Extending RFPOSXEXT using report RFPOSXEXTEND

Hi,
To add custom fields to FBL5N, I added two custom of fields to the following structures
1. RFPOS - using an append structure with two custom fields
2. RFPOSX - using an append structure with two custom fields
To also extend RFPOSXEXT, I ran the report RFPOSXEXTEND. Both the fields got added to RFPOSXEXT with no issues. I used BTE 00001650 to populate values to these fields and they showed up in FBL5n.
My question is when I move this to Quality and prod systems, should I run the report RFPOSXEXTEND again in those environments too. RFPOSXEXT says that it was last changed by me with no request attached to it. Should I include this change to RFPOSEXT in the same request when I move this to other environments.
Please help.
Thanks.

Hi
U should run the report RFPOSXEXTEND in every enviroment
Max

Similar Messages

  • Extending CR4E using Eclipse RCP plugin's

    <p>Hi Sean,</p><p>I have not started checking this for myself, so this question is more theoretical.</p><p>I plan to customize and extend CR4E using Eclipse RCP plugin architecture. The two main requirements are to add a custom data-source type/provider to the report wizard, and to add a custom result-set wrapper for the said data-source. Other requiremnets may be more look&feel related.</p><p>Assuming licensing issues are met, I had a few questions.</p><p>1. Are there suitable extension points for this in CR4E</p><p>2. Given your current roadmap, is the api stable.</p><p>Thanks,</p><p>Nathaniel</p>

    <p>Unfortunately, developing against these extension points is not currently supported. We definitely plan to support building against these extension points in the future, but in the initial release this was just not in the timeframe. The extension points are likely to change in future releases and we didn&#39;t want to be bound to the initial definition released in version 1. I will keep you updated when this feature does become available. </p><p>Regards,<br />Sean Johnson (CR4E Product Manager) </p>

  • Extends collection using generic type of org.w3c.dom.Element

    Hi, all.
    I am trying to extending collection using PriorityBlockingQueue.
    Extended queue is generic type of org.w3c.dom.Element.
    public class MyQueue<Element> extends PriorityBlockingQueue<Element> {***/}
    Compiler misunderstand to type of Element (as like E ?, not org.w3c.dom.Element), then methods in the code "this.peek ()" will be error reported by type difference.
    At fact, I tried it into MyQueue<Node> extends PriorityBlockingQueue<Node>, it not causes any misunderstanding.
    Is there any hack to indicates that the type is org.w3c.dom.Element ? This mean, MyQueue<org.w3c.dom.Element> extends PriorityBlockingQueue<org.w3c.dom.Element>...
    Thanks.

    public class MyQueue extends PriorityBlockingQueue<org.w3c.dom.Element>

  • Display data in smartforms using report

    hi,
    i want to display data from smartform using report.
    i have a preview buttons in report when i select preview buttons displays in smarts
    regards
    amit

    design the smartform as per ur need and get  the function module generated by smartform and pass it to ur report programas below..
    case sy-ucomm.
    when 'smartform'.
    pass the f.m that is generated by system in smartforms
           CALL FUNCTION '/1BCDWB/SF00000265'
        EXPORTING
        ARCHIVE_INDEX              =
        ARCHIVE_INDEX_TAB          =
        ARCHIVE_PARAMETERS         =
        CONTROL_PARAMETERS         =
        MAIL_APPL_OBJ              =
        MAIL_RECIPIENT             =
        MAIL_SENDER                =
        OUTPUT_OPTIONS             =
        USER_SETTINGS              = 'X'
          DATE_L                     = s_fkdat-low
          DATE_H                     = s_fkdat-high
          PLANT_L                    = s_werks-low
          PLANT_H                    = s_werks-high
      IMPORTING
        DOCUMENT_OUTPUT_INFO       =
        JOB_OUTPUT_INFO            =
        JOB_OUTPUT_OPTIONS         =
        TABLES
          IFINAL                     = ifinal1[]
      EXCEPTIONS
        FORMATTING_ERROR           = 1
        INTERNAL_ERROR             = 2
        SEND_ERROR                 = 3
        USER_CANCELED              = 4
        OTHERS                     = 5
      IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    endcase.

