Establishment of the RFC-connection

Hi!
I am about to set up the RFC connection to SAP system from SAP Solution Manager.
The following connection between the systems/server was configured:
my server --> SAP Router 1 --> SAP Router 2 --> SAP System
How should the RFC-connection look like?
The errors I getting are:
Logon                     Connection Error
Error Details     Error when opening an RFC connection
Error Details     ERROR: timeout during allocate
Error Details     LOCATION: SAP-Gateway on host  on host dzla9005 (wp 1)
Is there some special SAP notes for that issue?
Thank you very much!
regards

Hello Thom,
Facing the same issue.
Did you solve it ?
Regards,
Gidion

Similar Messages

  • Error in the RFC Connection

    Hi Expert,
    First, I'm sorry if I post in the wrong thread.
    I have a problem when creating RFC Connection. I want to create RFC Connection between BW systems to R/3 System in SM59.
    I already insert the right IP Address to the target system, but when I test the connection, I got this error :
    host name 'SAP-BO-01' unknown / CPI-C error CM_PRODUCT_SPECIFIC_ERROR
    I already test the connection from BW to R/3 and vice versa, using ping in command prompt, and I got no problem. Also, I already create a log on to the target system, and it was successful, but the RFC Connection still error.
    Did you have any clue or solution about this?
    I really appreciate every helpful comment from you. Thank You...

    Hi
    Do you have mapping in the host file in the server? ask you basis team to check that.
    If you can ping the server, that means connection is fine, only thing is there might be some entry missing in hosts or services file in the server.
    During creation of RFC connection you can directly use the IP address also. as you said you are able to ping the server that means you got to know the IP address. Now use the below command to know the exact hostname.
    ping -a <IP_ADDRESS>
    Regards
    Anindya

  • Kill the RFC connection as soon as the call is completed in Web Dynpro JAVA

    Hi Experts,
    Please guide us how to kill the RFC Connection from web dynpro java as soon as the execution is completed.The FM connection (Adaptive RFC) isnt getting closed in IS-U side. Please guide us how to close them explicitly.
    We are getting the following error
    (102) RFC_ERROR_COMMUNICATION max number of cpic clients exceeded (300)

    hi suvankar ,
    wdContext.current<Modelname>_InputElement().modelObject().modelInstance().disconnectIfAlive();
    use this option after executing your rfc, it will remove the connection to the r/3.
    adn this
    (102) RFC_ERROR_COMMUNICATION max number of cpic clients exceeded (300)  -- is occuring because the pool size defined the jco destination is not sufficient, ask your basis team to increase the pool size.
    Regards
    Govardan

  • How can i change the user that open the rfc connection (sm58) from R/3?

    Hi all,
    i'd like to know how can i customize the user 'connecting' R/3 and BW, i mean: when i launch a data extraction a fixed user creates the rfc connection to BW (and i can see it from tcode sm58 in r/3), i need to use a different username so that it will come be more easy for me to reorganize the rfc queue in case of errors (we are doing some testing), it's possible to do something like this or everyone has to share the same user r/3 side?
    I hope i've been clear...
    thanks for the help
    S.

    Hi...
    Its recommended that only one user executes the RFC because you must manage the authorizations for remote execution only with few users....in case on error you can send the user as a parameter of the RFC  and you can buid the error message with this parameter and identify the user of execution...
    I hope this helps you
    Regards

  • Regarding Type of the RFC Connections

    Hi Experts,
    While We r Creating the RFC Destination in SM 59,
    When We will Create the Connection Type as --3
                                                                       --H
                                                                       --T
    Can Any body Please explain When to go for which connection Type.....
    Regards
    Khanna

