hello,
very randomly the ports on the switch stop working and the only way to get them to work again is by resetting the port. we have cisco ip phones connected to the ports and computers connected to the back of the phone.
what i've notices when the phones or computers stop working is that if i unplug the cable from the switch
the LED on the bottom right corner of the port will remain Lid. if i check the config the port shows "suspended"
could you please let me know a better way to resolve this problem, i don't want to reset my switches every day once or twice a day because this is happening so often
thanks

That is normal behavior as those ports share switch fabric resources with the GBICs.  When installed the GBIC will have priority and the associated ports (12 & 24) will not be operational.  You seem to have them configured correctly.
Best Regards,

Similar Messages

  • Help Please! Setting up SNMP on a ESW 540 48 port switch

    Hi There!  This is my first post and I have no idea what I am doing when it comes to SNMP.  We are trying to evaluate our network performance, so we have downloaded a copy of Solarwind’s Orion and installed it on a server.  The topology is as follows.
    A SBS 2003 R2 Server running normal programs.  A second Server 2003 R2( IP 1.2.3.4) running a proprietary program for the business and, hopefully, Orion soon.  The two servers and about 20 XP professional workstations are connected to the esw 540 48 port.  An uplink is attached to a consumer grade Linksys that has 5 workstations attached.  I was told to install SNMP on the workstations behind the Linksys, so I did with the community name = public, Rights = Read Only, and Accept packets from these hosts = localhost and server 1.2.3.4
    I am wondering what configuration I need to do (it is confusing to me) through the cisco web application to set up the switch so that it will communicate with server 1.2.3.4 and the Orion program.  We may switch programs in the future (we are not tied to Orion), but it is what we have to set up the switch with.  I am mainly looking for network throughput information and usage.
    There are just so many options.  Any help would be appreciated….   eric

    Are you trying to use 2 wireless routers in the network?
    Follow this link  for cascading (Connecting) a Linksys Router to Another Router .

  • ESW 540 8-port

    Hello forum
    I bought an ESW 540 8-port switch, mainly for the POE capability over all 8 ports, so that we can power some SPA50X phones.
    The concepts of a "managed" switch are challenging for a newbie.
    Is there a way to make this device behave like a boring "unmanaged" switch ??
    We have plenty of bandwidth, and don't need to be troubled by QoS and virtual LAN's, or all the security stuff at this time.
    Making this device work like an unmanaged switch (aka plug-and-pray) would greatly simplify my life.
    TIA's for any tips or clues.

    Good morning
    Hi brian, thanks for using our forum, my name is Johnnatan and I am part of the Small business Support community. As far I know you can´t turn it as “unmanaged” device, however you can use it without any special configuration, these models are such as "plug-and-play" and by default you can connect computers, then setting ip´s to them and have connectivity, however if someday you are curious about how to use it, we can help you with that, by the way here you can see the guide for your device. I apologize for the inconvenience, however I hope you find this answer useful,
    *Please mark the question as Answered or rate it so other users can benefit from it*
    Greetings,
    Johnnatan Rodriguez Miranda.
    Cisco Network Support Engineer.

  • ESW 540 Combo Ports

    Hello,
    I am interesting what Combo ports mean in ESW 540 which has 4 SFP? Can I use 4 optic SFP at the same time(or 1000BaseT SFP) ??

    Hi Kristijan,
    Just out of interest, are you using firmware version 2.1.19 on the switch, your switch may be using an older version of the firmware ? 
    But there should be no reason why the switch interfaces 11,12,23,24 could not be placed in access mode, seems a bit weird.
    I believe, if you check the VLAN interfaces, vlan1 should still be untagged on those "trunked" ports.
    So, please check the firmware version, but the ESW is covered by a great Warranty, so if you are still having issues, call the Small Business Support Center (SBSC) and allow them to share your screen via webex and resolve your configuration issue one way or the other.
    http://www.cisco.com/en/US/support/tsd_cisco_small_business_support_center_contacts.html
    regards Dave

  • ESW 540 24 port switch

    Hello
    I need to configure a port for a server on the Voice Vlan, however when I do so i get an error and the status is unknonwn and the port isn't working properly
    how do i appropiately configure a port on this switch to be on the voice vlan
    thanks