  • Can I use Report Manager to distribute customized oracle reports?

    Hi,
    Can I use Report Manager to distribute customized oracle reports, other than FSG reports?
    If no, is there any function that can be used for distributing reports submitted from concurrent manager in r12.1.2?
    Thanks for any advice!
    HY

    Pl post details of OS and EBS versions.
    >
    Can I use Report Manager to distribute customized oracle reports, other than FSG reports?
    >
    I am not sure - pl ask your friendly Oracle salesperson if this functionality is included in your license.
    >
    If no, is there any function that can be used for distributing reports submitted from concurrent manager in r12.1.2?
    >
    Another option could be to use XML/BI Publisher - again, you will need to check if your license includes distributing custom reports.
    HTH
    Srini

  • I am using report generation toolkit 1.1 with Labview 7.0 and Office 2003 profession​al. The create new report VI opens Excel but throws error (-21471672​62- from automation open VI) when I try to open MS word. please help...

    I am using report generation toolkit 1.1 with Labview 7.0 and Office 2003 professional. The create new report VI opens Excel but throws error (-2147167262- from automation open VI) when I try to open MS word. please help...

    Hi Leo22,
    Does this error occur if you use any of the example programs that come shipped with LabVIEW? I would try opening one of the examples that write data to Word and see if those give you an error. Also, have you tried just putting down a New Report.VI and change the report type to Word? If this simple vi (that's all you need to open Word) breaks, I would check to see if there are any instances of Word still open. Check the task manager to see if any word processes are still open. There should not be a problem accessing Word 2003 from LabVIEW 7.0. If neither of these solutions work, please give some more detail about your application and we can research further. Thanks!
    Jeremy L.
    National Instruments
    Jeremy L.
    National Instruments

  • Labview using Report generation toolkit in 2011 run time engine

    is that possiblity to run the  word in labview using Report generation toolkit in 2011 run time engine

    It is possible to use the Report generaion toolkit with the run time engine.  But you will have to include a lot of VIs from User lib since the report generation toolkit uses a lot of dynamically called VIs and classses.
    Certified LabVIEW Architect
    Certified Professional Instructor

  • Error when using Report Generation Toolkit

    Hi, all,
    I am using Report generation toolkit to generate a report in either
    word or excel format. But i even can't run the "new report.vi". It
    returns an error code of "Bad variable type (-2147352568)", and seems
    this error comes out from the "call by reference" after the
    word/excel's "open VI reference". I have checked the folder
    "C:\Program Files\National Instruments\LabVIEW
    6.1\vi.lib\addons\_office", there are "_exclsub.llb" and
    "_wordsub.llb". The respect VIs are all inside. I don't know why there
    is such error. Currently i am using labview 6.1, Microsoft office 2000
    and Windows NT 4.0.
    Your kindly help will be appreciated very much!!!
    Thannk you in advance!! ^_^
    Your sincerely,
    celery

    So, if you place just New Report.vi on the Block Diagram, wire in the report type and run it, it gives you this error? Do the example programs which ship with the toolset give this same error also? If so, I would just reinstall the toolset first and see if that helps. It sounds like the entire install is corrupt.
    J.R. Allen

  • Error Showing While Using Report Generation ToolKit VIs

    Hi All,
               When I use report generation VIs Like Excel Easy Tables its showing following errors and i am not able to contiune using the same,
    C:\Program Files\National Instruments\LabVIEW 8.2\vi.lib\utility\NIReport.llb\Set Report Font.vi
        - LabVIEW 8.0 changed a constant that was wired to a Case structure to a hidden control to maintain compatibility with LabVIEW 7.1 and earlier.
        - LabVIEW 8.0 changed a constant that was wired to a Case structure to a hidden control to maintain compatibility with LabVIEW 7.1 and earlier.
    what might be the issue, i am using LabVIEW 8.2

