Ettus research N210 - NI Labview driver

I am using the Ettus research USRP N210 with LFTX/RX daughter boards. I was informed by NI representatives that it is compatible with labview if I download the NI driver software. I need assistance accessing the driver software and the installation procedure.  Thank you.

Hey!
I got an N210 from Ettus and the SBX daughterboard. My intention is to use LabVIEW with that. I used the NI-USRP configuration utility to burn the FPGA and firmware images, but the device will simply not send anything. According to what Erik replied to the initiator of this thread it might be necessary to use property nodes to configure the USRP, but it holds for LFRX/TX or the BasicRX/TX.
Is it possible that it holds for the SBX as well? If not, could you please suggest what might be wrong? As of now I have notbeen configuring the settings by using property node, because I don't know if it is obligatory with SBX board.
Thanks,
Filip

Similar Messages

  • Who do contact about a specific Labview Driver (Stanford Research SR785)

    Hello,
    I'm not sure if this is the right place to go, but how would one find out more about a specific Labview driver if the manufacture doesn't provide support?
    In my case, I have a Labview 8 driver for a Stanford Research SRS785. The driver works great except for one thing, and I'm trying to make sure I'm using it correctly. When I contact Stanford Research, they inform me that they cannot provide support as they did not write the driver.
    How would I find out where the driver came from, where I can get more information, etc.?
    Just for your information, the driver works in every method except for one. If I want to use the "Upload Capture Buffer" (GPIB command is "CGET") it doesn't seem to work and I'm not sure why. No matter how many data points I've captured (In my case, 2 channels at 64,000 points each), when I call the "Upload Capture Buffer" VI, it returns 256,000 values of what appears to be random numbers, but exactly the same for both channels.  Sorry for giving too many details.
    All other driver functions appear to work just fine, as I've used it for other things.
    I'm just wondering, from any LV developers, how you would go about finding the author and asking questions about a driver such as this?
    Regards,
    Jeff

    I'm assuming you are talking about the driver that is available on NI's site? Then the author is someone at NI. At the download page, there is a 'Comments' link. The best forum for discussing drivers is the Instrument Control one. I'm not familiar with the instrument but if you wanted to try a little troubleshooting on your own, you might want to see what the programming manual has to say about the CGET command and what else may need to done prior to getting any valid data. The command being issued by the driver is CGET? channel#,mode and assuming that the channel number and mode are correct, the VI is returning something so it just may be a matter of doing some other inititialization to get valid data. A good way to debug instrument communication is with MAX. There you can experiment with the different commands and queries.
    Just to add a little more, Stanford Research may not provide any support for the driver but they should support the instrument and remote programming. If you say you issue the command CGET? 0,0 and get garbage data, they should be able to tell you why. You don't even need to mention LabVIEW. The commands are the same with whatever programming language you use.
    Message Edited by Dennis Knutson on 07-07-2006 07:48 AM

  • RS232 Labview driver for SR830 lockin Amplifier

    Hi,
    I want to install Labview driver for Stanford Research SR830 lockin amplifier for RS232 port. NI has drivers for GPIB but I could not find any for RS 232 comm port.
    Please let me know how can I find driver for RS232 port.
    Regards,
    Nitin

    Dear Jason S,
    I also want to communicate with sr 830 with the RS232 interface. You said I had to rewrite the whole thing. What does that really mean? Rewrite the driver? If so, what language will it be?
    JasonS' wrote:
    Hello Nitshu-
    As you mentioned, this driver only supports GPIB, and not RS-232.  This driver was originally created in 1994, so it was not created using VISA.  This means that to convert this driver you would need to essentially rewrite the entire thing.  There are not currently any plans to update this driver to support RS-232, but you could easily communicate with it by adding a GPIB Interface to your system.
    Let us know if you have any specific questions we can help answer.
    Jason S.
    Applications Engineer
    National Instruments
    Thank you for answering my question

  • Where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.

    where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.
    if there is no driver maybe you can tell me the closest instrument that comes to this one from the list at,
    http://search.ni.com/query.html?lk=1&col=alldocs&nh=500&rf=3&ql=&pw=595&qp=%2BContentType%3AInstrumentDriver+%2BIDNetManufacturer%3A%22Hewlett-Packard%22&qt=peak+power+analyzer&layout=IDNet
    so i could modify and use the driver

    Hello,
    It looks like Agilent/HP makes the 8990A, but I was not able to find a driver for it that we or Agilent has written for this device.
    Since I am not familiar with the 8990A, I cannot recommend which drivers might be similar, but you are pointed in the right direction. Agilent themselves might know more about which models use similar command sets so that you can modify a driver easily.
    Hope this helps.
    Scott B.
    Applications Engineer
    National Instruments

  • Is there any LabVIEW driver for the Agilent 53147A counter/power meter?

