found in
         C:\Program Files (x86)\Common Files\Adobe\dynamiclinkmediaserver\1.0
    [Again there are multiple copies of "Adobe QT32 Server.exe" but Net Nanny accepts only one, and I selected the one in "Program Files (x86)" and not the ones in "Program Files" because of this is where I also found dynamiclinkmanager.exe.  All works fine now.]
    Hope this works for you.

  • Essbase - Smart View

    Hello,
    I have created New Essbase Cubes/Applications in EAS , and I also restarted the APS Services.
    Yet I cant see the new Essbase Applications when I open the Smart View connection.
    Is there anything which should be needed to be done in order to get the new Applications shown in Smart View.
    Thanks !!

    Are you sure that smartview user have access on that application??
    Which version you are on??
    Are you able to see the application under Application group in Shared Services ??
    Cheers!
    Sh!va

  • Essbase Smart View report

    When using the Essbase Excel Add-in, you can highlight part of the Essbase report and refresh only that part. By doing this, you can have multiple Essbase reports on one Excel tab.
    I tried and can't do this in SV (we are using 931). Is there a way to have more than 1 smart view report in one tab?

    SmartView is definitely not the Essbase Add-in.
    I have found that even the "Highlighted Selection Refresh" doesn't behave as I would expect.
    One solution I can see for this situation is to have a sheet that links to 2 tabs. Each tab has 1 SV report.
    There is feature Refresh All Sheets. I find this to be very useful and it works great.
    Hope this helps,
    Brian Chow

  • Essbase smart view not working

    while working with essbase, on connection to Smartview. we are using optimize.xls for practise.
    when we submit data the HsSetValue function does not work. due to which the data is not retrieved and returns a #NAME error. Due to this we are not able to furthur work on the XLS as the input data sheet doesnt work.
    the dimensions are as follows
    Scenario
    Month
    accounts #######
    accounts #######
    accounts #######

    Are you sure you (gasp) want to use the classic add-in?
    There are a lot of limitations:
    http://docs.oracle.com/cd/E17236_01/epm.1112/est_user/apas09s01.html
    This one in particular would be fatal for me:
    >
    In Spreadsheet Add-in, cubes built by Essbase Studio do not display the visual clues that denote drill-through cells. Because there is no way to know for certain which particular cells are drill-through cells, any data cell in the spreadsheet is a potential drill-through cell.
    >
    That link tells you how to test to see if a cell can be drilled on, but why would you want to do that?
    Regards,
    Cameron Lackpour

  • Smart View Connection Error

    Hello Experts,
    1.I have uninstalled the SmartView application version 9.3.1.2 and then installed the latest version 9.3.1.5.
    2.After this I tried to configure the connection to http://issdchypweb:80/HFMOfficeProvider/HFMOfficeProvider.aspx but noticed the XML error as XML Load Error:Invalid XML declaration.
    3.I also installed the MSXML application as well and still encountered the same xml error.
    4.After this the smartview ver. 9.3.1.5 is installed and checked on 3 other PCs and noticed the same error and finally had to rollback to ver. 9.3.1.2 of smartview.
    5.After uninstalling the ver. 9.3.1.5 and reinstalling the ver. 9.3.1.2 of smartview application I was able to configure the connection without any issue.
    Please let me know what is the exact problem.
    Thanks in Advance,
    Regards,
    Anil

    Hello,
    I am trying to test drive smartview version 11, coming form 9.2 after installing it I however get the error message
    "Failed to create XML document. Please check if machine has MSXML setup"
    I am running XP SP2 with MSXML 4.0 with Excel 2003. I do not understand why I get this ? Anybody has any ideas ?
    Thanks for the help
    Edited by: LionelK on 25-Aug-2009 03:05

  • Web View Installation Error

    Dear All i am trying to install the webview on UCCE 8.0 and having the attached error. Please see the logs file i tried to find the issue throug this log file but un successful.

    Not sure what is wrong, but you could start with the first big error that shows up in your log:
    13: ptclhds.ucce.ptcl: Jul 28 2011 03:38:04.475 -0700: %ICM-ERROR-ADSComponentBOImpl.createDistributorServiceAndAccount: The Administration & Data Server (Distributor) service account could not be created for Instance ptcl. Run the Service Account Manager, under Start > All Programs > Cisco Unified CCE Tools, to create (or re-create) the service account.
    david

  • Essbase connection error via smart view

    Hi All
    I'm currently experiencing difficulties connection to essbse via smart view. The application has two databases. All users can connect to one of the databases but not the other one. The essbase server password has not been changed. The version we are currently using is 11.1.1.3
    this is the error from the smart view log file.
    SVC][ERROR:1][SVC4][SVC][ecid: fa3c226a-c687-44cc-afa2-f107f7564a40,0]Cannot get olap user. Essbase Error(1030008): NULL argument (2) passed to ESSAPI function EssGetUserEx
    SVC][ERROR:1][SVC4][SVC][ecid: 6d92db79-2caf-4d8d-a576-86aafa47e21d,0]OLAP_error (1023040): msg from remote site [[Thu Apr 25 09:15:48 2013]Local////Error(1051293) Login fails due to invalid login credentials]
    Any assistence will be verymuch appreciated.