    Hi Albert,
    Bit concerned about your testing process.  You have proved that untagged switch ports in vlan 1 can communicate with e24.  that makes perfect sense.
    What what are you using (connected on e24 )  to check for tagged packets egressing out of E24 from PCs connected on  vlan 2 and vlan 3.  This testing device you are using must be vlan aware.
    The switch port 24 must be connected to a VLAN aware router or layer 3 switch  that is trunked for ;
    vlan1 untagged
    vlan2 and vlan3 tagged.
    So that routing can occur between vlans.
    regards Dave

  • ESW 540 switch issue

    Hello,
    I have a ESW 540 48 port gigiabit switch.  We have had it a year and a half.  In the past year it has experienced this cycle of problems:
    After a reset, within a week the fans are on full blast. Within less than a month the webgui is gone - not accessable. the switch will still switch, but to do anything to it means it has to be reset completely.
    I cannot figure out how to call Cisco support for this, it has a 5 yr warranty which we are well within. I am ok with the hardware replacement but cannot figure out how to arraign that.  the Support for cisco is not they type of support structure i am used to, in some cases it talks about contracts but then I cannot find prices or even how it works.
    any advice? am i just looking in the wrong places for support or does cisco operate on a diffent model than other tech companies (like Apple or HP) i just am wondering if i should adjust my expectations to less?
    yes i am a bit frustrated, i went out on a limb with going to Cisco for the 'best' and our other switch a 520 is also having problems  
    our old netgear switches worked great for about 5 years until i felt we need to improve them.
    please help a clueless IT guy out

    Hi Eric,  I am sorry to read that you are having difficulties with the ESW 540. Please go to this area we have for the ESW 500 switches: https://supportforums.cisco.com/community/netpro/small-business/sbproductwarranty/proswitchsupport  This area has links to the phone numbers to the small business support center in your area as well as a link to do an online chat with an engineer.  Regards, Cindy Toy Cisco Small Business Community Manager for Cisco Small Business Products www.cisco.com/go/smallbizsupport

  • ESW 540 24 10/100/1000 POE Firmware upgrade

    It seams a new firmware was issued on the cisco download site on january 11 :
    ESW_540_K9_2.1.16.zip
    I have succesfully downloaded this file, but each time I try to unzip it, I get an error.
    I have tried to download it several times, using different navigator and different pcs or macs and using the donwload manager or without it, and I get the same result.
    Also the md5sum of the downloaded file is the one indicated on the download screen :
    Cisco ESW 540 24-Port 10/100/1000 PoE Switch-Release: 2.1.16
    Image name: ESW_540_K9_2.1.16.zip
    Details
    Release
    2.1.16
    Filename
    ESW_540_K9_2.1.16.zip
    Release Date
    11/Jan/2010
    Description
    Firmware for ESW540 Series Pro Switch
    Size
    5032.32 KB (5153092 bytes)
    Router Checksum
    0x1b15
    MD5
    4ba13dac6df27316c7cecb670c42c6e4
    So the conclusion is that this archive is corrupted.
    As this product is for the SMB market, I am unable to open a case on the Cisco site to ask for a working version.
    Who is responsible for this and how to get a good version ?
    Regards,
    Alain RICHARD

    I jumped into the middle of this and have some information to share.
    Firmware release Notes:
    http://www.cisco.com/en/US/docs/switches/lan/csbms/esw500/release_notes/Release_Note_2.1.16.pdf
    states about the first table... (refer to the table):
    In the table above the boot version is different for the 8 port models versus the 24 and 48 port models.
    Software version 2.1.16 requires boot version 1.0.0.7 for the two 8 port models
    esw520-8p-k9-2116.ros for ESW-520-8P
    esw540-8p-k9-2116.ros for ESW-540-8P
    The remaining 24 and 48 port models require boot version 1.0.0.4. if the switch does not have the boot version released in May 2008.
    These are esw520-k9-2116.ros for
    ESW-520-24P
    ESW-520-24
    ESW-520-48P
    ESW-520-48
    and esw540-8p-k9-2116.ros for
    ESW-540-24P
    ESW-540-24
    ESW-540-48
    http://www.cisco.com/cisco/web/solutions/small_business/products/routers_switches/esw_500/index.html-tab-Resources
    - Pages 41-45 of the Admin Guide show how to upgrade the  firmware.
    - Pages 374 - 376 describe the options on the Software  Upgrade page.
    File Type = Software Image for .ros  files
    File Type = Boot Code for .rfb  files
    Basic Outline:
    1.  Upgrade Boot Code (PC --> ESW)
    2.  Upgrade Software Image (PC -->  ESW)
    3.  Change Active Image
    4.  Save Configuration
    5.  Reboot
    The Getting Started section of the Admin Guide should have  text on how to upgrade the Boot Code.
    Software Download should have both the boot code and the Image file listed separetly now:
    A Final note:  CCA does not support boot code upgrade on the ESW switches, only Firmware.