    Hi Rajesh,
    Type 3 ABAP Connection :
    ex 1) If we want to execute any function module from one SAP system in another , we need type 3.
    We define an RFC destination say ECC6CLNT100 with required parameters.
    and to test it go to SE37, select any common sap function module and when you execute that it will ask for RFC destination. you provide this destination and the function module will be executed  in the target system.
    ex2) when you create a partner profile, you need to create a port and for creating a port, we need to specify an RFC destination. here also we use type 3.
    Type H.
    ex1) when we need to send xml messages from an SAP system to any other system, we need this.
    For example when we send messages using proxy from SAP system to the integration engine of XI, we need type H.
    Type T.
    ex1) To we make an RFC call from R/3 to XI , we use sender RFC adapter in XI.
    In R/3 system we need to create an RFC destination of type T.
    Rajesh, I hope it answers all your queries.
    & dont forget to award SDN points..:)
    Regards
    Pushkar

  • RFC Connection error message while Debug the running WebDynpro app

    Dear friends,
    I am trying to debug WebDynpro application.
    After configuring the NWDS with the J2EE server instance, I try to run the WebDynpro application, which I want to debug.
    I did selecting the application and run after putting breakpoint at a button click.
    But the webdynpro application uses 2 JCo destiantions, and so it gives JCOClientConnection for logical System: ... Please assure that you have configured the RFC connections and/or logical system name properly for this model! message.
    If I run the same application from the portal, it doesn't give such error message.
    Can anybody help me how can I run the WebDynpro application for debug purpose without getting this error message?
    Thanks and regards,
    Lakshmikanthaiah

    Hi,
    are you running the application on the same server? Or are you using the Debugmode on your local installation.
    If so, you should check the JCO Destinations on you local server.
    <a href="http://localhost:50000/webdynpro/dispatcher/sap.com/tcwdtools/WebDynproConsole">http://localhost:50000/webdynpro/dispatcher/sap.com/tcwdtools/WebDynproConsole</a>
    Regards,
    Dennis

  • Check 10 or more RFC Connections at the same time

    Hi there,
    i have a little question. On a System here there are about 25 RFC connections.
    In all the connections there is a server (where the rfc connection has to connect) s334
    I want to check now if this is correct in all 25 RFC Connections. Is it possible to check this once for all the connection. Or did i have to open every Connection and look whats inside?
    Thanks
    Bjoern

    Hi bjoern bayerschmidt,
       very tuff one we can't tell untill the purpose of RFC..... i can suggest you one thing to rid form this. But you need to take help of ABAP developer. There is a t code called SHDB  which records all the sets you do and generates a ABAP code. Schedule the report in back ground check the below  link:[http://www.erpgenie.com/component/content/article/487] for the sample code.
    or else
    There is a report RFCTST01 using this you can test multiple RFC connections
    you can also schedule this with the diff RFC connections as varients.
    Regards,
    S.Manu.

  • RFC connection error (VPN-access)

    Hi!
    I have the following error for the RFC connection:
    The RFC connection is setup as follows.
    /H/10.101.7.1/S/3299/H/10.151.6.194
    10.101.7.1 = IP of our SAP Router
    10.151.6.194 = IP of customer system
    The RFC connection is established:
    SAP Router (intern) --> Target systems
    The error is:
    Logon     Connection Error
    Error Details     Error when opening an RFC connection
    Error Details     ERROR: partner not reached (host 10.151.6.194, service sapgw20)
    Error Details     LOCATION: SAP-Gateway on host bksapp01 / sapgw20
    Error Details     DETAIL: NiPConnect2
    Error Details     CALL: SiPeekPendConn
    Error Details     COMPONENT: NI (network interface)
    Error Details     COUNTER: 592
    Error Details     ERROR NUMBER: 10060
    Error Details     ERROR TEXT: WSAETIMEDOUT: Connection timed out
    Error Details     MODULE: nixxi.cpp
    Error Details     LINE: 8777
    Error Details     RETURN CODE: -10
    Error Details     SUBRC: 0
    Error Details     RELEASE: 640
    Error Details     TIME: Thu Jun 19 10:42:42 2008
    Error Details     VERSION: 37
    Can some one help to solve the problem?
    Thank you very much
    Thom

    Hi
    Change the saprouter string to
    /H/10.101.7.1/S/3299/H/10.151.6.194/S/32<system number>
    and try !!!

