hello all,
i'm facing problem with equipment installation at functional location...
my functional location heirarchy is level 1,2,3
i have tick the istallation allowed check box in level-3 functional location,
as per senario defind in the help document.,   it will not allow to install euipment in levels above i.e, superiour levels level 1,2
Ex:
functional location might have the following structure:
Level 1 Conveyor  installation not allowed
Level 2 Stage A  installation not allowed
             Stage B  installation not allowed
Level 3 Motor 1  installation allowed
             Motor 2  installation allowed
          Conveyor belt 1  installation allowed
and so on.
but in my server it is allowing to install euipment in the superiour F.. locations also ...
i.e, it is allowing to install equipment at laval 1,2
i need to know any config.. required to it..... to get the above functionality or the above senario is wrong...?
thank in advance,
regards.
gunnu

hi thyagarajan,
thank u very much for ur kind replay.
i have created functional locations like below
level 1 : CMR
level 2: CMR-A
             CMR-B
level 3: CMR-A01
            CMR-A02
            CMR-B01
            CMR-B02
  and i marked F location CMR-A01 as Equipment install allowed
now the problem is when i am trying to install equipment at CMR-A01 Functional loaction it allowing asusal..
but  the CMR functional location (level 1)  also allowing to install the equipment
so what is the senario..
it is importent to me....
thanks for your time......
regards,
gunnu
Edited by: gunnus on Apr 27, 2011 7:36 AM

Similar Messages

  • How to create functional location for IE02

    hi all,
    can anyone please tell me that how to create functional location for IE02?
    Regards saurabh.

    To attach a functional location to an equipment, please make sure the following settings,
    1- You have defined the installation allowed at functional location for the following equipment category.
    2- Make sure status of your equipment is AVLB not ESTO.
    then Goto IE02 in the structure tab ---> click change installation location and install the functional location.
    Regards,
    EJ

  • Deletion flag at functional location - equipment installation sallowed

    Hi
    Small question, when we set deletion flag at functional location we can still instal equipment in transaction IE02. Is it possible to configure LF in such way that after setting delation flag or inactivation FL equipment installation shouldn't be allowed??
    We wanted to do it by user status but we can't.
    Thanks for help. Regards. Joanna

    Hi Joanna,
    Try using user exit IEQM0001 and write a custom code, not to allow equipment being installed in deleted / inactive function location.
    Regards,
    Prabhu

  • Problems with hierarchy display of functional locations

    Hello Experts,
    I tried to buid a model whch displays the hierarchy of functional locations and followe all steps of the How-To Model SAP BI System Hierarchies in Visual Composer paper but it does not work as described.
    When I mark the Line I want to drill down and click the drill down button after the refresh it shows only the single value of this line and it does not show the functional locations below. Clicking Drill up nothing moves.
    For Drill down I used the following coding:
    'FILTER_NODE_IOBJNM=@Functional_Location_key;FILTER_VALUE='&#ID[ACCXVU]@Functional_Location_key&';FILTER_COLLAPSE= ;FILTER_IOBJNM=0PM_ORDER__0FUNCT_LOC;CMD_1=CMD%3DDRILL_TO_LEVEL%26LEVEL%3D2%26IOBJNM%3D0PM_ORDER__0FUNCT_LOC%26DATA_PROVIDER%3DDP;'
    For drill up I used the coding:
    'CMD_1=CMD%3DDRILL_TO_LEVEL%26LEVEL%3D'&NSTR(#ID[ACCXVU]@Functional_Location_node_level,'B')&'%26IOBJNM%3D0PM_ORDER__0FUNCT_LOC%26DATA_PROVIDER%3DDP;'
    Any suggestions?
    Thanks a lot in advance
    Kind regards
    Lutz Knabel

    Hello Prachi,
    thanks for your tip, but that does not work either.
    Drilling down either does not show anything (empty result on some lines) and some only show one line of the same Functional location I have selected.
    Drill up only works when the previous drill down resulted in a empty list. If the result has one entry you are locked and you cannot jump back.
    I have collected some screenshots to demonstrate my problem which I would like to provide to you, but I do not have your mail address.
    My Visual composer Version is 700.10.0027.
    I guess SP is 0027, if not please advise how to find out.
    Thanks again. Kind regards
    Lutz Knabel
    E-Mail: [email protected]