  • VLAN ESW-540

    Hi,
    I have a new switch ESW-540 24-port, I upgrade firmware to 2.1.19.
    I build 2 VLAN for 2 networks: VLAN 2 and VLAN 3 . I don't use the default VLAN 1.
    This is my configuration:
    port e1 and e2 : ACCESS PORT on UNTTAGGED VLAN 2
    port e3 and e4 : ACCESS PORT on UNTTAGGED VLAN 3
    port e1,e2,e3,e4: EXCLUDED VLAN 1
    port e24: TRUNK PORT with UNTAGGED VLAN 1 and TAGGED VLAN 2 and VLAN 3
    Communication (ping) between e1 and e2 --> OK
    Communication (ping) between e3 and e4 --> OK
    Communication (ping) between e1,e2 and e24 --> NOK  :-(
    Communication (ping) between e3,e4 and e24 --> NOK  :-(
    Communication (ping) between e5,e6,e7,.... (VLAN1) and e24 --> OK
    Communication (ping) between e5,e6,e7,.... (VLAN1) and VLAN2, VLAN3 --> NOK - It's correct.
    Any special configuration on e24 trunk port ????
    Can you help me ???
    Thanks,

    Hi Albert,
    Bit concerned about your testing process.  You have proved that untagged switch ports in vlan 1 can communicate with e24.  that makes perfect sense.
    What what are you using (connected on e24 )  to check for tagged packets egressing out of E24 from PCs connected on  vlan 2 and vlan 3.  This testing device you are using must be vlan aware.
    The switch port 24 must be connected to a VLAN aware router or layer 3 switch  that is trunked for ;
    vlan1 untagged
    vlan2 and vlan3 tagged.
    So that routing can occur between vlans.
    regards Dave

  • Esw-540-48 - direclty connected to port 34, still no MAC in ARP table

    Hi all, 
    I have a ESW-540-48 with firmware 2.1.21 (latest)
    I have the strangest problem: I can 't find the MAC address of a computer plugged directly on the switch in the ARP table.
    I'm trying to search by MAC address, and also by port . 
    If I reboot the switch, it does work as expected.
    Do you think it is software related, and in this case is there anything planned to solve this problem ? 
    Or maybe I should just replace my hardware ?
    Thanks

    Hi Firco, it may be possible it is a smart port issue. The ESW switches are very particular to use the correct smart port roles for the connecting devices. I don't think a hardware replacement is warranted unless the given ports absolutely failed to forward.
    As a secondary thought, it could also be a spanning tree issue. Ensure you're using RSTP and/or the host ports have port fast enabled. If using classic spanning tree it takes nearly a minute for a port to go to forwarding state. You can disable spanning tree on the port for testing to quickly rule that out.

  • ESW-540-24 suspended port/s

    HI all,
    I have a customer with a ESW-540-24 running the versions shown below.
    Software Version
    2.1.21
    Boot Version
    1.0.0.04
    The snag I have is that whenever I connect an AP via the power injector, it suspends the port. Using a laptop it's fine connecting straight into the switch.
    Hardware is:
    SB-PWR-INJ1
    WAP321-E-K9
    When I go to port settings > edit in the GUI, it shows the port as suspended and despite checking the box to reactivate the port, it still shows as suspended. I've disconnected the AP and tried the reactivation again but still no joy.
    I've been through the management GUI and looked at all the security related stuff and there is nothing I can see that will cause this - must have missed something though - can anyone shed any light please?
    Many Thanks
    Alastair

    Hi Tom,
    Thanks for the reply.
    Yeah tried that too but when you first log in to the switch and click Smartport Wizard, the new window opens OK but does not allow me to select a port
    I tried hovering over the port on the switch image that appears, selecting it, then selecting the Access Point profile from the dropdown, them it whinges words to the effect of "You must select a port to apply the profile to"
    I thought that might be a bug in the software so upgraded to 2.1.21 but the same thing happens.