  • RFC connection from SAP Data services to SAP ECC

    We have data services set up in linux machine. I am trying to set up RFC connection between data services and SAP ECC.
    From data management console after creating RFC connection i am getting "RFC_bad_connection" error message. Username , password, system number, hostname and client is working from SAP GUI and has all the authorizations. SAP  gateway and service is name is correct.
    Did anyone had similar issue and what was the solution. Do we have start the RFC connection from linux data services machine, i didn't see any sh executable to do so.
    Thanks in advance for helping to solve the RFC connection issue.
    Edited by: gupta sasha az on Dec 19, 2011 7:24 PM

    I am new to SAP and we have just started work on Data Services.
    I wanted to know the complete procedure as in how can I establish a connection between Data Services and ECC.
    Thanks for your help and time.

  • No trusted/login RFC connection for system BCP in TA SMSY

    Hi,
    i got this error  Early Watch Report  for only production System.
    No trusted/login RFC connection for system BCP in TA SMSY
    Amit

    HI,
    I hope the error message is straight forward.
    Please Check whether you have established RFC connections to the BPC system and the same is avaiable under the RFC connections in TRXn SMSY-Your system -.Test the connections in SM59-BPCs-> READ and Trusted RFCs.
    If its not present, Generate the RFCs again manually.
    Hope this helps.
    Revert for any issues.
    Thanks,
    Jagan
    Edited by: jagadheeshan govindasamy on Oct 9, 2009 3:24 PM

  • Screen Painter and RFC connection issue

    Hello,
    I get the following error when I try to start screen painter:
    EU_SCRP_WN32 : timeout during allocate / CPIC-CALL: 'ThSAPCMRCV'
    I have installed all sapgui components and when I test the rfc connection it
    starts the program but then sends the same error.
    I think it's got something to do with the fact that I'm trying to start this
    program through a saprouter because when I start it locally (within my LAN)
    the program starts without problems.
    I have already applied latest kernel patch.
    Could you suggest what could I do to complete my RFC connection? Should I
    put something under gateway host or gateway service?
    Thanks in advance

    The issue here is that I don't know how to establish de gateway option
    considering I'm using saprouter to connect to sap system.
    Well... If you are asking how to "enable" gateway option then...
    You go to SM59 > Open EU_SCRP_WN32 > Go to "Technical Setting" tab
    Click on change option.
    Put the Gateway host IP address or Host name (SAP Server)  > Save
    Check the connection by "Connection Test" option.
    If any error... pls post here.

  • RFC Connection remains open after portal logoff

    Hi,
    We have configured Universal Worklist in our EP7 EHP1 SPS4 Portal.
    When a user connects to the Portal and launches the UWL it creates an RFC connection to the backend ECC. However, when the user moves away from UWL iview or logs out or closes the browser the RFC connection in the backend still
    remains and is released only after the timeout value reached as set in ECC.
    Are there any settings on the portal or ECC to release the session immediately once  user moves away from UWL or logs out of portal ?
    Thanks,
    Savy.

    Hi my friend
    It costs time and resources to establish an RFC connection, therefore it is not immediately deleted but maintained by the system to be reused. But in case there're special purpose to control RFCs, here're 2 parameters to do so:
    The parameter gw/gw_disconnect is a timeout in seconds to close the TCP connection between two SAP gateways if there is no RFC connetion on it for the given timeout. But if there is an active RFC connection onit it will not be closed even if there is no traffic on that RFC connection. Thats why you need another parameter.
    The parameter gw/keepalive is used to periodically check all active RFC (and other) gateway connections if there was no traffic on them for the given time.
    Regards,

  • RFC Connection (SM59)

    Hi,
    I have developed a RFC. This should be triggered from web. Now we need to establish the RFC connection between R/3 and Web.
    Can any body let me know, what are the required parameters to be given in SM59 fro WEB?
    Regards,
    SK.