    Hi,
    In
    LabVIEW 7.1 and earlier, subVIs could be kept in memory by wiring a
    constant to a Case structure and placing the subVI in a case that would
    not be executed. For example, you could wire a True constant to the
    Case structure and place a subVI in the False case of the Case
    structure, and LabVIEW would load the subVI along with the calling VI.
    However, from LabVIEW 8.0 onwards, the case structure is optimized to remove code that is not going to be executed. Changing the
    constant to a control ensures that this VI behaves as it did in LabVIEW
    7.1 and earlier. If the intent is not to keep the subVIs in memory, you
    can change this control back to a constant by right-clicking the
    control and selecting 'Change to Constant' from the shortcut menu. The
    proper way to keep a subVI in memory without calling it is to use a
    Static VI Reference.
    Good Luck!
    Warm regards,
    Karunya R
    National Instruments
    Applications Engineer

  • Error 1045 Using Report Generation Excel 2010

    Hello,
    The attached code throws an error 1045 when using Excel 2010.  I don't get this error when using Excel 2007.
    Please Advise
    Thanks
    Attachments:
    Source.zip ‏66 KB

    Take a look at this Knowledge Base article and see if if helps.
    Error 1045 When Using Report Generation Toolkit for Microsoft Office
    http://digital.ni.com/public.nsf/allkb/3E4102D8B91D0F9E86256CE0006BADCB
    Applications Engineer
    National Instruments

  • Problem with writing continuous data to excel using using Report Generation vi's

    Hey Everyone,
    I am trying to read the data from DAQ and write to excel continuously using Report Generation vi's. 
    But when I run the VI, it writes only one interation of the while loop (gathering data from DAQ continuously) and doesn't append the data into the same file when I run it again after stoping the VI. 
    I have attached the VI i created. Please let me know if you have any idea to solve this issue. 
    Thanks
    Attachments:
    sample 5.vi ‏35 KB

    There are two problems with your VI.  First, the basic logic of writing/appending to a file (Excel, TDMS, anything) should go something like this:  Open the file, position yourself at the end of the file, then, in the loop, acquire data and write it to the file until you are finished with data acquisition.  When you exit the acquire/write to file loop, then close the file.  In particular, the opening and the closing of the file should not be inside the loop.
    As others have pointed out, writing to Excel might not be optimal, particularly if you are acquiring data at a high rate (and would therefore be writing a lot of data). We actually use Excel in our data acquisition routine, mainly reading from a WorkSheet to get the parameters of a particular stimulus, but also writing the outcome of the response to the stimulus.  As it happens, our "acquisition rate" in this example is on the order of several samples per minute, so there's no problem using Excel (we also sample 16 channels of analog data at 1 KHz -- this gets written as a binary file).
    Second, if you really do want to use Excel, use the (existing) Excel file to which you want to append as the "template" argument of the New Report function.  Then use the Excel Get Last Row function to position yourself at "end of file", as noted above.
    Good Luck.
    Bob Schor

  • How to populate the last empty row in Excel without using Report Generation Kit

    I wrote  a Labview SUb Vi that uses Report Generation Toolkit that is not loaded on the test stand. I am looking to convert it from Report Generation Vi like New Report,  Append Table to Report, Dispose Report. The tunneling through all the report generation Vis seems extensive. Code is attached. Thanks, Greg
    Greg

    Thank you that was a big help...
    I used the Excel Forum to get a lot of great ideas.  My code is almost working.
    There is a 2-D String Array that represents the String data that I am exporting to the Excel File Sheet 1 - 5.
    I am attempting to determine the last populated row in sheet 1 then populate the next row of Sheet 1.  Since all 5 sheets are populated every time, I should not have to search every sheet for the last row.
    I am getting two row populated on sheet 1 with seeming the same data.
     I found an AXExcelWrite2D ArrayWorksheet.vi that I thought would work.  I think there is a Table  determination that is causing me problems.  The link is http://lavag.org/topic/13324-labview-and-excel-activex-or-ado/.  The Application Invoke Node has a convert formula with "FromReferenceStyle" with R1C1 Attached to it.   I am not sure what this function is doing.  When I try to bring the function help up, there is a missing file.
    I am including both the new active x vi and the report generation vi.   Report Generation VI works.
    I would appreciate any assistance I can get on this.
    Thanks
    Greg
    Greg
    Attachments:
    REPU Test Data Population using Active X Write Save.vi ‏92 KB
    REPU Test Data Population.vi ‏60 KB