  • MAM25 Equipment (de) installation to functional location

    Hi Guru's,
    We are trying to uninstall an equipment from a functional location and then reinstall the same equipment to another functional location, however this does not always work for us.(mam25_030)
    It seems to work, when the uninstall happens before the installation. It fails when installation happens before the uninstall. This is however dependend on the order on which the syncBO's are being handled, or so it seems.
    - Floc with synckey 1 - uninstall equipment
    - Floc with synckey 2 - install equipment
    this works
    But if the order is this:
    - Floc with synckey 2 - uninstall equipment
    - Floc with synckey 1 - install equipment
    Has anyone come across this feature, and/or has a solution for this. Is there a way to influence the order of the syncBO's?
    Thanks,
    Karst
    ps. Running on MAM25 SP15

    This can be achieved but obviously the equipment hierarchy would be disturbed because the equipment can either be installed on a functional location or a superior equipment not both the two. What you can do is the functional location for the superior equipment is to be extended so as to cover the subordinate equipments and obviously there would not be any direct link between the equipment and the superior equipment.
    Equipment: Recorder installed on FLoc: Plant-Recorder
    Equipment: Sensor installed on Floc:Plant-Recorder-Sensor
    that is how you can achieve it but the relationship between the equipment and superior equipment is to be compromised.
    Regards..

  • Installation Of PRTs on Functional Location

    Hi Guys,
    Can anybody tell me if I install the PRTu2019s equipment on functional location what will be the impact on business.
    Because my client want to install all his PRTu2019s on functional location so that he can do the analysis in the different software which is connected with SAP.
    Because that software only can track those equipment which is installed.Please provide me your valuable input.
    AR

    hi
    I dont think there is any impact for installing the PRT towards the funtional location .normally PRT's installation will have little scope .if the client wants the same you can go ahead
    regards
    thyagarajan

  • Euipment or Function location field Mandatory in Work Order

    Hi
    How to make either Equipment or Function location ( either of the one) mandatory in Work Order.
    Thanks ini advance
    Thiyagarajan

    Hi ,
    The field equipment or f.loc can be made mandatory using transaction variants  -- but it would be applicable for all order types .....
    1.use tcode SHD0 , give IW31 in Transaction code and ZIW31 in transaction variants and press create ..
    2.this would take you to IW31 initial screen and enter planning plant and order types and press enter this would give the dialog box of screen variant .Here press continue and this would take you to inside screen .
    3.Here you again press enter and by entering some required data you can finally reach to screen variant of reference object
    and can mark the equipment or f.loc field mandatory as required .
    4.Once this is finished you can you can select local object and save ... and come back and test the same ... now this trans varint ZIW31 can be assigned to user group ...
    go thru the documentation of SHD0 for bette information
    regards
    pushpa

  • Significance of Installation and dismantling of Functional Location /Equipm

    Hi,
    Whta is the significance of Installing and Dismantling of Functional Location and Equipment.
    Thanks in Advance.

    hi
    it is basically for proper structuring of your organization ,if your plant is using the combination of FL and Equipment ,then there may be several FL and equipment in the industry.
    for arranging the equipment in the respective FL this installing and dismantling is provided.
    Also refer [here|http://help.sap.com/saphelp_47x200/helpdata/en/01/d546244ab311d189740000e8322d00/content.htm]
    regards
    thyagarajan

  • Problem when Indicator for Alt. labelling for functional location activated

    Dear Experts,
    In our test system, i had activated alternative labelling for functional lcation for an interface with Locations in ISU.
    After i activated it the entire labelling for functional locations got changed to some arbitrary sustem generated number. For a sample -?0100000000000000142. Is there a ways i can retrieve the original names back. We have reactivated it to inactive again.
    Please help.
    Thanks,
    Boby Mathew

    Hi,
    Once alternative labelling is active, the previous functional location number (IFLOT-TPLNR) and OBJNR become a internal number. The visible location labels are stored in table IFLOS (Field STRNO).
    How easy it is to revert to status 1-Inactive depends on the existance of IFLOS records. If there are no IFLOS records it should be possible to just deactivate via OIPU transaction - Uncheck the 'alt label active' flag - Save.
    Where IFLOS records exist it means functional locations have already been created while the switch was active. These functional locations must be archived. See the full instructions for this process in note [359186|https://service.sap.com/sap/support/notes/359186]. It's a old note but is still valid for all current releases.
    -Paul

  • Genral question on equipment and functional location....