  • ESW 520 8-port PoE switch cannot ping

    Hello
    I have an ESW 520 8-Port switch with a management ip address of 192.168.10.2 /24
    After I reboot it, I can successfully ping it from a pc with an ip of 192.168.10.123 for about 50 consecutive times.
    After that, I get a "Destination host unreachable" (this icmp message is sent by my pinging pc (192.168.10.123).
    This obviously seems like a bug.
    Has anybody seen this before.
    Whenever I reboot it, it goes through the same sequence.
    Thanksj

    Hi David,
    I figured out what the problem was.
    The switch was obtaining an ip via dhcp, as it is a DCHP client by default.
    I am used to working with Enterprise level Cisco equipment, so this simple oversight was the cause of the problem.
    The ip that was obtained via dhcp was obviously different than the default ip of 192.168.10.2
    So when the switch was rebooted, it would start off with its default ip of 192.168.10.2.
    As soon as it obtained an ip via dhcp, I could not ping it of course
    Thanks for the  input though

  • New UC560 and 3 ESW-540-24P Switches, best way to wire them

    We are installing a UC560 and 3 ESW-540-24P switches at a client in a couple of weeks.  I have installed many of these but have never installed one with multiple switches.  What is the best way to connect these together physically.  They will be all in the same rack.  Was just wondering the best way to "series" the switches together and what ports to plug them into.  Any suggestions would be appreciated.

    There is a Smart Design: Implementation Guide at :http://www.cisco.com/web/partners/sell/smb/tools_and_resources/smart_business_comm_system.html
    Implementation Guide
    Smart Business  Communications System 2.0 – Implementation Guide
    The implementation guide complements the SBCS 2.0 Design Guide through  the detailed guidance for SBCS 2.0 based Main Office deployment. This  document leverages the GUI configuration capability with easy-to-follow  step-by-step network deployment guidance using CCA v2.2. It also  includes an installation checklist to assist during the installation  process. It is recommended that users refer to the SBCS 2.0 Design Guide  for underlying design guidance and considerations.
    In this (figure 6) it shows a 48 and a 24 port switch connecting to each of the UC560 expansion ports (there are 2 GE ports for expansion on the 560).
    These could also be 2 48 port switches (96 total ports).  (In your scenario, I would connect 2 this way and the third to one of  those 2.)

  • New ESW-540 switch with cold start problems

    Hi
    A customer of mine is having serious problems with several ESW-500 switches.
    He started a discussion under Netpro, but haven't received any answers. This might be the right group?
    He wrote:
    I have two new esw-540 switches (one 48 port  and one 8 port),
    which are making unauthorized cold starts and  that gives me a lot problems.
    (now it is about three switches)
    I added:
    Hi
    My customer needs help with his problem.
    Here is some more information:
    There are three switches with the samHi
    A customer of mine is having serious problems with several ESW-500e problem now, all with the same errormessages from his log
    Ciscosw2  ESW-540-48   SN: DNI1452E71E SW Ver. 1.19 Boot Ver.1.0.0.04
    Ciscosw3  ESW-540-24   SN: DNI1433E507 SW Ver. 1.19 Boot Ver.1.0.0.04
    Ciscosw7  ESW-540-8     SN: CBT15230E9Z SW Ver. 1.1.19 Boot Ver. 1.0.0.07
    From ciscosw7:
    Nov 11 02:16:03 ciscosw7 %OS-F-MEMORY: OSMEMG_rn_free: Memory magic is invalid
    ***** FATAL ERROR *****
    Reporting Task: BNJR.
    Software Version: 2.1.19 (date  14-Jul-2010 time  17:12:34)
    0x184e9c
    0x182484
    0x564110
    0x392684
    0x395998
    0x568630
    0x2df10c
    0x2df654
    0x2e1138
    Nov 11 02:17:14 ciscosw7 %INIT-I-Startup: Cold Startup
    And he sent me a new errormessage today:
    Nov 13 01:38:14 ciscosw5
      %SYSLOG-F-OSFATAL:
      FATAL ERROR: BNJR: ABORT DATA exception
    ***** FATAL ERROR *****
    SW Version  : 2.1.19
    Version Date:  14-Jul-2010
    Version Time:  13:58:28
    Instruction 0x2EFB04
    Exception vector       0x10#
    Program state register
    0x20000013
    0x002ef7ac
    0x002f0390
    0x002f08d8
    0x002f23bc
    0x00134684
    Nov 13 01:39:27 ciscosw5 %INIT-I-Startup: Cold Startup 
    Need urgent advise...
    Thank you!