    Hi,
    I got this error while connecting to the Essbase server through EAS Console. To resolve this issue I just removed the Essbase server from the Enterprise view and added the server again. After that I was able to access the Essbase applications.
    But I am not sure about smart view. Also make sure that you are using the correct login credentials to login into the server.
    Thanks,
    Aravindh K

  • Essbase Error (1042017): Network Error in Smart View

    I try to do Ad hoc ahalysis in Smart View via Essbase provider and get Essbase Error (1042017): Network Error: The client or server timed out waiting to receive data using TCP/IP. Check network connections. Increase the olap.server.netConnectRetry and/or olap.server.netDelay values in the essbase.properties.
    I've tried to increase this values in essbase.properties file in C:\Oracle\Middleware\EPMSystem11R1\products\Essbase\aps\bin directory and in Essbase Administration Services console but it has no effect. This behaviour occur only for one application. Early I has no problem with this.
    How this can be fixed?

    Please follow the steps below:
    1) Add the following parameters to the mod_wl_ohs.conf for APS within the aps location match section:
    WLIOTimeoutSecs 1800
    Idempotent OFF
    For Example:
    <LocationMatch ^/aps/>
    SetHandler weblogic-handler
    WeblogicCluster vm0asazon1112:13080
    WLIOTimeoutSecs 1800
    Idempotent OFF
    </LocationMatch>
    Note: mod_wl_ohs.conf file is located in <drive>:\<Oracle_EPM_Home>\Middleware\user_projects\epmsystem1\httpConfig\ohs\config\OHS\ohs_component directory.
    Make a back up copy of the mod_wl_ohs.conf file before editing.
    2) Save the mod_wl_ohs.conf
    3) Restart Reporting and Analysis Framework - Web Application
    4) Restart Oracle Process Manager (ohsInstancexxxxxxxxxx)
    For more details on the Weblogic Plug-ins parameters, please refer to this link: http://download.oracle.com/docs/cd/E13222_01/wls/docs92/pdf/plugins.pdf
    Hope this helps.
    HTH-
    Jasmine.

  • Smart view 11.1.2.3 error in Excel after installation

    I have Microsoft Office 2007 and install smart view of Hyperion Workspace 11.1.2.3 bit but got an non identified issue at open Excel.
    Kindly help.

    Please follow the below steps
    1. From control panel check for any smatview installed , if yes please uninstall the same
    2. take the backup of Windows registry.
    3. delete the entries in HKEY_CURRENT_USER\Software\Microsoft\Office\14.0\Excel\options
    4. download the latest version of smartview from the below link.
    http://www.oracle.com/technetwork/middleware/smart-view-for-office/overview/index.html
    Also just to update before putting any questions in forum please do a search there are lot of same quieries posted earlier.
    Thanks,
    ~KKT~