    hi,
    what I have to learn on functional location and equipment other than the below concepts
    creating euipment and installation,
    and customizing like screen sequences of Fun.  locations and equipment....
    and field selection for functional locations and equipment...
    stucture indicator for F locations...
    category of functional locations and equipment...
    becoz i am going to allot for a project more over this is my first proect.......
    Plz help me.........,
    thanks in before
    gunnu

    Hi,
    Under Equipments:
    1. Equipment Master Data
    2. Equipment BoM
    3. Measuring Point
    4. Serial Number Assignment
    5. Installation / Dismantling with Superior Equipment / Functional Location
    6. PRT as Equipment (Production Resource Tools)
    7. Fleet Equipments
    You can find all the helps in Help.sap.com under Plant Maintenance module. Just have a search in google.
    [Equipments & Technical Objects|http://help.sap.com/saphelp_erp60_sp/helpdata/en/b0/df293581dc1f79e10000009b38f889/frameset.htm]
    Regards,
    Maheswaran.
    Edited by: Maheswaran.K on Apr 28, 2011 1:10 PM

  • Duplicate ILOAN for unassigned Functional Location

    Hi,
    We have a peculiar problem: Two ILOANs ( Location & account assignment for technical object) are created by the system for the same equipment - one for the assigned Functional Location and the other for Unassigned Functional Location. When we have assigned a functional location to the euipment, why is the ssytem creating ILOAN for the same equipment with unassigned functional location ? How can this be rectified ? We don't want ILOAN for the unassigned location as it is affecting the reporting.
    Thanks in advance,
    Rgds,
    Sheeja

    Hello,
    The system is creating the same equipment only because during the equipment creation from IBIP the system does not find the superior location to which the equipment is assigned(directly to PG or FL or .....) so this generates a new equipment number(SAP number).You must be searching the equipment through the legacy number so you are finding the two same legacy equipment with different SAP number.
    I would suggest one thing find all the unassigned equipment and create one default FL just like unused FL and assign all the equipment to it.
    Now your reporting will not be affected. DO you have any other issue ???

  • Cannot input a functional location

    Hi Gurus,
    I created a new equipment category. but it does not allow me to input a functional location on structure tab but when im using the standard M it does allow me to install it into a functional location. i check the field selection and they are all "input" what seems to be the problem?
    Thanks!!

    Hi
    In Spro You have to check For your equipment category for" Installation at Functional Location"
    Equipment Usage Period---Define Installation at Functional Location

  • 11i installation problem on NT 4.0 SP6a

    I have one 11i installation problem:
    envoirment: NT 4.0 sp 6a MEM 394MB, cpu 550MHZ HD 40GB
    install MKS, GNUMAKE (3.79), VC++, JDK 1.3 before Apps install.
    And I could see which, gnumake.exe on DOS prompt. But the error
    message say:
    " which command is available; gnumake is not
    available."
    I already set the path varible path=C:\MKSTOO~1\bin;C:\MKSTOO~1
    \bin\x11;C:\MKSTOO~1
    \mksnt;C:\VStudio\Common\Tools\WinNT;C:\VStudio\Common\MSDev98
    \Bin;C:\VStudio\Common\Tools;C:\VStudio\VC98
    \bin;c:\make\WinDebug;c:\make\WinRel
    How to fix this problem?
    Any comments will be appreciated.

    Actually, I already did this and found that this works correctly. I guess it
    was the "install to d:\\weblogic600" that threw me off...
    Thanks,
    Robert
    David Felts wrote:
    Please add "\" after "d:"; this should work. We'll look at making this more
    user-friendly for Beta 2.
    Robert Patrick wrote:
    I tried to install the current beta 1 version of WLS 6.0 today after
    uninstalling the pre-release version that I had previously installed
    with no problems. The problem is that when I try to set the "BEA home"
    to the existing location ("D:" -- so that the product ends up in
    D:\weblogic600), the installer claims that I do not have write
    permission to that directory. This is hogwash since I am logged in with
    administrative priviledges and was easily able to install the
    pre-release copy like this (and yes, I have deleted the previous
    directory).
    Any thoughts?
    Robert

  • Installation problem oracle 11g R2 on oracle enterprise linux 5 update 5

    hello support,
    i've installation problems with oracle 11g R2 on oracle enterprise linux 5 update 5. In the section "ORACLE Net-Konfigurationsassisten" the failure "[INS-20802] Oracle NET-Konfigurationsassistent not success". What's wrong? I've followed the instructions on http://www.oracle.com/technology/pub/articles/smiley-11gr1-install.html
    I've heard the problem can occur with problems in /etc/hosts? My /etc/hosts is configured:
    # Do not remove the following line, or various programs
    # that require network functionality will fail.
    127.0.0.1          oracle localhost.localdomain localhost
    ::1          localhost6.localdomain6 localhost6
    is this ok? what can I do to bring the database-installation to success?
    Thank's for help ;-)
    Edited by: user5782904 on 09.05.2010 14:06