    as the above mentioned parmeters are req to establisg rfc connection..
    after defining this , if u want you can test the rfc connection by clieck 'test connection' button in application tool bar..
    normally , this rfc connection wil be done byu basis person only, i think u don't have auth for maintaining rfc connections,,

  • RFC connection Error in SLDCheck

    Hi All,
    I am trying to logon to Integration builder for that i getting the ESR builder address is not maintain. for this i have chk in SLDCheck t code ,there i am getting LCRSAPRFC connection error.I have test the RFC connection in that i am getting the
    the error in register server program
    Error Details     ERROR: program LCRSAPRFC_XID not registered
    now wht i have to do for troubleshooting
    Regards

    Thanx  for reply
    when I test connection to  Connection Test SLD_UC     error
    Logon     Connection Error
    Error Details     Error when opening an RFC connection
    Error Details     ERROR: program SLD_UC not registered
    Error Details     LOCATION: SAP-Gateway on host sapdevpi / sapgw00
    Error Details     DETAIL: TP SLD_UC not registered
    Error Details     COMPONENT: SAP-Gateway
    Error Details     COUNTER: 62
    Error Details     MODULE: gwr3cpic.c
    Error Details     LINE: 1778
    Error Details     RETURN CODE: 679
    Error Details     SUBRC: 0
    Error Details     RELEASE: 701
    Error Details     TIME: Fri Jan  8 11:05:42 2010
    Error Details     VERSION: 2
    RFC SLD_UC is connection T 
    Gateway Host  sapdevpi
    Gateway server  sapgw00
    same error with
    Connection Test SLD_NUC
    Connection Test SAPSLDAPI   ( program Id SAPSLDAPI_DPI )
    Connection Test SAPJ2EE
    In Connection Test LCRSAPRFC error  program id LCRSAPRFC_DPI
    Logon     Cancel
    Error Details     max no of 100 conversations exceeded / CPIC-CALL: 'ThSAPCMRCV' : cmRc=17 thRc=45
    Error Details     ERROR: max no of 100 conversations exceeded
    Error Details     LOCATION: CPIC (TCP/IP) on host sapdevpi
    Error Details     COMPONENT: CPIC (TCP/IP) with Unicode
    Error Details     COUNTER: 82
    Error Details     MODULE: r3cpic_mt.c
    Error Details     LINE: 10791
    Error Details     RETURN CODE: 466
    Error Details     SUBRC: 0
    Error Details     RELEASE: 701
    Error Details     TIME: Fri Jan  8 11:12:56 2010
    Error Details     VERSION: 3
    Regards
    shahid

  • Rfc connection error to saposs

    Hi
    while testing the rfc connection to saposs msg comes timeout occured
    Error:  timeout occured
    Location : Saprouter 37.11 on SAPDEV
    Componenet: NI
    Counter :  1460
    Return code: -93
    Subrc: 0
    Release : 640
    Version : 37
    Plz suggest me.

    > Location : Saprouter 37.11 on SAPDEV
    is the saprouter running on that box and is that box able to connect/ping sapserv?
    Markus

Maybe you are looking for

  • Fetching keystrokes in a JDialog ?

    Hi ! Is there an easy way to fetch any keystrokes (F1 for example) in a JDialog without having to modify the input map for each component of the dialog ? Mikael

  • Why do I have 2 separate charges?

    I have 2 separate charges on my credit card.One for $1 and another for $1.03. I only bought one song so what's with the 2 charges? Sony Vaio   Windows XP  

  • So where can I get, if not design, themes for my 5...

    I'd really like to be able to customize to the fullest. I like the built in Nokia theme, but it's just TOO default for me,a nd besides, EVERYONE has it! Thanks, in advance!

  • How Do I Comile an Ascii File?

    My application needs to generate, compile, and load a class. java.lang.Compiler is not the answer. What is? How do I convert a String or ascii file into a Class object?

  • Standardization of  Menu bar for many device

    Hi everyone, I develop a application which use formular with textfield, list and so on. My application work. But when I test it on Nokia S60, on Siemens and on Sony Ericson : the result is different. Every device add bouton in the menu bar. For examp