  • Unmerge cells using report generation

    Hi,
    I have an issue using report generation toolkit, I'm writting text data to a range of cells and the cells get merged because of that. So I need to unmerge cells in order to be able to write again in  thoose cells, because if the cells are merged writing cause an error.
    I have found a VI in the report generation toolkit to merge cells but I can't find one to unmerge them.
    Is there a way to do that?
    Thanks
    Olivier

    Hello Olivier,
    What version of LabVIEW do you have?
    How are the cells getting merged?
    Can you provide information about the error message you are receiving?
    Regards,
    Juan Galindo
    Applications Engineering
    Juan Galindo
    Applications Engineer
    National Instruments

  • Building in carriage returns using Report Query

    I am using Report Querys and Report Layouts. I am trying to build in some carriage returns that will be recognized in my rtf template. I tried using 'chr(10)', br's etc, but it doesn't work. It prints the characters instead of doing the carriage return. Am Imissing something?
    <COMMENTS01>MATHEMATICS (FROST, J): Seldom hands homework in on time Seldom comes to class on time. Retention Possible William works well on patterns chr(10)MEDIA (HATTER, M): Does well on tests Shows a desire to learn chr(10)READING (ANDERSON, L): Does well on tests Does well on quizes These are the notes for Fluency These are the notes for comprehension. chr(10)SCIENCE (BLASK, M): Elementary Code 1 Has trouble with Jupiter. chr(10)</COMMENTS01>

    Bob,
    The string literal 'chr(10)' will not help you much.
    select 'mystring'||'chr(10)'||'mystring' from dual; -- returns 'mystringchr(10)mystring'
    select 'mystring'|| chr(10) ||'mystring' from dual; -- returns 'mystring
    mystring'Cheers,
    Tyson Jouglet

  • 'How to..use reporting variables in BPS'  syntax issue

    Hi,
    I am implementing the white paper 'How to...use reporting variables in BW-BPS' and I am getting a syntax error in the include YBW_BPS_VAR_READ. The error indicates 'Statement is not accessible' for my line:
    SELECT SINGLE * FROM ybw_bps_var_map
    ybw_bps_var_map being my transparent table as described in the white paper.
    I have never seen such a syntax error, has anyone had the same issue? My code is the one in the white paper.
    Thanks for any help.
    David

    Hi David,
    I have the coding up and running. I have not seen this error before and don't know how to resolve it. If you cut&paste it from the PDF, then maybe some special characters got pasted into the ABAP editor. Try to delete the line and type it in manually.
    Regards
    Marc
    SAP NetWeaver RIG

Maybe you are looking for

  • Can't Alt+double click to open an image?

    hello:                                                                                                             Level: Newbie  Id:Cs6  Os:Win8 i have read that Win8 is compatible with Id, Ps and Illy (i'm not sure about the other CC apps but i hop

  • Videos no longer recognised as videos in my ipod

    Hello, I've downloaded various videos and vodcasts from the itunes store. Never had any problem viewing them before. About a week ago, I plugged my ipod into a different laptop for charging and now the ipod no longer brings up lists of movies etc und

  • How do I get pages documents to share between a PC and an IPad?

    I have read the instructions for both the IPad and the PC cloud installation and the document sharing portion. I did everything that the apple website said to do but my documents aren't sharing. Everything is up to date: itunes, pages.  How do i get

  • Program takes long time to create batch

    Hi, I am uploading batch using a custom program which uses BAPI_BATCH_SAVE_REPLICA.The program takes 4 hrs for uploading 100000 records. But when I am using a file with 400000 records. It creates the second batch after 8 hrs from the starting of the

  • How to change the order of the top level navigation?

    hello, i don't find where i can change the order of the top level navigation. help would be great because there is no documentation for this issue. greets daniel