    I am trying to find a LabVIEW driver for the Agilent 53147A counter/power meter, but I cannot find it. Is there any?

    NI does not have a driver and a quick check with Agilent shows that they don't have a driver either.
    You can go to http://www.ni.com/devzone/idnet/ and request a driver. You will also find links on how to create your own driver. Your other option is to use the Instrument I/O Assistant.
    p.s. In the future, you should use the Instrument control board for posting questions. this board is for NI counter/timer products.

  • Labview Driver and manual for HP3437A

    Hi,
    anyone knows if a labview driver for HP3437A exist and where i can get it?
    I also need a manual, but I can not find anything on the HP homepage about
    measurement devices.
    Thanks, Niko

    Hi Niko
    Check this site for downloading over 2000 instrument drivers from different vebdors: http://www.ni.com/devzone/idnet/default.htm
    You'll find the driver for the HP3437A here: http://zone.ni.com/idnet97.nsf/9b2b33e1993d877786256436006ec498/c314c0df1a13834b862568ab005fb92d?OpenDocument
    Regards,
    Luca
    Regards,
    Luca

  • [BUG] Agilent ESA PSA Series LabVIEW driver for Models E4401B and E4402B

    Agilent ESA PSA Series LabVIEW driver are not working with Models E4401B and E4402B.
    Driver Version 2.1.1
    LabVIEW: 2009
    Web Link: http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=309EBE8FF8BC0E76E0440003BA7CCD...
    Problem: ID Query in "Agilent ESA PSA Series.lvlib:Initialize.vi". ID Answer from Instrument is not match with strings in Match Array. Somebody left whitespace at the strings end. ("Hewlett-Packard,\sE4401B\s" and "Hewlett-Packard,\sE4402B\s").
    Everything else is working well.

    Hi JCC,
    Thanks for bringing this to our attention, a Corrective Action Request has been created: CAR - Corrective Action Request - #247239 and a member of R&D will take a look into this to get the issue resolved.
    Kind Regards,
    Applications Engineer

  • Can Labview 7.0 control an instrument without the labview driver?

    hellow,i have an instrument which do not have the labview driver,its output signal is RS232,so can i use labview7.0 to read the signal? thanks!

    You sure can. There is a popular program to check on serial hardware, the loopback.vi. It sends out a signal and reads in a signal. You can modify the vi to send a signal to whatever you need to or receive a signal from whatever you want to. So if you just have an output signal to read in you can modify it to just read in that output signal into a graph or anything you'd like. So you could just get rid of "serial port write.vi" or that entire sequence if you wanted to. I hope that helps.
    Attachments:
    LoopBack.vi ‏42 KB

  • Looking for LabVIEW driver for Agilent (HP) 4349B High Resistance Meter

    I've been looking for a LabVIEW driver for Agilent (HP) 4349B High Resistance Meter.
    Does anyone have one?
    Thanks,
    Avner

    Hello,
    It looks like you'll get a reply by Friday; if not repost and I'll follow up for you
    Thank you,
    JLS
    Best,
    JLS
    Sixclear

  • Labview driver for HP 8560 EC Spectrum Analyzer

    I'd appreciate it very much if somebody help to find
    Labview driver for HP 8560 EC Spectrum Analyzer using GPIB.