    Hello!
    My name is Robert and I am network engineer for the Cisco SBSC. This is the correct place for the ESW500 series.
    From the error messages you are seeing, I would recommend to disable the Bonjour service to see if that helps with the reboots. I am currently looking into the error messages you are getting to see if there is a solution. I would recommend giving us a call as well for immediate assistance on the error messages. Below is a link for our support center numbers.
    http://www.cisco.com/en/US/support/tsd_cisco_small_business_support_center_contacts.html

  • ESW 520 8-port - firmware upgrade

    Hi,
    We have a ESW 520 8-port currently on firmware version 2.1.1.19 (boot version 1.0.0.07, VID V01) - Serial number CBT15100AN2
    The latest firmware version is 2.1.1.21, which we downloaded and via Maintenance, Software Upgrade, via HTTP performed an upgrade to this latest version - the upgrade appears to complete, logs show successful however when we restart the switch it still shows as 2.1.1.19 . Very strange!
    Can someone please advise how to get the upgrade to successfully apply?
    Kindest regards,
    Dale. 

    David,
    Thanks for such a question reply - I had tried that and after reboot still shows as 2.1.1.19
    I decided to install the firmware upgarde again, change the active firmware to 2.1.1.21 again, restarted and this time it held.
    Thank you for your assistance, all resolved.
    Cheers,
    Dale.

  • MSI Gaming 5 USB ports issue

    Hello everyone,
    I apologize if I posted this in the wrong section, so as the title says it, sorta of a huge USB ports issue just happened after installing the motherboard / windows / all drivers, even restarted a few times
    then tested the processor and video card.
    Everything ok to that point, I left the pc opened for 3 hours, shut it down, the next day..I couldn't type the windows password.
    Alright restart, that maybe one of those kinks that goes away on it's own I guess..Switched each device in different ports..nothing, tried only one device..still nothing.
    Tried only usb2.0 ports then 3.0 port > a a little panic kicked in :D
    So, in my bios I was seeing 2 keyboards 2 mice..ok...got a bios update from msi site..latest one..flash ..reboot..still nothing.
    Strange part was..they were working just fine in bios and everything prior to windows loading, even after that mouse was showing power ( led was ok )but no functionality.
    Safe mode didn't help..the miracle of last known good config saved the day.
    BUT after choosing the option..ok it started working....randomly..I was typing the windows pass...and right in the middle ...it stopped again..mouse was working...tried again..stopped at 75% of the password.
    Tried again...it worked > Reinstalled every driver.. seems stable for now, though being day 2 of this whole deal.
    So if anyone honors me with enough time to read the story and maybe relate I would glady appreciate it.
    Guys if anyone had any usb related incidents with any of the Z97Gaming boards please share
    If I missed anything, please ask.
    Thank you

    Hello everyone,
    Sorry for the delay in all of this and thank you for the input.
    Specs are below, and this is something currently in the process of being upgraded.
    I7 4790k / MSI Gaming 5 / Sirtec 500W / 8 gb ram  Corsair Vengeance / AMD sapphire 7970 GHZ / one single HDD 1 GB
    The Windows installation went fine on 2 other colleagues from work.
    For the moment stable, I removed and reinstalled all USB related drivers.
    It was a weird one though..

Maybe you are looking for