    Here I paste you the configuration of my latest linux box which has a similar environment like yours.
    # hostname
    vmrhel6032.quist.ch
    # domainname
    (none)
    # cat /etc/hosts
    192.168.1.205 vmrhel6032 vmrhel6032.quist.ch
    127.0.0.1     localhost  localhost.localdomain localhost4 localhost4.localdomain4
    ::1           localhost  localhost.localdomain localhost6 localhost6.localdomain6
    # cat /etc/sysconfig/network
    NETWORKING=yes
    HOSTNAME=vmrhel6032.quist.ch
    # cat /etc/sysconfig/network-scripts/ifcfg-eth0
    # Advanced Micro Devices [AMD] 79c970 [PCnet32 LANCE]
    DEVICE=eth0
    HWADDR=00:0C:29:6A:98:70
    ONBOOT=yes
    NETWORK=192.168.1.0
    NETMASK=255.255.255.0
    IPADDR=192.168.1.205
    #Thanks to your post I noted that the hostname consist already of my domain entry. Try your configuration first without domain entry. It should look like:
    # hostname
    vmrhel6032
    # domainname
    (none)
    # cat /etc/hosts
    192.168.1.205 vmrhel6032
    127.0.0.1     localhost  localhost.localdomain localhost4 localhost4.localdomain4
    ::1           localhost  localhost.localdomain localhost6 localhost6.localdomain6
    # cat /etc/sysconfig/network
    NETWORKING=yes
    HOSTNAME=vmrhel6032
    # cat /etc/sysconfig/network-scripts/ifcfg-eth0
    # Advanced Micro Devices [AMD] 79c970 [PCnet32 LANCE]
    DEVICE=eth0
    HWADDR=00:0C:29:6A:98:70
    ONBOOT=yes
    NETWORK=192.168.1.0
    NETMASK=255.255.255.0
    IPADDR=192.168.1.205
    #Otherwise use the first example and don't forget to restart your server resp. the network service. ;)

  • Installation problem with Siebel8.0 on Oracle Enterprise Linux 4 system

    We are having installation problem with Siebel8.0 on Oracle Enterprise Linux 4 system.
    Using interface, when installation come up to “Installing Wizard” window where Gateway Name Server Configuration window should take place, everything just freeze up
    Using console, after installation we obtain following errors:
    Installing Siebel Enterprise Server. Please wait...
    unable to launch: "ksh export
    LD_LIBRARY_PATH=/siebel/gtwysrvr/lib;PATH=${PATH}:.;/root/istemp8058094162222/_bundledJRE_/bin/java
    -Dtemp.dir=/root -cp /siebel/gtwysrvr/bin/setup.jar run -args LANG=ENU
    MODE=LIVE MODEL_FILE=/siebel/gtwysrvr/admin/enterprise_console.scm" error code:
    "236"(SBL-STJ-00152)
    LD_LIBRARY_PATH=/siebel/siebsrvr/lib;PATH=${PATH}:.;/root/istemp8058094162222/_bundledJRE_/bin/java
    -Dtemp.dir=/root -cp /siebel/siebsrvr/bin/setup.jar run -args LANG=ENU
    REPEAT=FALSE MODE=LIVE MODEL_FILE=/siebel/siebsrvr/admin/siebel_server.scm"
    error code: "236"(SBL-STJ-00152)
    LD_LIBRARY_PATH=/siebel/siebsrvr/mgmtagent/lib;PATH=${PATH}:.;/root/istemp8058094162222/_bundledJRE_/bin/java
    -Dtemp.dir=/root -cp /siebel/siebsrvr/mgmtagent/bin/setup.jar run -args
    LANG=ENU MODE=LIVE
    MODEL_FILE=/siebel/siebsrvr/mgmtagent/admin/mgmtagent_ses.scm" error code:
    "236"(SBL-STJ-00152)
    Running command :
    ./ssincfgw -is:javaconsole -console -args LANG=ENU MODE=LIVE MODEL_FILE=/siebel/gtwysrvr/admin/enterprise_console.scm
    Infinite loop of following error pops out:
    An error occurred during wizard bean change notification:
    java.lang.NoClassDefFoundError
    at ConfigInitialize.execute(ConfigInitialize.java:21)
    at com.installshield.wizard.StandardWizardListener.execute(StandardWizardListener.java:123)
    Is there any clue how this error can be solved??
    Thanks in advance!!
    Gordon
    Message was edited by:
    user605023