    Unfortunately I was unable to find a driver for this instrument either. This leaves you with one of a couple options. First, I would like you to submit a request for this driver at:
    http://zone.ni.com/idnet/other.htm
    We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://zone.ni.com/idnet/development.htm
    We also have a syndicate of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would sugg
    est contacting one of the Alliance members at:
    http://www.ni.com/alliance
    Good Luck.
    Kim L.
    Applications Engineer
    National Instruments

  • URGENT: please help to convert Tektronix TDS754C Labview driver 7.0 to 6.1

    Hello,
    Could someone please try to convert Labview 7.0 driver to a version 6.1?
    I attached Tektronix TDS 754C Labview driver 7.0 below.
    Or National Instruments, please provide me with Tektronix TDS754C Labview 6.1 driver.
    Thanks to everyone in advance,
    Al.
    Attachments:
    tktds7xx.zip ‏1732 KB

    Try this. The error was just because the functions are part of the LabVIEW distribution and had nothing to do with converting the driver.
    Attachments:
    tktds7xx_61.zip ‏1414 KB

  • Download HP34970A labview driver

    Hello,
    When I download Agilent 34970A labview driver and extracted it in my C:\TEMP folder, I couldn't open the labview example; it keeps LOADING and SEARCHING the file.
    There is a message when I open the labview library '[warning: has been deleted, renamed or removed on dis]" it appears every single file.
    Please help.
    Ken

    Yes it needs to be in labview\instr.lib folder.
    Some more info here:
    http://zone.ni.com/reference/en-XX/help/371361J-01/lvmeasconcepts/installing_an_instrument_d/
    Beginner? Try LabVIEW Basics
    Sharing bits of code? Try Snippets or LAVA Code Capture Tool
    Have you tried Quick Drop?, Visit QD Community.

  • AG53131A labview driver

    Hi guys,
    is that anyway to get the labview driver for Agilent 53131 frequecy counter as attahced. I download the driver from NI but unable to control the devices even it is in remote state already. Appreciate if somebody can provide help.
    thanks,
    BS
    Attachments:
    AG53131A.JPG ‏38 KB

    I use the example in the driver i had download. After 2nd time read the measurement, the counter seem like no response and if i configure 2 different function(EX: freq, Period) in different channel also face problem.

  • Labview driver for agilent 8164A tunable laser

    I'm working on a project that involves setting up our Agilent 8164A lightwave measurement system in labview. I cannot locate the driver software on the NI website. Please let me know where I can download the driver for this equipment. Thanks.

    Actually we don't have a driver for that instrument in our website, so that means that we also don't have it in the CD. So you may want to check the Agilent's website, or as a matter of surprise, I found in our database one document that was talking about some past issue and it involved the 8166 instrument, so the author attached the driver for this instrument so we can reproduce what he found out, so I'm attaching this file here which is the file the previous Sr. mention, "hp816x", I installed it in my computer and run it and it is an Agilent made driver, so you can use this one or try to contact the Agilent people. Also you may request a LabVIEW driver been made for this instrument, please see the details at: O
    ther Driver's Resources from our download site.
    Good luck!
    Nestor Sanchez
    Applications Engineer
    National Instruments
    Nestor
    National Instruments
    Attachments:
    816x.exe ‏2875 KB

  • Crossbow with Labview driver

    Hi,
    I'm using Crossbow wireless moduel with NI Labview 8.2. My system is,
    1. Laptop: Crossbow MIB 520 is connected by COM port (virtual COM port, actually it is connected by USB), and Crossbow MICAz is attached to receive signals. The received signals are processed with NI Labview driver from http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=1FB66B354ED149C7E0440003BA230E....
    2. Node #1: Corssbow MDA 320 is used for collecting signal from a pressure sensor, and Crossbow MICAz is attached for sending signals.
    I want to sample the pressure signals about 100Hz. So I made programs which are installed in MICAz for each node. I check the signals with XSniffer program which is provided Crossbow, it just shows the received signals. So I can see the 100Hz signal with it.
    Since the Baud rate for XSniffer is 115200, I changed the Baud rate in the NI Labview dirver which was 57600 to 115200. The Baud rate that I changed is in the zip file, Crossbow XMesh WSN\Private\WSN Connect to Gateway.vi. (Before I change the Baud rate, I could not see the signals in Labview.) However, Labview shows only about 10Hz signal.
    Because another program, XSniffer with same system shows 100Hz signal, but Labview dirver does not. So I guess that there might be limitation about accepting data in Labview driver. So my question is,
    Are there any sampling limitations for accepting data in NI Labview driver for Crossbow? If so, how can I fix it?
    Thanks,
    Joonbum Bae.

    Did you see this thread?  http://forums.ni.com/ni/board/message?board.id=170&message.id=300906