  • Help On Essbase And Smart View

    Hi all,
    launching a calc script via smart view occours the following error:
    "the request timed out. Contact your administrator to increase netRetryCount an netRetryInterval".
    Here the application log output:
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1013163)
    Received Command [Calculate] from user [user_01] using [Bg12_Cal.csc]
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1200481)
    Formula for member [ELABORATOBDG] will be executed in [TOPDOWN] mode
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1200481)
    Formula for member [ELABORATOBDG] will be executed in [TOPDOWN and CELL] mode
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1200481)
    Formula for member [ELABORATOBDG] will be executed in [TOPDOWN and CELL] mode
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1200481)
    Formula for member [ELABORATOBDG] will be executed in [TOPDOWN and CELL] mode
    [Mon Oct 31 12:19:32 2011]Local/Ap_com/Db_com/user_01/Info(1200481)
    Formula for member [ELABORATOBDG] will be executed in [TOPDOWN] mode
    [Mon Oct 31 13:25:01 2011]Local/Ap_com///Error(1013080)
    Already Connected to Server -- The previous connected request still running, try again
    [Mon Oct 31 13:32:01 2011]Local/Ap_com///Info(1013205)
    Received Command [Get Database Info]
    [Mon Oct 31 13:32:01 2011]Local/Ap_com///Info(1013205)
    Received Command [Get Database State]
    [Mon Oct 31 13:34:07 2011]Local/Ap_com///Info(1013205)
    Received Command [Get Database Info]
    [Mon Oct 31 13:34:07 2011]Local/Ap_com///Info(1013205)
    Received Command [Get Database State]
    [Mon Oct 31 13:38:28 2011]Local/Ap_com///Error(1013080)
    Already Connected to Server -- The previous connected request still running, try again
    [Mon Oct 31 13:39:34 2011]Local/Ap_com///Info(1013210)
    User [user_01] set active on database [Db_com]
    [Mon Oct 31 13:39:34 2011]Local/Ap_com/Db_com/user_01/Info(1013091)
    Received Command [SetAlias] from user [user_01]
    [Mon Oct 31 13:39:34 2011]Local/Ap_com/Db_com/user_01/Info(1013091)
    Received Command [SetSpanRPM] from user [user_01]
    [Mon Oct 31 13:39:34 2011]Local/Ap_com/Db_com/user_01/Error(1013254)
    Hybrid Analysis spanning cannot be enabled on database [Db_com] in application [Ap_com]. Check if the database has Hybrid Analysis and if span into relational source is enabled.
    [Mon Oct 31 13:39:34 2011]Local/Ap_com/Db_com/user_01/Warning(1080014)
    Transaction [ 0xc0005( 0x4eae9706.0x7c060 ) ] aborted due to status [1013254].
    Moreover the configuration file[essbase.properties] is:
    #APS Properties File
    #Tue Apr 21 15:43:14 CEST 2009
    smartview.webservice.autoadd.EssbaseLocalhost.server=false
    system.log.file.buffer.size=0
    nativeSecurity.css.config.file.name=http\://myhubserver\:58080/interop/framework/getCSSConfigFile
    system.dataDir=E\:\\Hyperion\\AnalyticProviderServices/data
    ESSLANG=Italian_Italy.Latin1@Default
    hubServer=myhubserver
    hubLogLevel=warn
    olap.server.netConnectRetry=30
    system.faultTolerance.retryTime=200000
    service.olap.dataQuery.grid.maxColumns=255
    olap.server.netSocketTimeOut=200000
    smartview.webservice.autodeploy.force=false
    hubPort=58080
    system.log.level=warn
    system.session.timeout=60
    system.log.file.name=E\:/Hyperion/AnalyticProviderServices/bin/apsserver.log
    smartview.webservice.client.installer.location=
    applicationRegistrationFile=E\:/Hyperion/AnalyticProviderServices/data/APS.instance
    system.log.console.enable=false
    smartview.system.checkforspecialchars=true
    service.olap.dataQuery.grid.maxRows=5000
    nativeSecurity.casEnabled=true
    productRegistrationFile=E\:/Hyperion/AnalyticProviderServices/data/APS.product
    smartview.webservice.gzip.compression.disable=true
    system.log.trace.enable=false
    system.cluster.monitorInterval=200000
    olap.server.netRetryCount=600000
    nativeSecurity.enabledProviders=css
    domain.store.file.name=E\:\\Hyperion\\AnalyticProviderServices/data/domain.db
    smartview.webservice.sso.httpheader.property.username=
    localID=53426
    smartview.webservice.autodeploy.warn=false
    system.log.file.enable=true
    olap.server.netDelay=200000
    system.log.file.option=0
    Thanks in advance for any help
    Edited by: BlackWolf on 2-nov-2011 7.59
    Edited by: BlackWolf on 2-nov-2011 8.01

    Hi,
    Yes, essbase could help make your reports faster, but it depends also on the cube design. Essbase allows you to calculate all the upper levels and store it. This is (2+2=4), essbase stores 2 and 2 and 4 so then you can go and read the total with the report without having to calculate it wihle the user is retreiving the data. This is a good advantage of essbase.
    About #2, no one can tell you if you should or should not use Informatica as that depends on each company. You can use OBIEE with Essbase and you will need a place to store the data that Essbase will then pull up. It could be any DB you want...
    Hope this helps.

  • Smart View error logging in to an application

    Hello,
    I successfully installed Smart View on a computer with Windows XP SP3. I can connect to the data source, but when I try to connect to an application, after entering the username and password, an error pops up: "Requested operation failed. Error: java.lang.NullPointerException"
    Do anybody know the issue?
    Thanks!

    Hi,
    Are you connecting to a Planning or Essbase datasource connection?
    Can you try connecting to other DS connections to see if it works?
    If connecting to an Essbase datasource, have you configured your APS correctly?
    Seb

Maybe you are looking for