    I'm facing the same error message while install Siebel 8.0 on OEL. But before I had this ksh problem, it complains about disc space first, and I actually has plenty of disk space under the directory (it needs only 0.7 G and I have 17G free). Anybody has encountered such problem before?
    /net/sdcnas05/vol/engfs01/v_sia/8.0SIA[20405|http://forums.oracle.com/forums/]/Release/Linux/Server/Siebel_Enterprise_Server
    -bash-3.00$ ./setuplinux -is:javaconsole -console
    Initializing InstallShield Wizard........
    Initializing InstallShield Wizard........
    Launching InstallShield Wizard........
    0% 25% 50% 75% 100%
    Welcome to the InstallShield Wizard for Siebel Enterprise Server
    The InstallShield Wizard will install Siebel Enterprise Server on your
    computer.
    To continue, choose Next.
    Siebel Enterprise Server
    Siebel Systems
    Press 1 for Next, 3 to Cancel or 4 to Redisplay [1]
    Siebel Enterprise Server Install Location
    Please specify a directory or press Enter to accept the default directory.
    Directory Name: [siebel] /slot/ems1115/appmgr/20405
    Press 1 for Next, 2 for Previous, 3 to Cancel or 4 to Redisplay [1]
    Please select the products you wish to install.
    [ ] 1 - Gateway Name Server
    [ ] 2 - Siebel Server
    [ ] 3 - Database Configuration Utilities
    [ ] 4 - EAI Connectors
    To select an item enter its number, or 0 when you are finished: [0]: 1
    [X] 1 - Gateway Name Server
    [ ] 2 - Siebel Server
    [ ] 3 - Database Configuration Utilities
    [ ] 4 - EAI Connectors
    To select an item enter its number, or 0 when you are finished: [0]: 2
    [X] 1 - Gateway Name Server
    [X] 2 - Siebel Server
    [ ] 3 - Database Configuration Utilities
    [ ] 4 - EAI Connectors
    To select an item enter its number, or 0 when you are finished: [0]:
    Press 1 for Next, 2 for Previous, 3 to Cancel or 4 to Redisplay [1]
    Configuring uninstallers. Please wait...
    0% 25% 50% 75% 100%
    Choose the setup type that best suits your needs.
    [X] 1 - Typical
    [ ] 2 - Compact
    [ ] 3 - Custom
    To select an item enter its number, or 0 when you are finished: [0]
    Press 1 for Next, 2 for Previous, 3 to Cancel or 4 to Redisplay [1]
    Please select the languages you wish to install.
    [X] 1 - enu - English (American)
    [ ] 2 - fin - Finnish
    [ ] 3 - kor - Korean
    [ ] 4 - cht - Chinese (Traditional)
    [ ] 5 - ita - Italian (Standard)
    [ ] 6 - esn - Spanish (Modern)
    [ ] 7 - deu - German (Standard)
    [ ] 8 - chs - Chinese (Simplified)
    [ ] 9 - tha - Thai
    [ ] 10 - dan - Danish
    [ ] 11 - heb - Hebrew
    [ ] 12 - fra - French (Standard)
    [ ] 13 - nld - Dutch (Standard)
    [ ] 14 - ptb - Portuguese (Brazilian)
    [ ] 15 - csy - Czech
    [ ] 16 - jpn - Japanese
    [ ] 17 - ptg - Portuguese (Standard)
    [ ] 18 - ara - Arabic (Sa`udi)
    [ ] 19 - sve - Swedish
    To select an item enter its number, or 0 when you are finished: [0]
    Press 1 for Next, 2 for Previous, 3 to Cancel or 4 to Redisplay [1]
    {color:#ff0000}*Drive "/slot/ems1115/appmgr/20405" does not have enough space to install the*
    selected configuration. Please free up "766446" KB on drive
    *"/slot/ems1115/appmgr/20405" before continuing.*{color}
    -bash-3.00$ pwd
    /slot/ems1115/appmgr/20405
    -bash-3.00$ df -h .
    Filesystem Size Used Avail Use% Mounted on
    sdc1002nap-vlan1:/vol/ems_39426_1115
    71G 55G 17G 77% /slot/ems1115

Maybe you are looking for